10 AMP POWER RELAY HP RELAYS
FEATURES
1. High-capacity and long life
Mechanical life is more than 10 million
operations and, with electrical life of more
than 200,000 operations (resistive load
10 A; inductive load 7.5 A), the relay has
excellent inductive load durability.
2. Easy mounting and wiring
The terminal arrangement is apparent at
a glance and wiring is easy. Moreover,
quick tab terminal is also possible.
3. Operation indicator option
Optional operation indicators are
available for easy visual confirmation that
relays are operating. They simplify
maintenance.
4. UL/CSA approved
5. Wide range of sockets and terminal
sockets
To enable use with DIN rails, DIN
terminal sockets are also available.
Compliance with RoHS Directive
TYPICAL APPLICATIONS
HP relays enjoy wide use in various
applications, particularly in automation
controls and remote controls.
Applications include:
1. Industrial machinery
For controlling positioning, pressure, and
temperature in molding equipment,
boilers, pumps, charging pressure
equipment, measuring and evaluation
equipment, textile machines, etc.
2. Machine tools
Control of positioning and directional
change in turning machines, lathes,
borers, etc.
3. Food processing packing machines
Automatic control of packing equipment
for milk and seafood, bottling, canning,
and packaging
4. Office equipment
Control of copiers, time recorders, etc.
5. Coin operate machines
Control of food, cigarette, and other
vending machines
6. Measuring devices and equipment
For repeating installation of control
signals and in power amplifiers
7. Generators, transformers and
power receiving equipment.
Functional parts in protective equipment,
functional assistance in automatic
adjustment equipment, telemeters and
other remote monitoring equipment
8. Control of conveyance equipment
Control panels for elevators, escalators,
and other conveyance equipment, control
of all kinds industrial transport equipment
such as conveyors.
9. Amusement equipment
Control of equipment in amusement
parks, etc., control of bowling alley
equipment, control of fountains in public
parks
About Cd-free contacts
We have introduced Cadmium free type
products to reduce Environmental
Hazardous Substances. (The suffix “F”
should be added to the part number. The
Suffix “F” is required only for 4 Form C
contact type. The 2 Form C and 3 Form C
contact type is originally cadmium-free,
the suffix “F” is not required.)
Please replace parts containing
Cadmium with Cadmium-free products
and evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Including discontinued products ( )
HP
ORDERING INFORMATION
TYPES
1. Plug-in type
Standard packing (2 Form C): Carton: 20 pcs.; Case: 100 pcs.
Standard packing (3 Form C, 4 Form C): Carton: 10 pcs.; Case: 50 pcs.
Coil voltage 2 Form C 3 Form C 4 Form C
Part No. Part No. Part No.
6V AC HP2-AC6V HP3-AC6V HP4-AC6V-F
12V AC HP2-AC12V HP3-AC12V HP4-AC12V-F
24V AC HP2-AC24V HP3-AC24V HP4-AC24V-F
48V AC HP2-AC48V HP3-AC48V HP4-AC48V-F
100V AC HP2-AC100V HP3-AC100V HP4-AC100V-F
115V AC HP2-AC115V HP3-AC115V HP4-AC115V-F
200V AC HP2-AC200V HP3-AC200V HP4-AC200V-F
220V AC HP2-AC220V HP3-AC220V HP4-AC220V-F
240V AC HP2-AC240V HP3-AC240V HP4-AC240V-F
6V DC HP2-DC6V HP3-DC6V HP4-DC6V-F
12V DC HP2-DC12V HP3-DC12V HP4-DC12V-F
24V DC HP2-DC24V HP3-DC24V HP4-DC24V-F
48V DC HP2-DC48V HP3-DC48V HP4-DC48V-F
100V DC HP2-DC100V HP3-DC100V HP4-DC100V-F
110V DC HP2-DC110V HP3-DC110V HP4-DC110V-F
Contact arrangement
2: 2 Form C
3: 3 Form C
4: 4 Form C
HP
Operation indication
Nil:
L:
Without indication
With indication
Contact material
F:
Nil:
4 Form C, Silver alloy (cadmium-free)
2 Form C, 3 Form C (Silver)
With LED indicator type
Coil voltage: 6, 12, 24 V AC 6, 12, 24, 48 V DC
With neon lamp type
Coil voltage: 100, 115, 200, 220, 240 V AC 100, 110 V DC
Terminal arrangement
Nil:
TM:
M:
Standard plug-in terminal
TM type (2 Form C only)
Direct mounting (3 Form C only)
Coil voltage
AC
DC
6, 12, 24, 48, 100, (115), 200, (220), (240) V
6, 12, 24, 48, 100, (110) V
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Including discontinued products ( )
HP
2. Plug-in type (with LED indication)
Standard packing (2 Form C): Carton: 20 pcs.; Case: 100 pcs.
