motion sensor EKMBWLseries Current consumption 1/2/6A Digital output Low current consumption for battery-driven applications A special differential input circuit designEKMB 6A type only for applications where a high noise resistance is requiredup to GHz range. Standard detection type Long distance detection type Recommended applications IoT, occupancy sensor module for smart home, battery-driven applications, wireless devices Lensless type available 6A type: EKMB1300100K 1A type: EKMB1100100 2A type: EKMB1200100 Wall installation type Specifications Detection performance Model no. Standard detection type EKMB1101111 Current consumption EKMB1101112 Pearl white White 6A EKMB1103111 Digital 102 92 92 12m1st step lens 6m2nd step lens 3m3rd step lens Please refer to page 8 for details. 40 105 68 Black Pearl white EKMB1104111 White 1A Black EKMB1104113 Pearl white EKMB1204111 White 2A Black EKMB1204113 Pearl white EKMB1304111K White 6A EKMB1304113K Black Pearl white EKMB1 PaPIRs motion sensor Current consumption in standby mode 1: 1A / 2: 2A / 3: 6A DetectionLens 00: Lensless / 01: 5m distance standard / 03: 12m long distance / 04: Wall installation type 5 Black 6A EKMB1303113K information 12m White 2A White Ordering 64 Pearl white Pearl white EKMB1304112K 82 Black EKMB1303111K EKMB1204112 94 White EKMB1203113 EKMB1104112 5m Black 1A EKMB1203111 EKMB1303112K Detection zones Pearl white EKMB1103113 Wall installation type Black EKMB1301111K EKMB1203112 Vertical White EKMB1201113 EKMB1103112 Horizontal Black 2A EKMB1301113K Long distance detection type Detection area Detection distance Pearl white EKMB1201111 EKMB1301112K Output type White 1A EKMB1101113 EKMB1201112 Lens color 1 Others K: 6A / Blank: Other than 6A Lens color 0: Lensless / 1: White / 2: Black / 3: Pearl white Lens 0: Lensless / 1with lens Characteristics Maximum rated values Items Value Power supply voltage -0.3 to 4.5V Ambient temperature -20 to +60 (No frost, no condensation) Storage temperature -20 to +70 Electrical Characteristics Items Symbol Operating voltage Max Min 1A type 2A type 6A type Conditions 4.0V Vdd 2.3V Current consumption (in standby mode) Note 1) Ave Iw Output current (during detection period) Note 2) Max Iout 100A Ambient temperature: 25 VoutVdd-0.5 Output voltage (during detection period) Min Vout Vdd0.5V Ambient temperature: 25 Open at no detection Circuit stability time (when voltage is applied) Ave Max 1A Twu 2A Ambient temperature: 25 Iout=0 Vdd: 3V 6A 25 sec 210 sec 10 sec, Note 3) Ambient temperature: 25 Iout=0 Vdd: 3V Note 1) The total current consumption is equal to the current consumption in standby mode (Iw) plus the output current during detection (Iout). For the 1A type please note that the average current consumption is 1A in sleep mode and 1.9A in standby mode. Please also refer to the timing chart. Note 2) Please select an output resistors (pull-down concept) in accordance with Vout so that the output current is lower than or equal to 100A. If the output current is more than 100A, this may cause false alarms. Note 3) The sensor temperature has to be constant for the time specified. Timing chart 2A 6A type 1A type ON ON Power supply Power supply OFF OFF Present Present Detecting target Detecting target Absent Absent ON Output voltage Mode OFF 1Sleep 2Standby 3Mask Unstable 1 2 3 1 2 3 1 2 3 Twu ON Explanation of the timing Twu: Circuit stability time: about 25 sec (typ.) for 2A type, max. 10 sec for 6A type. While the circuitry is stabilizing after the power is turned on, the sensor output is not fixed in the ON or OFF state. This is true regardless of whether or not the sensor has detected anything. Output voltage OFF t1Twu t2 t3 t2 t3 t2 2 1 Explanation of modes 1Sleep mode: When the output is OFF. The electrical current consumption is around 1A. 2) Standby mode: After the sensor's output has reached ON status, the sensor switches to standby mode. The electrical current consumption gets close to 1.9A . When the sensor's output returns to its OFF value after the "hold time" has expired, the sensor switches again to sleep mode. 3) Mask mode: Time during which the output is forced to OFF status after the end of the standby mode. (No detection is possible during this period.) Explanation of the timing t1 (Twu): Circuit stability time: about 25 sec (typ.) While the circuitry is stabilizing after the power is turned on, the sensor output is not fixed in the ON or OFF state. This is true regardless of whether or not the sensor has detected anything. t2: Standby hold time: about 2.6 sec (typ.) after the last detection of a signal. () t3: Mask time: about 1.3 sec (typ.) During this stage, even if the sensor detects something, the output will not switch to ON. 6 Lenses for the EKMB/EKMC series Dimension Detection zone mm Detection characteristics Y Standard detection type 5m Y Detection distance Field of view Detection zone Detection condition 2.5m 9.5 CAD data (48.5 41 A A 13 0.45 0.05 5.6m X 14.4 4.6 11 VDD GND 454 6.6m X-Y Cross Section (48.5 41 P.C.D.5. 