Telecom-, Signal and RF Relays
AXICOM
Cradle Relay N V23154 / V23162
108-98012 • Nov. 07 • Rev. C • ECOC: JM10
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 2 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
Index
Dimensions 4
Coil Data and operating range 6
Relay Code 7
Coil Data and Ordering Information 9
Instructions for Impulse Operation 17
Nomograph for Determining Factor q 18
Contact Data 19
Insulation / General Data 21
Disclaimer
While Tyco Electronics has made every reasonable effort
to ensure the accuracy of the information in this datasheet,
Tyco Electronics does not guarantee that it is error-free,
nor does Tyco Electronics make any other representati-
on, warranty or guarantee that the information is accurate,
correct, reliable or current. Tyco Electronics reserves the
right to make any adjustments to the information contai-
ned herein at any time without notice. Tyco Electronics
expressly disclaims all implied warranties (and all express
warranties, except as otherwise stated in this datasheet)
regarding the information contained herein, including but
not limited to any implied warranties or merchantability or
tness for a particular purpose. It is recommended that
you test any new or replacement product before incorpo-
rating into a system.
The dimensions in this datasheet are for reference purpo-
se only and are subject to change without notice. Speci-
cations are subject to change without notice.
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 3 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
PCB, hand solder or plug-in relays,
for DC operation,
non-polarized, non-latching
ROHS compliant (Directive 2002/95/EC) as per
product date code 0501.
Features
Multi purpose relay
highly reliable
great variety of contact arrangements and
materials to meet specic applications
Contacts for signal loads and currents up to 5 A
AC and DC, latching and non-latching,
coils operating voltage 1.5 V ... 125 V
Sockets for easy and quick mounting of relays
(see data sheet Accessories)
Typical applications
Measurement and control equipment
Press controls with high safety requirements
(forcibly guided springs)
Telecommunications
Relay types
Size I or II, depending on contact set
Standard contact sets with max. 4 changeover,
2 break or 6 make contacts, special
congurations on request
Single or bifurcated contacts
Hand solder terminals also for plug-in
connection with screw xing or PCB terminals
Dust-protected with plastic cover, V23154 - xxx
hermetically sealed with metal enclosure, V23162 - xxx
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 4 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
Dimensions Dimensions in mm
Type V23154-MXX Size I Type V23154-NXX Size II
For printed circuit mounting
With or without earth terminal
Dust-protected
Type V23154-C0xx Size I Type V23154-D0xx Size II
Hand solder terminals, silver-plated
Also for plug-in connection and screw xing
With earth terminal
Dust-protected
For sockets and hold-down springs see data sheet Accessories
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 5 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
Dimensions Dimensions in mm
Type V23162-A0xx Size I Type V23162-B0xx Size II / V23162-H0xx Size II
Hand solder terminals, silver or gold plated
Also for plug-in connection and screw xing
Hermetically sealed
For sockets and hold-down springs see data sheet Accessories
Mounting hole layout for V23154 - M/Nxx
View onto the component side of the PCB (top view)
M = Earth terminal
a) Hole for mechanical armature actuation, if required
b) Hole for socket mounting with screw M1.6.
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 6 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
Coil Data and operating range
Nominal voltage from 5 Vdc to 125 Vdc
Typical nominal power consumption, at 20 °C 0.8 W
Class of the operative range
acc to EN 61810-1 / IEC 61810-1 and VDE 0435 Part 201 2
Operating voltage (according to the coil type) max. 98% of the nominal voltage
Terminals:
Coil with 1 winding
Start 4 End 1
Coil with 2 windings (upon request)
Start 3 End 2 for winding I
Start 4 End 1 for winding II
The minimum voltage UI depends on the contact set and the ambient temperature, the maximum voltage UII only depen-
ds on the ambient temperature.
Between minimum voltage UI tamb and operating voltage U a safety margin of approx. 20% is recommended.
UI tamb (1.2) < UI
UII tamb
UI tamb = UI · U20 °C · kI tamb
UII tamb = UIl 20 °C · kII tamb
tamb = Ambient temperature
U = Operating voltage
UI tamb = Minimum voltage at ambient temperature, tamb
UII tamb = Maximum voltage at ambient temperature, tamb
kI and kII = Factors
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 7 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
Coil number
Monostable, 1 coil
711 = 5 V nominal voltage
712 = 6 V
717 = 12 V
721 = 24 V
726 = 48 V
734 = 60 V
735 = 110 V
703 = 125 V
V23154
Identication of the
Cradle N Relay, dust protected
Relay type
C0 = Size I,
for plug-in and screw xing, hand solder terminals silver-plated,
with earth terminal, dust-protected
D0 = Size II,
for plug-in and screw xing, hand solder terminals silver-plated,
with earth terminal, dust-protected
M0 = Size I,
for printed circuit mounting, with earth terminal, dust-protected
N0 = Size II,
for printed circuit mounting, with earth terminal, dust-protected
M4 = Size I,
for printed circuit mounting, without earth terminal, dust-protected
N4 = Size II,
Contact set / type of contact
see page 19
Ordering example:
V23154-D0721-B110
Cradle relay N, size II, plug-in, dust-protected, hand solder terminals, silver-plated, coil 24 Vdc,
4 changeover contact set, single contacts, contact material silver, gold-ashed.
Note:
The ordering scheme enables a multitude of variations. However, not all variations are dened as construction specica-
tions (ordering code) and thus in the current delivery program.
Relay Code
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 8 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
Coil number
Monostable, 1 coil
711 = 5 V nominal voltage
712 = 6 V
717 = 12 V
721 = 24 V
726 = 48 V
734 = 60 V
735 = 110 V
703 = 125 V
V23162
Identication of the
Cradle N Relay, hermetically sealed
Relay type
A0 = Size I,
for plug-in and screw xing, hand solder terminals tinned,
hermetically sealed
B0 = Size II,
for plug-in and screw xing, hand solder terminals tinned,
hermetically sealed
H0 = Size II,
for plug-in and screw, xing, hand solder terminals, gold-plated
Contact set / type of contact
see page 19
Ordering example:
V23162-A0721-B104
Cradle relay N, size I, plug-in, hemeticaly sealed, hand solder terminals, silver-plated, coil 24 Vdc,
2 changeover contact set, single contacts, contact material silver, gold-ashed.
Note:
The ordering scheme enables a multitude of variations. However, not all variations are dened as construction specica-
tions (ordering code) and thus in the current delivery program.
