DP8420A,DP8421A,DP8422A
DP8420A DP8421A DP8422A microCMOS Programmable 256k/1M/4M Dynamic RAM
Controller/Drivers
Literature Number: SNOSBX7A
TL/F/8588
DP8420A/21A/22A microCMOS Programmable 256k/1M/4M Dynamic RAM Controller/Drivers
July 1992
DP8420A/21A/22A microCMOS Programmable
256k/1M/4M Dynamic RAM Controller/Drivers
General Description
The DP8420A/21A/22A dynamic RAM controllers provide a
low cost, single chip interface between dynamic RAM and
all 8-, 16- and 32-bit systems. The DP8420A/21A/22A gen-
erate all the required access control signal timing for
DRAMs. An on-chip refresh request clock is used to auto-
matically refresh the DRAM array. Refreshes and accesses
are arbitrated on chip. If necessary, a WAIT or DTACK out-
put inserts wait states into system access cycles, including
burst mode accesses. RAS low time during refreshes and
RAS precharge time after refreshes and back to back ac-
cesses are guaranteed through the insertion of wait states.
Separate on-chip precharge counters for each RAS output
can be used for memory interleaving to avoid delayed back
to back accesses because of precharge. An additional fea-
ture of the DP8422A is two access ports to simplify dual
accessing. Arbitration among these ports and refresh is
done on chip.
Features
YOn chip high precision delay line to guarantee critical
DRAM access timing parameters
YmicroCMOS process for low power
YHigh capacitance drivers for RAS, CAS,WEand DRAM
address on chip
YOn chip support for nibble, page and static column
DRAMs
YByte enable signals on chip allow byte writing in a word
size up to 32 bits with no external logic
YSelection of controller speeds: 20 MHz and 25 MHz
YOn board Port A/Port B (DP8422A only)/refresh arbitra-
tion logic
YDirect interface to all major microprocessors (applica-
tion notes available)
Y4 RAS and 4 CAS drivers (the RAS and CAS configura-
tion is programmable)
Ýof Pins Ýof Address Largest Direct Drive Access
Control (PLCC) Outputs DRAM Memory Ports
Possible Capacity Available
DP8420A 68 9 256 kbit 4 Mbytes Single Access Port
DP8421A 68 10 1 Mbit 16 Mbytes Single Access Port
DP8422A 84 11 4 Mbit 64 Mbytes Dual Access Ports (A and B)
Block Diagram
DP8420A/21A/22A DRAM Controller
TL/F/85885
FIGURE 1
TRI-STATEÉis a registered trademark of National Semiconductor Corporation.
Staggered RefreshTM is a trademark of National Semiconductor Corporation.
C1995 National Semiconductor Corporation RRD-B30M105/Printed in U. S. A.
Obsolete
Table of Contents
1.0 INTRODUCTION
2.0 SIGNAL DESCRIPTIONS
2.1 Address, R/W and Programming Signals
2.2 DRAM Control Signals
2.3 Refresh Signals
2.4 Port A Access Signals
2.5 Port B Access Signals (DP8422A)
2.6 Common Dual Port Signals (DP8422A)
2.7 Power Signals and Capacitor Input
2.8 Clock Inputs
3.0 PROGRAMMING AND RESETTING
3.1 External Reset
3.2 Programming Methods
3.2.1 Mode Load Only Programming
3.2.2 Chip Selected Access Programming
3.3 Internal Programming Modes
4.0 PORT A ACCESS MODES
4.1 Access Mode 0
4.2 Access Mode 1
4.3 Extending CAS with Either Access Mode
4.4 Read-Modify-Write Cycles with Either Access Mode
4.5 Additional Access Support Features
4.5.1 Address Latches and Column Increment
4.5.2 Address Pipelining
4.5.3 Delay CAS During Write Accesses
5.0 REFRESH OPTIONS
5.1 Refresh Control Modes
5.1.1 Automatic Internal Refresh
5.1.2 Externally Controlled/Burst Refresh
5.1.3 Refresh Request/Acknowledge
5.2 Refresh Cycle Types
5.2.1 Conventional Refresh
5.2.2 Staggered RefreshTM
5.2.3 Error Scrubbing Refresh
5.3 Extending Refresh
5.4 Clearing the Refresh Address Counter
5.5 Clearing the Refresh Request Clock
6.0 PORT A WAIT STATE SUPPORT
6.1 WAIT Type Output
6.2 DTACK Type Output
6.3 Dynamically Increasing the Number of Wait States
6.4 Guaranteeing RAS Low Time and RAS Precharge
Time
7.0 RAS AND CAS CONFIGURATION MODES
7.1 Byte Writing
7.2 Memory Interleaving
7.3 Address Pipelining
7.4 Error Scrubbing
7.5 Page/Burst Mode
8.0 TEST MODE
9.0 DRAM CRITICAL TIMING PARAMETERS
9.1 Programmable Values of tRAH and tASC
9.2 Calculation of tRAH and tASC
10.0 DUAL ACCESSING (DP8422A)
10.1 Port B Access Mode
10.2 Port B Wait State Support
10.3 Common Port A and Port B Dual Port Functions
10.3.1 GRANTB Output
10.3.2 LOCK Input
11.0 ABSOLUTE MAXIMUM RATINGS
12.0 DC ELECTRICAL CHARACTERISTICS
13.0 AC TIMING PARAMETERS
14.0 FUNCTIONAL DIFFERENCES BETWEEN THE
DP8420A/21A/22A AND THE DP8420/21/22
15.0 DP8420A/21A/22A USER HINTS
2
Obsolete
1.0 Introduction
The DP8420A/21A/22A are CMOS Dynamic RAM control-
lers that incorporate many advanced features which include
address latches, refresh counter, refresh clock, row, column
and refresh address multiplexer, delay line, refresh/access
arbitration logic and high capacitive drivers. The program-
mable system interface allows any manufacturer’s micro-
processor or bus to directly interface via the
DP8420A/21A/22A to DRAM arrays up to 64 Mbytes in
size.
After power up, the user must first reset and program the
DP8420A/21A/22A before accessing the DRAM. The chip
is programmed through the address bus.
Reset:
Due to the differences in power supplies, the internal reset
circuit may not always reset correctly; therefore, an External
(hardware) Reset must be performed before programming
the chip.
Programming:
After resetting the chip, the user can program the controller
by either one of two methods: Mode Load Only Program-
ming or Chip Select Access Programming.
Initialization Period:
Once the DP8420A/21A/22A has been programmed for the
first time, a 60 ms initialization period is entered. During this
time the DRC performs refreshes to the DRAM array so
further warm up cycles are unnecessary. The initialization
period is entered only after the first programming after a
reset.
Accessing Modes:
After resetting and programming the chip, the
DP8420A/21A/22A is ready to access the DRAM. There
are two modes of accessing with these controllers. Mode 0,
which indicates RAS synchronously and Mode 1, which indi-
cates RAS asynchronously.
Refresh Modes:
The DP8420A/21A/22A have expanded refresh capabilities
compared to previous DRAM controllers. There are three
modes of refreshing available: Internal Automatic Refresh-
ing, Externally Controlled/Burst Refreshing and Refresh Re-
quest/Acknowledge Refreshing. Any of these modes can
be used together or separately to achieve the desired re-
sults.
