1power.pulseelectronics.com P724.B (03/18) http://www.power.pulseelectronics.com/contact
Switch Mode Transformer for
AC/DC ofine Applications
EE16H, EE16V, EF20H and EF25V Platforms
PH0270NL
Pri. Inductance (3-1) 876 µH±10%
FLYBACK TRANSFORMER
Lk. Inductance w/ (3-1)
(4,5,6,7,9,10) 28µH max shorted
DCR
(3-1)
(4-5)
(9-10)
0.5
ΩMax
0.026
0.025
Hi-Pot Pri-Sec 1500 Vrms
K1 Factor 2900
PI IC’s TOP244/245/246/254/264
Notes:
1. The temperature of the component (ambient plus temperature rise)
must be within the stated operating temperature range.
2. The above transformers and inductors have been tested and approved
by Pulse’s power IC partners and are sited in the appropriate datasheet or
evaluation board documentation at these companies. To determine which
IC and IC partners are matched with the above Pulse part numbers please
consult the IC Cross Reference on the Pulse website.
3. For flyback topology applications, it is necessary to ensure that the
transformer will not saturate in the application. The peak flux density (Bpk)
should remain below 2700Gauss. To calculate the peak density, use the
following formula: Bpk (Gauss) = K1_Factor * Ipk (A)
4. In high volt-sec applications, it is important to calculate the core loss of the
transformer. Approximate transformer core loss can be calculated as:
CoreLoss (W) = 3.6E-14 * (Freq_kHz) * (ΔB_Gauss) where ΔB can be calculated as:
For Flyback Topology: ΔB = K1_Factor * Δ(A)
For Forward Topology: ΔB = K1_Factor * Volt-µsec
5. The “NL” sux indicates an RoHS-compliant part number. Non-NL suxed
parts are not necessarily RoHS compliant, but are electrically and mechanically
equivalent to NL versions. If a part number does not have the “NL” sux, but an
RoHS compliant version is required, please contact Pulse for availability.
PH0256NL
Mechanical
9
6
3
5
4
7
PH0256NL
Mechanical
12Vdc, 2.5A
85V-265V
132KHz
12Vdc, 0.02A