ACDC
Specification
120180 Watts
Convectioncooled
3” x 5” Footprint
Up to 90% Efficiency
Open Frame, UChannel & Covered Versions
Low Temperature Option
Single & Multi Outputs
3 Year Warranty
SDS Series
Input
Input Voltage 90-264 VAC (120-370 VDC)
Input Frequency 47-63 Hz
Input Current 120 W: 1.7 /1.0 A max at 115 /230 VAC
150 W: 2.0 /0.8 A max at 115 /230 VAC
180 W: 2.7 A max at 90 VAC
Inrush Current 120 W: 20 /51 A max at 115 /230 VAC
150 W: 54 /63 A max at 115 /230 VAC
180 W: 54 /108 A max at 115 /230 VAC
Power Factor >0.9
Earth Leakage Current 120 W: 0.30 /0.75 mA at 115 /230 VAC
150 W: 0.40 /0.75 mA at 115 /230 VAC
180 W: 0.75 mA at 230 VAC
Input Protection Internal T3.15 A /250 VAC fuse in line
No Load Input Power 180 W: <0.5 W
Output
Output Voltage See table
Output Voltage Trim ±5% output 1 only (3.3 V variant ±10%)
SDS180: not user adjustable
Initial Set Accuracy Single output models: ±1%
Multi-output models: ±5%
Minimum Load No minimum load required for single
output models. For multi-output models
(see table)
Start Up Delay 2 s max
Start Up Rise Time 2 ms typical
Hold Up Time 16 ms minimum at full load and 110 VAC
Line Regulation 0.5% typical
Load Regulation 3.0% typical
Transient Response 4% max deviation, recovery to within
1% in 500 µs for a 50% load change
Ripple & Noise 1% pk-pk typical, 20 MHz bandwidth
Overvoltage Protection 112-132% V1 only, recycle input to reset
Overload Protection All outputs: 110-150% with auto recovery
(primary power limit)
Short Circuit Protection Trip & restart (hiccup mode),
auto recovery
Temperature ±0.04%/°C
Coefficient
xppower.com
General
Efficiency 120 W: 80% typical
150 W and 180 W: 88% typical
Isolation 3000 VAC Input to Output, 1500 VAC
Input to Ground, 500 VDC Output to
Ground
Isolation Resistance 50 M
Switching Frequency 120 W: PFC 100 kHz typical, PWM 67 kHz
typical. 150 W: PFC 34 kHz minimum,
PWM 55 kHz typical. 180 W: PFC 67 kHz
typical, PWM 67 kHz typical
Power Density 120 W: 4.87 W/In3, 150 W: 6.50 W/In3
180 W: 7.47 W/In3
Signals Power Fail Detect = TTL active low,
combined AC and DC OK signal
(-P versions SDS120 & 150 only)
Warning time 16 ms
MTBF >130 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature 0 °C to +70 °C (-20 °C to +70 °C, SDS180),
derate linearly from 100% load at +50 °C
to 50% load at +70 °C,
for low temperature option add suffix -L:
-40 °C to +70 °C, SDS120 and SDS150,
not available for SDS180
Cooling Convection-cooled
Operating Humidity 5-95% RH, non-condensing
Storage Temperature -40 °C to +85 °C
EMC & Safety
Emissions EN55022, level B conducted & radiated.
Harmonic Currents EN61000-3-2 class A
Voltage Flicker EN61000-3-3
ESD Immunity EN61000-4-2, level 2 contact, Perf Criteria A
SDS150: level 3 air, Perf criteria A
Radiated Immunity EN61000-4-3, level 2, Perf Criteria A
EFT/Burst EN61000-4-4, level 2, Perf Criteria A
Surge EN61000-4-5, installation class 3,
Perf Criteria A
Conducted Immunity EN61000-4-6, level 2 , Perf Criteria A
Magnetic Field EN61000-4-8, 1 A/m, Perf Criteria A
Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms,
>95% 5000 ms Perf Criteria A, B, B
Safety Approvals EN60950-1, UL60950-1,CSA60950-1
per cUL.
