Smart Fiber Amplifier Units E3NX-FA CSM_E3NX-FA_DS_E_12_1 A Smart Fiber Amplifier Unit with Ultra-stable Detection and Ultra-easy Setup * Improved basic performance with 1.5 times the sensing distance and approx. 1/10th the minimum sensing object.* * Ultra-easy setup with Smart Tuning with a light intensity adjustment range expanded 20 times to 40,000:1. Optimum stable detection achieved with light intensity adjustment even for saturated incident light. * White on black display characters for high visibility. * Solution Viewer that shows the passing time and difference in incident levels and Change Finder that allows you to see display values even for fast workpieces. * Compared to the E3X-HD. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to the Safety Precautions on page 12. Ordering Information Fiber Amplifier Units (Dimensions pages 13 and 15) Type Connecting method Appearance Model Inputs/outputs NPN output PNP output Pre-wired (2 m) 1 output E3NX-FA11 2M E3NX-FA41 2M Wire-saving Connector 1 output E3NX-FA6 E3NX-FA8 Pre-wired (2 m) 2 outputs + 1 input E3NX-FA21 2M E3NX-FA51 2M 1 output + 1 input E3NX-FA7 E3NX-FA9 2 outputs E3NX-FA7TW E3NX-FA9TW 1 output + 1 input E3NX-FA24 E3NX-FA54 2 outputs --- E3NX-FA54TW --- E3NX-FA0 Standard models Advanced models Wire-saving Connector M8 Connector Model for Sensor Communications Unit * Connector for Sensor Communications Unit * A Sensor Communications Unit is required if you want to use the Fiber Amplifier Unit on a network. 1 E3NX-FA Accessories (Sold Separately) Wire-saving Connectors (Required for models for Wire-saving Connectors.) (Dimensions page 15) Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately. *Protective stickers are provided. Type Appearance Cable length No. of conductors Model Master Connector 4 E3X-CN21 Slave Connector 2 E3X-CN22 3 E3X-CN11 Applicable Fiber Amplifier Units E3NX-FA7 E3NX-FA7TW E3NX-FA9 E3NX-FA9TW 2m Master Connector E3NX-FA6 E3NX-FA8 Slave Connector 1 E3X-CN12 Sensor I/O Connectors (Required for models for M8 Connectors.) (Dimensions page 15) Connectors are not provided with the Fiber Amplifier Unit and must be ordered separately. Size Cable Appearance Cable type Straight M8 5m Standard cable 2m L-shaped A Mounting Bracket is not provided with the Fiber Amplifier Unit. It must be ordered separately as required. XS3F-M422-402-A XS3F-M422-405-A Related Products Sensor Communications Units Quantity Type E39-L143 1 Sensor Communications Unit for EtherCAT E3NW-ECT Sensor Communications Unit for CompoNet E3NW-CRT Sensor Communications Unit for CC-Link E3NW-CCL Distributed Sensor Unit * E3NW-DS A DIN Track is not provided with the Fiber Amplifier Unit. It must be ordered separately as required. Type Model PFP-100N Shallow type, total length: 0.5 m PFP-50N Deep type, total length: 1 m PFP-100N2 1 End Plate (Dimensions page 16) Two End Plates are provided with the Sensor Communications Unit. End Plates are not provided with the Fiber Amplifier Unit. They must be ordered separately as required. Model PFP-M Appearance Model Quantity Shallow type, total length: 1 m Appearance XS3F-M421-405-A 4-wire Model DIN Track (Dimensions page 16) Appearance XS3F-M421-402-A 5m Mounting Bracket (Dimensions page 16) Appearance Model 2m Quantity 1 Refer to your OMRON website for details. * The Distributed Sensor Unit can be connected to any of the Sensor Communications Units. EtherCAT(R) is a registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. CompoNet is a registered trademark of the ODVA. CC-Link is a registered trademark of Mitsubishi Electric Corporation. The trademark is managed by the CC-Link Partner Association. 2 E3NX-FA Ratings and Specifications Type Item Inputs/ outputs Standard models Model for Sensor Communications Unit Advanced models NPN output E3NX-FA11 E3NX-FA6 E3NX-FA21 E3NX-FA7 E3NX-FA7TW E3NX-FA24 --- PNP output E3NX-FA41 E3NX-FA8 E3NX-FA51 E3NX-FA9 E3NX-FA9TW E3NX-FA54 E3NX-FA54TW Connecting method Pre-wired Wire-saving Connector Pre-wired Wire-saving Connector M8 Connector Outputs 1 output 2 outputs 1 output 2 outputs 1 output 2 outputs External inputs --- 1 input 1 input --- 1 input --- Light source (wavelength) Red, 4-element LED (625 nm) Power supply voltage 10 to 30 VDC, including 10% ripple (p-p) Power consumption2 At Power Supply Voltage of 24 VDC Standard Models or Model for Sensor Communications Unit: Normal mode: 960 mW max. (Current consumption: 40 mA max.), Eco ON: 720 mW max. (Current consumption: 30 mA max.), Eco LO: 840 mW max. (Current consumption: 35 mA max.) Advanced Models: Normal mode: 1,080 mW max. (Current consumption: 45 mA max.), Eco ON: 840 mW max. (Current consumption: 35 mA max.), Eco LO: 960 mW max. (Current consumption: 40 mA max.) E3NX-FA0 Connector for Sensor