General Description:
Series 6, 18 AWG solid .040" bare copper or bare copper-covered steel conductor (see below),
gas-injected foam polyethylene insulation, Duobond® II + AL braid shield (60% coverage), PVC jacket
(black, gray or white).
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
218 Solid BCAC - Bare Copper w/Anti-Corrosion Treatment 1.02362
Total Number of Conductors: 2
Corrosion Resistance: Yes
Insulation
Insulation Material:
Insulation Material Dia. (mm)
Gas-injected FPE - Foam Polyethylene 4.572
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1Bonded Duofoil® Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100
2 Braid AL - Aluminum 60
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter: 6.934 x 15.113 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -40°C To +80°C
Non-UL Temperature Rating: 80°C
Bulk Cable Weight: 83.339 Kg/Km
Max. Recommended Pulling Tension: 1120.946 N
Min. Bend Radius/Minor Axis: 76.200 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CATV, CM
CEC/C(UL) Specification: CM
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Page 1 of 3 01-09-2015
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1841AC Coax - Series 6
Series Type: Series 6
Flame Test
UL Flame Test: UL1685 UL Loading
Plenum/Non-Plenum
Plenum (Y/N): No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm) Tolerance (Ohms)
75 ± 3
Nom. Inductance:
Inductance (µH/m)
0.318257
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
53.1522
Nominal Velocity of Propagation:
VP (%)
83
Nominal Delay:
Delay (ns/m)
3.9372
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
20.9984
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
29.529
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
51.6405
55 4.5934
211 8.5306
500 13.4521
750 16.7331
862 18.0455
1000 19.686
1450 25.5918
1800 28.2166
2250 32.1538
3000 37.0753
Max. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
52.19827
55 5.2496
211 9.41647
500 14.6989
750 18.3408
862 19.6204
1000 21.4577
1450 26.248
1800 28.8728
2250 32.81
3000 39.0439
Max. Operating Voltage - Non-UL:
Voltage
300 V RMS
Minimum Structural Return Loss:
Start Freq. (MHz) Stop Freq. (MHz) Min. SRL (dB)
950 2250 15
2250 3000 10
Sweep Test
Page 2 of 3 01-09-2015
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1841AC Coax - Series 6
Sweep Testing: 950 MHz - 3 GHz
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
1841AC 008500 500 FT 32.500 LB GRAY C DUAL#18 LDPE/GIFHDLDPE SHFRPVC
1841AC 009500 500 FT 32.500 LB WHITE C DUAL#18 LDPE/GIFHDLDPE SHFRPVC
1841AC 0101000 1,000 FT 63.000 LB BLACK C DUAL#18 LDPE/GIFHDLDPE SHFRPVC
1841AC 010500 500 FT 32.500 LB BLACK C DUAL#18 LDPE/GIFHDLDPE SHFRPVC
Notes:
C = CRATE REEL PUT-UP.
Revision Number: 3 Revision Date: 10-04-2012
© 2015 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 01-09-2015
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1841AC Coax - Series 6