Precision Low Profile Load Cell
Model 41
DESCRIPTION
Model 41 is a low profile “pancake” type load cells. These
bonded foil, strain gage load cells are engineered to measure
loads from 5 lb to 500,000 lb. The tension/ compression
Model 41 is designed with the threaded hole running completely
through the center of the cell. Model 41 utilizes two stabilizing
diaphragms, which are welded to the sensing member to
reduce off-center and side-loading effects. It provides high
performance in non-linearity, hysteresis, and repeatability speci-
fications for such applications as tube mills, extruding processes
and weighing. Each unit has a welded construction and can be
hermetically sealed for added durability. Model 41 load cells are
available with optional 0 Vdc to 5 Vdc or 4 mA to 20 mA output.
FEATURES
• 0.1%accuracy
• 5lbto500000lb
• mV/Voutput(standard);4mAto20mAand0Vdcto5Vdc
(optional)outputs
• Doublediaphragmdesign
• Intrinsicallysafeavailable(2Noptiononly)16
• CEapproved17
Approved Approved
2Honeywell•SensingandControl
Model 41
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Load ranges18 5 lb to 500000 lb
Non-linearity,5lbto25lb ±0.2%fullscale
Non-linearity,
50 lb to 500000 lb ±0.1%fullscale
Hysteresis, 5 lb to 25 lb ±0.1%fullscale
Hysteresis,
50 lb to 500000 lb ±0.08%fullscale
Non-repeatability,5to25lb ±0.1%fullscale
Non-repeatability,
50 lb to 500000 lb ±0.03%fullscale
Output(tolerance),
5 lb to 25 lb 2mV/V±0.5%fullscale
Output(tolerance),
50 lb to 500000 lb 3mV/V±0.5%fullscale
Operation Compression/tension13
Resolution Infinite
Standardcalibration 5-pointcalibration:0%,50%and100
%offullscaleintensiononly
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54°Cto121°C[-65°Fto250°F]
Temperature, compensated 15°Cto71°C[60°Fto160°F]
Temperature effect, zero 0.002%fullscale/°F
Temperature effect, span 0.002%fullscale/°F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Straingagetype Bonded foil
Excitation(calibration) 10 Vdc
Insulation resistance 5000 mOhm @ 50 Vdc
Bridge resistance
(tolerance)
350ohm(nominal)
Zerobalance(tolerance) ±1%fullscale
Shuntcalibrationdata Included
Electricaltermination(std)
5 lb to 5000 lb
PTIH-10-6P
Electricaltermination(std)
7500 lb to 500000 lb
MS3102E-14S-6P
Mating connector
5lbto5000lb(notincl.)
PT06A-10-6Sorequiv.(AA111)
Mating connector
7500to500000lb(notincl.)
MS3106A-14S-6S(AA121)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load 150%FS1
Weight Seetable
Material
Less than 200,000 lb
17-4PH stainless steel
Material greater than or
equalto300000lb
Carbonsteel
Deection Seetable
Naturalfrequency Seetable
RANGE CODES
Range
Code
Available ranges Range
Code
Available ranges
AT 5 lb DV 10000 lb
AV 10 lb EJ 15000 lb
BL 25 lb EL 20000 lb
BN 50 lb EN 30000 lb
BR 100 lb EP 50000 lb
CN 250 lb ER 75000 lb
CR 500 lb ET 100000 lb
CV 1000 lb FJ 150000 lb
DL 2000 lb FL 200000 lb
DN 3000 lb FN 300000 lb
DP 4000 lb FP 400000 lb
DR 5000 lb FR 500000 lb
DT 7500 lb
WIRING CODES
Connector Unamplied (Std.)