Refresh Types:
These controllers have three types of refreshing available:
Conventional, Staggered and Error Scrubbing. Any refresh
control mode can be used with any type of refresh.
Wait Support:
The DP8420A/21A/22A have wait support available as
DTACK or WAIT. Both are programmable. DTACK, Data
Transfer ACKnowledge, is useful for processors whose wait
signal is active high. WAIT is useful for those processors
whose wait signal is active low. The user can choose either
at programming. These signals are used by the on chip arbi-
ter to insert wait states to guarantee the arbitration between
accesses, refreshes and precharge. Both signals are inde-
pendent of the access mode chosen and both signals can
be dynamically delayed further through the WAITIN signal to
the DP8420A/21A/22A.
Sequential Accesses (Static Column/Page Mode):
The DP8420A/21A/22A have address latches, used to
latch the bank, row and column address inputs. Once the
address is latched, a COLumn INCrement (COLINC) feature
can be used to increment the column address. The address
latches can also be programmed to be fall through. COLINC
can be used for Sequential Accesses of Static Column
DRAMs. Also, COLINC in conjunction with ECAS inputs can
be used for Sequential Accesses to Page Mode DRAMs.
RAS and CAS Configuration (Byte Writing):
The RAS and CAS drivers can be configured to drive a one,
two or four bank memory array up to 32 bits in width. The
ECAS signals can then be used to select one of four CAS
drivers for Byte Writing with no extra logic.
Memory Interleaving:
When configuring the DP820A/21A/22A for more than one
bank, Memory Interleaving can be used. By tying the low
order address bits to the bank select lines B0 and B1, se-
quential back to back accesses will not be delayed since
these controllers have separate precharge counters per
bank.
Address Pipelining:
The DP8420A/21A/22A are capable of performing Address
Pipelining. In address pipelining, the DRC will guarantee the
column address hold time and switch the internal multiple-
xor to place the row address on the address bus. At this
time, another memory access to another bank can be initiat-
ed.
Dual Accessing:
Finally, the DP8422A has all the features previously men-
tioned and unlike the DP8420A/21A, the DP8422A has a
second port to allow a second CPU to access the same
memory array. The DP8422A has four signals to support
Dual Accessing, these signals are AREQB, ATACKB, LOCK
and GRANTB. All arbitration for the two ports and refresh is
done on chip by the controller through the insertion of wait
states. Since the DP8422A has only one input address bus,
the address lines must be multiplexed externally. The signal
GRANTB can be used for this purpose.
Terminology:
The following explains the terminology used in this data
sheet. The terms negated and asserted are used. Asserted
refers to a ‘‘true’’ signal. Thus, ‘‘ECAS0 asserted’’ means
the ECAS0 input is at a logic 0. The term ‘‘COLINC assert-
ed’’ means the COLINC input is at a logic 1. The term negat-
ed refers to a ‘‘false’’ signal. Thus, ‘‘ECAS0 negated’’
means the ECAS0 input is at a logic 1. The term ‘‘COLINC
negated’’ means the input COLINC is at a logic 0. The table
shown below clarifies this terminology.
Signal Action Logic Level
Active High Asserted High
Active High Negated Low
Active Low Asserted Low
Active Low Negated High
3
Obsolete
Connection Diagrams
TL/F/85884
Top View
FIGURE 2
Order Number DP8420AV-20 or DP8420AV-25
See NS Package Number V68A
TL/F/85883
Top View
FIGURE 3
Order Number DP8421AV-20 or DP8421AV-25
See NS Package Number V68A
TL/F/85882
Top View
FIGURE 4
Order Number DP8422AV-20 or DP8422AV-25
See NS Package Number V84A
4
Obsolete
2.0 Signal Descriptions
Pin Device (If not Input/ Description
Name Applicable to All) Output
2.1 ADDRESS, R/W AND PROGRAMMING SIGNALS
R0 10 DP8422A I ROW ADDRESS: These inputs are used to specify the row address during an access
to the DRAM. They are also used to program the chip when ML is asserted (except
R0 9 DP8420A/21A I
R10).
C0 10 DP8422A I COLUMN ADDRESS: These inputs are used to specify the column address during an
access to the DRAM. They are also used to program the chip when ML is asserted
C0 9 DP8420A/21A I
(except C10).
B0, B1 I BANK SELECT: Depending on programming, these inputs are used to select a group
of RAS and CAS outputs to assert during an access. They are also used to program
the chip when ML is asserted.
ECAS0–3 I ENABLE CAS: These inputs are used to enable a single or group of CAS outputs
when asserted. In combination with the B0, B1 and the programming bits, these
inputs select which CAS output or CAS outputs will assert during an access. The
ECAS signals can also be used to toggle a group of CAS outputs for page/nibble
mode accesses. They also can be used for byte write operations. If ECAS0is
negated during programming, continuing to assert the ECAS0 while negating AREQ
or AREQB during an access, will cause the CAS outputs to be extended while the
RAS outputs are negated (the ECASn inputs have no effect during scrubbing
refreshes).
WIN I WRITE ENABLE IN: This input is used to signify a write operation to the DRAM. If
ECAS0 is asserted during programming, the WE output will follow this input. This
input asserted will also cause CAS to delay to the next positive clock edge if address
bit C9 is asserted during programming.
COLINC I COLUMN INCREMENT: When the address latches are used, and RFIP is negated,
this input functions as COLINC. Asserting this signal causes the column address to
(EXTNDRF) I
be incremented by one. When RFIP is asserted, this signal is used to extend the
refresh cycle by any number of periods of CLK until it is negated.
ML I MODE LOAD: This input signal, when low, enables the internal programming register
that stores the programming information.
2.2 DRAM CONTROL SIGNALS
Q0 10 DP8422A O DRAM ADDRESS: These outputs are the multiplexed output of the R0 9, 10 and
C0 9, 10 and form the DRAM address bus. These outputs contain the refresh
Q0 9 DP8421A O
address whenever RFIP is asserted. They contain high capacitive drivers with 20X
Q0 8 DP8421A O series damping resistors.
RAS0–3 O ROW ADDRESS STROBES: These outputs are asserted to latch the row address
contained on the outputs Q0 8, 9, 10 into the DRAM. When RFIP is asserted, the
RAS outputs are used to latch the refresh row address contained on the Q0 8, 9, 10
outputs in the DRAM. These outputs contain high capacitive drivers with 20Xseries
damping resistors.
CAS0–3 O COLUMN ADDRESS STROBES: These outputs are asserted to latch the column
address contained on the outputs Q0 8, 9, 10 into the DRAM. These outputs have
high capacitive drivers with 20Xseries damping resistors.
WE O WRITE ENABLE or REFRESH REQUEST: This output asserted specifies a write
operation to the DRAM. When negated, this output specifies a read operation to the
(RFRQ)O
DRAM. When the DP8420A/21A/22A is programmed in address pipelining mode or
when ECAS0 is negated during programming, this output will function as RFRQ.
When asserted, this pin specifies that 13 msor15ms have passed. If DISRFSH is
negated, the DP8420A/21A/22A will perform an internal refresh as soon as possible.
If DISRFRSH is asserted, RFRQ can be used to externally request a refresh through
the input RFSH. This output has a high capacitive driver and a 20Xseries damping
resistor.