Relay Code
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 9 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
V23154-C0XX standard, size I
5.00 1.80 7.20 893 28 V23154C711B104 5-1393806-3
5.00 1.80 7.20 893 28 V23154C711B604 5-1393806-4
7.00 2.70 10.50 845 58 V23154C712B104 5-1393806-5
7.00 2.70 10.50 845 58 V23154C712B604 5-1393806-6
10.00 7.10 16.00 714 140 V23154C430B104 2-1393806-0
12.00 6.60 20.50 626 230 V23154C418B104 1393806-8
12.00 5.30 20.00 655 220 V23154C717B104 6-1393806-7
12.00 7.10 20.00 655 220 V23154C717C104 6-1393806-8
15.00 6.80 24.50 692 325 V23154C719B104 7-1393806-1
15.00 6.80 24.50 692 325 V23154C719B604 7-1393806-2
15.00 9.10 24.50 692 325 V23154C719C104 7-1393806-3
15.00 9.10 24.50 692 325 V23154C719C404 7-1393806-4
20.00 8.90 32.00 727 550 V23154C720B101 7-1393806-6
20.00 8.90 32.00 727 550 V23154C720B103 7-1393806-7
20.00 8.90 32.00 727 550 V23154C720B104 7-1393806-8
20.00 8.90 32.00 727 550 V23154C720B604 7-1393806-9
20.00 11.90 32.00 727 550 V23154C720C104 8-1393806-1
24.00 11.20 36.00 823 700 V23154C421B104 1-1393806-1
24.00 11.00 40.00 647 890 V23154C721B104 8-1393806-6
24.00 11.00 40.00 647 890 V23154C721B604 8-1393806-7
24.00 14.50 40.00 647 890 V23154C721C104 8-1393806-8
24.00 14.50 40.00 647 890 V23154C721C404 8-1393806-9
25.00 20.80 36.30 856 730 V23154C496C104 2-1393806-5
32.00 16.90 54.00 602 1700 V23154C722B101 9-1393806-3
32.00 16.90 54.00 602 1700 V23154C722B104 9-1393806-4
32.00 16.90 54.00 602 1700 V23154C722B604 9-1393806-5
32.00 22.60 54.00 602 1700 V23154C722C104 9-1393806-7
32.00 22.60 54.00 602 1700 V23154C722C404 9-1393806-8
32.00 22.60 54.00 602 1700 V23154C722C604 9-1393806-9
48.00 23.00 75.00 720 3200 V23154C726B101 1393807-5
48.00 23.00 75.00 720 3200 V23154C726B104 1393807-6
48.00 23.00 75.00 720 3200 V23154C726B604 1393807-7
48.00 30.00 75.00 720 3200 V23154C726C104 1393807-8
48.00 30.00 75.00 720 3200 V23154C726C404 1393807-9
60.00 27.00 92.00 766 4700 V23154C734B104 1-1393807-4
72.00 36.00 100.00 894 5800 V23154C404B104 1393806-2
72.00 36.20 114.00 682 7600 V23154C704B101 4-1393806-1
72.00 36.20 114.00 682 7600 V23154C704B102 4-1393806-2
72.00 36.20 114.00 682 7600 V23154C704B104 4-1393806-3
72.00 36.20 114.00 682 7600 V23154C704B108 4-1393806-4
72.00 36.20 114.00 682 7600 V23154C704B604 4-1393806-5
72.00 48.40 114.00 682 7600 V23154C704C104 4-1393806-6
72.00 48.40 114.00 682 7600 V23154C704C404 4-1393806-7
110.00 49.00 164.00 807 15000 V23154C735B104 1-1393807-6
125.00 61.00 190.00 748 20900 V23154C703B104 3-1393806-6
125.00 81.00 190.00 748 20900 V23154C703C101 3-1393806-7
125.00 81.00 190.00 748 20900 V23154C703C403 3-1393806-8
V23154-C0XX 5A, size I
1.10 0.40 1.70 807 1.5 V23154C702F101 3-1393806-3
1.10 0.40 1.70 807 1.5 V23154C702F106 3-1393806-4
7.00 2.70 10.50 845 58 V23154C712F105 5-1393806-7
7.00 2.70 10.50 845 58 V23154C712F106 5-1393806-8
Nominal
Voltage
Unom
Vdc
Operating voltage range Coil
power
mW
Coil
Resistance
Ω ± 15%
Relay
code
Tycp part
number
Minimum
Voltage Umin
Vdc
Maximum
voltage Umax
Vdc
Coil Data (values at 20 °C) Ordering Information
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 10 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
V23154-C0XX 5A, size I
9.00 3.90 14.00 736 110 V23154C715F105 6-1393806-3
12.00 7.10 20.00 655 220 V23154C717F105 6-1393806-9
12.00 7.10 20.00 655 220 V23154C717F106 7-1393806-0
14.50 6.60 24.00 647 325 V23154C719F105 7-1393806-5
19.00 8.20 31.00 681 530 V23154C720F105 8-1393806-2
19.00 8.20 31.00 681 530 V23154C720F106 8-1393806-3
24.00 15.00 36.00 823 700 V23154C421F105 1-1393806-3
24.00 11.00 40.00 647 890 V23154C721F105 9-1393806-1
24.00 11.00 40.00 647 890 V23154C721F106 9-1393806-2
33.00 16.00 54.00 641 1700 V23154C722F101 1393807-1
33.00 16.00 54.00 641 1700 V23154C722F105 1393807-2
33.00 16.00 54.00 641 1700 V23154C722F106 1393807-3
48.00 23.00 75.00 720 3200 V23154C726F105 1-1393807-1
48.00 30.00 75.00 720 3200 V23154C726F106 1-1393807-2
60.00 27.00 92.00 766 4700 V23154C734F106 1-1393807-5
72.00 36.20 114.00 682 7600 V23154C704F105 4-1393806-8
72.00 36.20 114.00 682 7600 V23154C704F106 1413000-2
110.00 49.00 164.00 807 15000 V23154C735F106 1-1393807-7
125.00 61.00 190.00 748 20900 V23154C703F106 4-1393806-0
V23154-D0XX standard, size II
5.00 2.50 7.20 893 28 V23154D711B110 2-1393808-8
5.00 2.50 7.20 893 28 V23154D711B628 2-1393808-9
5.00 3.00 7.20 893 28 V23154D711C110 3-1393808-0
5.00 3.00 7.20 893 28 V23154D711C410 3-1393808-1
7.00 3.60 10.50 845 58 V23154D712B110 3-1393808-3
7.00 3.60 10.50 845 58 V23154D712B610 3-1393808-4
7.00 4.40 10.50 845 58 V23154D712C110 3-1393808-5
8.50 4.80 14.00 657 110 V23154D715B110 3-1393808-8
8.50 4.80 14.00 657 110 V23154D715B610 3-1393808-9
8.50 5.80 14.00 657 110 V23154D715C110 4-1393808-0
10.00 5.80 16.50 667 150 V23154D716B110 4-1393808-3
10.00 5.80 16.50 667 150 V23154D716B117 8-1422029-0
