EMD-FL-PF-400 Electronic monitoring relay for load monitoring in single and three-phase networks, based on the power factor cos INTERFACE Data sheet 102914_en_02 1 (c) PHOENIX CONTACT - 09/2009 Description Increasingly higher demands are being placed on safety and system availability - across all sectors. Processes are becoming more and more complex, not only in mechanical engineering and the chemical industry, but also in plant and automation technology. Demands on power engineering are also increasing constantly. Features - - - - - - Error-free and therefore cost-effective operation can only be achieved through continuous monitoring of important network - and system parameters. Electronic monitoring relays in the - EMD series are available for a wide range of monitoring tasks - to avoid the consequences of errors or to keep them within limits. Overload monitoring Underload monitoring Window function Adjustable threshold values Adjustable starting override Adjustable response delay Error memory Wide-range power supply unit Two PDTs The operating states are indicated using colored LEDs, errors that may occur can be sent to a control system via a floating contact or can shut down a part of the system. Some device versions are equipped with startup and response delays in order to briefly tolerate measured values outside the set monitoring range. WARNING: Risk of electric shock Never carry out work when voltage is present. Make sure you always use the the latest documentation. It can be downloaded at www.phoenixcontact.net/download. EMD-FL-PF-400 2 Ordering data Description Type Order No. Pcs. / Pkt. Electronic monitoring relay for load monitoring in single and three-phase networks, based on the power factor cos EMD-FL-PF-400 2885809 1 3 Technical data Input data Input name Measuring input Measured value AC sine (10 ... 100 Hz) Nominal input voltage UN (3 N ~ 415/240 V) Input voltage range 1(N) ~ 40 V AC ... 415 V AC 3 (N) ~ 40 V AC ... 415 V AC Maximum input voltage (3 N ~ 500/289 V) Input current range 0.5 A ... 10 A (Connection terminal blocks: L1i and L1k) Overload capacity 12 A permanent Input resistance of voltage input 1 M Input resistance current input 5 m Min. switching threshold cos 0.1 ... 0.99 Max. switching threshold cos 0.2 ... 1 Maximum temperature coefficient 0.1 %/K Setting range for response delay 0.1 s ... 40 s Setting range for starting delay 1 s ... 100 s Function Underload, overload, Window Basic accuracy 5 % (At cos = 0.8) Setting accuracy 5 % (At cos = 0.8) Repeat accuracy 1.8 % Recovery time 500 ms Output data Contact type 2 floating PDT contacts Nominal insulation voltage 250 V AC (in acc. with IEC 60664-1) Interrupting rating (ohmic load) max. 750 VA (3 A/250 V AC, module aligned, 5 mm spacing) 1250 VA (5 A/250 V AC, module not aligned, 5 mm spacing) Output fuse 5 A (fast-blow) Supply Range of supply voltages 24 V AC ... 240 V AC -15 % ... +10 % 24 V DC ... 240 V DC -20 % ... +25 % Frequency range 48 Hz ... 400 Hz Nominal power consumption 4.5 VA (1.5 W) General data Mains type 1 and 3-phase Service life mechanical Approx. 2 x 107 cycles Service life, electrical 2 x 105 cycles at ohmic load, 1000 VA Switching frequency max. 60 (per minute at 100 VA ohmic load) max. 6 (per minute at 1000 VA ohmic load) Operating mode 100% operating factor 102914_en_02 PHOENIX CONTACT 2 EMD-FL-PF-400 General data (Continued) Degree of protection IP40 (housing) / IP20 (connection terminal blocks) Pollution degree 2 (according to EN 50178) Surge voltage category III, basic insulation (as per EN 50178) Rated insulation voltage 300 V (According to EN 50178) Assembly on TS 35 profile rail acc. to EN 60715 Mounting position Any Width 22.5 mm Height 113 mm Length 90 mm Type of housing Polyamide PA, self-extinguishing Color green Weight 160 g Connection data Conductor cross section, solid 0.5 mm ... 2.5 mm Conductor cross section, stranded 0.25 mm ... 