5
Obsolete
2.0 Signal Descriptions (Continued)
Pin Device (If not Input/ Description
Name Applicable to All) Output
2.3 REFRESH SIGNALS
RFIP O REFRESH IN PROGRESS: This output is asserted prior to a refresh cycle and is
negated when all the RAS outputs are negated for that refresh.
RFSH I REFRESH: This input asserted with DISRFRSH already asserted will request a
refresh. If this input is continually asserted, the DP8420A/21A/22A will perform
refresh cycles in a burst refresh fashion until the input is negated. If RFSH is asserted
with DISRFSH negated, the internal refresh address counter is cleared (useful for
burst refreshes).
DISRFSH I DISABLE REFRESH: This input is used to disable internal refreshes and must be
asserted when using RFSH for externally requested refreshes.
2.4 PORT A ACCESS SIGNALS
ADS I ADDRESS STROBE or ADDRESS LATCH ENABLE: Depending on programming,
this input can function as ADS or ALE. In mode 0, the input functions as ALE and
(ALE) I
when asserted along with CS causes an internal latch to be set. Once this latch is set
an access will start from the positive clock edge of CLK as soon as possible. In Mode
1, the input functions as ADS and when asserted along with CS, causes the access
RAS to assert if no other event is taking place. If an event is taking place, RAS will be
asserted from the positive edge of CLK as soon as possible. In both cases, the low
going edge of this signal latches the bank, row and column address if programmed to
do so.
CS I CHIP SELECT: This input signal must be asserted to enable a Port A access.
AREQ I ACCESS REQUEST: This input signal in Mode 0 must be asserted some time after
the first positive clock edge after ALE has been asserted. When this signal is
negated, RAS is negated for the access. In Mode 1, this signal must be asserted
before ADS can be negated. When this signal is negated, RAS is negated for the
access.
WAIT O WAIT or DTACK: This output can be programmed to insert wait states into a CPU
access cycle. With R7 negated during programming, the output will function as a
(DTACK)O
WAIT type output. In this case, the output will be active low to signal a wait condition.
With R7 asserted during programming, the output will function as DTACK. In this
case, the output will be negated to signify a wait condition and will be asserted to
signify the access has taken place. Each of these signals can be delayed by a
number of positive clock edges or negative clock levels of CLK to increase the
microprocessor’s access cycle through the insertion of wait states.
WAITIN I WAIT INCREASE: This input can be used to dynamically increase the number of
positive clock edges of CLK until DTACK will be asserted or WAIT will be negated
during a DRAM access.
6
Obsolete
2.0 Signal Descriptions (Continued)
Pin Device (If not Input/ Description
Name Applicable to All) Output
2.5 PORT B ACCESS SIGNALS
AREQB DP8422A I PORT B ACCESS REQUEST: This input asserted will latch the row, column and bank
address if programmed, and requests an access to take place for Port B. If the
only
access can take place, RAS will assert immediately. If the access has to be delayed,
RAS will assert as soon as possible from a positive edge of CLK.
ATACKB DP8422A O ADVANCED TRANSFER ACKNOWLEDGE PORT B: This output is asserted when
the access RAS is asserted for a Port B access. This signal can be used to generate
only
the appropriate DTACK or WAIT type signal for Port B’s CPU or bus.
2.6 COMMON DUAL PORT SIGNALS
GRANTB DP8422A O GRANT B: This output indicates which port is currently granted access to the DRAM
array. When GRANTB is asserted, Port B has access to the array. When GRANTB is
only
negated, Port A has access to the DRAM array. This signal is used to multiplex the
signals R0 8, 9, 10; C0 8, 9, 10; B0 1; WIN; LOCK and ECAS0 3 to the DP8422A
when using dual accessing.
LOCK DP8422A I LOCK: This input can be used by the currently granted port to ‘‘lock out’’ the other
port from the DRAM array by inserting wait states into the locked out port’s access
only
cycle until LOCK is negated.
2.7 POWER SIGNALS AND CAPACITOR INPUT
VCC IPOWER: Supply Voltage.
GND I GROUND: Supply Voltage Reference.
CAP I CAPACITOR: This input is used by the internal PLL for stabilization. The value of the
ceramic capacitor should be 0.1 mF and should be connected between this input and
ground.
2.8 CLOCK INPUTS
There are two clock inputs to the DP8420A/21A/22A, CLK and DELCLK. These two clocks may both be tied to the same clock
input, or they may be two separate clocks, running at different frequencies, asynchronous to each other.
CLK I SYSTEM CLOCK: This input may be in the range of 0 Hz up to 25 MHz. This input is
generally a constant frequency but it may be controlled externally to change
frequencies or perhaps be stopped for some arbitrary period of time.
This input provides the clock to the internal state machine that arbitrates between
accesses and refreshes. This clock’s positive edges and negative levels are used to
extend the WAIT (DTACK) signals. Ths clock is also used as the reference for the
RAS precharge time and RAS low time during refresh.
All Port A and Port B accesses are assumed to be synchronous to the system clock
CLK.
DELCLK I DELAY LINE CLOCK: The clock input DELCLK, may be in the range of 6 MHz to
20 MHz and should be a multiple of 2 (i.e., 6, 8, 10, 12, 14, 16, 18, 20 MHz) to have
the DP8420A/21A/22A switching characteristics hold. If DELCLK is not one of the
above frequencies the accuracy of the internal delay line will suffer. This is because
the phase locked loop that generates the delay line assumes an input clock
frequency of a multiple of 2 MHz.
For example, if the DELCLK input is at 7 MHz and we choose a divide by 3 (program
bits C0 2) this will produce 2.333 MHz which is 16.667% off of 2 MHz. Therefore, the
DP8420A/21A/22A delay line would produce delays that are shorter (faster delays)
than what is intended. If divide by 4 was chosen the delay line would be longer
(slower delays) than intended (1.75 MHz instead of 2 MHz). (See Section 10 for more
information.)
This clock is also divided to create the internal refresh clock.
7
Obsolete
3.0 Programming and Resetting
Due to the variety in power supplies power-up times, the
internal power up reset circuit may not work in every design;
therefore, an EXTERNAL RESET must be performed before
the DRAM controller can be programmed and used.
After going through the reset procedure, the
DP8420A/21A/22A can be programmed by either of two
methods; Mode Load Only Programming or Chip Select Ac-
cess Programming. After programming the DRC for the first
time after reset, the chip enters a 60 ms initialization period,
during this period the controller performs refreshes every
13 msor15ms, this makes further DRAM warm up cycles
unnecessary. After this stage the chip can be repro-
grammed as many times as the user wishes and the 60 ms
period will not be entered into unless the chip is reset and
programmed again.
During the 60 ms initialization period, RFIP is asserted low
and RAS toggles every 13 msor15ms depending on the
programming bit for refresh (C3). CAS will be inactive (logic
1) and the ‘‘Q’’ outputs will count from 0 to 2047 refreshing
the entire DRAM array. The actual initialization time period
is given by the following formula. T e4096*(Clock Divisor
Select)*(Refresh Clock Fine Tune)/(DELCLK Frq.)