10.00 5.80 16.50 667 150 V23154D716B610 4-1393808-5
10.00 7.10 16.50 667 150 V23154D716C110 4-1393808-6
12.00 8.80 20.50 626 230 V23154D418B110 3-1393807-0
12.00 7.10 20.00 655 220 V23154D717B110 4-1393808-9
12.00 7.10 20.00 655 220 V23154D717B112 5-1393808-0
12.00 7.10 20.00 655 220 V23154D717B124 5-1393808-1
12.00 7.10 20.00 655 220 V23154D717B529 5-1393808-2
12.00 7.10 20.00 655 220 V23154D717B610 8-1422029-2
12.00 10.50 20.00 655 220 V23154D717C110 5-1393808-3
15.00 9.10 24.50 692 325 V23154D719B110 5-1393808-6
15.00 9.10 24.50 692 325 V23154D719B112 5-1393808-7
15.00 9.10 24.50 692 325 V23154D719B117 5-1393808-8
15.00 9.10 24.50 692 325 V23154D719B124 5-1393808-9
15.00 9.10 24.50 692 325 V23154D719B210 6-1393808-0
15.00 9.10 24.50 692 325 V23154D719B610 6-1393808-1
15.00 11.00 24.50 692 325 V23154D719C110 1413000-3
16.00 15.20 27.00 656 390 V23154D479B110 7-1393807-5
16.00 15.20 27.00 656 390 V23154D479B111 7-1393807-6
16.00 15.20 27.00 656 390 V23154D479B117 1422029-6
16.00 15.20 27.00 656 390 V23154D479B128 7-1393807-7
Nominal
Voltage
Unom
Vdc
Operating voltage range Coil
power
mW
Coil
Resistance
Ω ± 15%
Relay
code
Tycp part
number
Minimum
Voltage Umin
Vdc
Maximum
voltage Umax
Vdc
Coil Data (values at 20 °C) Ordering Information
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 11 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
V23154-D0XX standard, size II
16.00 18.90 27.00 656 390 V23154D479C110 7-1393807-8
20.00 11.90 32.00 727 550 V23154D720B110 6-1393808-5
20.00 11.90 32.00 727 550 V23154D720B112 6-1393808-6
20.00 11.90 32.00 727 550 V23154D720B116 6-1393808-7
20.00 11.90 32.00 727 550 V23154D720B117 6-1393808-8
20.00 11.90 32.00 727 550 V23154D720B610 6-1393808-9
20.00 14.40 32.00 727 550 V23154D720C110 7-1393808-0
20.00 14.40 32.00 727 550 V23154D720C112 7-1393808-1
20.00 14.40 32.00 727 550 V23154D720C410 7-1393808-3
20.00 14.40 32.00 727 550 V23154D720C412 7-1393808-4
20.00 14.40 32.00 727 550 V23154D720C610 7-1393808-5
24.00 15.00 36.00 823 700 V23154D421B110 3-1393807-7
24.00 15.00 36.00 823 700 V23154D421B117 3-1393807-9
24.00 15.00 36.00 823 700 V23154D421B124 4-1393807-0
24.00 15.00 36.00 823 700 V23154D421B612 4-1393807-1
24.00 18.20 36.00 823 700 V23154D421C110 4-1393807-2
24.00 18.20 36.00 823 700 V23154D421C410 4-1393807-3
24.00 14.50 40.00 647 890 V23154D721B110 8-1393808-3
24.00 14.50 40.00 647 890 V23154D721B112 8-1393808-4
24.00 14.50 40.00 647 890 V23154D721B114 8-1393808-5
24.00 14.50 40.00 647 890 V23154D721B116 8-1393808-6
24.00 14.50 40.00 647 890 V23154D721B117 8-1393808-7
24.00 14.50 40.00 647 890 V23154D721B124 8-1393808-8
24.00 14.50 40.00 647 890 V23154D721B129 8-1393808-9
24.00 14.50 40.00 647 890 V23154D721B142 9-1393808-0
24.00 14.50 40.00 647 890 V23154D721B510 9-1393808-1
24.00 14.50 40.00 647 890 V23154D721B610 9-1393808-2
24.00 14.50 40.00 647 890 V23154D721B612 9-1393808-3
24.00 22.00 40.00 647 890 V23154D721C110 9-1393808-5
24.00 18.00 40.00 647 890 V23154D721C112 9-1393808-6
24.00 18.00 40.00 647 890 V23154D721C114 9-1393808-7
24.00 18.00 40.00 647 890 V23154D721C117 9-1393808-8
24.00 18.00 40.00 647 890 V23154D721C410 9-1393808-9
25.00 20.80 36.30 856 730 V23154D496B110 8-1393807-2
25.00 20.80 36.30 856 730 V23154D496B112 8-1393807-3
32.00 22.60 54.00 602 1700 V23154D722B110 1-1393809-4
32.00 22.60 54.00 602 1700 V23154D722B112 1-1393809-5
32.00 22.60 54.00 602 1700 V23154D722B113 1-1393809-6
32.00 22.60 54.00 602 1700 V23154D722B114 1-1393809-7
32.00 22.60 54.00 602 1700 V23154D722B116 1-1393809-8
32.00 22.60 54.00 602 1700 V23154D722B117 1-1393809-9
32.00 22.60 54.00 602 1700 V23154D722B124 2-1393809-0
32.00 22.60 54.00 602 1700 V23154D722B129 1413000-1
32.00 22.60 54.00 602 1700 V23154D722B129 1419138-9
32.00 22.60 54.00 602 1700 V23154D722B610 2-1393809-1
32.00 33.80 54.00 602 1700 V23154D722C110 2-1393809-2
32.00 33.80 54.00 602 1700 V23154D722C410 2-1393809-3
48.00 30.00 75.00 720 3200 V23154D726B110 3-1393809-2
48.00 30.00 75.00 720 3200 V23154D726B112 3-1393809-4
48.00 30.00 75.00 720 3200 V23154D726B117 3-1393809-5
48.00 30.00 75.00 720 3200 V23154D726B124 3-1393809-6
48.00 30.00 75.00 720 3200 V23154D726B129 3-1393809-7
48.00 30.00 75.00 720 3200 V23154D726B610 3-1393809-8
Nominal
Voltage
Unom
Vdc
Operating voltage range Coil
power
mW
Coil
Resistance
Ω ± 15%
Relay
code
Tycp part
number
Minimum
Voltage Umin
Vdc
Maximum
voltage Umax
Vdc
Coil Data (values at 20 °C) Ordering Information
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 12 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
V23154-D0XX standard, size II
48.00 45.00 75.00 720 3200 V23154D726C110 3-1393809-9
48.00 37.00 75.00 720 3200 V23154D726C112 4-1393809-0
48.00 37.00 75.00 720 3200 V23154D726C117 4-1393809-1
48.00 37.00 75.00 720 3200 V23154D726C410 4-1393809-2
60.00 36.00 92.00 766 4700 V23154D734B110 5-1393809-6