08 0.2 OUT SIDE VIEW 4 45 Max. 5m x82 94 64 beams The temperature difference between the target and the surroundings must be higher than 4. Movement speed: 1.0m/s 47 (53 Target concept: Human 47 (53 body with an approx. size of 700x250mm X A-A Cross sectional Target moving direction: Crossing the detection beam. TOP VIEW 5m Y 12m Long distance detection type 2.5m (49.5 46.3 Y CAD data Detection distance Field of view Detection zone Detection condition 5m 22 20.7 11.6m X 20.2 A A 7.3 0.45 0.05 P.C 4.6 11 .D. 5.0 8 0 13.8m X-Y Cross Section VDD .2 2.5 GND 46.3 (49.5 5 OUT 45 4 SIDE VIEW 4 45 Max. 12m x92 102 92 beams The temperature difference between the target and the surroundings must be higher than 4. Movement speed: 1.0m/s 51.3 (54 51.3 (54 Target concept: Human body with an approx. size of 700x250mm X Target moving direction: Crossing the detection beam. TOP VIEW 12m A-A Cross sectional Wall installation type 5m Detection distance Y 22 20.7 CAD data 5.7m 2nd step 18 25 A 20.2 A 0.45 0.05 4.6 X-Y Cross Section SIDE VIEW 11 .D. 5.0 8 0 3rd step 14.9m 44 5m 49 12m 7.3 P.C 1st step 4 VDD .2 2.5 GND 52.5 56 5 OUT 45 4 X Field of view Detection zone Detection condition 52.5 56 5m 4 45 TOP VIEW 12m 1st step lens Max. 12m 2nd step lens Max. 6m 3rd step lens Max. 3m x105 40 68 beams The temperature difference between the target and the surroundings must be higher than 4. Movement speed: 1.0m/s Target concept: Human body with an approx. size of 700x250mm Target moving direction: Crossing the detection beam. A-A Cross sectional PIR element Lensless type 3.0 0.6mm 3.0 Average: 5.6W/c Detection sensitivity 0.4mm 9.1 8.3 55 0.6mm Maximum: 7.6W/c ELEMENT 9.3 8.4 Detection sensitivity is measured by following system 0.6mm 0.6mm 0.4mm Test setup 0.45 0.05 5.5 P.C .D. 5.08 0 Black body 250 Aperture 3.2mm Masking plate PaPIRs VDD DC5V .2 GND OUT 45 4 340mm Chopper 1Hz 4 45 CAD data CAD data can be downloaded from the PaPIRs WEB site. Panasonic PaPIRs Recorder Search Please refer to the formal specification for the dimension, and the tolerance Please note that the horizontal and vertical field of view depends on the position of the metal tab on which the lens is mounted. 8 SATURN LENS - NEW Dual zone 90 90 44 44 Standard motion detection area 2.2m 1.8m Slight motion detection area o4.4m Standard and slight-motion detection type Choose by the current consumption in standby mode 1A (1A type: in sleep mode) 2A Choose by output 6A Digital 170A Digital Analog White EKMB1193111 EKMB1293111 EKMB1393111K EKMC1693111 By request Black EKMB1193112 EKMB1293112 EKMB1393112K EKMC1693112 By request Pearl white EKMB1193113 EKMB1293113 EKMB1393113K EKMC1693113 By request Choose by lens color Saturn lens Dimension Detection zone (mm) Standard and slightmotion detection type Detection characteristics Detection distance Vertical Slight motion detection area CAD data by request 14.9 14.1 17.2 7.9 A (0.018 dia) 4.6 0.45 0.05 11 P.C.D 5.08 0.2 Max. 2.2m* Slight motion Standard motion Slight motion Standard motion 2 4.5 GND OUT 45 4 44 x 44 90 x 90 36 48 * The temperature difference between the target and the surroundings must be higher than 4C. * Movement speed: 0.5ms * Target concept: Human head with an approx. size of 200x200mm * Target moving direction: Crossing the detection beam, 1 zone Standard motion * The temperature VDD 4 Field of view Detection zone Detection Slight motion condition A 45 Standard motion detection area Horizontal difference between the target and the surroundings must be higher than 4C. * Movement speed: 1.0ms * Target concept: Human body with an approx. size of 400x200mm * Target moving direction: Crossing the detection beam, 2 zones * Under specified detection conditions Please refer to "Caution for use" (page 13) and "Basic principles"(page 13, point 5), for more details Please contact your local sales representative for detailed specifications.