3.1 EXTERNAL RESET
At power up, if the internal power up reset worked, all inter-
nal latches and flip-flops are cleared and the part is ready to
be programmed. The power up state can also be achieved
by performing an External Reset, which is required to insure
proper operation. External Reset is achieved by asserting
ML and DISRFSH for at least 16 positive clock edges. In
order to perform simply a Reset, the ML signal must be
negated before DISRFSH is negated as shown in
Figure 5a
.
This procedure will only reset the controller which now is
ready for programming.
While performing an External Reset, if the user negates
DISRFSH at least one clock period before negating ML,as
shown in
Figure 5b
,MLnegated will program the
DP8420A/21A/22A with the values in R0 9, C0 9, B0 1
and ECAS0. The 60 ms initialization period will be entered
since it is the first programming after reset. This is a good
way of resetting and programming the part at the same time.
Make sure the right programming bits are on the address
lines before ML is negated.
The DRC may be Reset and programmed any time on the
fly, but the user must make sure that No Access or Refresh
is in progress.
TL/F/8588E1
FIGURE 5a. Chip Reset but Not Programmed
TL/F/8588E2
FIGURE 5b. Chip Reset and Programmed
8
Obsolete
3.0 Programming and Resetting (Continued)
3.2 PROGRAMMING METHODS
3.2.1 Mode Load Only Programming
To use this method the user asserts ML enabling the inter-
nal programming register. After ML is asserted, a valid pro-
gramming selection is placed on the address bus, B0, B1
and ECAS0 inputs, then ML is negated. When ML is negat-
ed the programming bits are latched into the internal pro-
gramming register and the DP8420A/21A/22A is pro-
grammed, see
Figure 6
. When programming the chip, the
controller must not be refreshing, RFIP must be high (1) to
have a successful programming.
3.2.2 Chip Selected Access Programming
The chip can also be programmed by performing a chip
selected access. To program the chip using this method,
ML is asserted, then CS is asserted and a valid program-
ming selection is placed on the address bus. When AREQ is
asserted, the programming bits affecting the wait logic be-
come effective immediately, then DTACK is asserted allow-
ing the access to terminate. After the access, ML is negated
and the rest of the programming bits take effect.
TL/F/8588G3
FIGURE 6. ML Only Programming
TL/F/8588G4
FIGURE 7. CS Access Programming
9
Obsolete
3.0 Programming and Resetting (Continued)
3.3 PROGRAMMING BIT DEFINITIONS
Symbol Description
ECAS0 Extend CAS/Refresh Request Select
0 The CASn outputs will be negated with the RASn outputs when AREQ (or AREQB, DP8422A only) is negated.
The WE output pin will function as write enable.
1 The CASn outputs will be negated, during an acccess (Port A (or Port B, DP8422A only)) when their
corresponding ECASn inputs are negated. This feature allows the CAS outputs to be extended beyond the RAS
outputs negating. Scrubbing refreshes are NOT affected. During scrubbing refreshes the CAS outputs will negate
along with the RAS outputs regardless of the state of the ECAS inputs.
The WE output will function as ReFresh ReQuest (RFRQ) when this mode is programmed.
B1 Access Mode Select
0ACCESS MODE 0: ALE pulsing high sets an internal latch. On the next positive edge of CLK, the access (RAS)
will start. AREQ will terminate the access.
1ACCESS MODE 1: ADS asserted starts the access (RAS) immediately. AREQ will terminate the access.
B0 Address Latch Mode
0 ADS or ALE asserted for Port A or AREQB asserted for Port B with the appropriate GRANT latch the input row,
column and bank address.
1 The row, column and bank latches are fall through.
C9 Delay CAS during WRITE Accesses
0 CAS is treated the same for both READ and WRITE accesses.
1 During WRITE accesses, CAS will be asserted by the event that occurs last: CAS asserted by the internal delay
line or CAS asserted on the positive edge of CLK after RAS is asserted.
C8 Row Address Hold Time
0 Row Address Hold Time e25 ns minimum
1 Row Address Hold Time e15 ns minimum
C7 Column Address Setup Time
0 Column Address Setup Time e10 ns miniumum
1 Column Address Setup Time e0 ns minimum
C6, C5, C4 RAS and CAS Configuration Modes/Error Scrubbing during Refresh
0, 0, 0 RAS0 3 and CAS0 3 are all selected during an access. ECASn must be asserted for CASn to be asserted.
B0 and B1 are not used during an access. Error scrubbing during refresh.
0, 0, 1 RAS and CAS pairs are selected during an access by B1. ECASn must be asserted for CASn to be asserted.
B1 e0 during an access selects RAS0 1 and CAS0–1.
B1 e1 during an access selects RAS2 3 and CAS2–3.
B0 is not used during an Access.
Error scrubbing during refresh.
0, 1, 0 RAS and CAS singles are selected during an access by B0 1. ECASn must be asserted for CASn to be asserted.
B1 e0, B0 e0 during an access selects RAS0 and CAS0.
B1 e0, B0 e1 during an access selects RAS1 and CAS1.
B1 e1, B0 e0 during an access selects RAS2 and CAS2.
B1 e1, B0 e1 during an access selects RAS3 and CAS3.
Error scrubbing during refresh.
0, 1, 1 RAS0 3 and CAS0 3 are all selected during an access. ECASn must be asserted for CASn to be asserted.
B1, B0 are not used during an access.
No error scrubbing. (RAS only refreshing)
1, 0, 0 RAS pairs are selected by B1. CAS0 3 are all selected. ECASn must be asserted for CASn to be asserted.
B1 e0 during an access selects RAS0 1 and CAS0–3.
B1 e1 during an access selects RAS2 3 and CAS0–3.
B0 is not used during an access.
No error scrubbing.
10
Obsolete
3.0 Programming and Resetting (Continued)
3.3 PROGRAMMING BIT DEFINITIONS (Continued)
Symbol Description
C6, C5, C4 RAS and CAS Configuration Modes (Continued)
1, 0, 1 RAS and CAS pairs are selected by B1. ECASn must be asserted for CASn to be asserted.
B1 e0 during an access selects RAS0 1 and CAS0–1.
B1 e1 during an access selects RAS2 3 and CAS2–3.
B0 is not used during an access.
No error scrubbing.
1, 1, 0 RAS singles are selected by B0 1. CAS0 3 are all selected. ECASn must be asserted for CASntobe
asserted.
B1 e0, B0 e0 during an access selects RAS0 and CAS0–3.
B1 e0, B0 e1 during an access selects RAS1 and CAS0–3.
B1 e1, B0 e0 during an access selects RAS2 and CAS0–3.
B1 e1, B0 e1 during an access selects RAS3 and CAS0–3.
No error scrubbing.
1, 1, 1 RAS and CAS singles are selected by B0, 1. ECASn must be asserted for CASn to be asserted.
B1 e0, B0 e0 during an access selects RAS0 and CAS0.
B1 e0, B0 e1 during an access selects RAS1 and CAS1.
B1 e1, B0 e0 during an access selects RAS2 and CAS2.
B1 e1, B0 e1 during an access selects RAS3 and CAS3.
No error scrubbing.
C3 Refresh Clock Fine Tune Divisor
0 Divide delay line/refresh clock further by 30 (If DELCLK/Refresh Clock Clock Divisor e2 MHz e15 ms
refresh period).