A(+)excitation
B(+)excitation
C(-)excitation
D(-)excitation
E(-)output
F(+)output
DEFLECTIONS AND RINGING FREQUENCIES
Capacity (lb) Deection @
full scale (in)
Natural ringing
frequency (Hz)
Weight
(lb)
5 to 25 0.001 2000 0.8
50 to 1000 0.002 4600 1.5
2000 to 5000 0.002 10000 2.0
7500 to 15000 0.003 6000 8.8
20000 to 50000 0.004 8000 11.0
75000 to 100000 0.006 5500 30.9
150000 to 200000 0.010 4500 46.3
300000 to 500000 0.010 4100 130.1
Honeywell•SensingandControl3
Precision Low Profile Load Cell
iNTERNAL AMPLIFIERS
Amplier
specications
Voltage out-
put: Option 2b
Voltage out-
put: Option 2c
Voltage out-
put: Option 2t
Current three-
wire: Option 2j
Current two-
wire: Option
2k
Intrinsically
safe amp: Op-
tion 2n (2N)***
Output signal ±5 V 0-5 V or ±5 V @
45 mA
0-10 V or ±10 V
@ 45 mA
4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA
Input power (voltage) ±15 Vdc or 26-32
Vdc
11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to
32 Vdc
9 Vdc to
28 Vdc
Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA
Freq. response 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz
Power supply rejection 60 db 60 db 60 db 60 db 60 db 60 db
Operating temperature -20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F
Reverse volt. protection Yes Yes Yes Yes Yes Yes
Short circuit protection Momentary Momentary Momentary Yes Yes Yes
Wiring code: connector A(+)Supply
B Output common
CSupplyreturn
D(+)Output
EShuntCal1
FShuntCal2
A(+)Supply
B Output common**
CSupplyreturn**
D(+)Output
EShuntCal1
FShuntCal2
A(+)Supply
B Output common**
CSupplyreturn**
D(+)Output
EShuntCal1
FShuntCal2
A(+)Supply
B Output common**
CSupplyreturn**
D(+)Output
EShuntCal1
FShuntCal2
A(+)Supply
BNoconnection
CNoconnection
D(+)Output
ECaseground
FNoconnection
A(+)Supply
BNoconnection
CNoconnection
D(+)Output
ECaseground
FNoconnection
Wiring code: cable R(+)Supply
Bl Output common
GSupplyreturn
W(+)Output
BShuntCal1
BrShuntCal2
R(+)Supply
Bl Output com*
GSupplyreturn*
W(+)Output
BShuntCal1
BrShuntCal2
R(+)Supply
Bl Output com*
GSupplyreturn*
W(+)Output
BShuntCal1
BrShuntCal2
R(+)Supply
Bl Output com*
GSupplyreturn*
W(+)Output
BShuntCal1
BrShuntCal2
R(+)Supply
Bl(+)Output
WCaseground
R(+)Supply
Bl(+)Output
WCaseground
* Black and green wires are internally connected.
**PinsBandCareinternallyconnected.
***SeeourWebsite(http://measurementsensors.honeywell.com)forthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.
ALLOWABLE MAXIMUM LOADS
Capacity (lb) Side load
(lb)
Bending
(lb-in)
Torque
(lb-ft)
5 to 25 50% 40% 25%
50 to 1000 45% 35% 25%
2000 to 5000 30% 25% 25%
7500 to 30000 20% 20% 15%
50000 to 100000 20% 20% 15%
150000 to 200000 20% 20% 15%
300000 20% 20% 10%
400000 20% 20% 10%
500000 20% 20% 10%
4Honeywell•SensingandControl
Model 41
OPTION CODES
Many range/option combinations are available in our quick-ship and fast-track manufacture programs.
Please see http://measurementsensors.honeywell.com for updated listings.