Standard packing (3 Form C, 4 Form C): Carton: 10 pcs.; Case: 50 pcs.
3. TM type and Direct mount type
Standard packing: Carton: 10 pcs.; Case: 50 pcs.
4. Direct mount type (with LED indication)
Standard packing: Carton: 10 pcs.; Case: 50 pcs.
Notes: 1. Standard packaging is handled in units of inner cartons. Please specify if you require inner cartons to be boxed.
2. Sockets, terminal sockets and installation brackets are not included. Please order these separately.
3. For products compliant with international standards, please refer to the standards chart.
Coil voltage 2 Form C 3 Form C 4 Form C
Part No. Part No. Part No.
With LED indication
6V AC HP2-L-AC6V HP3-L-AC6V HP4-L-AC6V-F
12V AC HP2-L-AC12V HP3-L-AC12V HP4-L-AC12V-F
24V AC HP2-L-AC24V HP3-L-AC24V HP4-L-AC24V-F
With neon lamp
100V AC HP2-L-AC100V HP3-L-AC100V HP4-L-AC100V-F
115V AC HP2-L-AC115V HP3-L-AC115V HP4-L-AC115V-F
200V AC HP2-L-AC200V HP3-L-AC200V HP4-L-AC200V-F
220V AC HP2-L-AC220V HP3-L-AC220V HP4-L-AC220V-F
240V AC HP2-L-AC240V HP3-L-AC240V HP4-L-AC240V-F
With LED indication
6V DC HP2-L-DC6V HP3-L-DC6V HP4-L-DC6V-F
12V DC HP2-L-DC12V HP3-L-DC12V HP4-L-DC12V-F
24V DC HP2-L-DC24V HP3-L-DC24V HP4-L-DC24V-F
48V DC HP2-L-DC48V HP3-L-DC48V HP4-L-DC48V-F
With neon lamp 100V DC HP2-L-DC100V HP3-L-DC100V HP4-L-DC100V-F
110V DC HP2-L-DC110V HP3-L-DC110V HP4-L-DC110V-F
Coil voltage 2 Form C (TM type) 3 Form C (direct mount type)
Part No. Part No.
6V AC HP2-TM-AC6V HP3-M-AC6V
12V AC HP2-TM-AC12V HP3-M-AC12V
24V AC HP2-TM-AC24V HP3-M-AC24V
48V AC HP2-TM-AC48V HP3-M-AC48V
100V AC HP2-TM-AC100V HP3-M-AC100V
115V AC HP2-TM-AC115V HP3-M-AC115V
200V AC HP2-TM-AC200V HP3-M-AC200V
220V AC HP2-TM-AC220V HP3-M-AC220V
240V AC HP2-TM-AC240V HP3-M-AC240V
6V DC HP2-TM-DC6V HP3-M-DC6V
12V DC HP2-TM-DC12V HP3-M-DC12V
24V DC HP2-TM-DC24V HP3-M-DC24V
48V DC HP2-TM-DC48V HP3-M-DC48V
100V DC HP2-TM-DC100V HP3-M-DC100V
110V DC HP2-TM-DC110V HP3-M-DC110V
Coil voltage 3 Form C
Part No.
With neon lamp
100V AC HP3-ML-AC100V
115V AC HP3-ML-AC115V
200V AC HP3-ML-AC200V
220V AC HP3-ML-AC220V
240V AC HP3-ML-AC240V
100V DC HP3-ML-DC100V
110V DC HP3-ML-DC110V
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Including discontinued products ( )
HP
RATING
1. Coil data
1) AC coils
2) DC coils (20°C 68°F)
Notes: 1. The rated current area is ±15% (60Hz) [AC coils],. ±10% (20°C) [DC coils]
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate ±0.4% for every ±1°C change in temperature.
3. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage. In particular, for AC operation, if the impressed voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will
flow leading possibly to coil burnout.
4. For use with 200 V DC, connect a 6.7k (10W) resistor, in series, to the 100 V DC relay [3 Form C type is .6.4k (5W); 4 Form C type is .6.2k (10W)].
5. As a general rule, only a pure DC voltage should be used for the coil drive.
However, a DC power supply that contains ripples has characteristics that differ from pure DC.
Therefore, please verify characteristics (operate voltage, release voltage, humming) using the actual circuit that will be used.
Contact
arrangement
Nominal coil
voltage
Nominal coil current
(mA)
Nominal operating
power (VA)
Inductance
(H) Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Max. allowable
voltage
(at 20°C 68°F)
50Hz 60Hz 50Hz 60Hz 50Hz 60Hz
2 Form C
6V AC 349mA 310mA 2.09VA 1.9VA 0.051 0.049
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
12V AC 181.2mA 160mA 2.17VA 1.9VA 0.198 0.190
24V AC 94mA 78mA 2.25VA 1.9VA 0.753 0.776
48V AC 46.5mA 39mA 2.23VA 1.9VA 3.055 3.106
100V AC 25.3mA 21mA 2.36VA 2.1VA 12.60 12.03
115V AC 23.1mA 18mA 2.31VA 2.1VA 16.70 15.83
200V AC 12.4mA 11mA 2.48VA 2.2VA 48.03 45.81
220V AC 10.6mA 9.5mA 2.34VA 2.1VA 61.28 57.90
240V AC 10.0mA 9.0mA 2.40VA 2.2VA 69.00 66.26
3 Form C
6V AC 594mA 520mA 3.56VA 3.1VA 0.03 0.030
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
12V AC 297mA 260mA 3.56VA 3.1VA 0.123 0.119
24V AC 148.7mA 130mA 3.56VA 3.1VA 0.0494 0.475
48V AC 74.2mA 65mA 3.56VA 3.1VA 1.976 1.899
100V AC 36.4mA 32mA 3.64VA 3.2VA 8.500 8.038
115V AC 32.5mA 28.5mA 3.74VA 3.3VA 10.79 10.36
200V AC 18.2mA 16mA 3.65VA 3.2VA 33.53 32.10
220V AC 16.0mA 14.2mA 3.54VA 3.1VA 41.35 39.32
240V AC 15.8mA 13.9mA 3.79VA 3.3VA 45.94 44.05
4 Form C
6V AC 909mA 800mA 5.46VA 4.8VA 0.020 0.019
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
12V AC 456mA 400mA 5.47VA 4.8VA 0.080 0.077
24V AC 229mA 200mA 5.49VA 4.8VA 0.320 0.309
48V AC 108mA 95mA 5.18VA 4.6VA 1.348 1.292
100V AC 57.3mA 50mA 5.73VA 5.0VA 5.348 5.156
115V AC 47.6mA 42mA 5.47VA 4.8VA 7.264 6.953
200V AC 28.5mA 25mA 5.69VA 5.0VA 21.27 20.45
220V AC 23.8mA 21mA 5.24VA 4.6VA 27.75 26.57
240V AC 23.3mA 20.5mA 5.58VA 4.9VA 30.98 29.75
Contact
arrangement
Nominal coil
voltage
Nominal coil current
(mA)
Nominal operating
power (W)
Coil resistance
()
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Max. allowable
voltage
(at 20°C 68°F)
2 Form C
6V DC 240mA 1.5W 25
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
12V DC 109mA 1.3W 110
24V DC 54.5mA 1.3W 440
48V DC 26.7mA 1.3W 1,800
100V DC 14.9mA 1.5W 6,700
110V DC 15.0mA 1.7W 7,300
3 Form C
6V DC 250mA 1.5W 24
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
12V DC 120mA 1.4W 100
24V DC 60mA 1.4W 400
48V DC 31mA 1.5W 1,560
100V DC 15.6mA 1.6W 6,400
110V DC 14.9mA 1.6W 7,450
4 Form C
6V DC 273mA 1.6W 22
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
12V DC 127mA 1.5W 95
24V DC 63mA 1.5W 380
48V DC 32.0mA 1.5W 1,500
100V DC 16.3mA 1.6W 5,950
110V DC 15.7mA 1.7W 7,000
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Including discontinued products ( )
HP
2. Specifications
Notes: *1 This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 For the AC coil types, the operate/release time will differ depending on the phase.