ACDC
SDS120
Mechanical Details
Models and Ratings
Output
Power
Output 1 Output 2 Output 3 Model Number(2, 4, 5)
Vnom Imin Imax Tol.(1) Vnom Imin Imax Tol.(1) Vnom Imin Imax Tol.(1)
72.0 W 3.3 V 0.00 A 22.00 A 5% SDS120PS03B
110.0 W 5.0 V 0.00 A 22.00 A 5% SDS120PS05B
115.0 W 7.0 V 0.00 A 16.42 A 5% SDS120PS07B
120.0 W 9.0 V 0.00 A 13.33 A 4% SDS120PS09B
120.0 W 12.0 V 0.00 A 10.00 A 3% SDS120PS12B
120.0 W 15.0 V 0.00 A 8.00 A 3% SDS120PS15B
120.0 W 18.0 V 0.00 A 6.66 A 3% SDS120PS18B
120.0 W 24.0 V 0.00 A 5.00 A 2% SDS120PS24B
120.0 W 28.0 V 0.00 A 4.28 A 2% SDS120PS28B
120.0 W 36.0 V 0.00 A 3.33 A 2% SDS120PS36B
120.0 W 48.0 V 0.00 A 2.50 A 2% SDS120PS48B
79.5 W +3.3 V 1.50 A 15.00 A 5% +5.0 V 0.40 A 6.0 A 5% SDS120PD00B
120.0 W +3.3 V 1.50 A 15.00 A 5% +12.0 V 0.20 A 6.0 A 5% SDS120PD01B
120.0 W +5.0 V 1.50 A 15.00 A 5% +12.0 V 0.20 A 6.0 A 5% SDS120PD02B
120.0 W +5.0 V 1.50 A 15.00 A 5% +15.0 V 0.20 A 6.0 A 5% SDS120PD03B
120.0 W +5.0 V 1.50 A 15.00 A 5% +24.0 V 0.10 A 3.5 A 5% SDS120PD04B
120.0 W +5.0 V 1.50 A 15.00 A 5% -24.0 V 0.20 A 2.0 A 5% SDS120PD05B
120.0 W +28.0 V 0.39 A 3.92 A 5% +5.0 V 0.20 A 2.0 A 5% SDS120PD06B
91.5 W +3.3 V 1.50 A 15.00 A 5% +5.0 V 0.60 A 6.0 A 5% +12.0 V 0.00 A 1.0 A 5% SDS120PT00B
91.5 W +3.3 V 1.50 A 15.00 A 5% +5.0 V 0.60 A 6.0 A 5% -12.0 V 0.00 A 1.0 A 5% SDS120PT01B
120.0 W +3.3 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% +5.0 V 0.00 A 0.8 A 5% SDS120PT02B
120.0 W +3.3 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% -5.0 V 0.00 A 0.8 A 5% SDS120PT03B
120.0 W +3.3 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% -12.0 V 0.00 A 0.8 A 5% SDS120PT04B
120.0 W +3.3 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% +12.0 V 0.00 A 0.8 A 5% SDS120PT05B
120.0 W +5.0 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% +5.0 V 0.00 A 0.8 A 5% SDS120PT06B
120.0 W +5.0 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% -5.0 V 0.00 A 0.8 A 5% SDS120PT07B
120.0 W +5.0 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% -12.0 V 0.00 A 0.8 A 5% SDS120PT08B
120.0 W +5.0 V 1.50 A 15.00 A 5% +12.0 V 0.60 A 6.0 A 5% +12.0 V 0.00 A 0.8 A 5% SDS120PT09B
120.0 W +5.0 V 1.50 A 15.00 A 5% +15.0 V 0.60 A 6.0 A 5% -15.0 V 0.00 A 0.8 A 5% SDS120PT10B
120.0 W +5.0 V 1.50 A 15.00 A 5% +15.0 V 0.60 A 6.0 A 5% +15.0 V 0.00 A 0.8 A 5% SDS120PT11B
120.0 W +5.0 V 1.50 A 15.00 A 5% +24.0 V 0.35 A 3.5 A 5% -24.0 V 0.00 A 0.8 A 5% SDS120PT12B
120.0 W +5.0 V 1.50 A 15.00 A 5% +24.0 V 0.35 A 3.5 A 5% +24.0 V 0.00 A 0.8 A 5% SDS120PT13B
120.0 W +5.0 V 1.50 A 15.00 A 5% +24.0 V 0.35 A 3.5 A 5% -12.0 V 0.00 A 0.8 A 5% SDS120PT14B
120.0 W +5.0 V 1.50 A 15.00 A 5% +24.0 V 0.35 A 3.5 A 5% +12.0 V 0.00 A 0.8 A 5% SDS120PT15B
120.0 W +5.0 V 1.50 A 15.00 A 5% +10.0 V 0.60 A 6.0 A 5% -10.0 V 0.00 A 1.0 A 5% SDS120PT16B
120.0 W +5.0 V 1.50 A 15.00 A 5% +10.0 V 0.60 A 6.0 A 5% +10.0 V 0.00 A 1.0 A 5% SDS120PT17B
Notes
1. Tol. (total regulation) includes line regulation and load regulation.
2. For optional PCB only version, delete suffix ‘B’ from model number.
Example SDS120PS03.