60.00 36.00 92.00 766 4700 V23154D734B610 5-1393809-7
60.00 43.00 92.00 766 4700 V23154D734C410 5-1393809-8
72.00 48.00 100.00 894 5800 V23154D404B110 1-1393807-8
72.00 48.00 100.00 894 5800 V23154D404B112 1-1393807-9
72.00 48.00 100.00 894 5800 V23154D404B117 2-1393807-0
72.00 48.00 100.00 894 5800 V23154D404B610 2-1393807-1
72.00 48.40 114.00 682 7600 V23154D704B110 1393808-6
72.00 48.40 114.00 682 7600 V23154D704B112 1393808-8
72.00 48.40 114.00 682 7600 V23154D704B114 1393808-9
72.00 48.40 114.00 682 7600 V23154D704B116 1-1393808-0
72.00 48.40 114.00 682 7600 V23154D704B117 1-1393808-1
72.00 48.40 114.00 682 7600 V23154D704B119 1-1393808-2
72.00 48.40 114.00 682 7600 V23154D704B121 1-1393808-3
72.00 48.40 114.00 682 7600 V23154D704B210 1-1393808-4
72.00 58.70 114.00 682 7600 V23154D704C110 1-1393808-6
72.00 58.70 114.00 682 7600 V23154D704C112 1-1393808-7
72.00 58.70 114.00 682 7600 V23154D704C113 1-1393808-8
110.00 65.00 164.00 807 15000 V23154D735B110 6-1393809-2
110.00 65.00 164.00 807 15000 V23154D735B117 6-1393809-3
110.00 65.00 164.00 807 15000 V23154D735B610 6-1393809-4
125.00 81.00 190.00 748 20900 V23154D703B110 1393808-1
125.00 81.00 190.00 748 20900 V23154D703B117 1393808-3
V23154-D0XX 5A , size II
5.00 1.80 7.20 893 28 V23154D711F104 3-1393808-2
7.00 3.60 10.50 845 58 V23154C712B104 3-1393808-6
12.00 6.60 20.50 626 230 V23154D418F104 3-1393807-1
12.00 7.10 20.00 655 220 V23154D717F104 5-1393808-4
15.00 6.80 24.50 692 325 V23154D719F104 6-1393808-2
20.00 11.90 32.00 727 550 V23154D720F104 7-1393808-6
20.00 8.90 32.00 727 550 V23154D720F304 7-1393808-7
24.00 15.00 36.00 823 700 V23154D421F104 4-1393807-4
24.00 11.00 40.00 647 890 V23154D721F104 1393809-1
24.00 14.50 40.00 647 890 V23154D721F304 1393809-2
32.00 22.60 54.00 602 1700 V23154D722F104 2-1393809-4
48.00 30.00 75.00 720 3200 V23154D726F104 4-1393809-4
60.00 27.00 92.00 766 4700 V23154D734F104 6-1393809-0
72.00 36.00 100.00 894 5800 V23154D404F104 2-1393807-2
72.00 48.40 114.00 682 7600 V23154D704F104 1-1393808-9
110.00 65.00 164.00 807 15000 V23154D735F104 6-1393809-5
125.00 81.00 190.00 748 20900 V23154D703F104 1393808-4
V23154-M0XX standard, size I
7.00 2.70 10.50 845 58 V23154M712B104 1-1393810-8
12.00 5.30 20.00 655 220 V23154M717B104 2-1393810-1
12.00 7.10 20.00 655 220 V23154M717C104 2-1393810-2
15.00 6.80 24.50 692 325 V23154M719B104 2-1393810-3
15.00 9.10 24.50 692 325 V23154M719C104 2-1393810-4
Nominal
Voltage
Unom
Vdc
Operating voltage range Coil
power
mW
Coil
Resistance
Ω ± 15%
Relay
code
Tycp part
number
Minimum
Voltage Umin
Vdc
Maximum
voltage Umax
Vdc
Coil Data (values at 20 °C) Ordering Information
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 13 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
V23154-M0XX standard, size I
20.00 8.90 32.00 727 550 V23154M720B104 2-1393810-5
20.00 8.90 32.00 727 550 V23154M720B604 2-1393810-6
24.00 11.00 40.00 647 890 V23154M721B104 2-1393810-7
24.00 11.00 40.00 647 890 V23154M721B604 2-1393810-9
24.00 14.50 40.00 647 890 V23154M721C104 3-1393810-0
32.00 16.90 54.00 602 1700 V23154M722B104 3-1393810-4
32.00 16.90 54.00 602 1700 V23154M722B604 3-1393810-5
33.00 22.60 54.00 641 1700 V23154M722C104 2-1419172-5
33.00 22.60 54.00 641 1700 V23154M722C404 3-1393810-6
48.00 23.00 75.00 720 3200 V23154M726B104 3-1393810-8
48.00 30.00 75.00 720 3200 V23154M726C104 4-1393810-0
72.00 36.20 114.00 682 7600 V23154M704B104 1-1393810-5
125.00 61.00 190.00 748 20900 V23154M703B104 1-1393810-4
V23154-M0XX 5A, size I
7.00 2.70 10.50 845 58 V23154M712F101 1-1393810-9
19.00 8.20 31.00 681 530 V23154M720F105 2-1422030-5
24.00 11.00 40.00 647 890 V23154M721F101 3-1393810-1
24.00 11.00 40.00 647 890 V23154M721F105 3-1393810-2
24.00 11.00 40.00 647 890 V23154M721F106 3-1393810-3
33.00 16.00 54.00 641 1700 V23154M722F106 3-1393810-7
48.00 23.00 75.00 720 3200 V23154M726F106 4-1393810-1
72.00 36.20 114.00 682 7600 V23154M704F101 1-1393810-6
V23154-M4XX standard, size I
12.00 7.10 20.00 655 220 V23154M4717C104 4-1393810-5
15.00 9.10 24.50 692 325 V23154M4719C104 4-1393810-6
24.00 14.50 40.00 647 890 V23154M4721C104 4-1393810-7
V23154-M4XX 5A, size I
24.00 11.00 40.00 647 890 V23154M4721F106 2-1422030-4
V23154-N0XX standard, size II
7.00 3.60 10.50 845 58 V23154N712B110 5-1393810-4
10.00 7.10 16.50 667 150 V23154N716C110 5-1393810-8
12.00 7.10 20.00 655 220 V23154N717B110 5-1393810-9
12.00 10.50 20.00 655 220 V23154N717C414 6-1393810-0
15.00 9.10 24.50 692 325 V23154N719B110 6-1393810-3
20.00 11.90 32.00 727 550 V23154N720B110 6-1393810-4
20.00 11.90 32.00 727 550 V23154N720B610 6-1393810-5
20.00 17.70 32.00 727 550 V23154N720C110 6-1393810-6
20.00 14.40 32.00 727 550 V23154N720C112 6-1393810-7
20.00 17.70 32.00 727 550 V23154N720C410 6-1393810-8
24.00 14.50 40.00 647 890 V23154N721B110 7-1393810-0
24.00 14.50 40.00 647 890 V23154N721B112 7-1393810-1
24.00 14.50 40.00 647 890 V23154N721B610 7-1393810-2
