Selection
Guide
Fibers
Fiber
Ampliers
Other Products
FX-300
FX-311
FX-301-F7/
FX-301-F
FX-11A
FX2
FX-CH2
FX-CH
The FX-301-F7 (Note 1) dedicated for the leak detection ber FD-F71
and the FX-301-F dedicated for the liquid detection ber FT-F93 are
available. Optimal setting is possible with easy operation.
Note: The FX-301-F can be also used by setting it to leak detection mode. However, the
functions are different from the FX-301-F7 dedicated for the leak detection ber,
so it is recommended to use the FX-301-F7 when using the leak detection ber.
PNP output
type available
Light intensity
monitor
Timer
A
utomatic
sensitivity setting
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only
FX-301-F7 FX-301-F
Easy operation even for beginners!
Optimum settings can be realized with simple operations
For use with leak detection or liquid detection ber only
Leak detection fiber
FD-F71
Liquid detection fiber
FT-F93
Flashing function incorporated
When the leak detection ber is connected (F7 mode), if
a leak is detected, you will recognize which ber detects
the leak at a single glance because the emitter will start
ashing.
Main cable
Sub cable
Easy maintenance, as main and sub units are identical
Both main and sub units utilize the same amplier body. This
feature allows for easy mounting in the side-by-side conguration.
The main and sub unit
functions are distinguished
only by the proper use of
3-core main cable and the
1-core sub cable.
Moreover, by utilizing the same
body for both main and sub
units, inventory management
and maintenance is simplied.
The newly developed “four-chemical emitting element
used for FX-301-F7 / FX-301-F can suppress the
secular change of the light emitting element to minimum,
allowing stable detection for long period of time.
Long life and stable operational settings due
to the newly developed emitting element
General terms and conditions ............. F-3
Selection guide
……………………… P.3~
Dedicated amplifier for the
leak detection fiber
FX-301-F7
Dedicated amplifier for the
liquid detection fiber
FX-301-F
Sets the optimal threshold value
FX-301-F7
Threshold value will
be set automatically to
-20 % of the incident
light intensity during
the teaching to steadily
detect the leak. It is also
possible to change the
threshold value to -15 %
or -30 %.
Threshold follow-up function FX-301-F7
Incident light intensity is
checked at regular time
interval (10 min.), and
threshold value is reset
automatically.
(During teaching)
-15 %
-20 %
-30 %
Incident light
intensity
(At the time of factory shipment)
Threshold value
Incident light intensity
Time
Incident light intensity
Incident
light
intensity
(Current value)
Threshold
value
*Function is set to OFF at the time of factory shipment.
panasonic.net/id/pidsx/global
Glossary of terms / General precautions....P.1549~ / P.1552~
Korea's S-mark ............................. P.1602
Recognition
Certified
(FX-301-F only)
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F
158
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Fibers
Fiber
Ampliers
Other Products
FX-300
FX-311
FX-301-F7/
FX-301-F
FX-11A
FX2
FX-CH2
FX-CH
Capillarity effect
Leakage pan
Liquid
Fiber head
Optimal threshold value is set automatically on
FX-301-F7 just by setting the MODE indicator to “TEACH”
and pressing the jog switch.
Teaching is performed collectively for all the connected
ampliers with an optical communication function when
the MODE indicator is set to “ALL”. Each amplier will be
set with an optimal threshold value.
Easy to operate with individual / collective teaching mode
Individual teaching mode (TEACH) Collective teaching mode (ALL)
Communication direction
Collective teaching mode is possible for 16 units max.
Low prole liquid detection ber with high chemical resistance
SEMI S2 compliant!
Leak detection ber cannot be used in combination
with the FX-100/300/311/410 series.
The unique effect of capillarity enables reliable detection
of small leaks and viscous liquids.
Stable detection performance
LEAK DETECTION FIBER (FD-F71)
Compact, space-saving
This slim (10 mm 0.394 in) side-mounting ber head is
especially good for use in conned spaces.
Labor-saving design
Because all you need to install is one screw, one-touch
mounting of the ber head is possible.
