Single Output Isolation Transformer
Model 1604A
Data Sheet
www.bkprecision.com
Technical data subject to change
© B&K Precision Corp. 2017
v042517
The 1604A (single output) isolation transformer provides the necessary safety factor for servicing
any transformerless AC powered equipment.
Features & Benefits
Leakage: less than 0.1 mA
Output Voltage: 117 to 129 V (120 V input)
Output Current: 1.25 A continuous
Specifications 1604A
Isolation leakage less than 0.1 mA
Output Voltage (typical) 117-129 V nominal (120 V input)
Output Current 1.25 A continuous
(2 A intermittent)
Power Requirements 120 VAC, 60 Hz, 175 W
Operating Temperature 32 to 104 ˚F (0 to +40 °C)
Dimensions (HxWxD) 4” x 4” x 5.5" (100 x 100 x 140 mm)
Weight 6 lbs (2.7 kg)
One-Year Warranty
Included Accessories Instruction manual & power cord