U7100
Pressure Transducer
U7100 www.meas-spec.com December 2012
1/6
Performance standard for on and off
highway engine & vehicle OEMs
Rugged for heavy equipment and
outdoor use such as HVAC refrigeration
systems
Designed specifically for high volume
applications
Stainless Steel wetted surfaces
Low pressure ranges
Gage, absolute, sealed gage
DESCRIPTION
The U7100 pressure transducer from the UltraStable™ line of MEAS sets a new price performance standard for
demanding engine and vehicle, and industrial applications. This transducer is suitable for measurement of liquid
or gas pressure, even for difficult media such as contaminated water, steam and corrosive fluids. The
transducer pressure cavity is constructed of 316L stainless steel and there are no internal O-rings or organics
exposed to the pressure media. Having excellent durability, it is available with a variety of leak-proof, all metal
pressure connections. The U7100 is an automotive grade pressure transducer with hermetic pressure ports and
an integral electrical connector with standard pressure ranges from 0 to 15, up to 150 psi (10 Bar).
This pressure sensor exceeds the latest industrial CE requirements and includes automotive electronics
requirements such as surge protection, and is overvoltage protected to 16 Vdc in both positive and reverse
polarity.
FEATURES APPLICATIONS
Hermetic Pressure Ports On and Off Highway Engines and Vehicles
Integral Electrical Connector HVAC Refrigeration Controls
Survives High Vibration Compressors
±0.25% Accuracy Hydraulics
Water Resistant 1M Immersion Energy and Water Management
STANDARD RANGES
Range psiG, psiA, psiS Range BarG, BarA, BarS
0 to 015 0 to 001
0 to 030 0 to 002
0 to 050 0 to 3.5
0 to 100 0 to 007
0 to 150 0 to 010
U7100
Pressure Transducer
U7100 www.meas-spec.com December 2012
2/6
PERFORMANCE SPECIFICATIONS
Supply Voltage: 5V
Ambient Temperature: 25°C (unless otherwise specified)
PARAMETERS MIN TYP MAX UNITS NOTES
Supply Voltage 4.75 5.00 5.25 V
Supply Current 4 10 mA
Ratiometric Output 0.5 4.5 V 1, 5
Accuracy (combined linearity, hysteresis &
repeatability) -0.25 0.25 %Span 2
Total Error Band -1.0 1.0 %Span 3
Compensated Temperature -20 +85 °C
Operating Temperature -40 +125 °C
Storage Temperature -50 +125 °C
Insulation Resistance (500Vdc) 100 MΩ 4
Reverse Voltage 16 V
Overvoltage Protection 16 V
Short Circuit Protected Continuous
Output Noise @ 1kHZ 10 mV
Response Time (10% to 90%) 1.0 ms
Long Term Stability -0.25 0.25 %Span/Year
Notes
1. Ratiometric to supply voltage.
2. Best fit straight line.
3. TEB includes all accuracy errors, thermal errors, span and zero tolerances over the compensated temperature range. See Chart A.
4. Between sensor body to any pins of connector.
5. This product can be configured for custom OEM requirements. Contact factory for different transfer functions and output clippings.
See chart B.
ENVIRONMENTAL SPECIFICATIONS
Supply Voltage: 5V
Ambient Temperature: 25°C (unless otherwise specified)
PARAMETERS MIN TYP MAX UNITS NOTES
Humidity (@40°C) 93 %RH
Pressure Overload 2X Rated 6
Pressure Burst 3X Rated 7
Pressure Cycle 10M Cycles
Mechanical Vibration 20g, 10 ~ 2000Hz
MIL-STD-810C, Method 514.2, Curve L
Mechanical Shock Half-Sine, Peak: 50g, 11ms
MIL-STD-202, Method 213B, Condition A
Package Protection IP67 (IEC60529)
Notes
6. The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
7. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer. See Chart B.
