IRS210614S
www.irf.com © 2008 International Rectifier
7
PRELIMINARY
Static Electrical Characteristics
VBIAS (VCC, VBS) = 14 V, CT = 1 nF and TA = 25 °C unless otherwise specified. The VO and IO parameters
are referenced to COM and are applicable to the respective output leads: HO or LO.
CLO1=CLO2=CHO1=CHO2=1 nF.
Symbol Definition Min Typ Max Units
Test Conditions
Low Voltage Supply Characteristic s
VIH Logic “1” input voltage 2.5 — —
VIL Logic “0” input voltage — — 0.8 V VCC = 10 V to 20V
VOH High level output voltage, VBIAS -VO — 0.05 0.2
VOL Low level output voltage, VO — 0.02 0.1
Io = 2 mA
ILK Offset supply leakage current — — 50 VB = VS = 600 V
IQBS Quiescent VBS supply current 20 75 130
IQCC Quiescent VCC supply current 60 120 180 VIN = 0 V or 5V
IIN+ Logic “1” input bias cu rrent VIN = 5 V — 5 20
IIN- Logic “0” input bias cu rrent VIN = 0 V — — 5
µA
VCCUV+
VBSUV VCC and VBS supply undervoltage
positive going threshold 8.0 8.9 9.8
VCCUV-
VBSUV- VCC and VBS supply undervoltage
negative going threshold 7.4 8.2 9.0
VCCUVH
VBSUVH Hysteresis 0.3 0.7 —
V
Io+ Output high short circuit pulsed current 130 290 — VO = 0 V,
PW ≤ 10 µs
Io- Output low short circuit pulsed current 270 600 — mA VO = 15 V,
PW ≤ 10 µs
Dynamic Electrical Characteristics
VBIAS (VCC, VBS) = 15 V, VSS = COM, CL = 1000 pF, TA = 25 °C.
Symbol Component Min. Typ. Max. Units Test Conditions
ton Turn-on propagation delay --- 165 230 VS = 0 V
toff Turn-off propagation delay --- 165 230 VS = 0 V or 600 V
MT Delay matching, HS & LS turn-on/off --- 0 30
tr Turn-on rise time --- 100 220
tf Turn-off fall time --- 35 80
ns
VS = 0 V
Not recommended for new designs. For new designs, we recommend IRS21064SPBF or 2EDL05N06PJ