MIT515, MIT525, MIT1025, MIT1525 5, 10 & 15 kV DC Insulation Resistance Testers MIT515, MIT525, MIT1025, MIT1525 5, 10 & 15 kV DC Insulation Resistance Testers DESCRIPTION The new range of insulation resistance testers (IRTs) are smaller and lighter than previous models yet offer advanced features and rapid charge capability. The range consists of four models; an entry level 5 kV and three fully featured units, one 5 kV one 10 kV and a 15kV. Resistance measurement up to 10 T for the 5 kV models, 20 T for the 10 kV model and 40 T for the 15 kV model. A key productivity feature is the ability to take measurements when connected to line power/mains with a dead battery. Intelligent battery charging ensures the optimum charge rate as a function of battery level, resulting in minimum charge times. The rugged case provides ultimate protection for a portable instrument and a clip-on lead pouch ensures that leads remain with the instrument at all times. The case lid is removable for improved terminal access. IP rating is IP65 with the case closed preventing water/dust ingress. High reliability and safety are built in; all models are safety rated to CATIV 600 V and are double insulated. Five preset voltage ranges are provided in insulation test mode, plus a user settable lock voltage range. Preconfigured diagnostic tests include Polarisation Index (PI), Dielectric Absorption Ratio (DAR), dielectric discharge (DD), Stepped Voltage (SV) and ramp test. Simplicity of operation is achieved with two rotary switches and the large backlight display enables multiple results to be displayed simultaneously. Advanced memory storage includes time/date stamping of results, logging of data and recall of results to screen. A fully isolated USB device interface (type B) is used for safe transfer of data to Megger's PowerDB / Pro, Advanced and Lite asset management software. Measures up to 40 T PI, DAR, DD, SV and ramp test Improved productivity - operate from line power/mains if battery dead Li ion battery - extended capacity, rapid charge Advanced memory with time/date stamp CATIV 600 V safety rating FEATURES AND BENEFITS 10 T (5 kV) / 20 T (10 kV) / 40 T (15 kV) max. insulation resistance Timed IR plus PI and DAR diagnostic tests Operate with dead battery when on line power/mains Rapid charge Li-ion battery - up to 6 hrs continuous testing (5 kV) Dedicated voltmeter function (30 V to 660 V) CATIV 600 V safety rating Large LCD display with automatic backlight Noise filter - rejects up to 3 mA noise High altitude operation up to 3000 m MIT525/1025 ADDITIONAL FEATURES Dielectric Discharge (DD), Step Voltage (SV) and ramp test functions Advanced memory with time/date stamp, on screen recall Real time clock Download of memory via isolated USB (type B) interface (USB cable to PC) PowerDB Lite asset management software APPLICATION The Insulation Resistance (IR) test is a quantitative test which indicates the effectiveness of a product's electrical insulation. Applications include cables, transformers, motors/generators, circuit breakers and bushings. Common insulation tests are the MIT515, MIT525, MIT1025, MIT1525 5, 10 & 15 kV DC Insulation Resistance Testers "spot test", a 1 minute IR test and a 10 minute Polarisation Index (PI) test, where PI is the ratio R10min/R1min and temperature independent. ELECTRICAL SPECIFICATIONS Voltage input range: Battery: 85-265 V rms, 50/60 Hz, 60 VA 11.1 V, 5.2 A hour, meets IEC 62133:2003 Battery life MIT515, MIT525: Typical capacity 6 hours continuous at 5 kV with a 100 M load Typical capacity 4.5 hours continuous at 10 kV with a 100 M load 2.5 hours from deep discharge, 2 hours normal discharge Typical capacity 6 hours continuous at 15 kV with a 100 M load 1 hour operation at 5 kV, 100 M MIT1025: Battery charge time: MIT1525: 30 min. quick charge: Test voltages MIT515, MIT525: 250 V, 500 V, 1000 V, 2500 V, 5000 V 500 V, 1000 V, 2500 V, 5000 