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to 6. Conditions for operation,
transport and storage mentioned in AMBIENT ENVIRONMENT.
3. Electrical life
1) AC load
Note: When the electromagnet or exciting coil (Solenoid, etc.) is the load, the value of motor or lamp load is applicable.
2) DC load
Note: For DC inductive loads, use an arc suppressing circuit.
Note: Cautions at DC load use
When used under a DC load operating at high repetition rate with considerable arcing, corrosion of the contacts and/or the contact blades is likely to occur.
Characteristics Item Specifications
Contact
Arrangement 2 Form C, 3 Form C, 4 Form C
Initial contact resistance, max Max. 15 m (By voltage drop 6 V DC 1A)
Contact material 2 Form C, 3 Form C Ag
4 Form C Ag alloy (cd free)
Rating Nominal switching capacity 10A 250V AC (resistive load)
Min. switching capacity (Reference value)*1100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 100M (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min (2 Form C, 4 Form C).
2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.)
Between contact sets 1,500 Vrms for 1min (2 Form C, 4 Form C).
2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.)
Between contact and coil 1,500 Vrms for 1min (2 Form C, 4 Form C).
2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.)
Temperature rise Max. 65°C (By temperature method, at 40°C, nominal current)
Operate time*2Max. 25ms (2 Form C), Max.30ms (3 Form C, 4 Form C)
(Nominal voltage applied to the coil, excluding contact bounce time.)
Release time*2Max. 25ms (2 Form C), Max.30ms (3 Form C, 4 Form C)
(Nominal voltage applied to the coil, excluding contact bounce time.) (without diode)
Mechanical
characteristics
Shock resistance Functional Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Destructive Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 2 mm
Expected life Mechanical Min. 107
Conditions Conditions for operation, transport and storage*3Ambient temperature: –50°C to +40°C –58°F to +104°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. Operating speed 20 cpm (at max. rating)
Unit weight 2 Form C: approx. 60g 2.12oz, 3 Form C: approx. 100g 3.53oz, 4 Form C: approx. 125g 4.41oz
Voltage 125V AC 250V AC Expected life
Load Resistive (A) (cosϕ=1) Inductive (A) (cosϕ=0.4) Resistive (A) (cosϕ=1) Inductive (A) (cosϕ=0.4)
Current
——10 7.5 Min. 2×105
10 7.5 7.5 5 Min. 5×105
5332Min. 106
10.7 0.6 0.4 Min. 2×106
Voltage 24V DC 125V DC Expected life
Load Resistive (A) Inductive (A) Resistive (A) Inductive (A)
Current
—7—Min. 2×105
7.5 5 0.5 0.4 Min. 5×105
530.3 0.2 Min. 106
10.6 0.1 0.06 Min. 2×106
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Including discontinued products ( )
HP
4. Life of LED and neon lamp (with operation indication)
REFERENCE DATA
DIMENSIONS (Unit: mm inch)
Continuous Use rating (ON time) 50%
With neon lamp 25,000 hours (approx. 3 years) Approx. 6 years
With LED indication 50,000 hours (approx. 5.5 years) 100,000 hours (approx. 11 years)
(Coil terminal No.)
Schematic
LED
Protection diode
Schematic
With LED indication LED
With neon lamp
Neon lamp
(Coil terminal No.)
Coil terminal No. and polarity (DC type)
Polarity HP2 HP3 HP4
Te r minal
No.
(+) 7 10 10
(–) 2 2 1
1. Life curve 2. Max. switching capacity
10
0
100
200
300
400
500
600
700
800
900
1,000
Load current, A
Operations, ×104
125 V AC cosϕ = 1
5
2
5
0
V
A
C
c
o
s
ϕ
=
1
Mechanical life
more than 10,000,000
operations
100 500 1,00010
10
1
0.1
DC inductive
load
(L/R=7ms)
AC inductive load
(cosϕ=0.4)
DC resistive
load
AC resistive load
Contact voltage, V
Contact current, A
7
.276
51
2.008
.197.315 .197
58 5
44
1.732
0.5
.020
25
15
.984
.591
.031
8
7
63
54
15.26
5.26 5.26
.207 .207
10
.394
9.5
.374
7.5
.295
36
1.417
5.8
.228
5.3
.209
5.26
.207
.207
2
.031
0.8 0.8
0.8
0.8
.031
.031
Compatible with tab terminal
#205 series receptacle.