1 Divide delay line/refresh clock further by 26 (If DELCLK/Refresh Clock Clock Divisor e2 MHz e13 ms
refresh period).
C2, C1, C0 Delay Line/Refresh Clock Divisor Select
0, 0, 0 Divide DELCLK by 10 to get as close to 2 MHz as possible.
0, 0, 1 Divide DELCLK by 9 to get as close to 2 MHz as possible.
0, 1, 0 Divide DELCLK by 8 to get as close to 2 MHz as possible.
0, 1, 1 Divide DELCLK by 7 to get as close to 2 MHz as possible.
1, 0, 0 Divide DELCLK by 6 to get as close to 2 MHz as possible.
1, 0, 1 Divide DELCLK by 5 to get as close to 2 MHz as possible.
1, 1, 0 Divide DELCLK by 4 to get as close to 2 MHz as possible.
1, 1, 1 Divide DELCLK by 3 to get as close to 2 MHz as possible.
R9 Refresh Mode Select
0 RAS0 3 will all assert and negate at the same time during a refresh.
1 Staggered Refresh. RAS outputs during refresh are separated by one positive clock edge. Depending on the
configuration mode chosen, either one or two RASs will be asserted.
R8 Address Pipelining Select
0 Address pipelining is selected. The DRAM controller will switch the DRAM column address back to the row
address after guaranteeing the column address hold time.
1 Non-address pipelining is selected. The DRAM controller will hold the column address on the DRAM address
bus until the access RASs are negated.
R7 WAIT or DTACK Select
0 WAIT type output is selected.
1 DTACK (Data Transfer ACKnowledge) type output is selected.
R6 Add Wait States to the Current Access if WAITIN is Low
0 WAIT or DTACK will be delayed by one additional positive edge of CLK.
1 WAIT or DTACK will be delayed by two additional positive edges of CLK.
11
Obsolete
3.0 Programming and Resetting (Continued)
3.3 PROGRAMMING BIT DEFINITIONS (Continued)
Symbol Description
R5, R4 WAIT/DTACK during Burst (See Section 5.1.2 or 5.2.2)
0, 0 NO WAIT STATES; If R7 e0 during programming, WAIT will remain negated during burst portion of access.
If R7 e1 programming, DTACK will remain asserted during burst portion of access.
0, 1 1T; If R7 e0 during programming, WAIT will assert when the ECAS inputs are negated with AREQ asserted.
WAIT will negate from the positive edge of CLK after the ECASs have been asserted.
If R7 e1 during programming, DTACK will negate when the ECAS inputs are negated with AREQ asserted.
DTACK will assert from the positive edge of CLK after the ECASs have been asserted.
1, 0 (/2T; If R7 e0 during programming, WAIT will assert when the ECAS inputs are negated with AREQ asserted.
WAIT will negate on the negative level of CLK after the ECASs have been asserted.
If R7 e1 during programming, DTACK will negate when the ECAS inputs are negated with AREQ asserted.
DTACK will assert from the negative level of CLK after the ECASs have been asserted.
1, 1 0T; If R7 e0 during programming, WAIT will assert when the ECAS inputs are negated. WAIT will negate when
the ECAS inputs are asserted.
If R7 e1 during programming, DTACK will negate when the ECAS inputs are negated. DTACK will assert when
the ECAS inputs are asserted.
R3, R2 WAIT/DTACK Delay Times (See Section 5.1.1 or 5.2.1)
0, 0 NO WAIT STATES; If R7 e0 during programming, WAIT will remain high during non-delayed accesses. WAIT
will negate when RAS is negated during delayed accesses.
NO WAIT STATES; If R7 e1 during programming, DTACK will be asserted when RAS is asserted.
0, 1 (/2T; If R7 e0 during programming, WAIT will negate on the negative level of CLK, after the access RAS.
1T; If R7 e1 during programming, DTACK will be asserted on the positive edge of CLK after the access RAS.
1, 0 NO WAIT STATES, (/2T; If R7 e0 during programming, WAIT will remain high during non-delayed accesses.
WAIT will negate on the negative level of CLK, after the access RAS, during delayed accesses.
(/2T; If R7 e1 during programming, DTACK will be asserted on the negative level of CLK after the access RAS.
1, 1 1T; If R7 e0 during programming, WAIT will negate on the positive edge of CLK after the access RAS.
1(/2T; If R7 e1 during programming, DTACK will be asserted on the negative level of CLK after the positive edge
of CLK after the access RAS.
R1, R0 RAS Low and RAS Precharge Time
0, 0 RAS asserted during refresh e2 positive edges of CLK.
RAS precharge time e1 positive edge of CLK.
RAS will start from the first positive edge of CLK after GRANTB transitions (DP8422A).
0, 1 RAS asserted during refresh e3 positive edges of CLK.
RAS precharge time e2 positive edges of CLK.
RAS will start from the second positive edge of CLK after GRANTB transitions (DP8422A).
1, 0 RAS asserted during refresh e2 positive edges of CLK.
RAS precharge time e2 positive edges of CLK.
RAS will start from the first positive edge of CLK after GRANTB transitions (DP8422A).
1, 1 RAS asserted during refresh e4 positive edges of CLK.
RAS precharge time e3 positive edges of CLK.
RAS will start from the second positive edge of CLK after GRANTB transitions (DP8422A).
12
Obsolete
4.0 Port A Access Modes
The DP8420A/21A/22A have two general purpose access
modes. Mode 0 RAS synchronous and Mode 1 RAS asyn-
chronous. One of these modes is selected at programming
through the B1 input. A Port A access to DRAM is initiated
by two input signals: ADS (ALE) and CS. The access is al-
ways terminated by one signal: AREQ. These input signals
should be synchronous to the input clock.
4.1 ACCESS MODE 0
Mode 0, synchronous access, is selected by negating the
input B1 during programming (B1e0). To initiate a Mode 0
access, ALE is pulse high and CS is asserted. If precharge
time was met, a refresh of DRAM or a Port B access was
not in progress, the RAS (RASs) would be asserted on the
first rising edge of clock. If a refresh or a Port B access is in
progress or precharge time is required, the controller will
wait until these events have taken place and assert RAS
(RASs) on the next positive edge of clock.
Sometime after the first positive edge of clock after ALE and
CS have been asserted, the input AREQ must be asserted.
In single port applications, once AREQ is asserted, CS can
be negated. On the other hand, ALE can stay asserted sev-
eral periods of clock; however, ALE must be negated before
or during the period of CLK in which AREQ is negated.
The controller samples AREQ on the every rising edge of
clock after DTACK is asserted. The access will end when
AREQ is sampled negated.
TL/F/858860
FIGURE 8a. Access Mode 0
13
Obsolete
4.0 Port A Access Modes (Continued)
4.2 ACCESS MODE 1
Mode 1, asynchronous access, is selected by asserting the
input B1 during programming (B1e1). This mode allows ac-
cesses to start immediately from the access request input,
ADS. To initiate a Mode 1 access, CS is asserted followed
by ADS asserted. If precharge time was met, a refresh of
the DRAM or a Port B access was not in progress, the RAS
(RASs) would be asserted from ADS being asserted. If a
refresh or Port B access is in progress or precharge time is
required, the controller will wait until these events have tak-
en place and assert RAS (RASs) from the next rising edge
of clock.