24.00 22.00 40.00 647 890 V23154N721C110 7-1393810-3
24.00 22.00 40.00 647 890 V23154N721C114 7-1393810-4
32.00 22.60 54.00 602 1700 V23154N722B110 7-1393810-6
32.00 33.80 54.00 602 1700 V23154N722C110 7-1393810-7
32.00 27.40 54.00 602 1700 V23154N722C112 7-1393810-8
48.00 30.00 75.00 720 3200 V23154N726B110 8-1393810-0
48.00 45.00 75.00 720 3200 V23154N726C110 8-1393810-2
Nominal
Voltage
Unom
Vdc
Operating voltage range Coil
power
mW
Coil
Resistance
Ω ± 15%
Relay
code
Tycp part
number
Minimum
Voltage Umin
Vdc
Maximum
voltage Umax
Vdc
Coil Data (values at 20 °C) Ordering Information
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 14 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
48.00 37.00 75.00 720 3200 V23154N726C117 8-1393810-3
48.00 37.00 75.00 720 3200 V23154N726C119 8-1393810-4
48.00 45.00 75.00 720 3200 V23154N726C121 8-1393810-5
48.00 45.00 75.00 720 3200 V23154N726C124 8-1393810-6
60.00 36.00 92.00 766 4700 V23154N734B110 8-1393810-9
72.00 48.00 100.00 894 5800 V23154N404B110 4-1393810-8
72.00 58.70 114.00 682 7600 V23154N704C114 5-1393810-2
72.00 58.70 114.00 682 7600 V23154N704C121 5-1393810-3
V23154-N0XX 5A, size II
12.00 5.30 20.00 655 220 V23154N717F104 6-1393810-1
20.00 8.90 32.00 727 550 V23154N720F104 6-1393810-9
24.00 11.00 40.00 647 890 V23154N721F104 7-1393810-5
32.00 16.90 54.00 602 1700 V23154N722F104 7-1393810-9
48.00 23.00 75.00 720 3200 V23154N726F104 8-1393810-7
60.00 27.00 92.00 766 4700 V23154N734F104 9-1393810-0
72.00 36.20 114.00 682 7600 V23154N704F104 1422030-1
125.00 61.00 190.00 748 20900 V23154N703F104 5-1393810-1
V23154-N4XX standard, size II
10.00 9.00 16.50 667 150 V23154N4716C110 1393811-1
20.00 11.90 32.00 727 550 V23154N4720B110 1393811-2
24.00 22.00 40.00 647 890 V23154N4721C110 1393811-7
48.00 30.00 75.00 720 3200 V23154N4726B110 1-1393811-0
60.00 36.00 92.00 766 4700 V23154N4734B110 1-1393811-1
V23154-N4XX 5A, size II
24.00 11.00 40.00 647 890 V23154N4721F104 1393811-8
60.00 27.00 92.00 766 4700 V23154N4734F104 1-1393811-2
110.00 49.00 164.00 807 15000 V23154N4735F104 1-1393811-3
V23162-A0XX standard, size I
5.00 1.80 7.20 893 28 V23162A711B104 2-1393818-5
12.00 5.30 20.00 655 220 V23162A717B104 2-1393818-8
12.00 5.30 20.00 655 220 V23162A717B604 2-1393818-9
15.00 6.80 24.50 692 325 V23162A719B104 3-1393818-2
20.00 8.90 32.00 727 550 V23162A720B104 3-1393818-3
20.00 8.90 32.00 727 550 V23162A720B604 3-1393818-4
20.00 11.90 32.00 727 550 V23162A720C104 3-1393818-5
20.00 11.90 32.00 727 550 V23162A720C404 3-1393818-6
24.00 11.20 36.00 823 700 V23162A421B104 1393818-6
24.00 11.20 36.00 823 700 V23162A421B604 1393818-7
24.00 11.00 40.00 647 890 V23162A721B104 3-1393818-7
24.00 11.00 40.00 647 890 V23162A721B604 3-1393818-8
24.00 14.50 40.00 647 890 V23162A721C104 4-1393818-0
24.00 14.50 40.00 647 890 V23162A721C404 4-1393818-1
32.00 16.90 54.00 602 1700 V23162A722B101 4-1393818-5
32.00 16.90 54.00 602 1700 V23162A722B104 4-1393818-6
32.00 16.90 54.00 602 1700 V23162A722B604 4-1393818-7
32.00 22.60 54.00 602 1700 V23162A722C104 4-1393818-8
48.00 23.00 75.00 720 3200 V23162A726B104 5-1393818-1
48.00 23.00 75.00 720 3200 V23162A726B604 5-1393818-2
48.00 30.00 75.00 720 3200 V23162A726C404 5-1393818-3
48.00 30.00 75.00 720 3200 V23162A735C104 5-1393818-5
72.00 36.00 100.00 894 5800 V23162A404B104 1393818-1
Nominal
Voltage
Unom
Vdc
Operating voltage range Coil
power
mW
Coil
Resistance
Ω ± 15%
Relay
code
Tycp part
number
Minimum
Voltage Umin
Vdc
Maximum
voltage Umax
Vdc
Coil Data (values at 20 °C) Ordering Information
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 15 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
V23162-A0XX standard, size I
72.00 36.00 100.00 894 5800 V23162A404B604 1419147-6
72.00 36.20 114.00 682 7600 V23162A704B104 1-1393818-9
72.00 36.20 114.00 682 7600 V23162A704B604 2-1393818-0
72.00 48.40 114.00 682 7600 V23162A704C402 2-1393818-1
72.00 48.40 114.00 682 7600 V23162A704C404 2-1393818-2
110.00 65.00 164.00 807 15000 V23162A735C404 5-1393818-6
125.00 61.00 190.00 748 20900 V23162A703B104 1-1393818-6
125.00 81.00 190.00 748 20900 V23162A703C404 1-1393818-7
V23162-A0XX 5A, size I
1.10 0.50 1.70 807 1.5 V23162A702F106 1-1393818-5
12.00 5.30 20.00 655 220 V23162A717F105 3-1393818-0
12.00 7.10 20.00 655 220 V23162A717F106 3-1393818-1
24.00 11.00 40.00 647 890 V23162A721F101 4-1393818-2
24.00 11.00 40.00 647 890 V23162A721F105 4-1393818-3
24.00 14.50 40.00 647 890 V23162A721F106 4-1393818-4
33.00 16.00 54.00 641 1700 V23162A722F101 4-1393818-9
33.00 16.00 54.00 641 1700 V23162A722F105 5-1393818-0
48.00 30.00 75.00 720 3200 V23162A726F106 5-1393818-4
72.00 48.00 100.00 894 5800 V23162A404F106 1393818-2
72.00 36.20 114.00 682 7600 V23162A704F105 2-1393818-3
72.00 48.40 114.00 682 7600 V23162A704F106 2-1393818-4
125.00 81.00 190.00 748 20900 V23162A703F106 1-1393818-8
V23162-B0XX standard, size II