Communications Unit --- 1 Supplied from the connector through the Sensor Communications Unit Load power supply voltage: 30 VDC max., open-collector output Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max. Residual voltage: At load current of less than 10 mA: 1 V max. At load current of 10 to 100 mA: 2 V max. Control output --- OFF current: 0.1 mA max. Refer to 3. --- Refer to 3. External inputs --- Indicators 7-segment displays (Sub digital display: green, Main digital display: white) Display direction: Switchable between normal and reversed. OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on models with 2 outputs) --- Protection circuits Power supply reverse polarity protection, output short-circuit protection, and output reve rse polarity protection Power supply reverse polarity protection and output shortcircuit protection Super-high-speed mode (SHS)4 Operate or reset for model with 1 output: 30 s, with 2 outputs: 32 s Response time High-speed mode (HS) Operate or reset: 250 s Standard mode (Stnd) Operate or reset: 1 ms Giga-power mode (GIGA) Operate or reset: 16 ms Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (99% to 99%)) or manual adjustment Sensitivity adjustment Maximum connectable Units 30 Super-high-speed mode (SHS)4 No. of Units High-speed mode (HS) for mutual interference Standard mode (Stnd) prevention Giga-power mode (GIGA) 0 Functions With E3NW-ECT: 30 units 5 With E3NW-CRT: 16 units With E3NW-CCL: 16 units 10 10 10 Automatic power control (APC) Always enabled. Dynamic power control (DPC) Provided Timer Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms Zero reset Negative values can be displayed. (Threshold value is shifted.) Resetting settings6 Select from initial reset (factory defaults) or user reset (saved settings). *1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table. PLC operation via Communications Unit enables reading detected values and changing settings. *2. At Power Supply Voltage of 10 to 30 VDC. Standard Models or Model for Sensor Communications Unit: Normal mode: 1,080 mW max. (Current consumption: 36 mA max. at 30 VDC, 108 mA max. at 10 VDC) Eco ON: 880 mW max. (Current consumption: 28 mA max. at 30 VDC, 88 mA max. at 10 VDC) Eco LO: 980 mW max. (Current consumption: 32 mA max. at 30 VDC, 98 mA max. at 10 VDC) Advanced Models: Normal mode: 1,230 mW max. (Current consumption: 41 mA max. at 30 VDC, 123 mA max. at 10 VDC) Eco ON: 1,030 mW max. (Current consumption: 33 mA max. at 30 VDC, 103 mA max. at 10 VDC) Eco LO: 1,130 mW max. (Current consumption: 37 mA max. at 30 VDC, 113 mA max. at 10 VDC) *3. The following details apply to the input. Contact input (relay or switch) Non-contact input (transistor) NPN ON: Shorted to 0 V (Sourcing current: 1 mA max.). OFF: Open or shorted to Vcc. ON: 1.5 V max. (Sourcing current: 1 mA max.) OFF: Vcc 1.5 V to Vcc (Leakage current: 0.1 mA max.) PNP ON: Shorted to Vcc (Sinking current: 3 mA max.). OFF: Open or shorted to 0 V. ON: Vcc 1.5 V to Vcc (Sinking current: 3 mA max.) OFF: 1.5 V max. (Leakage current: 0.1 mA max.) Input time*3-1 ON: 9 ms min. OFF: 20 ms min. *3-1.Input time is 25 ms (ON)/(OFF) only when (in tUnE) or (in PtUn) input is selected. *4. The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode. *5. When connected to an OMRON NJ-series Controller. *6. The bank is not reset by the user reset function or saved by the user save function. 3 E3NX-FA Type Model for Sensor Communications Unit Advanced models NPN output E3NX-FA11 E3NX-FA6 E3NX-FA21 E3NX-FA7 E3NX-FA7TW E3NX-FA24 PNP output E3NX-FA41 E3NX-FA8 E3NX-FA51 E3NX-FA9 E3NX-FA9TW E3NX-FA54 E3NX-FA54TW Connecting method Item Standard models Pre-wired Wiresaving Connector Wire-saving Connector Pre-wired --- M8 Connector Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed). Bank switching Select from banks 1 to 4. Power tuning Select from ON or OFF. Output 1 Select from normal detection mode or area detection mode. Select from normal detection mode, alarm output mode, or error output mode. --- Functions --- Select from input OFF, tuning, power tuning, emission OFF, zero reset, or bank switching. Select from normal detection mode, alarm output mode, or error output mode. --- Select from normal detection mode, alarm output mode, or error output mode. --- Select from input OFF, tuning, power tuning, emission OFF, zero reset, or bank switching. --- External input --- Hysteresis width Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999. Ambient illumination (Receiver side) Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max. Operating: Groups of 1 or 2 Amplifier Units: 0 to 55C, Groups of 3 to 10 Amplifier Units: 0 to 50C, Groups of 11 to 16 Amplifier Units: 0 to 45C, Groups of 17 to 30 Amplifier Units: 0 to 40C Storage: -30 