High Performance RFI Power Line Filters for Medical Equipment
The HT series power line filters provide superior common-
mode and premium differential-mode attenuation to RFI
noise on the frequency range from 10kHz to 30MHz, for
IEC 60601 and UL2601 patient-connected equipment, as
well as all other electronic equipment that cannot tolerate
leakage current.
They are a size- and cost-effective solution to the problem
of meeting both medical leakage current limits and
conducted emissions limits in equipment with high noise
sources (such as switching power supplies). HT series
filters can meet the following Conducted Emissions
standards:
European Normalized Standards based on EN55022,
Level A (in many cases, Level B also).
FCC Part 15, Computing Devices, Class B.
FCC Part 18, ISM Equipment, Industrial and
Consumer.
Note: When using the models with an IEC connector,
remember that the leakage current of the companion line
cord, GA400, is more significant than that of the filter -
which may disqualify this line cord from use in patient care
applications.
For more information on UL2601, see Appendix C.
Specifications
Maximum leakage current,each line-to-ground
@120 VAC 60 Hz: 2µA
@250 VAC 50 Hz: 5µA
Hipot rating (one minute):
line-to-ground 1500 VAC
line-to-line 1450 VDC
Operating frequency: 50/60 Hz
Rated voltage (max.): 250 VAC
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current Frequency–MHz
Rating .01 .02 .05 .08 .15 .5 1 2 5 10 20 30
3A 22 32 36 - 49 46 40 30 22 12 12 12
6A 16 23 32 41 46 41 33 26 15 9 6 2
10A 9 15 24 30 36 42 34 22 11 12 8 8
15A 4 9 18 22 27 41 34 22 12 12 5 2
Line-to-line in 50 ohm circuit
Current Frequency–MHz
Rating .01 .02 .05 .08 .15 .5 1 2 5 10 20 30
3A 3 1 30 - 61 70 65 65 48 40 32 32
6A 4 1 14 45 51 70 70 65 55 47 37 37
10A 7817 32 52 70 70 70 65 55 40 35
15A 12 16 15 10 51 70 70 70 70 70 65 55
70 Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com
Revised 05-07 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com
specified. Values in italics Specifications subject Germany: 49-89-6089-0
are metric equivalents. to change.
HT Series
HT Series
CORCOM Product Guide
Electrical Schematics
3&6Amp
10 Amp
LINE LOAD
LINE LOAD
15 Amp
LINE LOAD
HT1
HT7
HT6
HT3
UL Recognized
CSA Certified
VDE Approved
Resistor location for reference only.
High Performance RFI Power Line Filters for Medical Equipment (Continued)
Case Styles
Recommended Panel Cutout
Case Dimensions
A B C D E
± .015
Part No. (max) (max) (max) (max)
± .38
3EHT1, 6EHT1 3.56 2.15 1.81 2.938 3.38
90.4 54.6 46.0 74.63 85.9
3EHT3, 6EHT3 2.55 2.15 1.81 2.938 3.38
64.8 54.6 46.0 74.63 85.9
3EHT7, 3EHT7M, 3.52 2.25 1.78 1.575 0.63
6EHT7, 6EHT7M 89.4 57.2 45.2 40.01 16.0
10EHT1 4.69 2.27 1.8 4.063 4.47
119.1 57.7 45.7 103.2 113.5
10EHT3 3.69 2.27 1.8 4.063 4.47
93.7 57.7 45.7 103.2 113.5
15EHT1 5.45 3.12 2.18 3.5 3.96
138.4 79.2 55.4 88.9 100.6
15EHT6 5.95 3.12 2.18 3.5 3.96
151.1 79.2 55.4 88.9 100.6
71
Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com
Revised 05-07 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com
specified. Values in italics Specifications subject Germany: 49-89-6089-0
are metric equivalents. to change.
RFI Power Line Filters
HT Series
CORCOM Product Guide
HT1 (3, 6 and 10 Amp)
HT3
HT1 (15 Amp)
HT6
B
C
D
A
E
Typical dimensions:
Terminals: .250 [6.35](5) Holes: .07 [1.8 ]Dia.(4) Slot: .07 x .16 [1.8 x 4.1 ]
Mounting holes: .188 [4.78 ]Dia. (2)
Typical dimensions:
Wire leads: 4.0 [101.6 ]Min. Mounting holes: .188 [4.78 ]Dia. (2)
Typical dimensions:
Terminals: No. 8-32 (5) Mounting holes: .203 x .156 [5.16 x 3.96 ]Dia. (4)
Torque: 18±2 in.lb
Brown
Green/Yellow
Blue
Blue
Brown
A
D
E
C
B
EDB
A
2.00±.01
50.80±.25
C
EDB
C
2.00±.01
50.80±.25
A
±.02 [±.5]
Part Numbers
6EHT1 10EHT1
6EHT3 10EHT3
6EHT7 15EHT1
6EHT7M 15EHT6
Line Cord No. GA400
71/2 foot, 3-conductor line cord to mate with T7 models
HT7 & HT7M (with metric insert)
BD
ECA
1.575
40.01
0.910
23.1
0.157
3.98 Dia.
0.235
5.96 R
1.295
32.89
Panel Cutout (back mount)
Tolerance ±.005 [0.13]
Tapped insert
No. 6-32 x 1/4 (2) - T7
No. M-3 x 5 (2) - T7M
Typical dimensions:
Terminals: .250 [6.35](5) Holes: .07 [1.8 ]Dia.(4) Slot: .07 x .16 [1.8 x 4.1 ]
Mounting holes: .203 x .156 [5.16 x 3.96 ]Dia. (4)