U7100
Pressure Transducer
U7100 www.meas-spec.com December 2012
3/6
Agency Approvals
Performance Criteria Class A: Output Change < ±1.5% FSO
IEC61000-4-2 Electrostatic Discharge Immunity: 8kV Contact / 15kV Air; Discharge Rate > 10s
IEC61000-4-3 EM Field Immunity: 100V/m, 1kHz 80% Modulation, 80 ~ 1000MHz
IEC61000-4-4 Electrical Fast Transient Immunity: Level 2, 1KV each line, Capacitance coupling
IEC61000-4-5 Surge: Level 2, 42Ω Impedance, Figure 11 (L-L 500V, L-E 1KV)
IEC61000-4-6 Conducted Immunity: Level 2, 3V/130dB, 150KHz ~ 80MHz, 2s Dwell, Clamp Injection
IEC61000-4-9 Pulsed Magnetic Field Immunity: Level 3, 100A/m, 10 Second pulse interval
IEC55022 Emission: Class B, 30dB @ 30-220MHz, 37dB @ 230-1000MHz
Pressure Port Options Dim A (inches) [mm] Recommended Tightening Torque (Nm)
2 = 1/4-19 BSP Male .43 [11.0] 30
4 = 7-16-20 UNF Male SAE J514 w/ O-Ring .36 [9.1] 19
5 = 1/4-18 NPT Male .56 [14.2] 34
6 = 1/8-27 NPT Male .38 [9.7] 16
P = 7/16-20UNF Female w/ Integral Valve Depressor .54 [13.7] 19
Q = M10 x 1.0mm Male .38 [9.6] 10
Others available upon request
Connector Vendor Pin Plating
Packard powerandsignal.com 0.003 – 0.005 mm Sn
Sumitomo sumitomokenki.com 0.003 mm Sn over 0.0005 – 0.001 mm Cu
AMP te.com 0.0004 mm Au over 0.0013 mm Ni
U7100
Pressure Transducer
U7100 www.meas-spec.com December 2012
4/6
DIMENSIONS
U7100
Pressure Transducer
U7100 www.meas-spec.com December 2012
5/6
CHARTS
Chart A. Pressure Transfer Function
Supply = 5V
Chart B. OEM Custom Calibration
High/Low Rail values can be adjusted by circuit
U7100
Pressure Transducer
U7100 www.meas-spec.com December 2012
6/6
ORDERING INFORMATION
NORTH AMERICA EUROPE ASIA
Measurement Specialties
45738 Northport Loop West
Fremont, CA 94538
Tel: 1-800-767-1888
Fax: 1-510-498-1578
Sales: pfg.cs.amer@meas-spec.com
Measurement Specialties
(Europe), Ltd.
26 Rue des Dames
78340 Les Clayes-sous-Bois, France
Tel: +33 (0) 130 79 33 00
Fax: +33 (0) 134 81 03 59
Sales: pfg.cs.emea@meas-spec.com
Measurement Specialties
(China), Ltd.
No. 26 Langshan Road
Shenzhen High-Tech Park (North)
Nanshan District, Shenzhen 518057
China
Tel: +86 755 3330 5088
Fax: +86 755 3330 5099
Sales: pfg.cs.asia@meas-spec.com
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for
inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the
manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement
Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does
Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims
any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different
applications. All operating parameters must be validated for each customer application by customer’s technical experts. Measurement
Specialties, Inc. does not convey any license under its patent rights nor the rights of others.
U7138-100PG-2W0000
Specials (nnnn = Custom Drawing)
Port Material (W = 316L ST STL)
Pressure Port (See Pressure Port Options Table)
Type (G = Gage, A = Absolute, S = Sealed Gage)
Pressure Range (See Pressure Range Table)
Connection (7 = AMP Connector, 8 = Sumitomo Connector HV040,
Output (3 = 0.5 - 4.5V)
Model
9 = Packard Connector [Supply; PIN B])