to 70C (with no icing or condensation) Ambient temperature range8 Operating: Groups of 1 or 2 Amplifier Units: -25 to 55C, Groups of 3 to 10 Amplifier Units: -25 to 50C, Groups of 11 to 16 Amplifier Units: -25 to 45C, Groups of 17 to 30 Amplifier Units: -25 to 40C Storage: -30 to 70C (with no icing or condensation) Ambient humidity range Operating and storage: 35% to 85% (with no condensation) Altitude 2,000 m max. Installation environment Pollution degree 3 (as per IEC 60947-1) Insulation resistance 20 M min. (at 500 VDC) Dielectric strength 1,000 VAC at 50/60 Hz for 1 min Vibration resistance (destruction) 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions 150 m/s2 for 3 times each in X, Y, and Z directions 2 Shock resistance (destruction) 500 m/s for 3 times each in X, Y, and Z directions Weight (packed state/Sensor only) Approx. 115 g/ Approx. 60g/ Approx. 115 g/ approx. 75 g approx. 20g approx. 75 g Approx. 60g/approx. 20g Accessories Connector for Sensor Communications Unit Eco mode7 Output 2 Materials E3NX-FA0 Case Polycarbonate (PC) Cover Polycarbonate (PC) Cable PVC Approx. 65 g/ approx. 25 g Instruction Manual *7. Eco LO is supported for Amplifier Units manufactured in July 2014 or later. *8. When the number of connected units is 11 or more, the ambient temperature is less than 50C. 4 E3NX-FA Sensing Distances Threaded Models Sensing method Sensing direction Size Right-angle Throughbeam M4 Straight M3 Right-angle M4 M6 M3 Reflective M4 Straight M6 Model E32-T11N 2M E32-LT11N 2M E32-T11R 2M E32-LT11 2M E32-LT11R 2M E32-C31N 2M E32-C21N 2M E32-D21N 2M E32-C11N 2M E32-LD11N 2M E32-D21R 2M E32-C31 2M E32-C31M 1M Giga mode 3,000 4,000*1 3,000 4,000*1 4,000*1 160 440 1,260 1,170 1,260 Sensing distance (mm) Standard mode High-speed mode 1,500 1,050 4,000*1 3,450 1,500 1,050 4,000*1 4,000*1 4,000*1 3,450 75 69 190 130 520 360 520 480 520 360 Super-high-speed mode 280 920 280 1,080 920 14 39 100 100 100 210 90 60 16 490 220 150 44 E32-D211R 2M E32-D11R 2M E32-CC200 2M 210 1,260 2,100 90 520 900 60 360 600 16 100 180 E32-LD11 2M E32-LD11R 2M 1,290 1,260 540 520 370 360 110 100 Sensing distance (mm) Standard mode High-speed mode 370 220 600 330 1,500 1,050 670 390 90 60 Super-high-speed mode 60 90 280 100 16 *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Cylindrical Models Sensing method Throughbeam Sensing direction Size 1 dia. 1.5 dia. 3 dia. Top-view Side-view 1.5 dia. 1.5 dia. + 0.5 dia. Reflective 3 dia. Top-view 3 dia. + 0.8 dia. Model E32-T223R 2M E32-T22B 2M E32-T12R 2M E32-T14LR 2M E32-D22B 2M Giga mode 670 1,020 3,000 1,120 210 E32-D43M 1M 42 E32-D22R 2M 210 450 1,050 100 45 E32-D221B 2M E32-D32L 2M E32-D33 2M 18 12 4 90 60 16 210 450 130 300 40 90 30 8 Sensing distance (mm) Standard mode High-speed mode 1,500 1,050 Super-high-speed mode 280 Flat Models Sensing method Throughbeam Reflective Sensing direction Top-view Side-view Flat-view Top-view Side-view Flat-view Model E32-T15XR 2M E32-T15YR 2M E32-T15ZR 2M E32-D15XR 2M E32-D15YR 2M E32-D15ZR 2M Giga mode 3,000 1,120 670 390 100 1,260 520 360 100 300 150 78 24 Sensing distance (mm) Standard mode High-speed mode 150 75 370 220 130 75 450 250 1,500 1,050 45 30 79 67 18 12 9 6 45 30 Super-high-speed mode 20 60 20 68 280 8 14 4 2 8 Sleeve Models Sensing method Sensing direction Side-view Throughbeam Top-view Side-view Reflective Top-view Model E32-T24R 2M E32-T24E 2M E32-T33 1M E32-T21-S1 2M E32-TC200BR 2M E32-D24R 2M E32-D24-S2 2M E32-D43M 1M E32-D331 2M E32-D33 2M E32-D32-S1 0.5M E32-D31-S1 0.5M E32-DC200F4R 2M E32-D22-S1 2M E32-D21-S3 2M E32-DC200BR 2M E32-D25-S3 2M Giga mode 250 670 220 760 3,000 100 180 42 21 100 94 40 27 7 210 90 60 16 370 160 100 30 1,260 370 520 160 360 100 100 30 5 E3NX-FA Small-spot, Reflective Models Type Variable spot Parallel light Integrated lens Spot diameter Models Giga mode Standard mode High-speed mode 0.1 to 0.6 dia. 6 to 15 E32-C42 1M + E39-F3A Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. 0.3 to 1.6 dia. 10 to 30 E32-C42 1M + E39-F17 Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm. 4 dia. 0 to 20 E32-C31 2M + E39-F3C E32-C31N 2M + E39-F3C 5 E32-C42S 1M Spot diameter of 0.1 mm at 5 mm. 6 dia. 50 E32-L15 2M Spot diameter of 6 mm at 50 mm. E32-C41 1M + E39-F3A-5 Spot diameter of 0.1 mm at 7 mm. 7 0.5 dia. E32-C31 2M + E39-F3A-5 E32-C31N 2M + E39-F3A-5 0.2 dia. E32-C41 1M + E39-F3B 17 0.5 dia. E32-C31 2M + E39-F3B E32-C31N 2M + E39-F3B 3 dia. 50 E32-CC200 2M + E39-F18 E32-C11N 2M + E39-F18 Super-highspeed mode Spot diameter of 4 mm max. at 0 to 20 mm. 0.1 dia. 0.1 dia. Small-spot Sensing distance (mm) Center distance (mm) Spot diameter of 0.5 mm at 7 mm. Spot diameter of 0.2 mm at 17 mm. Spot diameter of 0.5 mm at 17 mm. Spot diameter of 3 mm at 50 mm. High-power Beam