7.00 3.60 10.50 845 58 V23162B712B110 8-1393818-1
8.50 7.60 14.00 657 110 V23162B715C110 8-1393818-4
10.00 5.80 16.50 667 150 V23162B716B110 8-1393818-5
12.00 7.10 20.00 655 220 V23162B717B110 8-1393818-7
12.00 7.10 20.00 655 220 V23162B717B610 8-1393818-8
12.00 8.70 20.00 655 220 V23162B717C112 8-1393818-9
15.00 9.10 24.50 692 325 V23162B719B110 9-1393818-1
20.00 11.90 32.00 727 550 V23162B720B110 9-1393818-4
20.00 11.90 32.00 727 550 V23162B720B112 9-1393818-5
20.00 11.90 32.00 727 550 V23162B720B117 9-1393818-6
20.00 11.90 32.00 727 550 V23162B720B610 9-1393818-7
20.00 17.70 32.00 727 550 V23162B720C110 9-1393818-8
20.00 14.40 32.00 727 550 V23162B720C112 9-1393818-9
20.00 17.70 32.00 727 550 V23162B720C410 1393819-1
24.00 15.00 36.00 823 700 V23162B421B110 6-1393818-1
24.00 15.00 36.00 823 700 V23162B421B610 6-1393818-3
24.00 14.50 40.00 647 890 V23162B721B110 1393819-4
24.00 14.50 40.00 647 890 V23162B721B112 1393819-5
24.00 14.50 40.00 647 890 V23162B721B610 1-1393819-0
24.00 22.00 40.00 647 890 V23162B721C110 1-1393819-2
24.00 22.00 40.00 647 890 V23162B721C410 1-1393819-3
32.00 22.60 54.00 602 1700 V23162B722B110 1-1393819-5
32.00 22.60 54.00 602 1700 V23162B722B112 1-1393819-6
32.00 22.60 54.00 602 1700 V23162B722B610 1-1393819-7
32.00 33.80 54.00 602 1700 V23162B722C410 1-1393819-8
48.00 30.00 75.00 720 3200 V23162B726B110 2-1393819-0
48.00 30.00 75.00 720 3200 V23162B726B112 2-1393819-1
48.00 30.00 75.00 720 3200 V23162B726B610 2-1393819-3
Nominal
Voltage
Unom
Vdc
Operating voltage range Coil
power
mW
Coil
Resistance
Ω ± 15%
Relay
code
Tycp part
number
Minimum
Voltage Umin
Vdc
Maximum
voltage Umax
Vdc
Coil Data (values at 20 °C) Ordering Information
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 16 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
V23162-B0XX standard, size II
48.00 45.00 75.00 720 3200 V23162B726C110 2-1393819-6
60.00 36.00 92.00 766 4700 V23162B734B610 2-1393819-9
72.00 48.00 100.00 894 5800 V23162B404B110 5-1393818-7
72.00 48.40 114.00 682 7600 V23162B704B110 7-1393818-6
72.00 48.40 114.00 682 7600 V23162B704B112 7-1393818-7
72.00 48.40 114.00 682 7600 V23162B704B610 7-1393818-8
110.00 65.00 164.00 807 15000 V23162B735B110 3-1393819-0
110.00 65.00 164.00 807 15000 V23162B735B610 3-1393819-1
110.00 98.00 164.00 807 15000 V23162B735C110 3-1393819-2
110.00 98.00 164.00 807 15000 V23162B735C410 3-1393819-3
125.00 81.00 190.00 748 20900 V23162B703B110 7-1393818-3
125.00 81.00 190.00 748 20900 V23162B703B610 7-1393818-4
V23162-B0XX 5A, size II
7.00 3.60 10.50 845 58 V23162B712F104 8-1393818-2
12.00 7.10 20.00 655 220 V23162B717F104 9-1393818-0
15.00 9.10 24.50 692 325 V23162B719F104 9-1393818-3
20.00 11.90 32.00 727 550 V23162B720F104 1393819-2
24.00 15.00 36.00 823 700 V23162B421F104 6-1393818-4
24.00 14.50 40.00 647 890 V23162B721F104 1-1393819-4
32.00 22.60 54.00 602 1700 V23162B722F104 1-1393819-9
48.00 30.00 75.00 720 3200 V23162B726F104 2-1393819-7
72.00 48.40 114.00 682 7600 V23162B704F104 8-1393818-0
110.00 65.00 164.00 807 15000 V23162B735F104 3-1393819-4
125.00 81.00 190.00 748 20900 V23162B703F104 7-1393818-5
V23162-H0XX standard, size II
8.50 5.10 14.00 657 110 V23162H715B110 4-1393819-2
20.00 11.90 32.00 727 550 V23162H720B110 4-1393819-4
20.00 11.90 32.00 727 550 V23162H720B610 4-1393819-6
20.00 17.70 32.00 727 550 V23162H720C410 4-1393819-7
20.00 17.70 32.00 727 550 V23162H720C610 4-1393819-8
24.00 15.00 36.00 823 700 V23162H421B610 3-1393819-7
24.00 14.50 40.00 647 890 V23162H721B110 4-1393819-9
24.00 14.50 40.00 647 890 V23162H721B610 5-1393819-0
24.00 22.00 40.00 647 890 V23162H721C410 5-1393819-1
32.00 33.80 54.00 602 1700 V23162H722C110 5-1393819-3
32.00 33.80 54.00 602 1700 V23162H722C410 5-1393819-4
V23162-H0XX 5A, size II
7.00 3.60 10.50 845 58 V23162H712F104 4-1393819-1
15.00 9.10 24.50 692 325 V23162H719F104 4-1393819-3
24.00 14.50 40.00 647 890 V23162H721F104 5-1393819-2
24.00 14.50 40.00 647 890 V23162H721F107 1419147-7
32.00 22.60 54.00 602 1700 V23162H722F104 5-1393819-5
72.00 48.40 114.00 682 7600 V23162H704F104 4-1393819-0
125.00 81.00 190.00 748 20900 V23162H703F104 3-1393819-9
Nominal
Voltage
Unom
Vdc
Operating voltage range Coil
power
mW
Coil
Resistance
Ω ± 15%
Relay
code
Tycp part
number
Minimum
Voltage Umin
Vdc
Maximum
voltage Umax
Vdc
Coil Data (values at 20 °C) Ordering Information
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 17 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
Instructions for Impulse Operation
The maximum voltage stated in the table (page 6) can be increased for impulse operation as follows:
UII Impuls = UII tamb . q
UII tamb = Maximum continuous voltage at ambient temperature t amb
q = Factor
The impulse voltage must not exceed 80% of the test voltage (winding/frame or winding/winding) or 2.5 times the value of
the maximum voltage listed in the table (page 6).