Load ranges 5, 10, 25, 50, 100, 250, 500, 1000, 2000, 5000, 3000, 4000, 7500, 10000, 15000, 20000, 30000, 50000, 75000, 100000, 150000,
200000, 300000, 400000, 500000 lb
Temperature
compensation
1a.60°Fto160°F
1b.30°Fto130°F
1c.0°Fto185°F
1d.-20°Fto130°F
1e.-20°Fto200°F
1f.70°Fto250°F
1g.70°Fto325°F14
1h.70°Fto400°F14
1i.-65°Fto250°F14
1j.0°Cto50°C
1k.-20°Cto85°C
1m.-25°Cto110°C
Internal
ampliers 10
2b. 4 wire, ±5 Vdc
2c. 0-5 Vdc output
2j.4-20mA(three-wire)
output
2k.4mAto20mA(two-
wire)20
2n(2N)4mAto20mA(wire)
intrinsically safe20
2t. 0 Vdc to 10 Vdc
2u. Unamplified, mV/V output
Internal ampli-
er enhance-
ments
3a. Input/output isolation19
3d. Remote buffered shunt calibratrion8
Overload
stops
4a. Overload stops
Electrical
termination
6a. Bendix PTIH-10-6P 6-pin
(rangesto5000lb)
6b.MS3102E-14S-6P(rang-
es7500lbandup)9
6e.Integralcable:Teon
6f.Integralcable:PVC
6g.Integralcable:Neo-
prene9
6h.Integralcable:Silicone
6i. Integral underwater
cable9
6j. 1/2-14 conduit fitting with
5ftof4conductorPVC
cable
6q.Moldedintegralcablepoly-
urethane9
6v. Phoenix connector on end of
cable
Shunt calibra-
tion
8a. Precision internal resistor14
Special cali-
bration
9a.10point(5up/5down)20%increments@68°F
9b.20point(10up/10down)10%increments@68°F
9c.ASTME-74calibration
Bridge resist-
ance
12b.5000ohm(foil)
Zero and span
adjustment
14a.Noaccesstopots
14b. Top access to pots
Electrical con-
nector orienta-
tion
15a. Horizontal electrical exit port orientation
15b. Vertical electrical exit port orientation
15c. Radial electrical exit port orientation
15d.Connectoronendofcable
Special cali-
bration
30a. Compression only calibration, positive in compression
30b. Tension and compression calibration, positive in tension
30c. Compression only calibration, negative in compression
30d. Tension and compression calibration, positive in compression
Bridge type 31a.Dualbridge
Shock and
vibration
44a.Shockandvibrationresistance
Interfaces 53e.Signaturecalibration14
53t.TEDSIEEE1451.4module15
Honeywell•SensingandControl5
Precision Low Profile Load Cell
MOUNTING DIMENSIONS
Ranges
lb
D mm
[in]
H mm
[in]
H***
mm
[in]
F# ØG
mm [in]
B.C.
ØK mm
[in]
thru
T A mm
[in]
A* mm
[in]
B mm
[in]
B* mm
[in]
C mm
[in]
5, 10, 25 63,5
[2.50]
20,32
[0.80]
44,45
[1.75]
6 50,8
[2.000]
4,83
[0.19]
1/4-28
UNF
20,83
[0.82]
63,5
[2.5]
19,05
[0.75]
22,86
[0.9]
31,75
[1.25]
50, 100,
250, 500,
1000
76,2
[3.00]
25,4
[1.00]
44,45
[1.75]
6 57,15
[2.250]
7,11
[0.28]
3/8-24
UNF
20,83
[0.82]
63,5
[2.5]
19,05
[0.75]
22,86
[0.9]
31,75
[1.25]
2000,
3000,
4000,
5000
88,9
[3.50]
25,4
[1.00]
44,45
[1.75]
6 66,68
[2.625]
8,64
[0.34]
1/2-20
UNF
20,83
[0.82]
63,5
[2.5]
19,05
[0.75]
22,86
[0.9]
31,75
[1.25]
7500,
10000,
15000
139,7
[5.50]
45,7
[1.80]
45,7
[1.80]
8 114,3
[4.500]
10,16
[0.40]
1-14
UNS
31,75
[1.25]
58,42
[2.3]
38,1
[1.50]
38,1
[1.5]
50,8
[2.00}
20000,
30000,
50000
152,4
[6.00]
45,7
[1.80]
45,7
[1.80]
8 123,83
[4.875]
13,46
[0.53]
1 1/2-12
UNF
31,75
[1.25]
58,42
[2.3]
38,1
[1.50]
38,1
[1.5]
50,8
[2.00}
75000,
100000
228,6
[9.00]
63,5
[2.50]
63,5
[2.50]
12 196,85
[7.750]
16,76
[0.66]
2-12UN 31,75
[1.25]
58,42
[2.3]
38,1
[1.50]
38,1
[1.5]
50,8
[2.00}
150000,
200000
279,4
[11.00]
63,5
[2.50]
63,5
[2.50]
12 241,3
[9.500]
19,81
[0.78]
2 1/2-12
UN
31,75
[1.25]
58,42
[2.3]
38,1
[1.50]
38,1
[1.5]
50,8
[2.00}
300000,
400000,
500000
355,6
[14.00]
107,95
[4.25]
107,95
[4.25]
12 298,45
[11.750]
26,16
[1.03]
3 1/2-8
UN
31,75
[1.25]
58,42
[2.3]
38,1