Replacement parts even for resetting after a leak are
unnecessary.
Because the ber head is simply designed, wiping off
leaks is rendered easy.
FD-F71
Superb explosion resistance / chemical resistance
Explosion resistance is enhanced by adopting the ber
method (SEMI S2 compliant). The head unit made
of uorocarbon polymers also has superb chemical
resistance.
The threshold value is set after selecting the liquid
detection ber for FX-301-F.At the same time, other setting in the master unit will
be copied to the slave unit.
Amplier Built-in Leak Detection Sensor
High-speed detection
even a little liquid leak
EX-F70 SERIES
EX-F60 SERIES
P. 877
159
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Fiber
Ampliers
Other
Products
FX-300
FX-311
FX-301-F7/
FX-301-F
FX-11A
FX2
FX-CH2
FX-CH
ORDER GUIDE
Ampliers Quick-connection cable is not supplied with the amplier. Please order it separately.
Quick-connection cables Quick-connection cable is not supplied with the amplier. Please order it separately.
Type Model No. Description
Main cable
(3-core)
CN-73-C1
Length: 1 m 3.281 ft
0.2 mm2 3-core cabtyre cable, with
connector on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-73-C2
Length: 2 m 6.562 ft
CN-73-C5
Length: 5 m 16.404 ft
Sub cable
(1-core)
CN-71-C1
Length: 1 m 3.281 ft
0.2 mm2 1-core cabtyre cable, with
connector on one end
Cable outer diameter: ø3.3 mm ø0.130 in
CN-71-C2
Length: 2 m 6.562 ft
CN-71-C5
Length: 5 m 16.404 ft
Main cable
• CN-73-C
Sub cable
• CN-71-C
Type Appearance Model No. Emitting element Output
Leak
detection
ber only
NPN output FX-301-F7
Red LED
NPN open-collector transistor
PNP output FX-301P-F7 PNP open-collector transistor
Liquid
detection
ber only
NPN output FX-301-F
Red LED
NPN open-collector transistor
PNP output FX-301P-F PNP open-collector transistor
LIQUID DETECTION FIBER (PIPE-MOUNTABLE) (FT-F93)
Stable design that doesn’t permit liquid-absent or
sensor errors
When liquid is present, its effect on the lens causes
light to focus and enter.
Because there is no electric circuitry in the ber head, it
boasts excellent explosion resistance.
Superior explosion resistance compatible to SEMI S2
Even when the shape and thickness of the pipe vary, this
ber head uses a method where the beam axis follows
the diameter of the pipe, and so when compared to
conventional methods, the shape and thickness of the
pipe have no inuence over the performance of this ber
head.
Easy to use and reliable detection
When abnormalities such as a severed or removed
ber or a cutoff cable occur, light does not enter and the
sensor will output the same as “liquid-absent”.
Reliable detection not affected by bubbles or droplets
Latest optical ber techniques have solved problems
caused by bubbles, droplets or liquid leakage that arise
in conventional pipe-mountable ber heads.
Stably detect the liquid inside the pipe!
SEMI S2 compliant!
Leak detection ber cannot be used in combination
with the FX-100/300/311/410 series.
Low
Beam-receiving signal
Zero
When the fiber cable is severed
Severed!
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F
160
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Fiber
Ampliers
Other
Products
FX-300
FX-311
FX-301-F7/
FX-301-F
FX-11A
FX2
FX-CH2
FX-CH
ORDER GUIDE
End plates End plates are not supplied with the amplier. Please order it separately when the ampliers are mounted in cascade.
Appearance Model No. Description
MS-DIN-E
When ampliers are mounted in cascade, or when
an amplier moves depending on the way it is
installed on a DIN rail, these end plates clamp
ampliers into place on both sides. Make sure to
use end plates when cascading multiple ampliers
together.
2 pcs. per set
Designation Model No. Description
Amplier
mounting bracket
MS-DIN-2 Mounting bracket for amplier
Fiber sensor
amplier
protection seal
FX-MB1
10 sets of 2 communication window seals and 1 connector seal
Communication window seal:
It prevents malfunction due to transmission signal from another
amplier, as well as, prevents effect on another amplier.
