DC Axial Fans Series 4100 N, Type 4182 NGX 119 x 119 x 38 mm - DC fans with electronically commutated external rotor motor. Fully integrated commutation electronics. - With electronic protection against reverse polarity, blocking and overloading by PTC-resistor; partially impedance protected. - Metal fan housing. Impeller of fibre-glass reinforced plastic PA. Housing with ground lug M4 for M4 x 8 screws. - Air intake over struts. Rotational direction CW looking at rotor. - Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. - Electrical connection via 2 flat pins 2,8 x 0,5 mm. - Mass 390 g. / Watt min-1 C Hours Hours Curve Bel at t max dB(A) Service Life L10 at 40 C V DC Temperature Range V DC Nominal Speed Noise CFM Power Input Voltage Range m3/h Sintec-Sleeve Bearings Ball Bearings Nominal Voltage Type Air Flow Nominal Data Air Flow ebm-papst * St. Georgen 4182 NGX 160 94.2 12 7...15 44 5.3 3.5 2 800 -10...+75 85 000 / 37 500 4182 NX 180 105.9 12 7...15 49 5.7 4.5 3 200 -30...+75 85 000 / 37 500 2 4182 NXH 237 139.5 12 7...14 59 6.5 4 400 -30...+55 70 000 / 50 000 2 1 11 1 4184 NGX 160 94.2 24 12...30 44 5.3 3.5 2 800 -10...+75 85 000 / 37 500 4184 NX 180 105.9 24 12...29 49 5.7 4.5 3 200 -30...+75 85 000 / 37 500 2 4184 NXH 237 139.5 24 12...25 59 6.5 11 4 400 -30...+55 70 000 / 50 000 3 4184 NXHH 250 147.1 24 12...25 60 6.7 12.2 4 900 -30...+55 70 000 / 52 500 4 4188 NXM 160 94.2 48 36...56 44 5.3 3.5 2 800 -30...+75 85 000 / 37 500 1 Programmable fan Vario-Pro (electr. connection via leads) 4112 NHH 270 158.9 12 11...13 64 7.0 15.5 5 000 -20...+50 70 000 / 55 000 5 4114 NHH 270 158.9 24 18...26.4 64 7.0 15.5 5 000 -20...+60 70 000 / 52 500 5 4118 NHH 270 158.9 48 44...52 64 7.0 15.5 5 000 -10...+55 70 000 / 52 500 5 ebm-papst St. Georgen GmbH & Co. KG Hermann-Papst-Strae 1 * D-78112 St. Georgen * Phone +49 (0) 77 24 / 81-0 * Fax +49 (0) 77 24 / 81-1309 * info2@de.ebmpapst.com * www.ebmpapst.com/de Sensor signal /2 - - - - - - - Speed-proportional rectangular pulse for external speed monitoring of fan motor 2 pulses per revolution Open-Collector signal output Extremely wide operating voltage range (5 ... 60 V) Easy adaptation to user interface Connection via separate lead The sensor signal also serves as a major comparison variable for setting and maintaining the desired speed for interactive or controlled cooling with one or several interconnected fans. Sensor signal US Low Condition: Isink Sensor signal US High Condition: Isource Sensor operating voltage UBS Perm. sink current Isink max. ebm-papst * St. Georgen Type V DC mA V DC mA V DC mA 255 N/2 255 H/2 252 N/2 0.4 0.4 0.4 2 2 2 30 30 30 0 0 0 30 30 30 2 2 2 405 F/2 405 F/2 H 412 F/2 H 414 F/2 405 /2 412 /2 414 /2 414 /2 H 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 1 1 1 1 1 1 1 1 30 30 30 30 30 30 30 30 0 0 0 0 0 0 0 0 30 30 30 30 30 30 30 30 2 2 2 2 2 2 2 2 412 J/2 H 412 J/2 HH 414 J/2 H 414 J/2 HH 0.4 0.4 0.4 0.4 1 1 2 2 30 30 30 30 0 0 0 0 30 30 30 30 4 4 4 4 512 F/2 514 F/2 0.4 0.4 1 1 30 30 0 0 30 30 2 2 612 F/2 612 F/2 H 614 F/2 612 N/2 H 612 N/2 NHH-120 612 N/2 N 614 N/2 H 614 N/2 HH-121 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 1 1 1 1 1 1 1 1 30 30 30 30 30 30 30 30 0 0 0 0 0 0 0 0 30 30 30 30 30 30 30 30 2 2 2 2 2 2 2 2 614 N/2 M 0.4 2 28 0 30 4 712 F/2 L 712 F/2 M 0.4 0.4 1 1 30 30 0 0 30 30 2 2 8412 N/2 GL 8412 N/2 GM 8412 N/2 G 8414 N/2 GL 8414 N/2 GM 8414 N/2 G 8414 N/2 8412 N/2 8412 N/2 H 8414 N/2 H 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 2 2 2 2 2 2 2 2 2 2 28 28 28 28 28 28 28 28 28 28 0 0 0 0 0 0 0 0 0 0 28 28 28 28 28 28 28 28 28 28 4 4 4 4 4 4 4 4 4 4 8312 /2 HL 8314 /2 8314 /2 H 0.4 0.4 0.4 2 2 2 30 30 30 0 0 0 30 30 30 4 4 4 Electrical connection All voltages measured to ground. External load resistance Ra from US to UBS required. Signal symmetry [t1, t2] = 0.8 ... 