Plug-in type (2 Form C) External dimensions Schematic (Bottom view)
8
7
6
5
1
2
3
4
Dimension:
Max. 2mm .079 inch:
2 to 9mm .079 to .354 inch:
9 to 20mm .354 to .787 inch:
Min. 20mm .787 inch:
Tolerance
±0.2 ±.008
±0.5 ±.020
±1 ±.039
±1.5 ±.059
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Including discontinued products ( )
HP
0.5
.020
44
1.732
3
.118
7
.276
.197
5
38
1.496
36
1.417
36
1.417
38
1.496
11 11
.433 .433
8.5
.335
.217
5.5
.226
5.75
.187 .187
.098
.098 2.5
2.5
7.65
.301
4.1
.161
0.5 .020
0.5
.020
.020
0.5
0.5 .020
2.079
2.079
.187 4.75 4.754.75
.197 .315 .197
585
Compatible with tab terminal
#187 series receptacle.
Plug-in type (3 Form C) External dimensions Schematic (Bottom view)
10
11
9
8
3
6
7
1
2
4
5
Dimension:
Max. 2mm .079 inch:
2 to 9mm .079 to .354 inch:
9 to 20mm .354 to .787 inch:
Min. 20mm .787 inch:
Tolerance
±0.2 ±.008
±0.5 ±.020
±1 ±.039
±1.5 ±.059
0.5
.020
44
7
.276
51
1.732
2.008
36
1.417
10
10 .394
.394
25
.984
5.26
7 9 5 4
312148
5.26 5.26 5.26
.207 .207 .207 .207
50
1.969
40
1.575
10
.394
.031 .031 .031.031 0.8 0.8 0.80.8
9
15 11
25.26
9.5
.374
7.5
.295
5.8
.228
5.3
.209
5.26
.207
.207
0.8
0.8
.031
.031
1
10
Compatible with tab terminal
#205 series receptacle.
Plug-in type (4 Form C) External dimensions Schematic (Bottom view)
915
10
8
7
12
5
11 2
1
14
6
3
4
Dimension:
Max. 2mm .079 inch:
2 to 9mm .079 to .354 inch:
9 to 20mm .354 to .787 inch:
Min. 20mm .787 inch:
Tolerance
±0.2 ±.008
±0.5 ±.020
±1 ±.039
±1.5 ±.059
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Including discontinued products ( )
HP
.110
2.8
46.8
1.843
24.7
.972
7
.276 5.5
.217
35.7
1.406
15
.591
.031 .031
0.8 0.8
58
2.283
45.5
1.791
9.5
.374
7.5
.295
5.3
.209
0.8
2.25R .089R
5.26
.207 5.26
.207
4.5
.177
10
.394
5.26
5.26
.207
.207
0.8
.031
.031
5.8
.228
Compatible with tab terminal
#205 series receptacle.
TM type
(2 Form C)
External dimensions
Schematic (Bottom view)
8
7
6
5
1
2
3
4
Mounting hole diagram
Tolerance: ±0.1 ±.004
(Pitch for side-by-side mounting)
Relay space
(Area shown by the
broken line)
2-M.157 screw hole
or 2-.177 dia. hole
2-M4 screw hole
or 2-4.5 dia. hole
45.5
1.791
2
.079
30
1.181
Installed relay
Nut Panel (chassis)
Spring washer
2-M.157
2-M4 screw
35.7
1.406
52.3
2.059
Dimension:
Max. 2mm .079 inch:
2 to 9mm .079 to .354 inch:
9 to 20mm .354 to .787 inch:
Min. 20mm .787 inch:
Tolerance
±0.2 ±.008
±0.5 ±.020
±1 ±.039
±1.5 ±.059
.276
7
.118
3
5
.197
20.5
.807
.433
11
38
1.496
16
.630
4.2
.165
73.5
2.894
60
2.362
44
1.732
2.1R
.083R
16
.630
.165
4.2
.083R
2.1R
36
1.417
36
1.417
38
1.496
11 11
.433 .433
8.5
.335
.217
5.5
.226
5.75
.187 .187 .187
4.75 4.75 4.75
2.5
.098
2.5
.098
7.65
.301
4.1
.161
0.5
.020
0.5
.020
0.5 .020
0.5 .020
2.079
2
.079
Compatible with tab terminal
#187 series receptacle.