Connector seal:
It prevents contact of any metal, etc., with the pins of the quick-
connection cable.
OPTIONS
Amplier mounting bracket
• MS-DIN-2
Fiber sensor amplier protection seal
• FX-MB1
Connector seal
Communication
window seal
Fiber heads
About the handling of the ber cable length changed product
The type with ber cable length changed is prepared as a semi-custom product with fast response.
Please contact the sales regarding the model name, standard price, and delivery.
Applicable ber cable length: Up to 25 m 82.021 ft, in 1 m 3.281 ft intervals.
Applicable protective tube length: Up to 10 m 32.808 ft, in 0.5 m 1.641 ft intervals.
Accessories
FX-CT2 (Fiber cutter)
FX-AT4 (Attachment for ø1 mm ø0.039 in ber, black)
MS-FD-F7-1 (SUS mounting bracket for FD-F71)
MS-FD-F7-2 (PVC mounting bracket for FD-F71)
FX-CT2 FX-AT4 MS-FD-F7-1
(SUS mounting bracket for FD-F71)
MS-FD-F7-2
(PVC mounting bracket for FD-F71)
Designation
Shape of ber head
(mm in)
Model No.
Bending
radius
(mm)
Fiber cable length
:
Free-cut Description
Protection
Ambient
temp.
Dimensions
Leak
detection
ber
SEMI S2 compliant
W20 × H30 × D10
W0.787 × H1.181 × D0.394
FD-F71
R4
5 m
16.405 ft
Liquid leak detection
Leak absent: Beam received,
Leak present: Beam not received
Dedicated amplier for the leak detection ber :
FX-301-F7
IP67
−20 to
+60 °C
−4 to
+140 °F
P. 68
Liquid
detection
ber
SEMI S2 compliant
W23 × H20 × D17
W0.906 × H0.787 × D0.669
FT-F93
Protective
tube
R20
Fiber
R2
2 m
6.562 ft
Applicable pipe diameter:
Outer dia. ø3 to ø10 mm
ø0.118 to ø0.394 in Transparent pipe
PFA (uorine resin) or equivalently transparent pipe,
wall thickness 0.3 to 1.0 mm 0.012 to 0.039 in
Liquid absent: Beam not received,
Liquid present: Beam received
Dedicated amplier for the liquid detection ber :
FX-301-F
IP40
−40 to
+60 °C
−40 to
+140 °F
P. 58
Bending durability
Bending durability
: Refers to a ber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°)
and more exible (bending radius: R4 mm R0.157 in or less) features.
: Refers to a ber which possesses unbreakable bending-resistant feature (bending radius: R10 mm R0.394 in,
reciprocating bending: 180°).
Bending durability
161
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Fiber
Ampliers
Other
Products
FX-300
FX-311
FX-301-F7/
FX-301-F
FX-11A
FX2
FX-CH2
FX-CH
DIMENSIONS (Unit: mm in)The CAD data can be downloaded from our website.