2.5 mm Stripping length 8 mm Type of connection Screw connection Tightening torque 1 Nm Ambient conditions Ambient temperature (operation) -25 C ... 55 C -25 C ... 40 C (corresponds to UL 508) Ambient temperature (storage/transport) -25 C ... 70 C Permissible humidity (operation) 15 % ... 85 % Climatic class 3K3 (in acc. with EN 60721) Conformance / approvals Conformity CE compliant UL, USA / Canada UL/C-UL listed UL 508 Conformance with EMC directive 2004/108/EC Immunity to interference according to EN 61000-6-2 Emitted interference according to EN 61000-6-4 Conformance with LV directive 2006/95/EC Electronic equipm. for electrical power installations according to 4 EN 50178 Block diagram 16 18 26 28 L1I L2 L3 15 L1K 25 A1 A2 U = 24...240 V AC/DC 102914_en_02 PHOENIX CONTACT 3 EMD-FL-PF-400 5 Safety notes WARNING: Risk of electric shock Never carry out work when voltage is present. Structure U/t 50 .6 RT 100 ( .8 s) .2 CO Sj .99 M 7 IN 3 REL 5 .9 CO Sj 1 .6 MA .4 .8 X .1 0,1 .9 10 DE LA 40 Y (s W W ) U O 25 16 Power factor monitor 4 15 L3 10 ST A .4 1 2 3 4 5 6 7 8 9 10 11 L UL FU NC OL TIO N 26 18 28 A2 6 7 "U/t" LED: Supply voltage and starting override "MAX" LED: Upper threshold value "MIN" LED: Lower threshold value "I=0" LED: Load switched off "REL" LED: Output relay "FUNCTION" rotary switch: Function selection "DELAY" potentiometer: Response delay "COSMIN" potentiometer: Lower threshold value "COSMAX" potentiometer: Upper threshold value "START" potentiometer: Starting override Universal snap-on foot for EN DIN rails 11 EMD-FL-PF-400 3 L1 K L2 5 1 MAX 2 A1 L1 MIN 1 I=O 6 7 8 9 10 Installation WARNING: Risk of electric shock Never carry out work when voltage is present. The module can be snapped onto all 35 mm DIN rails according to EN 60715. An integrated wide-range power supply unit enables the connection of a supply voltage in the range from 24 V AC/DC to 240 V AC/DC. 102914_en_02 PHOENIX CONTACT 4 EMD-FL-PF-400 8 Diagnostics The LEDs indicate the following error states: "U/t" LED (Green) - LED ON: Supply voltage present "MIN" and "MAX" LEDs (Red) - - - LED flashes: Set delay time is running LED ON: Delay time has elapsed Both LEDs flash alternately: Lower set threshold value is greater than upper threshold value "I=0" LED (Yellow) - LED ON: Load is switched off, no current flow between L1i and L1k "REL" LED (Yellow) - - LED ON: Output relay has picked up LED OFF: Output relay has dropped out 9 Connection examples L1 L1 L2 L3 L2 L3 N 24 V ~~ 0V Reset A1 L1K 15 A1 L1K 15 L3 L3 L2 15 L1i 25 15 L1i 25 16 18 26 28 16 18 26 28 25 26 28 25 26 28 16 18 A2 16 18 A2 3 ~ 400 V measuring range, without error memory, 24 V AC supply voltage, IN < 10 A 102914_en_02 L2 3 ~ 400 V measuring range, with error memory, 230 V AC supply voltage, IN < 10 A PHOENIX CONTACT 5 EMD-FL-PF-400 L1 L1 N L2 L3 N Reset A1 L1K 15 A1 L1K 15 L3 L3 L2 15 L1i 25 15 L1i 25 16 18 26 28 16 18 26 28 25 26 28 25 26 28 16 18 A2 16 18 A2 1 ~ 230 V measuring range, without error memory, 230 V AC supply voltage, IN < 10 A 10 L2 3 ~ 400 V measuring range, with error memory, 230 V AC supply voltage, IN > 10 A Function If an error is present when the monitoring module is activated, output relay "R" remains dropped out and the LED for the corresponding threshold value lights up. For all functions the "MIN" and "MAX" LEDs flash alternately if the minimum value selected is greater than the maximum value. The "FUNCTION" rotary switch is used to set the desired function: - O = Overload monitoring (OVER) - OL = Overload monitoring with error memory (OVER + LATCH) - U = Underload monitoring (UNDER) - UL = Underload monitoring with error memory (UNDER + LATCH) - W = Monitoring of the area between thresholds MIN and MAX (window function) (WIN) - WL = Monitoring of the area between thresholds MIN and MAX (window function) with error memory (WIN + LATCH) 102914_en_02 PHOENIX CONTACT 6 EMD-FL-PF-400 Overload Monitoring (OVER and OVER + LATCH) U LED U/t LED MAX LED MIN OL OVER+LATCH LED REL,R Max Min START DELAY