2Specifications are subject to change without notice
SJ 135, SJ 185
Output SPDT relay
Rated insulation voltage 250 VAC (rms)
(cont./elect.)
Contact ratings (AgCdO) µ (micro gap)
Resistive loads AC 1 10 A/250 VAC (2500 VA)
DC 1 1 A/250 VDC (250 W)
or 10 A/25 VDC (250 W)
Small inductive loads AC 15 2.5 A/230 VAC
DC 13 5 A/24 VDC
Mechanical life ≥30 x 106operations
Electrical life AC 1 ≥2.5 x 105operations
(at max. load)
Operating frequency ≤7200 operations/h
Dielectric strength
Dielectric voltage ≥2 kVAC (rms) (cont./elect.)
Rated impulse withstand volt. 4 kV (1.2/50 µs) (cont./elect.)
(IEC 60664)
Power supply AC types Overvoltage cat. III (IEC 60664)
Rated operational voltage (IEC 60038)
Through pins 2 & 10 024 24 VAC ± 15%, 45 to 65 Hz
115 115 VAC ± 15%, 45 to 65 Hz
230 230 VAC ± 15%, 45 to 65 Hz
Voltage interruption ≤40 ms
Dielectric voltage ≥2 kV AC (rms) (supply/elect.)
Rated impulse withstand volt. 4 kV (1.2/50 µs) (line/neutral),
no direct connection to electr.
Power supply DC types Overvoltage cat. III (IEC 60664)
Rated operational voltage (IEC 60038)
Through pins 2 & 10 724 24 VDC ± 15%
Dielectric voltage None (supply/elect.)
Rated impulse withstand volt. 800 V (1.2/50 µs)
Rated operational power
AC supply 2.5 VA
DC supply 1.5 W
Reaction time Relay operates: τ= 22 ms
Relay releases: τ= 2.2 s,
worst case reaction time
may be up to 5 x τ
Accuracy
Input 0 to 10% on max.
Min. actual level
≤min. set level
Indication for
Output ON LED, yellow
Environment (IEC 60947-1)
Degree of protection IP 20 B (IEC 60947-1)
Pollution degree 2 (IEC 60664)
Operating temperature -2 0° to +50 °C (-4° to +122°F)
Storage temperature
-50° to +85°C (-58° to +185°F)
Weight AC supply 200 g
DC supply 125 g
Approvals UL, CSA
SJ 135
Example 1
DC voltage metering
(AC power supply)
The relay operates when the
actual voltage reaches set
point.
The relay releases when the
voltage drops min. 10% be-
low set point (see hysteresis)
or when power supply is in-
terrupted.
Example 2
DC voltage metering -
latching (AC power supply)
The relay operates and re-
mains in operating position
when the actual voltage
reaches set point.
Provided that the voltage has
dropped min. 10% below the
set point (see hysteresis) the
relay will release when the in-
terconnection between pins 8
and 9 is interrupted. The relay
also releases when power
supply is interrupted.
Example 3
AC or DC metering
(DC power supply)
Please note that pins 7 and
10 are internally connected at
DC power supply. No current
must pass through this inter-
nal connection.
Mode of Operation
SJ 185
The SJ 185 measures the ave-
rage of a sinusoidal voltage
(input). The set point, cali-
brated to rms-value, is set on
built-in potentiometer.
Example 1
AC voltage metering
(AC power supply
The relay operates when the
voltage reaches set point.
The relay releases again when
the voltage has dropped min.
10% below the set point (see
hysteresis), or when power
supply is interrupted.
Example 2
AC voltage metering -
latching
(AC Power supply)
The relay operates and re-
mains in operating position
when the voltage reaches set
point.
Provided that the voltage has
dropped min. 10% below set
point (see hysteresis) the re-
lay releases when the inter-
connection between pins 8
and 9 is interrupted. The relay
also releases when power
supply is interupted.
Example 3
AC or DC metering
(DC power supply)
Please note that pins 7 and
10 are internally connected at
DC power supply. No current
must pass through this inter-
nal connection.
Supply Specifications
Output Specifications
General Specifications