1.2 Signal frequency [F] = 2 x n/60 Hz Attention: With these fan options, deviations in regard to temperature range, voltage range and power consumption are possible compared with standard fan data. Signal data ebm-papst St. Georgen GmbH & Co. KG Hermann-Papst-Strae 1 * D-78112 St. Georgen * Phone +49 (0) 77 24 / 81-0 * Fax +49 (0) 77 24 / 81-1309 * info2@de.ebmpapst.com * www.ebmpapst.com/de Condition: Isource Sensor operating voltage UBS Perm. sink current Isink max. Sensor signal US Low Condition: Isink Condition: Isource Sensor operating voltage UBS Perm. sink current Isink max. V DC mA V DC mA V DC mA Type V DC mA V DC mA V DC mA 0.4 0.4 0.4 2 2 2 30 30 30 0 0 0 30 30 30 4 4 4 4214 /2 H 4218 /2 4218 /2 H 0.4 0.4 0.4 2 2 2 30 30 30 0 0 0 4-30 4-30 4-30 4 4 4 3412 N/2 GL 3412 N/2 GM 3412 N/2 3412 N/2 G 3412 N/2 HH 3412 N/2 GHH 3412 N/2 H 3414 N/2 GH 3414 N/2 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 2 2 2 2 2 2 2 2 2 28 28 28 28 28 28 28 28 28 0 0 0 0 0 0 0 0 0 28 28 28 28 28 28 28 28 28 4 4 4 4 4 4 4 4 4 4182 N/2 X 4182 N/2 GX 4184 N/2 GX 4184 N/2 X 4184 N/2 XH 0.4 0.4 0.4 0.4 0.4 2 2 2 2 2 30 30 30 30 30 0 0 0 0 0 4-30 4-30 4-30 4-30 4-30 4 4 4 4 4 5112 N/2 5114 N/2 5118 N/2 0.4 0.4 0.4 2 2 2 15 60 60 0 0 0 5 60 60 20 20 20 3312 /2 3318 /2 0.4 0.4 2 2 30 30 0 0 30 30 4 4 4412 F/2 GL 4412 F/2 GML 4412 F/2 M 4412 F/2 4414 F/2 L 4414 F/2 M 4414 F/2 G 4414 F/2 4418 F/2 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 2 2 2 2 2 2 2 2 2 30 30 30 30 30 30 30 30 30 0 0 0 0 0 0 0 0 0 30 30 30 30 30 30 30 30 30 4 4 4 4 4 4 4 4 4 5212 N/2 H 5212 N/2 N 5214 N/2 N 5218 N/2 H 0.4 0.4 0.4 0.4 2 2 2 2 30 30 30 30 0 0 0 0 4-30 4-30 4-30 4-30 2 2 2 2 7112 N/2 7114 N/2 7118 N/2 0.4 0.4 0.4 2 2 2 60 30 60 0 0 0 60 30 60 20 20 20 6224 N/2 6248 N/2 0.4 0.4 8 8 30 60 0 0 30 30 20 20 DV 6224 /2 6424 /2 0.4 0.4 2 2 30 60 0 0 60 60 20 20 4312 N/2 H 4312 N/2 HH 0.4 0.4 2 2 30 30 0 0 30 30 4 4 4312 /2 4314 /2 G 4314 /2 4318 /2 G 4318 /2 M 4318 /2 0.4 0.4 0.4 0.4 0.4 0.4 2 2 2 2 2 2 30 30 30 30 30 30 0 0 0 0 0 0 30 30 30 30 30 30 4 4 4 4 4 4 6448 /2 6448 /2 T RL 48-19/12/2 RL 48-19/14/2 0.4 0.4 0.4 0.4 2 2 2 2 60 60 28 28 0 0 0 0 60 60 4-30 4-30 20 20 4 4 RL 90-18/12N/2 RL 90-18/14N/2 0.4 0.4 2 2 30 30 0 0 30 30 4 4 RG 90-18/12N/2 RG 90-18/14N/2 0.4 0.4 2 2 30 30 0 0 30 30 4 4 4212 N/2 GN 4212 N/2 H 4214 N/2 GN 4214 N/2 H 4218 N/2 GN 4218 N/2 H 0.4 0.4 0.4 0.4 0.4 0.4 2 2 2 2 2 2 30 30 30 30 30 30 0 0 0 0 0 0 30 30 30 30 30 30 4 4 4 4 4 4 RG 125-19/14N/2 RG 125-19/18N/2 RER 125-19/14N/2 0.4 0.4 0.4 2 2 2 30 60 30 0 0 0 30 30 30 4 4 4 RG 160-28/14N/2 0.4 2 30 0 30 20 4212 /2 M 4212 /2 4212 /2 H 4214 /2 0.4 0.4 0.4 0.4 2 2 2 2 30 30 30 30 0 0 0 0 30 30 30 4-30 4 4 4 4 Signal data Sensor signal US High Condition: Isink Type 8318 /2 8318 /2 HL 8318 /2 H Signal data Sensor signal US High Sensor signal US Low Available on request: - Galvanically separated sensor signal circuit - Varying voltage potentials for power and logic circuit. Attention: With these fan options, deviations in regard to temperature range, voltage range and power consumption are possible compared with standard fan data. ebm-papst St. Georgen GmbH & Co. KG Hermann-Papst-Strae 1 * D-78112 St. Georgen * Phone +49 (0) 77 24 / 81-0 * Fax +49 (0) 77 24 / 81-1309 * info2@de.ebmpapst.com * www.ebmpapst.com/de