Models Type Through-beam models with integrated lens Sensing distance (mm) Sensing direction Aperture angle Right-angle 15 E32-LT11N 2M 4,000*2 4,000*2 3,450 920 10 E32-T17L 10M 20,000*1 20,000*1 20,000*1 8,000 1,080 Top-view Right-angle Top-view Side-view Top-view Side-view Through-beam models with lenses Top-view Side-view Top-view Side-view Top-view Side-view Top-view Reflective models with integrated lens Top-view Giga mode Standard mode High-speed mode Super-highspeed mode E32-LT11 2M 4,000*2 4,000*2 4,000*2 E32-LT11R 2M 4,000*2 4,000*2 3,450 920 30 E32-T14 2M 4,000*2 4,000*2 4,000*2 1,800 12 E32-T11N 2M + E39-F1 4,000*2 4,000*2 4,000*2 2,000 6 E32-T11N 2M + E39-F16 4,000*2 4,000*2 4,000*2 3,600 12 E32-T11R 2M + E39-F1 4,000*2 4,000*2 4,000*2 2,000 6 E32-T11R 2M + E39-F16 4,000*2 4,000*2 4,000*2 3,600 60 E32-T11R 2M + E39-F2 2,170 1,200 750 200 12 E32-T11 2M + E39-F1 4,000*2 4,000*2 4,000*2 1,860 4,000*2 4,000*2 4,000*2 4,000*2 3,450 1,980 1,290 320 15 Side-view Models 6 E32-T11 2M + E39-F16 60 E32-T11 2M + E39-F2 12 E32-T51R 2M + E39-F1 4,000*2 4,000*2 4,000*2 1,500 4,000*2 4,000*2 4,000*2 4,000*2 2,100 1,080 750 200 6 E32-T51R 2M + E39-F16 60 E32-T51R 2M + E39-F2 12 E32-T81R-S 2M + E39-F1 4,000*2 4,000*2 4,000*2 1,000 4,000*2 4,000*2 4,000*2 1,800 1,500 820 540 140 6 E32-T81R-S 2M + E39-F16 60 E32-T81R-S 2M + E39-F2 12 E32-T61-S 2M + E39-F1 4,000*2 4,000*2 4,000*2 1,800 4,000*2 4,000*2 4,000*2 3,100 2,520 1,350 900 240 6 E32-T61-S 2M + E39-F16 60 E32-T61-S 2M + E39-F2 12 E32-T51 2M + E39-F1-33 4,000*2 4,000*2 3,450 1,400 6 E32-T51 2M + E39-F16 4,000*2 4,000*2 4,000*2 4,000*2 4 E32-D16 2M 40 to 4,000 *2 40 to 2,100 40 to 1,350 40 to 480 *1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm. *2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Narrow View Models Sensing method Sensing direction Sensing distance (mm) Aperture angle 1.5 Through-beam Side-view 3.4 4 Models Giga mode E32-A03 2M E32-A03-1 2M E32-A04 2M Standard mode 4,000*1 2,670 High-speed mode Super-highspeed mode 1,800 500 1,920 1,020 670 200 E32-T24SR 2M 4,000*1 3,300 2,190 580 E32-T24S 2M 4,000*1 3,900 2,610 700 E32-T22S 2M 4,000*1 4,000*1 3,750 1,000 *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. 6 E3NX-FA Models for Detection without Background Interference Sensing method Sensing direction Model Sensing distance (mm) Giga mode Standard mode Flat-view Limitedreflective Side-view High-speed mode 0 to 15 E32-L16-N 2M Super-high-speed mode 0 to 12 E32-L24S 2M 0 to 4 E32-L25L 2M 5.4 to 9 (center 7.2) Transparent Object Detection (Retro-reflective Models) Sensing method Retro-reflective Feature Size Models Film detection M3 E32-C31 2M + E39-F3R + E39-RP37 Square --- E32-R16 5M Threaded Sensing distance (mm) Giga mode Standard mode Hex-shaped E32-LR11NP 2M + E39-RP1 Super-high-speed mode 300 --- 370 150 to 1,500 10 to 370 E32-R21 2M M6 High-speed mode 2,020 10 to 250 1,800 1,500 550 Transparent Object Detection (Limited-reflective Models) Sensing method Feature Sensing direction Small size Sensing distance (mm) Giga mode Standard mode Standard/long-distance Super-high-speed mode E32-L16-N 2M 0 to 15 0 to 12 E32-A08 2M 10 to 20 --- E32-A12 2M 12 to 30 --- Flat-view Glass substrate alignment, 70C High-speed mode 0 to 4 E32-L24S 2M Standard Limitedreflective Model Side-view form Side-view E32-L25L 2M Glass substrate mapping, 70C Top-view E32-A09 2M 5.4 to 9 (center 7.2) 15 to 38 --- Chemical-resistant, Oil-resistant Models Sensing method Through-beam Type Sensing direction Oil-resistant Right-angle Chemical/oil-resistant Chemical/oil-resistant at 150C Top-view Semiconductors: Resist stripping; 85C Sensing distance (mm) Giga mode Standard mode High-speed mode Super-high-speed mode E32-T11NF 2M 4,000*1 4,000*1 4,000*1 2,200 E32-T12F 2M 4,000*1 4,000*1 4,000*1 1,600 E32-T11F 2M 4,000*1 4,000*1 3,900 1,000 Side-view E32-T14F 2M 2,100 1,200 750 200 Top-view E32-T51F 2M 4,000*1 4,000*1 2,700 700 Semiconductors: Cleaning, developing, and etching; 60C Reflective Model Top-view E32-L11FP 5M 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) E32-L11FS 5M 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) Chemical/oil-resistant E32-D12F 2M Chemical-resistant cable E32-D11U 2M ---*2 1,260 280 190 60 520 360 100 *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. *2. Even if there is no sensing object, the Sensor will detect light that is reflected by the fluororesin. Bending-resistant Models Sensing method Size 1.5 dia. Through-beam M3 M4 E32-T22B 2M E32-T21 2M E32-T11 2M Square 32-T25XB 2M 1.5 dia. E32-D22B 2M M3 Reflective Model E32-D21 2M 3 dia. E32-D221B 2M M4 E32-D21B 2M M6 Square E32-D11 2M E32-D25XB 2M Sensing distance (mm) Giga mode Standard mode High-speed mode Super-high-speed mode 1,020 600 330 90 