Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
DJ (ADJ)
ASCTB176E 201202-T
RATING
1. Coil data
1) Single side stable
2) 1 coil latching
3) 2 coil latching
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. In order to obtain the full rated life cycles, the relay should be properly vented by removing the vent nib. More detail, please look at caution for NOTES.
*4. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
Nominal coil voltage Pick-up voltage
(at 20°C 68°F)Drop-out voltage
(at 20°C 68°F)Coil resistance
[±10%] (at 20°C 68°F)Nominal operating power Max. applied voltage
(at 20°C 68°F)
5V DC
75%V or less of nominal
voltage (Initial) 10%V or more of nominal
voltage (Initial)
100Ω
250mW 130%V of nominal voltage
6V DC 144Ω
12V DC 576Ω
24V DC 2,304Ω
48V DC 9,216Ω
Nominal coil voltage Set voltage
(at 20°C 68°F)Reset voltage
(at 20°C 68°F)Coil resistance
[±10%] (at 20°C 68°F)Nominal operating power Max. applied voltage
(at 20°C 68°F)
5V DC
70%V or less of nominal
voltage (Initial) 70%V or less of nominal
voltage (Initial)
167Ω
150mW 130%V of nominal voltage
6V DC 240Ω
12V DC 960Ω
24V DC 3,840Ω
48V DC 15,360Ω
Nominal coil voltage Set voltage
(at 20°C 68°F)Reset voltage
(at 20°C 68°F)Coil resistance
[±10%] (at 20°C 68°F)Nominal operating power Max. applied voltage
(at 20°C 68°F)
5V DC
70%V or less of nominal
voltage (Initial) 70%V or less of nominal
voltage (Initial)
100Ω
250mW 130%V of nominal voltage
6V DC 144Ω
12V DC 576Ω
24V DC 2,304Ω
48V DC 9,216Ω
Characteristics Item Specifications
Contact
Arrangement 1 Form C, 1 Form A, 1 Form B, 1 Form A 1 Form B, 2 Form C, 2 Form A, 2 Form B
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material AgSnO2 type (1 Form C, 1 Form A, 1 Form B),
Au-flashed AgSnO2 type (1 Form A 1 Form B, 2 Form C, 2 Form A, 2 Form B)
Rating
Nominal switching capacity (resistive load) 16 A 250V AC (1 Form C, 1 Form A, 1 Form B),
10 A 250V AC (2 Form C, 2 Form A, 2 Form B, 1 Form A 1 Form B)
Max. switching power (resistive load) 4,000 V A
Max. switching voltage 250V AC
Max. switching current 16 A (1 Form C, 1 Form A, 1 Form B),
10 A (1 Form A 1 Form B, 2 Form C, 2 Form A, 2 Form B)
Nominal operating power 150mW (1 coil latching), 250mW (Single side stable, 2 coil latching)
Min. switching capacity (Reference value)*1100mA 5 V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdo wn voltage” section.
Breakdown voltage
(Initial) Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA.)
Between contact and coil 4,000 Vrms for 1min. (Detection current: 10mA.)
Surge breakdown
voltage*2 (Initial) Between contact and coil Min. 10,000 V
Temperature rise (coil) (at 70°C 158°F)Max. 55°C (By resistive method, nominal voltage applied to the coil, max. switching current.)
Operate time [Set time] (at 20°C 68°F) Max. 20 ms [20 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20°C 68°F) Max. 20 ms [20 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)
Mechanical
characteristics
Shock resistance Functional Min. 200 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Destructive Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 2 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 3 mm
Expected life Mechanical Min. 5×106 (at 180 times/min.)
Electrical (Resistive load)*3 (at 20 times/min.) Min. 105 (at 16A 250V AC): 1 Form C, 1 Form A, 1 Form B
Min. 105 (at 10A 250V AC): 2 Form C, 2 Form A, 2 Form B, 1 Form A 1 Form B
Conditions Conditions for operation, transport and storage*4Ambient temperature: –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight Approx. 14 g .49 oz