Direct mounting type
(3 Form C)
External dimensions
Schematic (Bottom view)
10
11
9
8
3
6
7
1
2
4
5
Mounting hole diagram
Tolerance: ±0.1 ±.004
(Pitch for side-by-side mounting)
40
1.575
60
2.362
2
.079
2-M.157 screw hole
(or 2-.165 dia. hole)
2-M4 screw hole
(or 2-4.2 dia. hole)
Relay space
(Area shown by the
broken line)
Installed relay
38
1.496
16
.630
.197
5
7
.276
.807
20.5
.433
11
73.5
2.894
2.362
60
44
1.732
2-M.157
2-M4 screw
Spring washer
Panel
(chassis)
Nut
36
1.417
Dimension:
Max. 2mm .079 inch:
2 to 9mm .079 to .354 inch:
9 to 20mm .354 to .787 inch:
Min. 20mm .787 inch:
Tolerance
±0.2 ±.008
±0.5 ±.020
±1 ±.039
±1.5 ±.059
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Including discontinued products ( )
HP RELAY ACCESSORIES
TYPES
1. For DIN rail terminal sockets, hold-down clip included.
2. For square hole sockets, powerful hold-down clip included.
Note: Socket and terminal socket conform to UL, CSA as standard.
ACCESSORIES
(Sockets and
Terminal sockets) HP RELAY
Type No. of poles Item Par t No. Packing quantity
Carton Case
Square hole socket 2-pole HP2-square hole socket HP2-SRS 20 pcs. 100 pcs.
3-pole HP3-square hole socket HP3-SRS 10 pcs. 50 pcs.
4-pole HP4-square hole socket HP4-SRS 10 pcs. 50 pcs.
DIN rail terminal socket 2-pole HP2-DIN terminal socket HP2-SFD 10 pcs. 50 pcs.
3-pole HP3-DIN terminal socket HP3-SFD 10 pcs. 50 pcs.
4-pole HP4-DIN terminal socket HP4-SFD 5 pcs. 25 pcs.
Common part 2/3/4-pole (common) HP-hold down clip for socket AW5806 50 pcs.
VDE
Partial approval
Socket for rectangular hold boring Terminal socket for DIN rail assembly
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Compliance with RoHS Directive
HP RELAY ACCESSORIES
DIMENSIONS (Unit: mm inch)
1. Socket for rectangular hold boring (hold-down clip included)
HP2-Socket (HP2-SRS)
External dimensions
General tolerance: ±0.1 ±.004
33
1.299
6
.236
13
.512
38
1.496
1.0
.039
5.5
.217
30
1.181
6.2
.244
.866
22 56
2.205
1.890±.008
48±0.2
.197
5
5
.197
4.1
.161
Front surface mounting
Tolerance: ±0.1 ±.004
1.890±.020
48±0.5
34
1.339
24
.945
2-.165 dia. hole (or 2-M.157 screw hole)
2-4.2 dia. hole (or 2-M4 screw hole)
When the socket is mounted from
the top of the panel (chassis).
Rear surface mounting
Tolerance: ±0.1 ±.004
When the socket is mounted from
below the panel (chassis).
2.047
52
39
1.535
31
1.220
4.2
.165
Mounting dimensions
Notes: 1. Optimum space-saving panel cut-out.
2. Can be mounted from either the front or
the rear of the panel.
3. Hold-down clip is included in package.
Hold-down clip
HP relay
Spring washer
Panel (chassis)
Socket
Hold-down clip
HP relay
Socket
Panel (chassis)
Spring washer
M4 screw
M.157
52±3
2.047±.118
14
.551
53±3
2.087±.118
13
.512
M4 screw
M.157
HP3-Socket (HP3-SRS)
External dimensions
General tolerance: ±0.1 ±.004
30
1.181
38
1.496
5.5
.217
14.5
.571
8
.315
1.0
.039
56
2.205
6.2
.244
45
1.772
4.13.5 3.5
.161.138 .138
22
.866
5
.197
5
.197
48±0.2
1.890±.079
Front surface mounting
Tolerance: ±0.1 ±.004
2-4.2±0.1 dia. hole (or M4 screw hole)
2-.165±.004 dia. hole (or M.157 screw hole)
31 48±0.5
1.890±.020
+1
0
1.220+.039
0
31+1
0
1.220+.039
0
Rear surface mounting
Tolerance: ±0.1 ±.004
(48)
(1.890)
46 4.2
.165
39
2.047
52
+1
0
1.535+.039
0
+1
0
1.811+.039
0
Mounting dimensions
Notes: 1. Optimum space-saving panel cut-out.