[1.50]
38,1
[1.5]
**
*Lengthofloadcellwithampliedoption(seeoptioncodes)
**Cdimensionvariesonhighranges.Consultfactory
***Hdimensionwith2n(2N)amplier
TYPICAL SYSTEM DIAGRAM
Mounting options
1. Pull plate
2. Load button
1
2
Model 41
Customer supplied
Chart recorder
Alarm panel
Data acquisition
Computer
PLC
Display units
SC500
SC2000
SC2001
SC3004
GM (unamplified only)
GM-A (amplified only)
NK (unamplified only)
HH (unamplified only)
In-line amplifiers (used with unamplified units only)
Amplifier Output
Universal in-line amplifiers
UV ±5 Vdc
UV-10 ±10 Vdc
UBP 0 ±5 Vdc
U3W 4 mA to 20 mA (3-wire)
U2W 4 mA to 20 mA (2-wire)
DIN rail mount in-line amplifiers
DV-05 0 ±5 Vdc (3-wire)
DA-05 4 mA to 20 mA (3-wire)
DV-10 0 ±10 Vdc (3-wire)
Mating connectors & cables
PT06A-10-6S, std.
PT06E-10-6S
MS3106A-14S-6S
008609-3-EN IL50 GLO
June 2013
Copyright © 2013 Honeywell International Inc. All rights reserved.
Model 41 Precision Low Profile Load Cell
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
www.honeywell.com/sensing
NOTES
1. Allowable maximum loads - maximum load to be applied without
damage.2
2. Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical
applications(overheadloading,etc.)shouldalwaysbedesignedwith
safety redundant load paths.
3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal pro-
vides50%(unampliedunits),75%(4mAto20mA3-wireunits)or
80%(voltageampliedunits)offullscaleoutputforquickcalibration.
Shuntcalibrationcomesstandardwithinternalamplieroption2b,2c,
2t and 2j.
4.O=Orange;Y=Yellow;B=Blue;Bl=Black;R=Red;Br=Brown;
W=White;G=Green.Colorspecifyingcableandnumberorletter
specifying connector.
5.Nomatingconnectornecessaryforcableoption.
6. Adding any internal amplifiers on 5 lb to 25 lb ranges will increase
delivery time.
7.Option2n(2N)on5to5000lb.rangeswilltypicallytake12weeksfor
delivery.
8.Option3disnotavailablewithoption2n(2N)or2k.
9.Notavailablewithoption1c,1e,1f,1g,1hor1i.
10.Consultfactory.
11.Availability varies with range, consult factory.
12.Optiononlypertinentwhenoption2n(2N)selected.
13.Standardcalibrationfortension/compressionloadcellsisintension
only.
14.Notavailablewithampliedoutput.
15.ConsultfactoryforTEDSavailabilitywithampliedmodels.
16.Rangedependent;consultfactory.Terminationdependent;consult
factory.
17.Internalampandterminationdependent;consultfactory.
18.ThisunitcalibratedtoImperial(non-Metric)units.
Find out more
Honeywell serves its customers
through a worldwide network of
sales offices, representatives
anddistributors.Forapplication
assistance, current specifica-
tions, pricing or name of the
nearestAuthorizedDistributor,
contact your local sales office.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
http://measurementsensors.
honeywell.com, ore-mailinqui-
ries to info.tm@honeywell.com
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
tootherwisebyHoneywellinwriting;pleaserefertoyour
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and tness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specicationsmaychangewithoutnotice.Theinformationwe
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
WARNING
PERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•Theinformationpresentedinthisdatasheetisfor
referenceonly.DONOTUSEthisdocumentasproduct
installation information.
•Completeinstallation,operationandmaintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Honeywell:
060-0574-03 060-0572-05 060-0571-07 060-0571-06