DC/DC Converter
REGULATIONS
Parameter Condition Values
Output Voltage Accuracy 100% load, Vin nominal ±5% max.
Line Voltage Regulation low line to high line, full load ±1.2% typ. / 1% Vin
Load Voltage Regulation 20% to 100% load, 5Vout
20% to 100% load, 12Vout and 15Vout
15% max.
10% max.
ECO-2 REV.: 0/2015 www.recom-power.com
PROTECTIONS
Parameter Condition Value
Isolation Voltage I/P to O/P 1kVDC / 1 second
Isolation Capacitance 75pF max.
Isolation Resistance 1GΩ min.
ROE
Series
Specifications (measured at TA= 25°C, nominal input voltage, full load and after warm up unless otherwise specified)
Vin= 3.3V, 5V Vin= 12V, 15V, 24V
Tolerance Envelope
10
-5%
-2%
+5%
+15%
Typical Load Line
+4%
Vnom
50 100
Output Voltage
+Vout and -Vout Load Current (%)
10
-5%
-1%
+5%
+15%
Typical Load Line
+5%
Vnom
50 100
Output Voltage
+Vout and -Vout Load Current (%)
ENVIRONMENTAL
Parameter Condition
Operating Temperature Range free air convection (see graph) -40°C to +85°C
Operating Humidity non-condensing 95% RH max.
Vibration MIL-STD-202G
MTBF (+25°C)
(+85°C) according to MIL-HDBK-217F, full load 22380 x 103 hours
9300 x 103 hours
100
80
60
40
20
0
-40 0 50 85 100 150
Output Power (%)
Ambient Temperature (°C)
Safe Operating Area
Derating Graph