V, 10000 V MIT1025: User defined test voltage: MIT515, MIT525 100 V to 1 kV in 10 V steps, 1 kV to 5 kV in 25 V steps, MIT1525: 1000 V, 2500 V, 5000 V, 10000 V, 15000 V MIT1025 5 kV to 10 kV in 25 V steps MIT1525 10 kV to 15 kV in 25 V steps Accuracy (23 C): 5000 V 1 T 10 T 2500 V 500 G 5 T 1000 V 200 G 2 T 500 V 100 G 1 T Capacitance range (above 500 V): Capacitance accuracy (23 C): Voltage output accuracy Current measurement range: Current measurement accuracy (23 C): Interference (noise) rejection: MIT515, MIT525 MIT1025 MIT1525 Voltmeter range: Voltmeter accuracy: Timer range: Memory capacity: < xxx ms/uF to discharge from 15000 V to 50 V 10 nF to 25 F (dependant on measurement voltage) 10% 5 nF +4%, -0%, 10 V nominal test voltage (>200 V, 0 C to 30 C): at 1 G 0.01 nA to 6 mA 5% 0.2 nA at all voltages 1 mA per 250 V up to a maximum of 3 mA 1 mA per 600 V up a maximum of 3 mA 4 mA 30 V to 660 V ac or dc, 50/60 Hz 3%, 3 V Up to 99 minutes, 15 second minimum setting 51/2 hours continuous logging every 5 s. or 33 logged PI tests or 350 logged IR tests MIT1525 11 hours continuous logging every 5 s. Test regimes: MIT515 MIT525, MIT1025 Interface: Real time output: MIT515, MIT525 accuracy (23 C) 5% to 20% to MIT1525 250 V 50 G 500 G MIT1025 accuracy (23 C) 15 kV 10 k V 2500 V 5000 V 1000 V 5% to 3 T 2 T 1 T 500 G 200 G 20% to Guard : 40 T 20 T IR, IR(t), DAR, PI IR, IR(t), DAR, PI, SV, DD, ramp test USB type B (device) USB, 1 reading/second (voltage, current and resistance) ENVIROMENTAL CONDITIONS Altitude: 3000 m, CAT rating maintained >2000 m* * Test leads connected 4000 m (MIT1525 only) Operating temperature Storage temperature: Humidity: Ingress protection: -20 C to 50 C -25 C to 65 C 90% RH non-condensing at 40 C IP65 (lid closed), IP40 (lid open) 10 T 2 T 1 T 2% error guarding 500 k leakage with 100 M load 100 k to 10 T GENERAL SPECIFICATION Safety: Meets the requirements of IEC 61010-1, CATIV 600 V Dimensions MIT515, MIT525, MIT1025: Insulation alarm: 10 k to 10 T 10 k to 20 T 3 mA nominal, max. power on all loads outperforming many 5 mA testers 100 k to 1 G Capacitor charge: MIT515, MIT525 MIT1025 MIT1525 <3 s/F at 3 mA to 5 kV <5 s/F at 3 mA to 10 kV < x s/uF at 3 mA to 15 kV Display range analogue: Display range digital: MIT515, MIT525 MIT1025 Short circuit current: Capacitor discharge: MIT515, MIT525 MIT1025 <250 ms/F to discharge from 5000 V to 50 V <500 ms/F to discharge from 10000 V to 50 V EMC: Meets the requirements of IEC61326-1 MIT1525: L 315 mm x W 285 mm x H 181 mm Weight: 4.5 kg 360 mm x W 305 mm x H 194 mm Weight: 6.5 kg MIT515, MIT525, MIT1025, MIT1525 5, 10 & 15 kV DC Insulation Resistance Testers TEST LEADS SUPPLIED and clips, should never be touched during the test. The system must be safely discharged before touching connections. The MIT515. MIT525 and the MIT1025 are all supplied with test leads that are compliant with the requirements of IEC61010-031:2008. The 5 kV models are supplied with one 3m lead-set with medium sized clips. The 10 kV models are supplied with two 3m lead-sets, one with medium sized clips and the other with large clips with insulation suited to 10 kV use. DESIGNED FOR EVERYDAY USE Test leads are a key component of any precision instrument and that safety, long life, and the ability to provide reliable connections to a variety of test pieces found in everyday applications are of the utmost importance. Megger design test leads for both safety and practical operation. These leads are designed based on Megger's extensive knowledge of insulation testing using the latest technology. The leads are in compliance with IEC61010-31:2008 which requires a fully insulated clip design. LOCKING HV INSULATED PLUGS/NON-REMOVABLE TEST CLIPS All Megger 5 kV an 10 kV insulation testing test leads are fitted with unique locking HV plugs and non-removable test clips. This reduces the likelihood of a plug or clip inadvertently