Counter
LC2H Total Counter
RoHS compliance
Features
7-segment LCD with 8.7 mm 0.343 in
character height (total digits: 8)
Backlight can be switched between green and red (for
backlight type)
Counting Speed Switchable between 30 Hz
and 2 kHz (for panel mounting type)
Battery Replacement Easy on Environment
IP66 compliant for resistance against
negative environmental inuences
(only when panel surface uses rubber
packing) (for installation frame type)
Finger protection
Screw terminals are constructed to
protect ngers to ensure safety (for screw
terminal section)
Replaceable panel cover
Panel design can be changed from standard (ash
gray) to black (sold separately)
IP66
PRODUCT TYPES
Note: There is no front reset button on the PC board mounting type.
Installation
type Input method Counting
speed Backlight
Front reset
button
Model No.
One-touch
installation
type
Non-voltage input type
30 Hz/2 kHz
switchable
No Yes LC2H-FE-2KK
Voltage input type (4.5 to 30 V DC) No Yes LC2H-FE-DL-2KK
Yes Yes LC2H-FE-DL-2KK-B
Free voltage input type (24 to 240 V AC/DC)
30 Hz No Yes LC2H-FE-FV-30
Installation
frame type
Non-voltage input type
30 Hz/2 kHz
switchable
No Yes LC2H-F-2KK
Voltage input type (4.5 to 30 V DC) No Yes LC2H-F-DL-2KK
Yes Yes LC2H-F-DL-2KK-B
Free voltage input type (24 to 240 V AC/DC) 30 Hz No Yes LC2H-F-FV-30
Panel mounting type
Notes: 1) Please ask us about types without front reset button.
2)Productswithoutbacklightarelistedasstandardtypesunder"Specications".
PC board mounting type
Input method Counting
speed Backlight Front reset
button Model No.
Non-voltage input type 2 kHz No Ye s LC2H-C-2K-N
30 Hz No Yes LC2H-C-30-N
General terms and conditions ............. F-3 Selection guide ............................. P.1401
Typical counter applications ......... P.1402 Options ......................................... P.1428
* Refer to our website for details of product.
One-touch installation type
Panel mounting type
Installation frame type
PC board mounting type
panasonic.net/id/pidsx/global
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Timers
Time Switches
Counters
Hour Meters
Options
Limit Switches
Temperature
Controllers
Solenoids
Fan Motors
Selection
Guide
Applications
LC2H series
LC4H series
1404
LC2H Total Counter
CAUTIONS FOR USE
Non-voltage input type
Common to both the panel mounting type, and the PC board mounting type
• Never apply voltage to the non-voltage input type.
This will damage the internal elements.
Also, since there is a possibility of erroneous operation,
do not connect in parallel the inputs of a non-voltage
input type and another counter from a single input signal.
Sincethecurrentowisverysmallfromthecount
input and reset input terminals ( and on the panel
mounting type and terminals to and to on the
PC board mounting type) please use relays and switches
with high contact reliability.
• When inputting with an open collector of a transistor, use
a transistor for small signals in which ICBOis1μAorless
and always input with no voltage.
When wiring, try to keep all the input lines to the count and
reset inputs as short as possible and avoid running them
together with high voltage and power transmission lines or in a
power conduit.
Also,malfunctionsmightoccuriftheoatingcapacitanceof
these wires exceeds 500 pF (10 m 32.808 ft for parallel wires
of 2 mm
2
0.003 in
2
).
Whenusing2kHzmode,usewithawiringoatingcapacitance
of 120 pF (3 m 9.843 ft for parallel wires of 2 mm
2
0.003 in
2
).
In particular, when using shielded wiring, be careful of the
capacitance between wires.
PC board mounting type
• For external power supply use manganese dioxide or
lithium batteries (CR type: 3V).
Alwaysresetafterexternalpowerisappliedandconrm
that the display reads "0".
• Make the wiring from the battery to the counter unit as
short as absolutely possible. Also, be careful of polarity.
• Calculate battery life with the following formula.
t = A/I
t: battery life [h]
I: LC2H current consumption [mA]
A: battery capacity until minimum
operation voltage is reached [mAh]
Hand solder to the lead terminal.
Do not dip solder. With the tip of the soldering iron at 300 °C 572 °F
perform soldering within 3 seconds (for 30 to 60 W soldering iron).
Voltage input type
• Be aware that applying more than 30 V DC to count input
terminals and , and reset input terminals and
will cause damage to the internal elements.
• For external resetting use H level (application of 4.5 to
30 V DC) between reset terminals and of the rear
terminals. In this case, connect (+) to terminal 3 and (-)
to terminal . This is the valid polarity; therefore, the
counter will not work if reversed.
When wiring, try to keep all the input lines to the count and reset
inputs as short as possible and avoid running them together with
high voltage and power transmission lines or in a power conduit.
Also,malfunctionsmightoccuriftheoatingcapacitanceof
these wires exceeds 500 pF (10 m 32.808 ft for parallel wires of
2 mm
2
0.003 in
2
).
Free voltage input type
• Use count input terminals and for free voltage input
and reset terminals and for non-voltage input.
• Be aware that the application of voltage that exceeds the
voltage range of the H level to the count input terminal,
and the application of voltage to the reset input terminal,
can cause damage to the internal elements.
Sincethecurrentowisverysmallfromresetinput
terminal , please use relays and switches with high
contact reliability.
• When inputting a reset with an open collector of a
transistor, use a transistor for small signals in which ICBO
is1μAorlessandalwaysinputwithnovoltage.
• To reset externally, short reset input terminals and
on the rear.
• Input uses a high impedance circuit; therefore, erroneous
operationmayoccuriftheinuenceofinductionvoltage
is present. If you plan to use wiring for the input signal
that is 10 m 32.808 ft or longer (wire capacitance 120
pF/m at normal temperature), we recommend the use of
aCRlterortheconnectionofableederresistor.
Backlight luminance
To prevent varying luminance among backlights when
using multiple backlight types, please use the same
backlight power supply.
22
52
RedGreen
5
626
24 V DC 24 V DC
How to reset multiple panel mounting type
counters all at once (input is the same for count)
Non-voltage input type
3or
DTr
4 3 4 3 4
D D
Notes: 1) Use the following as a guide for choosing transistors used for
input (Tr).
Leakagecurrent<1μA
2) Use as small a diode (D) as possible in the forward voltage
so that the voltage between terminals 3 and 4 during reset
input meets the standard value (0.5 V).
(AtIF=20μA,forwardvoltage:Max.0.1V)
Voltage input type
3or
+V +V
R
Tr
4 3 4 3 4 3 4
Note: Make sure that H (reset ON) level is at least 4.5 V.
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Timers
Time
Switches
Counters
Hour
Meters
Options
Limit
Switches
Temperature
Controllers
Solenoids
Fan
Motors
Selection
Guide
Applications
LC2H
series
LC4H
series