When ADS is asserted or sometime after, AREQ must be
asserted. At this time, ADS can be negated and AREQ will
continue the access. Also, ADS can continue to be asserted
after AREQ has been asserted and negated; however, a
new access will not start until ADS is negated and asserted
again. When address pipelining is not implemented, ADS
and AREQ can be tied together.
The access will end when AREQ is negated.
TL/F/858862
FIGURE 8b. Access Mode 1
14
Obsolete
4.0 Port A Access Modes (Continued)
4.3 EXTENDING CAS WITH EITHER ACCESS MODE
In both access modes, once AREQ is negated, RAS and
DTACK if programmed will be negated. If ECAS0 was as-
serted (0) during programming, CAS (CASs) will be negated
with AREQ. If ECAS0 was negated (1) during programming,
CAS (CASs) will continue to be asserted after RAS has
been negated, given that the appropriate ECAS inputs are
asserted. This allows a DRAM to have data present on the
data out bus while gaining RAS precharge time.
TL/F/858861
FIGURE 9a. Access Mode 0 Extending CAS
TL/F/858863
FIGURE 9b. Access Mode 1 Extending CAS
15
Obsolete
4.0 Port A Access Modes (Continued)
4.4 READ-MODIFY-WRITE CYCLES WITH EITHER ACCESS MODE
There are 2 methods by which this chip can be used to do
read-modify-write access cycles. The first method involves
doing a late write access where the WIN input is asserted
some delay after CAS is asserted. The second method in-
volves doing a page mode read access followed by a page
mode write access with RAS held low (see
Figure 9c
).
CASn must be toggled using the ECASn inputs and WIN has
to be changed from negated to asserted (read to write)
while CAS is negated. This method is better than changing
WIN from negated to asserted in a late write access be-
cause here a problem may arise with DATA IN and DATA
OUT being valid at the same time. This may result in a data
line trying to drive two different levels simultaneously. The
page mode method of a read-modify-write access allows
the user to have transceivers in the system because the
data in (read data) is guaranteed to be high impedance dur-
ing the time the data out (write data) is valid.
TL/F/8588G2
*There may be idle states inserted here by the CPU.
FIGURE 9c. Read-Modify-Write Access Cycle
16
Obsolete
4.0 Port A Access Modes (Continued)
4.5 ADDITIONAL ACCESS SUPPORT FEATURES
To support the different modes of accessing, the
DP8420A/21A/22A offer other access features. These ad-
ditional features include: Address Latches and Column In-
crement (for page/burst mode support), Address Pipelining,
and Delay CAS (to allow the user with a multiplexed bus to
ensure valid data is present before CAS is asserted).
4.5.1 Address Latches and Column Increment
The Address Latches can be programmed, through pro-
gramming bit B0. They can be programmed to either latch
the address or remain in a fall-through mode. If the address
latches are used to latch the address, the controller will
function as follows:
In Mode 0, the rising edge of ALE places the latches in fall-
through, once ALE is negated, the address present in the
row, column and bank input is latched.
In Mode 1, the address latches are in fall through mode until
ADS is asserted. ADS asserted latches the address.
Once the address is latched, the column address can be
incremented with the input COLINC. COLINC can be used
for sequential accesses of static column DRAMs. COLINC
can also be used with the ECAS inputs to support sequen-
tial accesses to page mode DRAMs as shown in
Figure 10
.
COLINC should only be asserted when the signal RFIP is
negated during an access since this input functions as ex-
tended refresh when RFIP is asserted. COLINC must be
negated (0) when the address is being latched (ADS falling
edge in Mode 1). If COLINC is asserted with all of the bits of
the column address asserted (ones), the column address
will return to zero.
TL/F/8588C4
FIGURE 10. Column Increment
The address latches function differently with the DP8422A.
The DP8422A will latch the address of the currently granted
port. If Port A is currently granted, the address will be
latched as described in Section 4.5.1. If Port A is not grant-
ed, and requests an access, the address will be latched on
the first or second positive edge of CLK after GRANTB has
been negated depending on the programming bits R0, R1.
For Port B, if GRANTB is asserted, the address will be
latched with AREQB asserted. If GRANTB is negated, the
address will latch on the first or second positive edge of
CLK after GRANTB is asserted depending on the program-
ming bits R0, R1.
17
Obsolete
4.0 Port A Access Modes (Continued)
4.5.2 Address Pipelining
Address pipelining is the overlapping of accesses to differ-
ent banks of DRAM. If the majority of successive accesses
are to a different bank, the accesses can be overlapped.
Because of this overlapping, the cycle time of the DRAM
accesses are greatly reduced. The DP8420A/21A/22A can
be programmed to allow a new row address to be placed on
the DRAM address bus after the column address hold time
has been met. At this time, a new access can be initiated
with ADS or ALE, depending on the access mode, while
AREQ is used to sustain the current access. The DP8422A
supports address pipelining for Port A only. This mode can-
not be used with page, static column or nibble modes of
operations because the DRAM column address is switched
back to the row address after CAS is asserted. This mode is
programmed through address bit R8 (see
Figures 11a
and
11b
). In this mode, the output WE always functions as
RFRQ.
During address pipelining in Mode 0, shown in
Figure 11c
,
ALE cannot be pulsed high to start another access until
AREQ has been asserted for the previous access for at
least one period of CLK. DTACK, if programmed, will be
negated once AREQ is negated. WAIT, if programmed to
insert wait states, will be asserted once ALE and CS are
asserted.
In Mode 1, shown in
Figure 11d
, ADS can be negated once
AREQ is asserted. After meeting the minimum negated
pulse width for ADS, ADS can again be asserted to start a
new access. DTACK, if programmed, will be negated once
AREQ is negated. WAIT, if programmed, will be asserted
once ADS is asserted.
In either mode with either type of wait programmed, the
DP8420A/21A/22A will still delay the access for precharge
if sequential accesses are to the same bank or if a refresh
takes place.
TL/F/8588G0
FIGURE 11a. Non-Address Pipelined Mode
TL/F/8588G1
FIGURE 11b. Address Pipelined Mode
18
Obsolete
4.0 Port A Access Modes (Continued)
TL/F/8588C5
FIGURE 11c. Mode 0 Address Pipelining (WAIT of 0, (/2T Has Been Programmed.
WAIT is Sampled at the ‘‘T3’’ Falling Clock Edge)
TL/F/8588C6
FIGURE 11d. Mode 1 Address Pipelining (DTACK 1(/2T Programmed, DTACK is Sampled at the ‘‘T3’’ Falling Clock Edge)
19
Obsolete
4.0 Port A Access Modes (Continued)
4.5.3 Delay CAS during Write Accesses
Address bit C9 asserted during programming will cause CAS
to be delayed until the first positive edge of CLK after RAS
is asserted when the input WIN is asserted. Delaying CAS
during write accesses ensures that the data to be written to
DRAM will be setup to CAS asserting as shown in
Figures
12a
and
12b.
If the possibility exists that data still may not
be present after the first positive edge of CLK, CAS can be
delayed further with the ECAS inputs. If address bit C9 is
negated during programming, read and write accesses will
be treated the same (with regard to CAS).