3. For non-standard voltages contact sales.
4. For optional low temperature -40 °C operation, add suffix ‘-L’ to model
number. Example: SDS120PS12B-L
5. For optional Power Fail Detect circuit, add suffix ‘-P’ to model number,
example: SDS120PS12B-P
1. Optional Power Fail Detect signal on ‘-P’ versions only. Standard models pin 13 is N/C.
2. I/P connector P1 mates with Molex housing 09-50-3051 & Molex 2878 series crimp terminal.
3. O/P P2 mates with Molex housing 09-50-3131 & Molex 2878 series crimp terminal.
4. For optional cover kit order part number SDS120 COVER, to receive unit with cover fitted
add suffix ‘-C’ to model number, e.g. SDS120PS12B-C (overall height is 1.73 (44.0)).
5. For mating connector kit order part number SDS120/SDS150 CON KIT.
6. For cable harness order part number SDS120S LOOM for single output models &
SDS120M LOOM for multi-output models.
7. Maximum mounting screw penetration: 0.14 (3.5)
8. All dimensions are in inches (mm).
9. Weight: 0.77-0.99 lbs (350-450 g) approx.
10. For PCB-only version, overall dimensions are max 5.00 x 3.00 x 1.44 (127.0 x 76.2 x 36.6).
PIN CONNECTIONS
Pin Single Dual Triple
1 V1 V2 V2
2 V1 V2 V2
3 V1 V1 V1
4 V1 V1 V1
5 V1 V1 V1
6 V1 V1 V1
7 Return Common Common
8 Return Common Common
9 Return Common Common
10 Return N/C V3
11 Return Common Common
12 Return Common Common
13 PFD(1) PFD(1) PFD(1)
Power Fail Detect (PFD)
is +5 V for normal operation.
Source current is 5 mA max.
PFD is <0.4 V for either
AC Fail (<90 VAC) or
DC Fail (<95% Vnom).
Sink current is 10 mA max.
+5 V
Pin 13
Internal
1.18 (30.0)
2.57
(65.3)
1.18 (30.0)
3.01+0.20 0.00 (76.4 +0.5 0.0)
3.20+0.20 0.01 (81.4 +0.5 -0.2)
4.49 (114.3)
0.10 (2.5)
5.00 (127.0)
4.49 (114.3)
4.00 (101.6) 0.25 (6.4)
2.70 (68.6) 0.55 (14.0)
M3XP0.5 (Mounting Holes) X 4
DCDC
OUTPUTOUTPUT
AC
INPUT
1
L
N
GG
P1
P2
0.25 (6.4)
1.54 (39.2)
0.32 (8.1)
3.20
(81.4)
M3xP0.5 (Mounting Holes) X 3
V Adj.
Notes
1.62 (41.2)
1.18 (30.0)
0.30 (7.7)
3.90
(99.0)
0.55
(14.0)
0.25
(6.4)
4.50
(114.3)
5.00
(127.0)
2.57 (65.3)
4.50 (114.3)
4.00 (101.6)
0.25 (6.4)
3.21 (81.5)
1.18 (30.0)
Pitch = 3.96 mm
0.54 (13.6)
0.67
(16.9)
M3* P0.5 (Mounting Holes) x 4
AC Input
M3* P0.5 (Mounting Holes) x 5
P2
P1
DC Output
13 1
G N L
Voltage
Adj.
ø4.0 (Mounting Holes) x 4
1.40 (35.6)
3.00 (76.2)
4.55 (115.6)
5.00 (127.0)
0.32 (7.9)
3.00 (76.2)
0.22 (5.5)
0.43 (10.9)
0.56 (14.2)
0.22 (5.7)
2.57 (65.3)
0.12 (3.0)
0.80 (20.3)
1.21 (30.7)
1.16 (29.6) 1.16 (29.6)
0.80 (20.3)1.57 (40.0)
M3 x P0.5 (Mounting Holes) x 4
Pitch = 3.96 mm
AC
Input
P2
P1
DC
Output
1
P2
P1
G
N
L
13
Voltage Adj.
SDS150
Mechanical Details
Models and Ratings
Output Power Output Voltage Output Current Total Regulation(1) Model Number(2,4,5,6)
Minimum Maximum
144 W 9 V 0 A 16.00 A 5% SDS150PS09B
150 W 12 V 0 A 12.50 A 5% SDS150PS12B
150 W 15 V 0 A 10.00 A 5% SDS150PS15B
150 W 18 V 0 A 8.33 A 4% SDS150PS18B
150 W 24 V 0 A 6.25 A 3% SDS150PS24B
150 W 30 V 0 A 5.00 A 2% SDS150PS30B
150 W 36 V 0 A 4.17 A 2% SDS150PS36B
150 W 48 V 0 A 3.13 A 2% SDS150PS48B
Notes
Open Frame
U Channel
1. Total regulation includes line regulation and load regulation.
2. For optional 2 pin Molex input, add suffix ‘-D’ to model number. Example SDS150PS12B-D.
3. For non-standard voltages contact sales.
4. For optional low temperature -40 °C operation, add suffix ‘-L’ to model number. Example: SDS150PS12B-L
5. For optional PCB only version, delete suffix ‘B’ from model number. Example SDS150PS48.
6. For optional Power Fail Detect signal (PFD), add suffix ‘-P’ to model number. Example: SDS150PS48B-P.
1. All dimensions in inches (mm), tolerance ±0.02 (±0.5).
2. Input connector P1 mates with Molex housing 09-50-3051 and
Molex 2478 series crimp terminal.