FX-301(P)-F7 FX-301(P)-F Amplier
48.2
1.898
27.8
1.094
10.5
0.413
3.95
0.156
3
0.118
7
0.276
64.5 2.539
12
0.472
0.7
MODE key
Operation indicator (Orange)
Digital display (Red)
Communication
window
Beam-
emitting
part
Beam-
receiving
part
Jog switch
Suitable for 35 mm 1.378 in
width DIN rail
0.028
26.3
1.035
8.3
0.327
3
0.118
10
0.394
36.5
1.437
13.5
0.531
3
0.118
30.5
1.201
7 0.276
7 0.276
2.5
0.098
FX-301
(P)-F7:
A
utomatic follow-up function indicator
FX-301
(P)-F:
Model indicator
(Green) (Note 1)
Main cable (Optional)
CN-73-C□ Sub cable (Optional)
CN-71-C□
3
0.1
18
7.2
0.283
13.6
0.535
10
0.394
0.2
0.008
10.5
0.413
14
0.551 2.9
0.114
10
L
ø3.3 ø0.130 cable
0.394
6
0.236
2.54
0.100
2.54
0.100
2.65
0.104
7
0.276
2.9
0.114
ø3.3 ø0.130 cable
10
L
0.394
6
0.236
3
0.1
18
7.2
0.283
13.6
0.535
10
0.394
7
0.276
0.2
0.008
10.5
0.413
2.54
0.100
2.54
0.100
2.65
0.104
14
0.551
Length L
Model No. Length L
CN-71-C1 1,000 39.390
CN-71-C2 2,000 78.740
CN-71-C5 5,000 196.850
Length L
Model No. Length L
CN-73-C1 1,000 39.390
CN-73-C2 2,000 78.740
CN-73-C5 5,000 196.850
Amplier mounting bracket (Optional)
MS-DIN-2
21.6
0.850
5.2
0.205
8.5
0.335
3.2
0.126
16
0.630
3.2
0.126
10
0.394
5
0.197
35
1.378
0.4
0.016
7.5
0.295
2
0.079
27
1.063
t 1
t 0.039
2
0.079
4.2 0.165
5.2
0.205
ø1.8
2-ø3.2 ø0.126 holes
ø0.071
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
End plates (Optional)
MS-DIN-E
2.75
0.108
4
0.157
3
0.118
M3 (length 18 mm 0.709 in) pan head screws
M3 square nut
5.6
0.220
24.7
0.972
1.6
0.063
32
1.260
60
2.362
15
0.591
3
0.1
18
Suitable for 35 mm 1.378 in width DIN rail
Material: Polycarbonate
Note: Above gure is an external dimension drawing of the FX-301(P)-F7. Shape of the indicator for FX-301(P)-F is little different.
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F
162
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Fibers
Fiber
Ampliers
Other
Products
FX-300
FX-311
FX-301-F7/
FX-301-F
FX-11A
FX2
FX-CH2
FX-CH
DIMENSIONS (Unit: mm in)The CAD data can be downloaded from our website.
Beam-receiving side
(Black)
Beam-emitting side
(Gray)
7.2 0.283
5.5 0.217
ø0.25 ø0.010 × 4 fiber core (PMMA)
Sheath ø1 ø0.039 (Polyethylene)
ø3.1 ø0.122 Protective tube [PFA(Fluorine resin)]
Enclosure
(ABS)
6 0.236
2-ø1 ø0.039
ø3.1 ø0.122
10.3 0.406 6 0.236
FT-F93
20 0.787
2,000 78.740
12
0.472
1,000
39.370
23
0.906
9 0.354
17
0.669
<with FX-AT4>
FT-F93 Free-cut
FD-F71 Free-cut
<with FX-AT4>
[PFA(Fluorine resin)]
10
0.394
7.8 0.307
ø0.25 ø0.010 fiber core × 4 (PMMA)
Outer sheath ø1 ø0.039 (Polyethylene)
(ø3.1) (ø0.122) Protective tube
[PFA(Fluorine resin)]
Beam-emitting side
(Gray)
Beam-receiving side
(Black)
Emission indicator 30 1.181
5,000 196.850
20
0.787
3,000 118.110
10
0.394
22 0.866
FD-F71
2-ø1
ø0.039
Fiber
SUS mounting bracket
(MS-FD-F7-1) SUS mounting bracket
mounting diagram
15
0.591
11.5
0.453
10
0.394
30 1.181
6.2 0.244
FD-F71
SUS mounting bracket
0.3
0.012
5.5 0.217
12.2 0.480
17
0.669
10
0.394
17.7
0.697
11 0.433
ø4.2 ø0.165 thru-holes
Material: [PFA(Fluorine resin)]
Material: Stainless steel (SUS316)
10.3 0.406
0.3 0.012
PVC mounting bracket
(MS-FD-F7-2)
Welding part
Material: PVC
11.5
0.453
10
0.394
25
0.984
30 1.181
FD-F71
PVC mounting bracket
10 0.394
4 0.157
12
0.472
11
0.433
5.7
0.224
15.5
0.610
10
0.394
10.5 0.413
PVC mounting bracket
mounting diagram