Anti-Parallel Parallel
2
1
323
414
SOT-227
2
1
3
4
APT2X100D120J APT2X101D120J
PRELIMINARY
Characteristic / Test Conditions
Maximum D.C. Reverse Voltage
Maximum Peak Repetitive Reverse Voltage
Maximum Working Peak Reverse Voltage
Maximum Average Forward Current (TC = 40°C, Duty Cycle = 0.5)
RMS Forward Current
Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms)
Operating and StorageTemperature Range
Lead Temperature: 0.063" from Case for 10 Sec.
Symbol
VR
VRRM
VRWM
IF(AV)
IF(RMS)
IFSM
TJ,TSTG
TL
Symbol
VF
IRM
CT
LS
Characteristic / Test Conditions
IF = 100A
Maximum Forward Voltage IF = 200A
IF = 100A, TJ = 150°C
Maximum Reverse Leakage Current VR = VR Rated
VR = VR Rated, TJ = 125°C
Junction Capacitance, VR = 200V
Series Inductance (Lead to Lead 5mm from Base)
STATIC ELECTRICAL CHARACTERISTICS
UNIT
Volts
Amps
°C
UNIT
Volts
µA
pF
nH
MIN TYP MAX
2.5
2.5
2.0
250
500
116
20
APT2X100/2X101D120J
1200
100
170
1000
-55 to 150
300
MAXIMUM RATINGS All Ratings: TC = 25°C unless otherwise specified.
PRODUCT BENEFITS
Low Losses
Low Noise Switching
Cooler Operation
Higher Reliability Systems
Increased System Power
Density
PRODUCT FEATURES
Ultrafast Recovery Times
Soft Recovery Characteristics
Popular SOT-227 Package
Low Forward Voltage
High Blocking Voltage
Low Leakage Current
PRODUCT APPLICATIONS
Anti-Parallel Diode
-Switchmode Power Supply
-Inverters
Free Wheeling Diode
-Motor Controllers
-Converters
Snubber Diode
Uninterruptible Power Supply (UPS)
Induction Heating
High Speed Rectifiers
DUAL DIE ISOTOP® PACKAGE
ULTRAFAST SOFT RECOVERY DUAL RECTIFIER DIODES
053-1201 Rev A
USA
405 S.W. Columbia Street Bend, Oregon 97702-1035 Phone: (541) 382-8028 FAX: (541) 388-0364
EUROPE
Avenue J.F. Kennedy Bât B4 Parc Cadéra Nord F-33700 Merignac - France Phone: (33) 5 5792 1515 FAX: (33) 5 56 47 97 61
APT Website - http://www.advancedpower.com
APT2X100D120J 1200V 100A
APT2X101D120J 1200V 100A
PRELIMINARY
MIN TYP MAX
80 95
130
215
220
220
28 38
52 65
2100
6100
26
26
800
400
UNIT
ns
Amps
nC
Volts
A/µs
APT2X100/2X101D120J
Characteristic
Reverse Recovery Time, IF = 1.0A, diF/dt = -15A/µs, VR = 30V, TJ = 25°C
Reverse Recovery Time TJ = 25°C
IF = 100A, diF/dt = -800A/µs, VR = 650V TJ = 100°C
Forward Recovery Time TJ = 25°C
IF = 100A, diF/dt = 800A/µs, VR = 650V TJ = 100°C
Reverse Recovery Current TJ = 25°C
IF = 100A, diF/dt = -800A/µs, VR = 650V TJ = 100°C
Recovery Charge TJ = 25°C
IF = 100A, diF/dt = -800A/µs, VR = 650V TJ = 100°C
Forward Recovery Voltage TJ = 25°C
IF = 100A, diF/dt = 800A/µs, VR = 650V TJ = 100°C
Rate of Fall of Recovery Current TJ = 25°C
IF = 100A, diF/dt = -800A/µs, VR = 650V (See Figure 10) TJ = 100°C
DYNAMIC CHARACTERISTICS
Symbol
trr1
trr2
trr3
tfr1
tfr2
IRRM1
IRRM2
Qrr1
Qrr2
Vfr1
Vfr2
diM/dt
THERMAL AND MECHANICAL CHARACTERISTICS
Characteristic / Test Conditions
Junction-to-Case Thermal Resistance
Junction-to-Ambient Thermal Resistance
RMS Voltage (50-60 Hz Sinusoidal Waveform from Terminals to Mounting Base for 1 Min.)
Package Weight
Maximum Torque (Mounting = 8-32 or 4mm Machine and Terminals = 4mm Machine)
Symbol
RθJC
RθJA
VIsolation
WT
Torque
MIN TYP MAX
0.42
20
2500
1.03
29.2
13.6
1.5
UNIT
°C/W
Volts
oz
gm
lb•in
N•m
053-1201 Rev A
Anode 1
31.5 (1.240)
31.7 (1.248)
Dimensions in Millimeters and (Inches)
7.8 (.307)
8.2 (.322)
30.1 (1.185)
30.3 (1.193)
38.0 (1.496)
38.2 (1.504)
14.9 (.587)
15.1 (.594)
11.8 (.463)
12.2 (.480)
8.9 (.350)
9.6 (.378)
Hex Nut M4 H100
(4 places)
0.75 (.030)
0.85 (.033) 12.6 (.496)
12.8 (.504)
25.2 (0.992)
25.4 (1.000)
1.95 (.077)
2.14 (.084)
Anode 2
Anti-parallel Parallel
Cathode 1
r = 4.0 (.157)
(2 places) 4.0 (.157)
4.2 (.165)
(2 places)
W=4.1 (.161)
W=4.3 (.169)
H=4.8 (.187)
H=4.9 (.193)
(4 places)
3.3 (.129)
3.6 (.143)
Cathode 2 Anode 1
Cathode 2 Anode 2
Cathode 1
APT2X100D120J APT2X101D120J
APT Reserves the right to change, without notice, the specifications and information contained herein.
ISOTOP® is a Registered Trademark of SGS Thomson.
SOT-227 Package Outline