2. Can be mounted from either the front or
the rear of the panel.
3. Hold-down clip is included in package.
Hold-down clip
HP relay
Socket
Panel (chassis)
Spring washer
Hold-down clip
HP relay
Socket
Panel (chassis)
Spring washer
M4 screw
M.157
M4 screw
M.157
15.5
.610
52±3
2.047±.118
53±3
2.087±.118
14.5
.571
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Including discontinued products ( )
HP RELAY ACCESSORIES
2. Terminal socket for DIN rail assembly (hold-down clip and installation screw included)
HP4-Socket (HP4-SRS)
External dimensions
General tolerance: ±0.1 ±.004
33
1.299
6
.236
13
.512
5.5
.217
38
1.496
1.0
.039
56
2.205
1.890±.008
48±0.2
58
2.283
22
.866
6.2
.244
4.1
.161
.197
5
5
.197
Front surface mounting
Tolerance: ±0.1 ±.004
2-M4 screw hole (or 4.2±0.1 dia. hole)
2-M.157 screw hole (or .165±.004 dia. hole)
48±0.5
1.890±.020
+.039
0
+1
0
1.339+1
0
34
48+.039
0
1.890
Rear surface mounting
Tolerance: ±0.1 ±.004
2-.165 dia.
2-4.2 dia. hole
48±0.2
1.890±.008
58
25
.984 3
.118
3
3
.118
3.118
.118
1.535
A
+.039
0
39+1
0
+1
0
2.283+.039
0
*When using the former hold-down clip, it is necessary
to cut out the A section marked by the broken line
(not necessary with the powerful hold-down clip).
Mounting dimensions
Notes: 1. Optimum space-saving panel cut-out.
2. Can be mounted from either the front or
the rear of the panel.
3. Hold-down clip is included in package.
Hold-down clip
HP relay
Spring washer
Panel (chassis)
Socket
Hold-down clip
HP relay
Socket
Panel (chassis)
Spring washer
M4 screw
M.157
M4 screw
M.157
52±3
2.047±.118
53±3
2.087±.118
14
.551
13
.512
HP2-Terminal socket for DIN rail assembly (HP2-SFD)
External dimensions
Notes: 1. For direct mounting, use the included installation screw block.
2. A hold-down clip is included with the terminal socket.
30±0.6
1.181±.024
5.8±0.2
.228±.008
69±1
6±.012
6±0.3
2.717±.039
.866±.024
22±0.6
.591±.008
15±0.2
4.1±.012
4.1±0.3
8±0.2
.315±.008
9.5±0.2
.024±.006
0.6±0.15
7.5±0.2
.374±.008
.295±.008
* Installation screw block
(installation screw, hexagonal nut,
spring washer)
Hold-down clip
M.138
M3.5 screw
2.283±.039
58±1
36±1
1.417±.039
33.8±0.6
1.331±.024
37.9±0.6
1.492±.024
80±1
3.150±.039
.394±.024
10±0.6
.937±.024
23.8±0.6
HP2 relay
Schematic
27
1
36
45
8
Mounting hole diagram
Panel hole dimensions
for side-by-side installation
69±0.5
2.717±.020
3030 1.1811.181 4
.866±.008 .866±.008.472±.008
22±0.2 22±0.212±0.2
3.150
80
2-M.157 screw hole
(or .165±.004 dia. hole)
2-M4 screw hole
(or 4.2±0.1 dia. hole)
.157
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Including discontinued products ( )
HP RELAY ACCESSORIES
HP3-Terminal socket for DIN rail assembly (HP3-SFD)
External dimensions
Notes: 1. For direct mounting, use the included installation screw block.