Ift ED
3 s then q =
Ift ED = Pulse width
t2 = Cycle time
If tED = > 3 s the value of q must be obtained from the nomograph (next page).
Examples of various periodic pulse trains (energizing side)
1. Periodic recurrence of one energizing pulse
2. Periodic recurrence of two unequal energizing pulses
tED = tI + tII
tI + tII = Pulse widths within one cycle
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 18 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
Nomograph for Determining Factor q
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 19 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
Contact Data
Ordering code block 3 B104/B110/
B112
B604/B610/
B612
C104/C110/
C112 C404/C410 F104 ... F107
Number of contacts and Type max. 4 changeover contacts, 2 break contacts or 6 make contacts
Contact assembly single contacts bifurcated contacts single contacts
Contact material silver,
gold-ashed gold F silver,
gold-ashed gold F silver,
gold-ashed
Max. switching voltage 150 Vdc 36 Vdc 150 Vdc 36 Vdc 250 Vdc
125 Vac 30 Vac 125 Vac 30 Vac 250 Vac
Max. switching current 2 A 0.2 A 2 A 0.2 A 5 A
Max. switching capacity
35 to 70 W
see load limit
curve below
50 VA
5 W
5 VA
35 to 70 W
see load limit
curve below
50 VA
5 W
5 VA
50 to 140 W
see load limit
curve below
500 VA
Max. continuous current at
max. ambient temperature 2 A 5 A
70 W
40 W
150
120
100
80
60
50
40
30
V_
U
0,3 0,4 0,5 0,6 0,8 1 1,5 2A
I
250
200
150
100
80
60
50
40
30
20
V_
100 W
140 W
50 W
0,2 0,3 0,4 0,5 0,6 0,8 1 1,5 2 3 4 5A
I
U
Max. DC Load Breaking Capacity
Safe breaking, no stationary arc
Contact material silver, gold-ashed
for contact sets F1xx
I = switching current
U = switching voltage
for contact sets B1xx and C1 xx
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 20 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
Size I
Number of contacts and type 2 changeover contacts 2 make contacts 2 break contacts 1 break
1 make contact
Symbols with base conncections
3 2 4 1
- + - +
coil I coil II
Contacts in release condition,
coil polarity to set the relay
Contact assembly single
contacts
bifurcated
contacts single contacts
Contact material silver, gold-ashed
Ordering code block 3 B104 C104 F105 F107 F106
Contact material gold F
Ordering code block 3 B604 C404
Size II
Number of contacts and type 6 make contacts 4 changover contacts 2 changover
contacts
Symbols with base conncections
3 2 4 1
- + - +
coil I coil II
Contacts in release condition,
coil polarity to set the relay
Contact assembly single
contacts
bifurcated
contacts
single
contacts
bifurcated
contacts
single
contacts
Contact material silver, gold-ashed
Ordering code block 3 B112 C112 B110 C110 F104
Contact material gold F
Ordering code block 3 B612 B610 C410
Contact sets
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 21 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
Insulation
General Data
Ordering code block 3 B1xx B6xx C1xx C4xx F1xx
Test voltage (1 min)
winding / frame
contact / contact
contact / frame
contact / coil
500 Vacrms
500 Vacrms
500 Vacrms
1000 Vacrms
500 Vacrms
1000 Vacrms
1000 Vacrms
1500 Vacrms
Ordering code block 3 B1xx B6xx C1xx C4xx F1xx
Operate time at Unom and 20 °C, typical 7.5 ms
Reset time typical 3 ms
Maximum switching rate without load 50 operations/s 10
operations/s
Ambient temperature range
acc. to EN 61810-1 / IEC 61810-1 and
VDE 0435 part 201
-40 °C ... +70 °C
Thermal resistance 50 K/W
Maximum temperature 100 °C
Continuous thermal load 1.6 W
Degree of protection acc. to EN 60529 /
IEC 60529 / VDE 0470 part 1
dust-protected IP 30
or hermetically sealed IP 67
Mechanical endurance approx.108
operations
approx. 107
operations
Mounting position any
Processing information Ultrasonic cleaning should be avoided if possible or carried out only after
consulting the manufacturer
Weight
V23154-C0/-MO Size I
V23154-D0/-NO Size II
V23162-A0xxx Size I
V23162-B0xxx Size II
approx. 20 g
approx. 25 g
approx. 30 g
approx. 35 g
108-98012 Rev. C
All specications subject to change. Consult Tyco Electronics for latest specications. 22 of 23
Telecom-, Signal and RF Relays
Cradle Relay N V23154/V23162
AXICOM
IM Relays
4th generation slim line – low prole polarized 2 c/o telecom signal relay
with bifurcated contacts, available as non latching or latching relay with
1 coil. Nominal voltage range from 1.5 ... 24 V, coil power consumption of 50 ...
200 mW, latching relays with 1 coil 100 mW. The IM relay is available as
through hole and surface mount type (J-Legs and Gull Wings) and capable
to switch loads up to 60 W/62,5 VA. It is currently the only 2 A rated 4G
relay on the market. Dielectric strength fullls the Telcordia requirements
according GR 1089 (2,5 kV 2 / 10 µs) and FCC part 68 (1,5 kV 10 / 160 µs).
The IM relay is tested according CECC/IECQ and certied in accordance
with IEC/EN 60950 and UL 60950.
Dimensions approx. 10 x 6 mm board space and 5.65 mm height.
P2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,
available as non latching or latching relay with 1 or 2 coils. Nominal voltage
range from 3 ... 24 V, coil power consumption 140 mW, latching relays
with 1 coil 70 mW. The P2 Relay is available as through hole or surface
mount type and capable to switch currents up to 5 A. Dielectric strength
fullls the Telcordia requirements according GR 1089 (2,5 kV – 2 / 10 µs)
and FCC part 68 (1,5 kV – 10 / 160 µs). The P2 relay is tested according
CECC/IECQ and certied in accordance with IEC/EN 60950 and UL 60950.
Dimensions approx. 15 x 7,5 mm board space and 10 mm height.