3,750 2,020 1,350 360 750 450 250 70 210 90 60 16 450 210 130 40 1,260 520 360 100 360 150 90 30 7 E3NX-FA Heat-resistant Models Sensing method Heat-resistant temperature Through-beam 100C E32-T51R 2M 150C E32-T51 2M 200C E32-T81R-S 2M Sensing distance (mm) Giga mode Standard mode High-speed mode Super-high-speed mode 2,400 1,200 840 225 4,000*1 2,250 1,500 400 1,500 820 540 140 240 350C E32-T61-S 2M 2,520 1,350 900 100C E32-D51R 2M 1,000 420 280 80 150C E32-D51 2M 1,680 670 480 144 200C E32-D81R-S 2M 270 180 300C Reflective Model 630 10 to 20 --- E32-A09H2 2M 20 to 30 (center 25) --- E32-D611-S 2M 350C E32-D61-S 2M 400C 54 E32-A08H2 2M E32-D73-S 2M 630 270 180 54 420 180 120 36 *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Area Detection Models Sensing method Type Through-beam Area Reflective Array Sensing width Model Sensing distance (mm) Giga mode Standard mode High-speed mode Super-high-speed mode E32-T16PR 2M 4,000*1 2,550 1,680 440 E32-T16JR 2M 4,000*1 2,250 1,440 380 30 mm E32-T16WR 2M 4,000*1 3,900 2,550 680 11 mm E32-D36P1 2M 1,050 450 300 90 11 mm *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. Liquid-level Detection Models Sensing method Tube-mounting Liquid contact (heat-resistant up to 200C) Model Sensing distance (mm) Tube diameter Feature 3.2, 6.4, or 9.5 dia Stable residual quantity detection E32-A01 5M Applicable tube: Transparent tube with a diameter of 3.2, 6.4, or 9.5 mm, Recommended wall thickness: 1 mm 8 to 10 dia Mounting at multiple levels E32-L25T 2M Applicable tube: Transparent tube with a diameter of 8 to 10 mm, Recommended wall thickness: 1 mm No restrictions Large tubes E32-D36T 5M Applicable tube: Transparent tube (no restrictions on diameter) --- --- E32-D82F1 4M Liquid-contact type Giga mode Standard mode High-speed mode Super-high-speed mode Vacuum-resistant Models Sensing method Heat-resistant temperature Model E32-T51V 1M Through-beam Sensing distance (mm) Giga mode Standard mode High-speed mode Super-high-speed mode 1,080 600 390 100 120C E32-T51V 1M + E39F1V 2,000*1 2,000*1 2,000*1 520 200C E32-T84SV 1M 2,000*1 1,420 960 260 *1. The fiber length is 1 m on each side, so the sensing distance is given as 2,000 mm. Models for FPD, Semiconductors, and Solar Cells Sensing method Application Glass presence detection Operating temperature 70C Model Sensing distance (mm) Giga mode 300C 70C Limitedreflective Glass substrate mapping Super-high-speed mode 0 to 12 10 to 20 --- E32-A12 2M 12 to 30 --- E32-A09 2M 15 to 38 --- 20 to 30 (center 25) --- E32-A08H2 3M 300C E32-A09H2 2M Wet processes: Cleaning, Resist developing and etching 60C E32-L11FP 5M 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm) Wet process: Resist stripping 85C E32-L11FS 5M 8 to 20 mm from tip of lens (Recommended sensing distance: 11 mm), 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm) E32-A03 2M E32-A03-1 2M Through-beam High-speed mode 0 to 15 E32-L16-N 2M E32-A08 2M Glass substrate alignment Standard mode Wafer mapping 70C E32-A04 2M 4,000*1 2,670 1,800 500 200 1,920 1,020 670 E32-T24SR 2M 4,000*1 3,300 2,190 580 E32-T24S 2M 4,000*1 3,900 2,610 700 *1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm. 8 E3NX-FA I/O Circuit Diagrams NPN Output Model Operation mode Timing chart Light-ON Incident light No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset (Between brown and black leads) E3NX-FA11 E3NX-FA6 Dark-ON Incident light No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset (Between brown and black leads) Light-ON ch1/ Incident light ch2 No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset (Between brown and black (orange) leads) L/D indicator L lit. Dark-ON Light-ON Incident light No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset (Between brown and black leads) E3NX-FA7 E3NX-FA24 Dark-ON Light-ON Incident light No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset (Between brown and black leads) ch1/ Incident light ch2 No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset (Between brown and black (orange) leads) Dark-ON Brown Load Black Control output 10 to 30 VDC Blue D lit. L lit. Display OUT1 indicator (orange) OUT2 indicator (orange) Brown Load Black Control output Load Orange ch1 Control output ch2 Pink Photoelectric sensor main circuit 10 to 30 VDC External input Blue D lit. Display OUT indicator (orange) 1 L lit. 4 Photoelectric sensor main circuit 3 D lit. * M8 Connector Pin Arrangement 2 1 L lit. Display OUT1 indicator (orange) OUT2 indicator (orange) Photoelectric sensor main circuit Brown Load Black Control output 10 to 30 VDC 2 E3NX-FA7TW Incident light ch1/ ch2 No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset (Between brown and black (orange) leads) Display OUT indicator (orange) Photoelectric