BTCPower TM Broadband TelCom Power, Inc. RPM800 Series Redefining "Current" Limits In Power Conversion Front-End Rectifier Power Module Description The RPM800 front-end rectifier power module provides up to 700 watt of power in a low-profile 1U high package to convert universal AC mains voltage to isolated, regulated 48 or 24 VDC for use in distributed power applications. The power module has selfcontained cooling fans, an input EMC line filter, integrated power entry receptacle and output power connector. It can be used as a stand-alone module for integration within a user's system or with an accompanying RPS2400 series Front-End Rectifier Shelf. For applications that require N+1, fault-tolerant, redundant power, up to three RPM800 power modules can be used with a RPS2400 Rectifier Power Shelf. See RPS2400 product specifications for configuring a scalable, fault-tolerant redundant front-end power solution. Features * * * * * * * 700 W of output power Universal input for worldwide mains power Power Factor Corrected to EN61000 EN55022 Level A conducted EMI filter Low profile of only 1.63 inch high Small depth of only 11.52 inches deep Power Good LED on front panel * Active load-current sharing * Hot insertion/removal * Integrated isolation diodes for fault-tolerant applications * Fault signal for remote monitoring Applications * * * * * * * Telecommunications Data Communications Wireless Communications Networking Gear Servers, Switches and Data Storage Semiconductor Test Equipment Distributed Power Architecture Specification Summary * 14.6A @ 48V (RPM800-48), 29A @ 24V ( RPM800-24) * Tightly output regulation, typical 1% * No minimum load required * Ripple & Noise ( 20Mhz BW) 5% (pk-pk) * Wide input operating range 85~264Vac * Enable pin control * Current share accuracy at 10% * 85% Efficiency * Inrush current limits at 30A * Output overcurrent and overvoltage protection * Over Temperature protection * Input Under voltage protection * MTBF of 1,300,000 hours @ 50C ( Bellcore ) Broadband TelCom Power, Inc. - 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. Tel.: 714-259-4888 * Fax: 714-259-0840 * www.btcpower.com * Email: sales@btcpower.com PB RPM800 Rev3 16-1-04 RPM800 BTCPower TM Series Front-End Rectifier Power Module Product Brief Part Number, Selection and Specification Information Input Model Part Number Voltage (Volts) Output Current (A) Efficiency Voltage Current 75% Load Nominal No load Full load (Volts) (Amps) (%) RPM800-48 115/230 0.3 8.2/4.0 48 14.6 82/85 RPM800-24 115/230 0.3 8.5/4.1 24 29.0 80/83 Typical at Ta= +25 C under nominal line voltage and 75% load conditions, unless noted. Consult factory for other output voltage configurations Output Power, maximum ................................................................700 watts Output Voltage...................................................................48 or 24 V Line regulation ..........................................................................+/-1% Load regulation.........................................................................+/-1% Ripple/noise (peak-to-peak 20 MHz).........................................+/-1% Dynamic response................................................................... 500uS Temperature coefficient................................................0.02%/deg. C Minimum load...............................................................None required Overload protection (auto-recovery).......................................... 115% Overvoltage protection (latching).............................................. 125% Overtemperature protection ...............110 deg C internal case temp. Overtemperature warning................................................................... ....................................100 deg C internal case temp., open collector Set-point accuracy ....................................................................+/-1% Load-current share accuracy ..................................................+/-10% Power Good signal ..................................................... Open collector Enable input...............................Low: PSU on, high or open: PSU off Input Input Voltage range:......................................................... 85-264VAC Input Frequency....................................................................47-63Hz Power Factor................................................................................>0.9 Inrush current limiting........................................................ <30A peak Input current at full output load........... 4A @ 230VAC, 9A @ 115VAC Input EMC filter, conducted.....................................EN55022 Level A Harmonic Distortion ...................................................... EN61000-3-2 Input Immunity, conducted................................................EN55082-1 Input protection.................. Internal fuse, 15A slow blow, size 5x20m General Efficiency.......................................85% at 220VAC, 82% at 110VAC Environmental Operation ambient temperature...................-20 deg. C to +70 deg. C Output pow er de-rating..................-1.43%/ deg. C above +35 deg. C Storage temperature....................................-40 deg. C to +85 deg. C Cooling..........................................3 self-contained, ball-bearing fans Airflow direction.......................................................From front to rear Outline Information and Pin-out The information and specifications contained in this brief are believed to be accurate and reliable at the time of publication. Broadband TelCom Power, Inc. - 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. Tel.: 714-259-4888 * Fax: 714-259-0840 * www.btcpower.com * Email: sales@btcpower.com PB RPM800 Rev3 16-1-04