FX2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,
available as non latching or latching relay with 1 coil. Nominal voltage
range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the high
sensitive version, 140... 300 mW for the standard version, latching relays
with 1 coil 100 mW. The FX2 relay is available as through hole type and
capable to switch loads up to 60 W/62,5 VA. Dielectric strength fullls the
Telcordia requirements according GR 1089 (2,5 kV – 2 / 10 µs) and FCC
part 68 (1,5 kV – 10 / 160 µs). The FX2 relay is tested according CECC/
IECQ and certied in accordance with IEC/EN 60950 and UL 60950.
Dimensions approx. 15 x 7,5 mm board space and 10,7 mm height.
FT2 / FU2 Relays
3rd generation non polarized, non latching 2 c/o telecom relay with bifurca-
ted contacts. Nominal voltage range from 3 ... 48 V, coil power consumption
200 ... 300 mW. Most sensitive 48 V relay. Available as through hole and
surface mount type. Dielectric strength fullls the Telcordia requirements
according GR 1089 (2,5 kV 2 / 10 µs) and FCC part 68 (1,5 kV 10 /
160 µs). The FT2/FU2 relay is tested according CECC/IECQ and certied
in accordance with IEC/EN 60950 and UL 60950.
Dimensions approx. 15 x 7,5 mm board space and 10 mm height.
FP2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts,
available as non latching or latching relay with 1 or 2 coils. Nominal voltage
range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the
high sensitive version, 140... 300 mW for the standard version, latching
relays with 1 coil 100 mW.. The FP2 Relay is available as through hole
type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength
fullls FCC part 68 (1,5 kV 10 / 160 µs). The FP2 is tested according
CECC/IECQ approved.
Dimensions approx. 14 x 9 mm board space and 5 mm height.
MT2
2nd generation non polarized, non latching 2 c/o telecom and si-
gnal relay with bifurcated contacts. Nominal voltage range from 3
... 48 V, coil power consumption 150/200/300/400 and 550 mW.
Dielectric strength fulfills the requirements according FCC part 68
(1,5 kV – 10 / 160 µs).
Dimensions approx. 20 x 10 mm board space and 11 mm height.
D2n Relays
2nd generation non polarized 2 c/o relay for telecom and various other ap-
plications. Nominal voltage range from 3 ... 48 V, coil power consumption from
150 .... 500 mW. The D2n relay is capable to switch currents up to 3 A. Dielectric
strength fullls the requirements according FCC part 68 (1,5 kV 10 / 160 µs).
Dimensions approx. 20 x10 mm board space and 11 mm height.
P1 Relays
Extremely sensitive, polarized 1 c/o relay with bifurcated contacts for a
wide range of applications, available as non latching or latching relay with
1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption
65 mW, latching relays with 1 coil 30 mW. The P1 relay is available as
through hole or surface mount type and capable to switch currents up to 1
A. Dielectric strength fullls the requirements according FCC part 68 (1,5
kV 10 / 160 µs). Dimensions approx. 13 x 7,6 mm board space and 7
mm height for THT or 8 mm height for SMT version.
W11 Relays
Low cost, non polarized 1 c/o relay for various applications. Nominal
voltage range from 3 ... 24 V, coil power consumption 450 mW, sensitive
versions 200 mW. The W11 relay is capable to switch currents up to 3 A.
Dielectric strength 1000 Vrms.
Dimensions approx. 15,6 x 10,6 mm board space and 11,5 mm height.
Reed Relays
High sensitive, non polarized relay for telecom and various other applica-
tions, available with 1 n/o, 2 n/o or 1c/o contacts. Nominal voltage range
from 5 ... 24 V, coil power consumption 50...280 mW for 1 n/o and 125 ...
280 mW for 2 n/o or 1 c/o versions. Reedrelays are available in DIP or
SIL housing and capable to switch currents up to 0,5 A. Integrated diode
and/or electrostatic shield optional. Dielectric strength 1500 Vdc. Dimen-
sions approx. 19,3 x 7 mm board space and 5 ... 7,5 mm height for DIP or
19,8 x 5 mm board space and 7,8 mm height for SIL version.
Cradle Relays
Extremely reliable and mature relay family of 1st generation for various signal
switching applications. Available as non polarized, polarized / latching and
relay with AC coil. The benet is the possibility of combining various contact
sets from 1 up to 6 poles, single and bifurcated contacts, different contact
materials with a coil voltage range from 1,5 Vdc to 220 Vac. Cradle relays are
available as dust protected and hermetically sealed versions, with plug in or
solder terminals and are capable to switch currents up to 5 A. Forcibly guided
(linked) contact sets optional. Dielectric strength 500 Vrms. Dimensions from
approx. 19 x 24 to 19x35 mm board space and 30 mm height.
Other Relays
We offer a variety of different relay families for maintenance and replace-
ment purposes. These relays are up to 60 years old now, such as Card
Relay SN (V23030 series), Small General Purpose Relay (V23006 series),
Small Polarized Relay (V23063 ... V23067 and V23163 ... V23167 series).
Accessories like sockets, hold down springs, etc. optional.
High Frequency Relays
HF3 / HF3S / HF6 series RF relays offering excellent RF characteristics
in a small package. All HF series relays are suitable for SMD soldering
processes. Available as non latching or latching versions with 1 or 2 coils
and a nominal coil voltage range from 3 24 V, a coil power consumption
of 140 mW or 70 mW (single coil latching types).
HF3: Low cost RF relay suitable up to 3 GHz. Impedance 50 and 75 Ohm.
50 W hot switching and 50 W RF power carry capability.
Dimensions 14.6 x 7.3 x 10.3 mm.
HF3S: High performance, high power RF relay suitable up to 3 GHz,
50 W hot switching and 150 W RF power carry capability.
Dimensions 15 x 7.6 x 10.6 mm.
HF6: High performance, high power RF relay suitable up to 6 GHz,
50 W hot switching and 50 W RF power carry capability.
Dimensions 15 x 7.6 x 10.6 mm.
Telecom-, Signal and RF Relays
AXICOM
Tyco Electronics Logistics AG
Werk Axicom Au
Seestrasse 295
CH-8804 Au-Wädenswil / Switzerland
Phone +41 44 782 91 11
Fax +41 44 782 90 00
E-mail: axicom@tycoelectronics.com
Tyco Electronics
Paulsternstrasse 26
D-13629 Berlin / Germany
Phone +49 30 386 38573
Fax +49 30 386 38575
E-mail: axicom@tycoelectronics.com
Tyco Electronics EC Trutnov s.r.o.
Komenského 821
CZ-541 01 Trutnov / Czech Republic
E-mail: axicom@tycoelectronics.com
Tyco Electronics Corporation
POB 3608,
Harrisburg, PA 17105, USA
Phone +1 800-522-6752