sensor main circuit E3NX-FA21 Incident light ch1/ ch2 No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset (Between brown and black (orange) leads) Output circuit Orange Blue External input 4 3 Brown Load Black Control output Load Orange ch1 Control output ch2 10 to 30 VDC Blue D lit. 9 E3NX-FA PNP Output Operation mode Model Light-ON Timing chart Incident light No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset L/D indicator L lit. Output circuit Display OUT indicator (orange) (Between blue and black leads) E3NX-FA41 E3NX-FA8 Dark-ON Incident light No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset Brown Control Black output Photoelectric sensor main circuit 10 to 30 VDC Load Blue D lit. (Between blue and black leads) Light-ON ch1/ Incident light ch2 No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset L lit. Dark-ON Incident light ch1/ ch2 No incident light OUT indicator Lit Not lit (orange) ON Outputs OFF transistor Operate Load (e.g., relay) Reset Brown OUT1 indicator (orange) (Between blue and black (orange) leads) E3NX-FA51 OUT2 indicator (orange) Display External Pink input Control output Black ch1 Control output Orange ch2 Load Photoelectric sensor main circuit Blue 10 to 30 VDC Load D lit. (Between blue and black (orange) leads) Light-ON Incident light No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset Display OUT indicator (orange) 1 L lit. 2 Photoelectric sensor main circuit (Between blue and black leads) E3NX-FA9 E3NX-FA54 Dark-ON Incident light No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset 4 External Orange input Control Black output 10 to 30 VDC Load 3 D lit. Brown * M8 Connector Pin Arrangement 2 Blue 4 1 3 (Between blue and black leads) Light-ON ch1/ Incident light ch2 No incident light OUT indicator Lit Not lit (orange) ON Output OFF transistor Operate Load (e.g., relay) Reset OUT2 indicator (orange) Display 1 L lit. OUT1 indicator (orange) (Between blue and black (orange) leads) E3NX-FA9TW E3NX-FA54TW Dark-ON Incident light ch1/ ch2 No incident light OUT indicator Lit Not lit (orange) ON Outputs OFF transistor Operate Load (e.g., relay) Reset Control output Black ch1 Control output Orange ch2 Load 2 Photoelectric sensor main circuit 4 3 D lit. Brown * M8 Connector Pin Arrangement 2 1 Blue 10 to 30 VDC Load 4 3 (Between blue and black (orange) leads) Plug (Sensor I/O Connector) Terminal number 4 3 2 1 Wire color Brown White Blue Black 1 2 3 4 XS3F-M421-402-A XS3F-M421-405-A Wire color Connection pin Application Brown 1 Power supply (+V) White 2 External input / Output Blue 3 Power supply (0 V) Black 4 Output XS3F-M422-402-A XS3F-M422-405-A 10 E3NX-FA Nomenclature E3NX-FA11/FA41/FA6/FA8/FA7/FA9/FA24/FA54 [L/D Indicator] Indicates the setting status: Light-ON (L) or Dark-ON (D). [DPC Indicator] Turns ON when Dynamic Power Control is effective. [OUT Indicator] Turns ON when the output is ON. [ [ L/D Button] Use to switch between Light-ON (L) and Dark-ON (D). [ST Indicator] Turns ON when Smart Tuning is in progress. Threshold Level Incident Level White digital display Green digital display Tune Button] Executes Smart Tuning. [ MODE Button] Use to switch between Detection Mode and Setting Mode. [+ -UP/DOWN Button] Used to fine-tune the threshold or change set values. E3NX-FA21/FA51/FA7TW/FA9TW/FA54TW/FA0 [L/D Indicator] Indicates the setting status: Light-ON (L) or Dark-ON (D). [OUT1 Indicator/OUT2 Indicator] Turns ON when OUT1 or OUT2 is ON. [ Tune Button] Executes Smart Tuning. [DPC Indicator] Turns ON when Dynamic Power Control is effective. [ L/D Button] Use to switch between Light-ON (L) and Dark-ON (D). [ST Indicator] Turns ON when Smart Tuning is in progress. Threshold Level Green digital display Incident Level White digital display [OUT1 Selection Indicator/OUT2 Selection Indicator] The indicator for the selected output channel is lit. [ MODE Button] Use to switch between Detection Mode and Setting Mode, and use to switch between OUT1 and OUT2. [+ -UP/DOWN Button] Used to fine-tune the threshold or change set values. 11 E3NX-FA Safety Precautions To ensure safe operation, be sure to read and follow the Instruction Manual provided with the Sensor. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire. Never use the product with an AC power supply. Otherwise, explosion may result. Precautions for Safe Use The following precautions must be observed to ensure safe operation of the Amplifier Unit. Doing so may cause damage or fire. 1. Do not install the product in the following locations. * Locations subject to direct sunlight * Locations subject to condensation due to high humidity * Locations subject to corrosive gas * Locations subject to vibration or mechanical shocks exceeding the rated values * Locations subject to exposure to water, oil, chemicals * Locations subject to stream * Locations subjected to strong magnetic field or electric field 2. Do not use the product in environments subject to flammable or explosive gases. 