2. A hold-down clip is included with the terminal socket.
Hold-down clip
2.283±.039
58±1
36±1
1.417±.039
33.8±0.6
1.331±.024
37.9±0.6
1.492±.024
80±1
3.150±.039
.394±.024
10±0.6
.937±.024
23.8±0.6
HP3 relay 45±0.6
1.772±.024
5.5±0.2
.217±.008
69±1
2.717±.039
37±0.6
1.457±.024
.236±.012
6±0.3
4.1±0.3
.161±.012
8±0.2
.315±.008
7.65±0.2
.069
±.006
1.75
±0.15
8.5±0.2
.301±.008
.335±.008
M.138
M3.5 screw
* Installation screw block
(installation screw, hexagonal nut,
spring washer)
Schematic
2
1
5
4
7
6
8
9
10
113
Mounting hole diagram
Panel hole dimensions
for side-by-side installation
69±0.5
2.717±.020
4545 1.7721.772 4
.157
1.457±.0081.457±.00812±.008 37±0.237±0.2 12±0.2
3.150
80
2-M.157 screw hole
(or .165±.004 dia. hole)
2-M4 screw hole
(or 4.2±0.1 dia. hole)
HP4-Terminal socket for DIN rail assembly (HP4-SFD)
External dimensions
Notes: 1. For direct mounting, use the included installation screw block.
2. A hold-down clip is included with the terminal socket.
Hold-down clip
M.138
M3.5 screw
2.283±.039
58±1
36±1
1.417±.039
33.8±0.6
37.9±0.6
1.331±.024
1.492±.024
80±1
3.150±.039
.394±.024
10±0.6
.937±.024
23.8±0.6
HP4 relay 25±0.1
.984±.004
10±0.2 10±0.2
.394±.008 .394±.008
61±0.6
2.402±.024
5.8±0.2
.228±.008
69±1
2.717±.039
53±0.6
2.087±.024
.591±.008 .591±.008
15±0.2 15±0.2
.315±.008
8±0.2
.236±.012
6±0.3
4.1±0.3
.161±.012
9.5±0.2
.024±.006
0.6±0.15
7.5±0.2
.374±.008
.295±.008
* Installation screw block
(installation screw, hexagonal nut,
spring washer)
Schematic
1
2
16
11
17
15
10
9
312
45
14 8
67
Mounting hole diagram
Panel hole dimensions
for side-by-side installation
69±0.5
2.717±.020
6161 2.4022.402 4
.157
53±0.2
53±0.2 2.087±.008
2.087±.008 .472±.008
12±0.2
3.150
80
2-M.157 screw hole
(or .165±.004 dia. hole)
2-M4 screw hole
(or 4.2±0.1 dia. hole)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Including discontinued products ( )
HP RELAY ACCESSORIES
NOTES
For Cautions for Use, see Relay Technical Information.
1. There are two types of HP relay: plug-
in and direct mounting (HP2-TM and
HP3-M only).
Avoid use of direct mounting types in
sockets or terminal sockets.
Note: Mounting measurements for direct mounting
types (HP2-TM and HP3-M) are shown in the
drawing on page 146.
2. The terminals are compatible with tab
terminals. Consequently, for direct
mounting types, in addition to soldering,
AMP terminals can be used.
3. When tightening the fixing screws of
direct mounting types, use washers to
prevent damage or distortion.
The optimum torque range is 0.49 to 0.69
N·m, (5 to 7 kgf·cm).
To prevent loosening of direct mounting
types, terminal sock ets and sock ets , etc.,
when fixing the screws, use spring
washers, etc. Moreover, wiring
(soldering), should be done with care
while ensuring strong connections.
4. When tightening terminal socket fixing
screws, to prevent damage, the optimum
torque range should be 0.784 to 0.98
N·m, (8 to 10 kgf·cm).
5. Avoid use in adverse conditions, such
as where the relay will be subjected to
strong vibrations or shoc k, where there is
exposure to harmful gas, or where
ambient temperatures are high (more
than 40°C).
6. Use in DC load
Abnormal wear of the contacts and
contact springs will occur when the
switching frequency is high and there are
large arcs. In particular, if high-frequency
operation in hot or humid conditions is
intended, use arc-suppressing circuits.
7. There is no particular specification for
HP relay mounting orientation.
8. Do not insert or remove relays into or
out of live circuits.
Part number Compatible tab terminal
HP2 #205 series
HP3 #187 series
HP4 #205 series
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.