Specifications
Supply Voltage and Current
90 to 250 V ac (50/60 Hz)
Average current 20 mA
Peak current 500 mA at 120 V ac, 750 mA at 250 V ac
Supply Protection Circuitry
Protected against transient voltages
Output Configuration
SPDT (Single-Pole Double-Throw) electromechanical relay output. All
models except emitters.
Output Rating
Max. switching power (resistive load): 150 W, 600 VA
Max. switching voltage (resistive load): 250 V ac, 30 V dc
Max. switching current (resistive load): 5 A at 250 V ac
Min. voltage and current: 5 V dc, 0.1 mA
Mechanical life of relay: 10,000,000 operations
Electrical life of relay at full resistive load: 100,000 operations
Output Protection Circuitry
Protected against false pulse on power-up
Output Response Time
15 milliseconds ON and OFF
(NOTE: 100 millisecond delay on power-up. Output is de-energized
during this time.)
Environmental Rating
NEMA 6P, IEC IP67
Operating Conditions
Temperature: –40 °C to 70 °C (–40 °F to 158 °F)
Maximum relative humidity: 90% at 50 °C (non-condensing)
Certifications
Repeatability
Opposed mode: 0.25 milliseconds
All other sensing modes: 0.5 milliseconds
Response time and repeatability specifications are independent of
signal strength.
Adjustments
Light/Dark Operate select switch and multi-turn Sensitivity control
(allows precise sensitivity setting – turn clockwise to increase gain).
Optional logic and logic/display modules have adjustable timing
functions.
Indicators
Indicator LEDs are clearly visible beneath a raised transparent Lexan®
dome on top of the sensor
Power (green) LED lights when 90 to 250 V ac power is applied
Signal (red) AID™ System LED lights when the sensor sees its
modulated light source and pulses at a rate proportional to the strength
of the received light signal
Load (amber) LED lights whenever the output relay is energized
Optional 7-element LED signal strength display modules
Construction
Molded reinforced thermoplastic polyester housing, o-ring-sealed
transparent polycarbonate cover, molded acrylic lenses, and stainless
steel hardware. Q45s are designed to withstand 1200 psi washdown.
The base of cabled models has a 1/2-inch NPS integral internal conduit
thread.
Connections
PVC-jacketed 2-wire (emitters) or 5-wire (all others) 2 m (6.5 ft) or 9
m (30 ft) unterminated cables, or 3-pin (emitters) or 5-pin (all others)
Mini-style quick-disconnect (QD) fittings are available (“Q” - suffix
models).
QD cables are ordered separately.
Application Notes
Transient suppression is recommended for contacts switching inductive
loads.
Optional output timing modules are available.
Dimensions
Opposed, Retro, and Diffuse Sensing Modes (Model Suffix E, R, D, DL, DX, LP, and LV)
Cabled Models Quick-Disconnect Models
54.1 mm
(2.13")
44.5 mm
(1.75")
69.0 mm
(2.72")
87.6 mm
(3.45")
Internal Thread
(1/2–14NPSM)
30.0 mm
(1.18")
ø 6.1 (0.24")
2m (6.5') Cable
7.1 mm
(0.28")
4.5 mm (#10) Screw
Clearance (2)
50.8 mm
(2.00")
6.4 mm (0.25")
Lens Centerline
Transparent Cover (Gasketed)
View: Output Load Status
Open to Access: Sensitivity (Gain)
Adjustment
External thread (M30 x 1.5)
hex nut supplied
External Thread
M30 X 1.5
Mini-style QD Connector
14 mm (0.6")
Q45VR2 Series Sensors
P/N 36339 Rev. F www.bannerengineering.com - Tel: +1-763-544-3164 7