3. Output connector P2 mates with Molex housing 09-50-3131 and
Molex 2478 series crimp terminal.
4. Optional power fail detect signal on ‘-P’ versions only. Standard
models pin 13 is not connected.
5. For mating connector kit order part number
SDS120/SDS150 CON KIT.
6. For cable harness order part number SDS150 LOOM.
7. Maximum mounting screw penetration: 0.14 (3.5)
8. For optional cover kit order part number SDS150 COVER
9. Weight: U Channel - 1.27 lbs (580 g) approx.
Open Frame - 0.86 lbs (390 g) approx.
P2 - PIN CONNECTIONS
Pin Function Pin Function
1 V1 7 Return
2 V1 8 Return
3 V1 9 Return
4 V1 10 Return
5 V1 11 Return
6 V1 12 Return
13 PFD(4)
Power Fail Detect (PFD)
is +5 V for normal operation.
Source current is 5 mA max.
PFD is <0.4 V for either
AC Fail (<90 VAC) or
DC Fail (<95% Vnom).
Sink current is 10 mA max.
+5 V
Pin 13
Internal
ACDC
Notes
17-Dec-13
0.55
(14.0)
3.90
(99.1)
0.30
(7.7)
2.57 (65.3) 0.25
(6.4)
4.50 (114.3)
1.10
(28.0)
M3 x P0.5 (Mounting Holes) x 4
M3 x P0.5
(Mounting Holes) x 2
3.21 (81.6)
5.00
(127.0)
1.54 (39.2)
0.25
(6.4)
4.50
(114.3)
1.10 (28.0)
4.00
(101.6)
M3 x P0.5
(Mounting Holes) x 3
Pitch=3.96mm
For 12 V Version Only
Pitch=7.62 mm
DC
Output 4
0.85
(21.6)
2.18 (55.4)
LED
P2
18
L
P1
N
AC Input
25.6 +0.5
0.55
(14.0)
3.90
(99.1)
0.30
(7.7)
2.57 (65.3)
0.25
(6.4)
4.50
(114.3)
1.10
(28.0)
M3 x P0.5 (Mounting Holes) x 4 M3 x P0.5
(Mounting Holes) x 2
3.13 (79.6)
1.54 (39.2)
5.00
(127.0)
Pitch=3.96mm
AC Input
0.85
(21.6)
2.18 (55.4)
LED
P2
1 8
L
P1
N
Pitch=7.62 mm
DC
Output 4
25.6 +0.5
For 12 V Version Only
SDS180
Mechanical Details
Models and Ratings
Output Power Output Voltage Output Current Total Regulation(2) Model Number(3)
Minimum Maximum
170 W(1) 12 V 0 A 14.16 A 5% SDS180PS12B
180 W 24 V 0 A 7.50 A 3% SDS180PS24B
180 W 48 V 0 A 3.75 A 2% SDS180PS48B
Notes
Lbracket
U Channel
1. Output power is 170 W at highline input and 160 W at low line input, (90-132 VAC).
2. Total regulation includes line regulation and load regulation.
3. For optional L-bracket version, delete suffix ‘B’ from model number. Example SDS180PS48.
4. For non-standard voltages contact sales.
P2 - PIN CONNECTIONS
24/48 V versions
Pin Function Pin Function
1 Return 5 V1
2 Return 6 V1
3 Return 7 V1
4 Return 8 V1
PIN CONNECTIONS
12 V version
Pin Function Pin Function
1 Return 3 V1
2 Return 4 V1
1. All dimensions in inches (mm),
tolerance ±0.02 (±0.5).
2. Input connector P1 mates with Molex
housing 09-50-3031 and Molex 2478 series
crimp terminal.
3. Output connector P2 mates with Molex housing
09-50-3061 (or 09-50-3081) and Molex 2478
series crimp terminal for 24/48 V Versions. For
12 V Version, output
terminal is screw terminal.
4. For mating connector kit order part
number: SDS180 CON KIT.
5. For cable harness order part number
SDS180 LOOM.
6. Maximum mounting screw penetration: 0.14 (3.5)
7. Weight: U Channel - 1.14 lbs (520 g)
L-bracket - 1.06 lbs (480 g)
ACDC
Notes