TL/F/8588C7
FIGURE 12a. Mode 0 Delay CAS
TL/F/8588C8
FIGURE 12b. Mode 1 Delay CAS
20
Obsolete
5.0 Refresh Options
The DP8420A/21A/22A support three refresh control mode
options:
1. Automatic Internally Controlled Refresh.
2. Externally Controlled/Burst Refresh.
3. Refresh Request/Acknowledge.
With each of the control modes above, three types of re-
fresh can be performed.
1. All RAS Refresh.
2. Staggered Refresh.
3. Error Scrubbing During All RAS Refresh.
There are three inputs, EXTNDRF, RFSH and DISRFSH,
and two outputs, RFIP and RFRQ, associated with refresh.
There are also ten programming bits: R0 1, R9, C0 6 and
ECAS0 used to program the various types of refreshing.
Asserting the input EXTNDRF, extends the refresh cycle for
a single or multiple integral periods of CLK.
The output RFIP is asserted one period of CLK before the
first refresh RAS is asserted. If an access is currently in
progress, RFIP will be asserted up to one period of CLK
before the first refresh RAS, after AREQ or AREQB is nega-
ted for the access (see
Figure 13
).
The DP8420A/21A/22A will increment the refresh address
counter automatically, independent of the refresh mode
used. The refresh address counter will be incremented once
all the refresh RASs have been negated.
In every combination of refresh control mode and refresh
type, the DP8420A/21A/22A is programmed to keep RAS
asserted a number of CLK periods. The time values of RAS
low during refresh are programmed through programming
bits R0 and R1.
5.1 REFRESH CONTROL MODES
5.1.1. Automatic Internal Refresh
The DP8420A/21A/22A have an internal refresh clock. The
period of the refresh clock is generated from the program-
ming bits C0 3. Every period of the refresh clock, an inter-
nal refresh request is generated. As long as a DRAM ac-
cess is not currently in progress and precharge time has
been met, the internal refresh request will generate an auto-
matic internal refresh. If a DRAM access is in progress, the
DP8420A/21A/22A on-chip arbitration logic will wait until
the access is finished before performing the refresh. The
refresh/access arbitration logic can insert a refresh cycle
between two address pipelined accesses. However, the re-
fresh arbitration logic can not interrupt an access cycle to
perform a refresh. To enable automatic internally controlled
refreshes, the input DISRFSH must be negated.
TL/F/8588F8
Explanation of Terms
RFRQ eReFresh ReQuest internal to the DP8420A/21A/22A. RFRQ has the ability to hold off a pending access.
RFSH eExternally requested ReFreSH
RFIP eReFresh in Progress
ACIP ePort A or Port B (DP8422A only) ACcess in Progress. This means that either RAS is low for an access or is in the process of
transitioning low for an access.
FIGURE 13. DP8420A/21A/22A Access/Refresh Arbitration State Program
21
Obsolete
5.0 Refresh Options (Continued)
5.1.2 Externally Controlled/Burst Refresh
To use externally controlled/burst refresh, the user must
disable the automatic internally controlled refreshes by as-
serting the input DISRFSH. The user is responsible for gen-
erating the refresh request by asserting the input RFSH.
Pulsing RFSH low, sets an internal latch, that is used to
produce the internal refresh request. The refresh cycle will
take place on the next positive edge of CLK as shown in
Figure 14a
. If an access to DRAM is in progress or pre-
charge time for the last access has not been met, the re-
fresh will be delayed. Since pulsing RFSH low sets a latch,
the user does not have to keep RFSH low until the refresh
starts. When the last refresh RAS negates, the internal re-
fresh request latch is cleared.
TL/F/858864
FIGURE 14a. Single External Refreshes (2 Periods of RAS Low during Refresh Programmed)
By keeping RFSH asserted past the positive edge of CLK
which ends the refresh cycle as shown in
Figure 14b
, the
user will perform another refresh cycle. Using this tech-
nique, the user can perform a burst refresh consisting of any
number of refresh cycles. Each refresh cycle during a burst
refresh will meet the refresh RAS low time and the RAS
precharge time (programming bits R0 1).
If the user desires to burst refresh the entire DRAM (all row
addresses) he could generate an end of count signal (burst
refresh finished) by looking at one of the
DP8420A/21A/22A high address outputs (Q7, Q8, Q9 or
Q10) and the RFIP output. The Qn outputs function as a
decode of how many row addresses have been refreshed
(Q7 e128 refreshes, Q8 e256 refreshes, Q9 e512 re-
freshes, Q10 e1024 refreshes).
TL/F/858865
FIGURE 14b. External Burst Refresh (2 Periods of RAS Precharge,
2 Periods of Refresh RAS Low during Refresh Programmed)
22
Obsolete
5.0 Refresh Options (Continued)
5.1.3 Refresh Request/Acknowledge
The DP8420A/21A/22A can be programmed to output in-
ternal refresh requests. When the user programs ECAS0
negated (1) and/or address pipelining mode is selected, the
WE output functions as RFRQ. RFRQ (WE) will be asserted
by one of two events:
First, when the external circuitry pulses low the input RFSH
which will request an external refresh.
Second, when the internal refresh clock has expired, which
signals that another refresh is needed.
An example of the first case, where an external refresh is
requested while RFRQ is negated (1), is shown in
Figure
15a
. Notice that RFRQ will be asserted from a positive edge
of clock.
On the second case, when the RFRQ is asserted from the
expiration of the internal refresh clock, the user has two
options:
First, if DISRFSH is negated, an automatic internal refresh
will take place. See
Figure 15b
.
Second, with DISRFSH asserted, RFRQ will stay asserted
until RFSH is pulsed low . This option will cause an external-
ly requested/burst refresh to take place. See
Figure 15c
.
RFRQ will go high and then assert (toggle) if additional peri-
ods of the internal refresh clock have expired and neither an
externally controlled refresh nor an automatically controlled
internal refresh have taken place, see
Figure 15d
. If a time
critical event, or long accesses like page/static column
mode can not be interrupted, RFRQ pulsing high can be
used to increment a counter. This counter can be used to
perform a burst refresh of the number of refreshes missed
(through the RFSH input).
TL/F/858866
FIGURE 15a. Externally Controlled Single and Burst Refresh with Refresh Request
(RFRQ) Output (2 Periods of RAS Low during Refresh Programmed)
TL/F/858867
FIGURE 15b. Automatic Internal Refresh with Refresh Request (3T of RAS Low during Refresh Programmed)
23
Obsolete
5.0 Refresh Options (Continued)
TL/F/858865
FIGURE 15c. External Burst Refresh (2 Periods of RAS Precharge,
2 Periods of Refresh RAS Low during Refresh Programmed)
TL/F/858868
FIGURE 15d. Refresh Request Timing
24
Obsolete
5.0 Refresh Options (Continued)
5.2 REFRESH CYCLE TYPES
Three different types of refresh cycles are available for use.
The three different types are mutually exclusive and can be
used with any of the three modes of refresh control. The
three different refresh cycle types are: all RAS refresh, stag-
gered RAS refresh and error scrubbing during all RAS re-
fresh. In all refresh cycle types, the RAS precharge time is
guaranteed: between the previous access RAS ending and
the refresh RAS0 starting; between refresh RAS3 ending
and access RAS beginning; between burst refresh RASs.