losing electrical connection and the capacitance of a long cable remaining lethally charged. MEDIUM INSULATED TEST CLIP 3 M X 3 LEADSET These test leads are supplied as standard on MIT515, MIT525 and the MIT1025. These clips are designed for clamping on larger diameter test pieces but where space is at a premium. The insulation is designed only to protect the user from the output of Megger 5 kV and 10 kV (set below 6 kV) insulation resistance testers. The clips cannot in any circumstance be relied on to protect the user from live ac systems above 600 V a.c., r.m.s. in an CATIV environment. Cable insulation rating: 12 kV dc (marked on cable) With the arrows on the plug finger guard horizontal on the instrument as shown to lock. Twist 90 to to unlock. In addition, for the same reason, the test clips are not removable from the test lead. Cable type: flexible dual insulated silicon (inner insulation layer coloured white to highlight damage PRACTICAL INSULATION DESIGN LARGE INSULATED TEST CLIP 3 m X 3 LEADSET These test leads are supplied as standard on MIT1025. These clips are designed for clamping on larger diameter test pieces. The insulation is designed only to protect the user from the output of Megger 5 kV and 10 kV insulation resistance testers. The clips cannot in any circumstance be relied on to protect the user from live ac systems above 600 V a.c., r.m.s. in an CATIV environment. Moving jaw fingers maintain the clips touch proof safety when clip is closed but flex back to allow metal teeth of the clip to contact test piece unimpeded when in use. Cable insulation rating: 12 kV dc (marked on cable) Cable type: flexible dual insulated silicon (inner insulation layer coloured white to highlight damage) The design of the lead sets is intended to facilitate connection to a variety of de-energized systems for the purpose of making insulation resistance measurements. In all cases it is the responsibility of the user to employ safe working practices and verify that the system is safe before connection. Even isolated systems may exhibit significant capacitance which will become highly charged during the application of the insulation test. This charge can be lethal and connections, including the leads Megger clip being tested with IEC standard test finger for creepage and clearance. MIT515, MIT525, MIT1025, MIT1525 5, 10 & 15 kV DC Insulation Resistance Testers PRACTICAL JAW DESIGN Cable insulation rating: 5 kV or 10 kV dc Cable type: flexible screened PVC Note: Screened test leads are an important accessory for those working in high noise environments, and/or locations where test lead leakage could be a problem. Curved jaws allow reliable connection around test pieces and flat jaw tips provide excellent connection and gripping of individual wires. CONTROL CIRCUIT TEST LEAD SETS OPTIONAL TEST LEADS The insulation is designed only to protect the user from the output of Megger 5 kV and 10 kV insulation resistance testers set to a maximum output voltage of 1 kV. Do not use this leadset at voltages above 1 kV. MEDIUM AND LARGE TEST CLIPS Test leads above with medium and large size insulated clips are available supplied as an option in 5m, 8m, 10m and 15m lengths. These are listed in the ordering information panel at the end of this data sheet. These test leads may also be supplied in non-standard lengths to suit a particular application / requirement. Please contact Megger for a quotation, minimum order quantities may apply. This probe and clip leadset is designed for testing low voltage circuits with test voltages up to 1 kV. Cable insulation rating: 1 kV dc COMPACT TEST CLIP LEADS These clips are designed for clamping on test pieces where access is limited. There is no insulation on these clips. FUSED TEST PROBE AND CLIP LEAD SET This fused probe and clip leadset is designed for testing low voltage circuits with test voltages up to 1 kV. The leadset