* Refer to our website for details of product. 1403 Counter FIBER SENSORS Related Information LC2H Total Counter General terms and conditions.............. F-3 Typical counter applications.......... P.1402 LASER SENSORS PHOTOELECTRIC SENSORS Panel mounting type MICRO PHOTOELECTRIC SENSORS * 7-segment LCD with 8.7 mm 0.343 in character height (total digits: 8) Backlight can be switched between green and red (for backlight type) One-touch installation type Installation frame type PC board mounting type PARTICULAR USE SENSORS SENSOR OPTIONS panasonic.net/id/pidsx/global SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS Selection guide.............................. P.1401 Options.......................................... P.1428 Features AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS RoHS compliance * Counting Speed Switchable between 30 Hz and 2 kHz (for panel mounting type) * Battery Replacement Easy on Environment * IP66 compliant for resistance against negative environmental influences (only when panel surface uses rubber packing) (for installation frame type) * Finger protection Screw terminals are constructed to protect fingers to ensure safety (for screw terminal section) * Replaceable panel cover Large display in a small body Panel design can be changed from standard (ash gray) to black (sold separately) IP66 PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS PRODUCT TYPES Panel mounting type Installation type Counters Hour Meters Options Limit Switches Temperature Controllers Solenoids Fan Motors Backlight No Yes LC2H-FE-2KK Voltage input type (4.5 to 30 V DC) 30 Hz/2 kHz switchable No Yes LC2H-FE-DL-2KK Yes Yes LC2H-FE-DL-2KK-B Free voltage input type (24 to 240 V AC/DC) 30 Hz No Yes LC2H-FE-FV-30 No Yes LC2H-F-2KK Voltage input type (4.5 to 30 V DC) 30 Hz/2 kHz switchable No Yes LC2H-F-DL-2KK Free voltage input type (24 to 240 V AC/DC) 30 Hz Non-voltage input type One-touch installation type Non-voltage input type Timers Time Switches Counting speed Input method Installation frame type Model No. Yes Yes LC2H-F-DL-2KK-B No Yes LC2H-F-FV-30 Counting speed Backlight Front reset button 2 kHz No Yes LC2H-C-2K-N 30 Hz No Yes LC2H-C-30-N Notes: 1) Please ask us about types without front reset button. 2) Products without backlight are listed as standard types under "Specifications". PC board mounting type Input method Selection Guide Applications Non-voltage input type LC2H series Note: There is no front reset button on the PC board mounting type. LC4H series Front reset button Model No. LC2H Total Counter 1404 CAUTIONS FOR USE Non-voltage input type Common to both the panel mounting type, and the PC board mounting type * Never apply voltage to the non-voltage input type. This will damage the internal elements. Also, since there is a possibility of erroneous operation, do not connect in parallel the inputs of a non-voltage input type and another counter from a single input signal. * Since the current flow is very small from the count input and reset input terminals ( and on the panel mounting type and terminals to and to on the PC board mounting type) please use relays and switches with high contact reliability. * When inputting with an open collector of a transistor, use a transistor for small signals in which ICBO is 1 A or less and always input with no voltage. * When wiring, try to keep all the input lines to the count and reset inputs as short as possible and avoid running them together with high voltage and power transmission lines or in a power conduit. Also, malfunctions might occur if the floating capacitance of these wires exceeds 500 pF (10 m 32.808 ft for parallel wires of 2 mm2 0.003 in2). When using 2 kHz mode, use with a wiring floating capacitance of 120 pF (3 m 9.843 ft for parallel wires of 2 mm2 0.003 in2). In particular, when using shielded wiring, be careful of the capacitance between wires. PC board mounting type * For external power supply use manganese dioxide or lithium batteries (CR type: 3V). * Always reset after external power is applied and confirm that the display reads "0". * Make the wiring from the battery to the counter unit as short as absolutely possible. Also, be careful of polarity. * Calculate battery life with the following formula. t = A/I t: battery life [h] I: LC2H current consumption [mA] A: battery capacity until minimum operation voltage is reached [mAh] * Hand solder to the lead terminal. Do not dip solder. With the tip of the soldering iron at 300 C 572 F perform soldering within 3 seconds (for 30 to 60 W soldering iron). Voltage input type * Be aware that applying more than 30 V DC to count input terminals and , and reset input terminals and will cause damage to the internal elements. * For external resetting use H level (application of 4.5 to 30 V DC) between reset terminals and of the rear terminals. In this case, connect (+) to terminal 3 and (-) to terminal . This is the valid polarity; therefore, the counter will not work if reversed. * When wiring, try to keep all the input lines to the count and reset inputs as short as possible and avoid running them together with high voltage and power transmission lines or in a power conduit. Also, malfunctions might occur if the floating capacitance of these wires exceeds 500 pF (10 m 32.808 ft for parallel wires of 2 mm2 0.003 in2). FIBER SENSORS LASER SENSORS Free voltage input type * Use count input terminals and for free voltage input and reset terminals and for non-voltage input. * Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input terminal, can cause damage to the internal elements. * Since the current flow is very small from reset input terminal , please use relays and switches with high contact reliability. * When inputting a reset with an open collector of a transistor, use a transistor for small signals in which ICBO is 1 A or less and always input with no voltage. * To reset externally, short reset input terminals and on the rear. * Input uses a high impedance circuit; therefore, erroneous operation may occur if the influence of induction voltage is present. If you plan to use wiring for the input signal that is 10 m 32.808 ft or longer (wire capacitance 120 pF/m at normal temperature), we recommend the use of a CR filter or the connection of a bleeder resistor. How to reset multiple panel mounting type counters all at once (input is the same for count) Non-voltage input type D MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC D D 3 4 PHOTOELECTRIC SENSORS 3 4 HUMAN MACHINE INTERFACES Tr or 3 4 ENERGY MANAGEMENT SOLUTIONS Notes: 1) Use the following as a guide for choosing transistors used for input (Tr). Leakage current < 1 A 2) Use as small a diode (D) as possible in the forward voltage so that the voltage between terminals 3 and 4 during reset input meets the standard value (0.5 V). (At IF = 20 A, forward voltage: Max. 0.1 V) FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Voltage input type 3 4 3 4 +V R Tr or 3 4 +V 3 4 Timers Time Switches Note: Make sure that H (reset ON) level is at least 4.5 V. Counters Hour Meters Backlight luminance To prevent varying luminance among backlights when using multiple backlight types, please use the same backlight power supply. 24 V DC 2 5 2 Green 5 Options Limit Switches Temperature Controllers Solenoids Fan Motors 2 2 6 Red 6 24 V DC Selection Guide Applications LC2H series LC4H series