SPECIFICATION
TS-400-112TS-400-124TS-400-148TS-400-212TS-400-224TS-400-248
20A
0.63A
21 ~ 30VDC
86%
75 5℃±
10A
0.32A
42 ~ 60VDC
87%
70 5℃±
20A
0.63A
21 ~ 30VDC
87.5%
75 5℃±
10A
0.32A
42 ~ 60VDC
88.5%
70 5℃±
MODEL
AC VOLTAGE
MAXIMUM OUTPUT POWER
WAVEFORM Note.2
OUTPUT FREQUENCY
AC REGULATION Note.2
VOLTAGE RANGE (Typ.) Note.3
EFFICIENCY (Typ.) Note.1
DC CURRENT (Typ.)
INPUT
INPUT
BATTERY
OUTPUT
ENVIRONMENT
FUSE
SAFETY &
EMC
BAT. LOW ALARM
BAT. LOW SHUTDOWN
OVER TEMPERATURE
OUTPUT SHORT
BAT. POLARITY
GFCI PROCTECTION
PROTECTION
PROTECTION
True sine wave (THD<3%)
40A
1.25A
10.5 ~ 15VDC
86%
85 5℃±
40A*2 40A*1 20A*1
20A*140A*1
±3.0% at rated input voltage
10.5 ~ 15VDC
84.5%
40A
1.25A
40A*2
85 5℃±
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor
Protection type : Shut down o/p voltage, re-power on to recover
By internal fuse open
Optional (Only type F) None
Compliance to FCC class A
None
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
SAFETY STANDARDS
-10 ~ +40 @ 100% load ; +60 @ 50% load
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RHo
Design refer to
U 458L
None
Compliance to EN61000-4-2,3,8
Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
True sine wave output (THD<3%)
High surge power up to 800W
High efficiency up to 88.5%
Thermostatically controlled cooling fan
Built-in remote ON-OFF control
Front panel indicator for operation status
Power ON-OFF switch
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input reverse polarity / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
3 years warranty
RATED POWER 400W
OVER LOAD (Typ.) 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
Features :
OTHERS
PACKING 1.73Kg; 6pcs/11.4Kg/1.55CUFT
DIMENSION 205*158*67mm (L*W*H)
NOTE 1.Efficiency is tested by 300W, linear load at 13V/26V/52V input voltage.
2.AC regulation and THD are tested by 400W, linear load at 13V/26V/52V input voltage.
3.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V
→± →± →±
4.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting.
460W for 180 sec. / 600W for 10 sec. / surge power 800W for 30 cycles(typ.)
11.3 4%±22.5 4%±45 4%±45 4%±22.5 4%±
10.5 4%±21 4%±42 4%±42 4%±21 4%±
11.3 4%±
10.5 4%±
TS-400 series
File Name:TS-400-SPEC 2015-05-27
50 0.1Hz 50/60Hz selectable by setting button±
60 0.1Hz 50/60Hz selectable by setting button±
FRONT PANEL INDICATOR Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal
24V 48V 24V 48V
BAT. VOLTAGE 12V12V
NO LOAD CURRENT DRAW (Typ.)
OFF MODE CURRENT DRAW 1mA
BATTERY TYPES Open & sealed Lead Acid
400W True Sine Wave DC-AC Power Inverter
LVD None EN60950-1
100 / 110 / 115 / 120VAC selectable by setting button S.W
Factory setting set at 110VAC
200 / 220 / 230 / 240VAC selectable by setting button S.W
Factory setting set at 230VAC
E
13
REMOTE CONTROL Open : Normal work ; Short : Remote off
FUNCTION
MTBF 104.7K hrs min. MIL-HDBK-217F (25 )
EMC IMMUNITY
EMC EMISSION
Mechanical Specification
_
_
_
ENVIRONMENT TEMPERATURE ( )
Derating Curve
Unit:mm
AC OUTPUT
Status
Setting
AC OUTPUT
Status
Setting
Type-A
Type-B
R.C Connector : JST B-XH or equivalent
Open
Short
Normal work
Remote off
File Name:TS-400-SPEC 2015-05-27
TS-400 series
True sine wave inverter 12:12VDC
24:24VDCBat. Voltage:
48:48VDC
1:110VAC
2:230VAC
Output:
O/P Wattage:400W
TS 400 112 A
400W True Sine Wave DC-AC Power Inverter
A :TYPE
B :TYPE
C :TYPE
D :TYPE
E :TYPE
F :TYPE
A
B
C
D
E
F
OUTLET
OUTLET
OUTLET
OUTLET
OUTLET
OUTLET
120
205
147
158
9
7
11
8.9
direction
Air flow
18
12
42.5
25.32
Chassis
Ground
R.C
ON
OFF
10.7
67
Reverse Polarity
Will Damage The Unit.
TYPE-A
Receptacle type
Country
Certificate
TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F
USA EUROPE AUSTRALIA U.K JAPAN GFCI
AC Output Receptacles (optional)
E
13
EE
13 13
LOAD (%)
-10 10 20 30 40 50 60 70
(HORIZONTAL)
20
40
50
60
80
100
0
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Mean Well:
TS-400-112A TS-400-148A