is GS38 compliant, fitted with FF500mA 50 kA fuses, which allows voltage measurements to be made in safety when using the user selectable voltage measuring range on the MIT515, MIT525 and MIT1025 instruments. Extreme care must be taken to avoid electric shock when connecting/disconnecting due to the bare metallic clips. Cable insulation rating: 12 kV dc (marked on cable) Cable type: flexible dual insulated silicon (inner insulation layer coloured white to highlight damage) The insulation is designed only to protect the user from the output of Megger 5 kV and 10 kV insulation resistance testers set to a maximum output voltage of 1 kV. Do not use this leadset at voltages above 1 kV. Cable insulation rating: 1 kV COMPACT TEST CLIP WITH 5 OR 10 kV SCREENED CABLE The clips are designed for clamping on test pieces where access is limited. There is no insulation on these clips. Extreme care must be taken to avoid electric shock when connecting/ disconnecting due to the bare metallic clips. The screened test lead set consists of: A black/negative test lead that has been screened. A red/positive test lead that is not screened. More detailed information can be found on the 5 kV and 10 kV insulation tester lead sets application note. This document can be downloaded from: www.megger.com MIT515, MIT525, MIT1025, MIT1525 5, 10 & 15 kV DC Insulation Resistance Testers ORDERING INFORMATION Item (Qty) Cat. No. Item (Qty) MIT515-UK 1001-935 MIT515-US 1001-936 Optional Accessories HV test leads MIT515-EU 1001-937 5 m leadset x 3, large insulated clips* 1002-645 8 m leadset x 3, large insulated clips 1002-646 10 m leadset x 3, large insulated clips 1002-647 15 m leadset x 3, large insulated clips 1002-648 5 m leadset x 3, medium insulated clips* 1002-641 8 m leadset x 3, medium insulated clips 1002-642 10 m leadset x 3, medium insulated clips 1002-643 15 m leadset x 3, medium insulated clips 1002-644 MIT515-AU 1001-938 MIT525-UK 1001-939 MIT525-US 1001-940 MIT525-EU 1001-941 MIT525-AU 1001-942 MIT1025-UK 1001-943 MIT1025-US 1001-944 MIT1025-EU 1001-945 MIT1025-AU 1001-946 MIT1525-? Cat. No. *These test leads may also be supplied in non-standard lengths to suit a particular application / requirement. Please contact Megger for a quotation, minimum order quantities may apply. MIT1525-? MIT1525-? Included Accessories 3 m leadset x 3, bare compact clips 8101-181 8 m leadset x 3, bare compact clips 8101-182 15 m leadset x 3, compact bare clips 8101-183 User guide CD Screened HV test lead sets Power lead 3 m, 5 kV screened un-insulated small clips 6220-835 3 m leadset x 3, large insulated clips (MIT1025 only) 1002-534 15 m, 5 kV screened un-insulated small clips 6311-080 Included Accessories (MIT525, MIT1025) 3 m, 10 kV screened un-insulated small clips 6220-834 USB cable 10 m, 10 kV screened un-insulated small clips 6220-861 PowerDB Lite software 15 m, 10 kV screened un-insulated small clips 6220-833 Optional Accessories 1 kV test lead sets Other 3 m leadset x 3, medium insulated clips 1002-531 25970-041 CB101, 5 kV calibration box 6311-077 Fused test probe and clip lead set 1002-913 Calibration certificate - CB101 1000-113 Control circuit test lead set 6220-822 UKAS calibration certificate CB101 1000-047 UK Archcliffe Road Dover CT17 9EN England T +44 (0) 1304 502101 F +44 (0) 1304 207342 UKsales@megger.com UNITED STATES 4271 Bronze Way Dallas TX 75237-1019 USA T 800 723 2861 (USA only) T +1 214 333 3201 F +1 214 331 7399 USsales@megger.com OTHER TECHNICAL SALES OFFICES Valley Forge USA, College Station USA, Sydney AUSTRALIA, Taby SWEDEN, Ontario CANADA, Trappes FRANCE, Oberursel GERMANY, Aargau SWITZERLAND, Dubai UEA, Mumbai INDIA, Durban SOUTH AFRICA, Chonburi THAILAND, Malaga SPAIN CERTIFICATION ISO Registered to ISO 9001:2008 Cert. no. Q 09250 Registered to ISO 14001-2004 Cert. no. EMS 61597 MIT515_525_1025_DS_en_V05 www.megger.com Megger is a registered trademark