3. Do not use the product in any atmosphere or environment that exceeds the ratings. 4. To secure the safety of operation and maintenance, do not install the product close to high-voltage devices and power devices. 5. High-voltage lines and power lines must be wired separately from the product. Wiring them together or placing them in the same duct may cause induction, resulting in malfunction or damage. 6. Do not apply any load exceeding the ratings. Otherwise, damage or fire may result. 7. Do not short the load. Otherwise, damage or fire may result. 8. Connect the load correctly. 9. Do not miswire such as the polarity of the power supply. 10.Do not use the product if the case is damaged. 11.Burn injury may occur. The product surface temperature rises depending on application conditions, such as the ambient temperature and the power supply voltage. Attention must be paid during operation or cleaning. 12.When setting the sensor, be sure to check safety such as by stopping the equipment. 13.Be sure to turn off the power supply before connecting or disconnecting wires. 14.Do not attempt to disassemble, repair, or modify the product in any way. 15.When disposing of the product, treat it as industrial waste. 16.Do not use the Sensor in water, rainfall, or outdoors. Precautions for Correct Use 1. Be sure to mount the unit to the DIN track until it clicks. 2. When using the Amplifier Units with Wire-saving Connectors, attach the protective stickers (provided with E3X-CN-series Connectors) on the unused power pins to prevent electrical shock and short circuiting. When using the Amplifier Units with Connectors for Communications Units, attach the protective caps (provided with E3NW-series Sensor Communications Unit). Amplifier Unit with Wiresaving Connector Amplifier Unit with Connector for Communications Unit Protective sticker Power supply connecting terminals Protective cap 3. Use an extension cable with a minimum thickness of 0.3 mm2 and less than 100 m long. 4. Do not apply the forces on the cord exceeding the following limits: Pull: 40N; torque: 0.1N*m; pressure: 20N; bending: 29.4N 5. Do not apply excessive force such as tension, compression or torsion to the Amplifier Unit with the Fiber Unit fixed to the Amplifier Unit. 6. Always keep the protective cover in place when using the Amplifier Unit. Not doing so may cause malfunction. 7. It may take time until the received light intensity and measured value become stable immediately after the power is turned on depending on use environment. 8. The product is ready to operate 200 ms after the power supply is turned ON. 9. The Mobile Console E3X-MC11, E3X-MC11-SV2 and E3X-MC11S cannot be connected. 10.The mutual interference prevention function does not work when in combination with E3C/E2C/E3X. 11.If the unit receives excessive sensor light, the mutual interference prevention function may not work properly, resulting in malfunction of the unit. In such case, increase the threshold. 12.Standard models and Advanced models The Sensor Communication Unit E3X-DRT21-S, E3X-CRT, E3XECT and E3NW cannot be connected. Model for Sensor Communication Unit (E3NX-FA0) The Sensor Communication Unit E3NW can be connected. E3X-DRT21-S, E3X-CRT, E3X-ECT cannot be connected. 13.If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke immediately stop using the product, turn off the power, and consult your dealer. 14.Do not use thinner, benzene, acetone, and lamp oil for cleaning. 12 E3NX-FA (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Fiber Amplifier Units Pre-wired Amplifier Units E3NX-FA11 E3NX-FA21 E3NX-FA41 E3NX-FA51 E3NX-FA21/FA51 E3NX-FA11/FA41 L/D indicator DPC indicator 21.7 ST indicator 21 27.1 *Cable Specifications L/D indicator DPC indicator ST indicator OUT2 selection indicator 27.8 OUT2 indicator Outer No. of Others Model diameter conductors E3NX-FA11 Conductor cross-section: 0.2 mm2 4.0 dia. 3 E3NX-FA41 Insulator dia.: 0.9 mm E3NX-FA21 Standard cable length: 2 m 4.0 dia. 5 E3NX-FA51 Minimum bending radius: 12 mm OUT1 indicator OUT1 selection indicator OUT indicator Incident level (white, digital) Threshold level (green, digital) Threshold level (green, digital) Incident level (white, digital) With Mounting Bracket Attached Mounted to DIN Track 10 5.1 5.1 147.1 (max. value with cover open) 71.8 170 (max. value with cover open) 104.8 (max. value with cover open) Two, 2.4-dia. fiber unit holes 4.5 33.5 33.5 (16.5) (37) 3.4 5.7 (37.9) 12.7 * 4.3 Optical communications 20.5 3.4 12.7 * Fiber Attachment (E39-F9) attached (16.5) (37) Two, 