Wiring Systems
®
17
Hubbell Healthcare Application Guide
For complete listing of Hubbell Wiring and Premise products see our full line catalogs.www.hubbell-premise.com
Restrooms
With a restroom in every patient room and throughout staff and public areas, hospitals and healthcare
facilities can contain hundreds of restrooms. Required by code, receptacles in any wet area must be
a ground fault circuit interrupter. Many healthcare restrooms require hospital grade GFCIs while others
can use commercial-grade GFCIs.
GFCI Safety Code
The combination of GFCI protection
and tamper-resistant safety
provides an ideal “one-stop”
Hubbell solution. Hubbell tamper-
resistant GFCI devices also include
a weather resistant rating per NEC®
406.9, providing UV and corrosion
resistance for harsh, damp
applications.
While GFCIs protect people
in bathrooms, scrub rooms,
kitchenettes and other potentially
wet locations throughout healthcare
facilities, they should not be used
in critical care patient areas or for
electrical life support equipment
in ICUs and operating rooms
because of the possibility of power
interruption.
Wireless Sensors
There are many retrot applications
where running the extra wiring for
traditional occupancy sensors is
difcult or impossible. This is where
Hubbell’s WL-Series Wireless
Controls shine by eliminating sensor
wiring. Deploy Hubbell’s popular
wired controls where you can and
then utilize WL-Series Controls in
the areas that have hard ceilings,
asbestos, or poor switch locations.
NEC® is a registered trademark of the National
Fire Protection Association (NFPA).
Ceiling Sensor Wall Switch
Description Color Catalog Number Description Color Catalog Number
Ceiling sensor,
2000 sq. ft.
White ATU2000C Wall switch without button,
400 sq. ft.
Ivory
White
AU2000I1N
AU2000W1N
Control unit; 120/277V AC,
50/60 Hz, for use with
ceiling sensors
Black CU300A
Ultrasonic Adaptive Technology
Occupancy Sensors
• Provides superior minor motion sensitivity, even in stalls
• Automatically adjusts sensor settings for optimum performance
• Use optional isolated relay to integrate with building automation
and HVAC systems
Rating NEMA Color Standard Assembled in USA Isolated Ground SNAPConnect® GFCI*
15A 125V
Ivory
Red
White
GFTWRST82I
GFTWRST82R
GFTWRST82W
GFTWRST82IU
GFTWRST82RU
GFTWRST82WU
GFTWRST82IIG
GFTWRST82RIG
GFTWRST82WIG
GFTWRST82SNAPI
GFTWRST82SNAPR
GFTWRST82SNAPW
20A 125V
Ivory
Red
White
GFTWRST83I
GFTWRST83R
GFTWRST83W
GFTWRST83IU
GFTWRST83RU
GFTWRST83WU
GFTWRST83IIG
GFTWRST83RIG
GFTWRST83WIG
GFTWRST83SNAPI
GFTWRST83SNAPR
GFTWRST83SNAPW
Description Wire Type General Use Assembled in USA
SNAPConnect® Right Angle Pigtailed Connector - 600V
Clear right angle terminal with 6 inch leads #12 AWG
THHN/THWN-2; polycarbonate housing material
Solid
Stranded
SNAP1RA
SNAP2RA
SNAP1RNA
SNAP2RNA
* SNAPConnect GFCI must use a SNAPConnect Pigtailed connector.
Hospital Grade GFCI Tamper-Resistant
Weather Resistant Receptacles
• Ground fault indicator ashes red when device has
lost capability to provide protection
• Test button functionally tests both electronic
components and trip mechanism
• No power at device face if reverse wired
Description Color Catalog Number
Ceiling mount 360° - 324-676 ft2White WLP450C
Wall mount 180° - 3000 ft2White WLP3000W
Corner mount 90° - 2500 ft2White WLP2500W
Description Color Catalog Number
8A Lighting, 3A Fan (1/10 HP
motor, 120V only), Spec. Grade
Electronic Switch 120–277V,
No Neutral Wire Required
Ivory
White
WLS1278I
WLS1278W
Description Color Catalog Number
Wireless load control unit
with isolated relay
White WLC316R
Compatible Transmitters: WLP series and WLDH sensors or any
Lutron Clear Connect Enabled Sensor.
Wireless Sensors
• Eliminates need to run extra wires
• Supports highly recongured spaces
• Helps manage energy consumption
Clear Connect™ is a registered trademark of Lutron Electronics Co., Inc.