3.2 dia. (mounting holes) (20.3) Optical communications (9.4) 20.5 71.8 PFP-@N DIN Track (sold separately) 16 4.4 E39-L143 Mounting Bracket (sold separately, SUS304) 3.4 Mounting Holes Two, M3 holes (29.9) 16 Amplifier Units with Wire-saving Connectors E3NX-FA6 E3NX-FA7 E3NX-FA6/FA7/FA8/FA9 E3NX-FA7TW DPC indicator ST indicator E3NX-FA8 E3NX-FA9 L/D indicator 21.7 27.1 E3NX-FA9TW 16 E3NX-FA7TW/FA9TW L/D indicator OUT2 selection indicator DPC indicator 21 *Cable Specifications 27.8 Model Outer diameter E3X-CN12 2.6 dia. ST indicator OUT2 indicator No. of conductors 1 2 E3X-CN22 OUT1 indicator OUT indicator E3X-CN11 Threshold level (green, digital) Incident level (white, digital) Threshold level (green, digital) 4 With Mounting Bracket Attached 147.1 (max. value with cover open) 5.1 3 Incident level (white, digital) Mounted to DIN Track 10 4.0 dia. E3X-CN21 OUT1 selection indicator (75.3) 5.1 170 (max. value with cover open) 104.8 (max. value with cover open) 4.5 Two, 2.4-dia. fiber unit holes 33.5 33.5 (16.5) (16.5) (37) (37) 3.4 * 5.7 With Fiber Attachment (E39-F9) attached (13) * 4.3 Optical communications 20.5 (37.9) (23.8) (75.3) 3.4 Two, 3.2 dia. (mounting holes) Wire-saving Connector (sold separately) 20.5 PFP-@N DIN Track (sold separately) (9.4) 16 4.4 3.4 (13) Wire-saving Connect (sold separately) Optical communications E39-L143 Mounting Bracket (sold separately, SUS304) Mounting Holes Two, M3 holes (29.9) 16 16 13 E3NX-FA Amplifier Units with M8 Connectors E3NX-FA24 E3NX-FA54 E3NX-FA54TW E3NX-FA24/FA54 L/D indicator E3NX-FA54TW ST indicator DPC indicator OUT2 selection indicator 21.7 27.1 21 27.8 OUT2 indicator 4.2 6.9 5.2 OUT indicator Threshold level (green, digital) ST indicator Incident level (white, digital) OUT1 selection indicator Threshold level (green, digital) 147.1 (max. value with cover open) 5.1 Two, 2.4-dia. fiber unit holes 4.5 1 3 71.8 170 (max. value with cover open) 104.8 (max. value with cover open) 4 With Mounting Bracket Attached Mounted to DIN Track 5.1 2 OUT1 indicator Incident level (white, digital) 10 Connector pin arrangement L/D indicator DPC indicator 33.5 (16.5) (5.7) 3.4 37 4.9 12.7 3.4 5.7 4.8 20.5 20.5 M8 Connector 37.9 20.3 Two, 3.2 dia. (mounting holes) 71.8 (9.4) 4.3 16 37.9 20.5 E39-L143 Mounting Bracket (sold separately, SUS304) PFP-@N DIN Track (sold separately) Optical communications 4.4 3.4 Mounting Holes Two, M3 holes 29.9 16 16 Amplifier Unit with Connector for Sensor Communications Unit E3NX-FA0 OUT2 selection indicator L/D indicator DPC indicator ST indicator OUT2 indicator 21 27.8 OUT1 indicator OUT1 selection indicator Incident level (white, digital) Threshold level (green, digital) 13.8 Mounted to DIN Track 11.5 10 5.1 140 (max. value with cover open) 152 (max. value with cover open) 104.8 (max. value with cover open) 4.5 Two, 2.4-dia. fiber unit holes 33.5 (37) (16.5) 26 (29.9) 3.4 5.7 With Fiber Attachment (E39-F9) attached Optical communications 20.5 (39.3) (37.9) 90.8 PFP-@N DIN Track (sold separately) 14 E3NX-FA Accessories (Sold Separately) Wire-saving Connectors Master Connector E3X-CN11 Edge of Amplifier Unit E3X-CN21 2,000+500 (7) * * E3X-CN11: 4-dia. cable with 3 conductors, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm) E3X-CN21: 4-dia. cable with 4 conductors, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm) Slave Connector E3X-CN12 Edge of Amplifier Unit E3X-CN22 2,000+50 0 (7) * * E3X-CN12: 2.6-dia. cable with 1 conductor, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm) E3X-CN22: 4-dia. cable with 2 conductors, Standard cable length: 2 m (Conductor cross-section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm) Sensor I/O Connectors Straight XS3F-M421-40@-A 2.15 M8 4 2 3 1 12.9 4 dia. 9 dia. 1.95 0.5 21.5 3.4 30 5 50 31.4 L L-shaped XS3F-M422-40@-A 50 L 23.1 20.5 30 5 4 dia. 9 dia. 3.4 2.15 0.5 1.95 15 E3NX-FA Mounting Bracket E39-L143 34.8 22 16 2.5 (10.3) 3 Mounting Holes 7.3 5.3 Two, M3 holes 26.8 3.2 -dia. holes 3 16 7 160.1 3 Four, Radius: 1.7 10.3 10 max. 7 3.4 Material: Stainless steel (SUS304) 1 3.4 1 DIN Track PFP-100N PFP-50N 7.30.15 4.5 350.3 15 25 10 25 25 1,000 (500)* 25 10 270.15 15 (5)* 1 *Dimensions in parentheses are for the PFP-50N. Material: Aluminum PFP-100N2 16 4.5 350.3 27 15 25 25 10 25 1,000 10 25 15 24 29.2 1 1.5 Material: Aluminum End Plate PFP-M 11.5 50 M4x8 panhead screw 10 M4 spring washer 4.8 6.2 10 1 1.3 1.8 35.5 Materials: Iron, zinc plating 1.8 35.3 16 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2014.7 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2014 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: E3NX-FA24 E3NX-FA54TW E3NX-FA54 E3NX-FA11 2M E3NX-FA21 2M E3NX-FA41 2M E3NX-FA51 2M E3NXFA6 E3NX-FA7 E3NX-FA7TW E3NX-FA8 E3NX-FA9 E3NX-FA9TW