5.2.1 Conventional RAS Refresh
A conventional refresh cycle causes RAS0 3 to all assert
from the first positive edge of CLK after RFIP is asserted as
shown in
Figure 16
. RAS0 3 will stay asserted until the
number of positive edges of CLK programmed have passed.
On the last positive edge, RAS0 3, and RFIP will be negat-
ed. This type of refresh cycle is programmed by negating
address bit R9 during programming.
TL/F/858869
FIGURE 16. Conventional RAS Refresh
5.2.2 Staggered RAS Refresh
A staggered refresh staggers each RAS or group of RASs
by a positive edge of CLK as shown in
Figure 17
. The num-
ber of RASs, which will be asserted on each positive edge
of CLK, is determined by the RAS, CAS configuration mode
programming bits C4 C6. If single RAS outputs are select-
ed during programming, then each RAS will assert on suc-
cessive positive edges of CLK. If two RAS outputs are se-
lected during programming then RAS0 and RAS1 will assert
on the first positive edge of CLK after RFIP is asserted.
RAS2 and RAS3 will assert on the second positive edge of
CLK after RFIP is asserted. If all RAS outputs were selected
during programming, all RAS outputs would assert on the
first positive edge of CLK after RFIP is asserted. Each RAS
or group of RASs will meet the programmed RAS low time
and then negate.
TL/F/858870
FIGURE 17. Staggered RAS Refresh
25
Obsolete
5.0 Refresh Options (Continued)
5.2.3 Error Scrubbing during Refresh
The DP8420A/21A/22A support error scrubbing during all
RAS DRAM refreshes. Error scrubbing during refresh is se-
lected through bits C4 C6 with bit R9 negated during pro-
gramming. Error scrubbing can not be used with staggered
refresh (see Section 8.0). Error scrubbing during refresh al-
lows a CAS or group of CASs to assert during the all RAS
refresh as shown in
Figure 18
. This allows data to be read
from the DRAM array and passed through an Error Detec-
tion And Correction Chip, EDAC. If the EDAC determines
that the data contains a single bit error and corrects that
error, the refresh cycle can be extended with the input ex-
tend refresh, EXTNDRF, and a read-modify-write operation
can be performed by asserting WE. It is the responsibility of
the designer to ensure that WE is negated. The DP8422A
has a 24-bit internal refresh address counter that contains
the 11 row, 11 column and 2 bank addresses. The
DP8420A/21A have a 22-bit internal refresh address coun-
ter that contains the 10 row, 10 column and 2 bank address-
es. These counters are configured as bank, column, row
with the row address as the least significant bits. The bank
counter bits are then used with the programming selection
to determine which CAS or group of CASs will assert during
a refresh.
TL/F/858846
FIGURE 18. Error Scrubbing during Refresh
26
Obsolete
5.0 Refresh Options (Continued)
5.3 EXTENDING REFRESH
The programmed number of periods of CLK that refresh
RASs are asserted can be extended by one or multiple peri-
ods of CLK. Only the all RAS (with or without error scrub-
bing) type of refresh can be extended. To extend a refresh
cycle, the input extend refresh, EXTNDRF, must be assert-
ed before the positive edge of CLK that would have negated
all the RAS outputs during the refresh cycle and after the
positive edge of CLK which starts all RAS outputs during the
refresh as shown in
Figure 19
. This will extend the refresh to
the next positive edge of CLK and EXTNDRF will be sam-
pled again. The refresh cycle will continue until EXTNDRF is
sampled low on a positive edge of CLK.
5.4 CLEARING THE REFRESH ADDRESS COUNTER
The refresh address counter can be cleared by asserting
RFSH while DISRFSH is negated as shown in
Figure 20a
.
This can be used prior to a burst refresh of the entire memo-
ry array. By asserting RFSH one period of CLK before
DISRFSH is asserted and then keeping both inputs assert-
ed, the DP8420A/21A/22A will clear the refresh address
counter and then perform refresh cycles separated by the
programmed value of precharge as shown in
Figure 20b
.An
end-of-count signal can be generated from the Q DRAM
address outputs of the DP8420A/21A/22A and used to ne-
gate RFSH.
TL/F/858871
FIGURE 19. Extending Refresh with the Extend Refresh (EXTNDRF) Input
TL/F/858872
FIGURE 20a. Clearing the Refresh Address Counter
TL/F/858873
FIGURE 20b. Clearing the Refresh Counter during Burst
27
Obsolete
5.0 Refresh Options (Continued)
5.5 CLEARING THE REFRESH REQUEST CLOCK
The refresh request clock can be cleared by negating
DISRFSH and asserting RFSH for 500 ns, one period of the
internal 2 MHz clock as shown in
Figure 21
. By clearing the
refresh request clock, the user is guaranteed that an inter-
nal refresh request will not be generated for approximately
15 ms, one refresh clock period, from the time RFSH is neg-
ated. This action will also clear the refresh address counter.
TL/F/858875
FIGURE 21. Clearing the Refresh Request Clock Counter
6.0 Port A Wait State Support
Wait states allow a CPU’s access cycle to be increased by
one or multiple CPU clock periods. The wait or ready input is
named differently by CPU manufacturers. However, any
CPU’s wait or ready input is compatible with either the WAIT
or DTACK output of the DP8420A/21A/22A. The user de-
termines whether to program WAIT or DTACK (R7) and
which value to select for WAIT or DTACK (R2, R3) depend-
ing upon the CPU used and where the CPU samples its wait
input during an access cycle.
The decision to terminate the CPU access cycle is directly
affected by the speed of the DRAMs used. The system de-
signer must ensure that the data from the DRAMs will be
present for the CPU to sample or that the data has been
written to the DRAM before allowing the CPU access cycle
to terminate.
The insertion of wait states also allows a CPU’s access cy-
cle to be extended until the DRAM access has taken place.
The DP8420A/21A/22A insert wait states into CPU access
cycles due to; guaranteeing precharge time, refresh current-
ly in progress, user programmed wait states, the WAITIN
signal being asserted and GRANTB not being valid
(DP8422A only). If one of these events is taking place and
the CPU starts an access, the DP8420A/21A/22A will insert
wait states into the access cycle, thereby increasing the
length of the CPU’s access. Once the event has been com-
pleted, the DP8420A/21A/22A will allow the access to take
place and stop inserting wait states.
There are six programming bits, R2 R7; an input, WAITIN;
and an output that functions as WAIT or DTACK.
6.1 WAIT TYPE OUTPUT
With the R7 address bit negated during programming, the
user selects the WAIT output. As long as WAIT is sampled
asserted by the CPU, wait states (extra clock periods) are
inserted into the current access cycle as shown in
Figure
22
. Once WAIT is sampled negated, the access cycle is
completed by the CPU. WAIT is asserted at the beginning of
a chip selected access and is programmed to negate a
number of positive edges and/or negative levels of CLK
from the event that starts the access. WAIT can also be
programmed to function in page/burst mode applications.
Once WAIT is negated during an access, and the ECAS
inputs are negated with AREQ asserted, WAIT can be pro-
grammed to toggle, following the ECAS inputs. Once AREQ
is negated, ending the access, WAIT will stay negated until
the next chip selected access. For more details about WAIT
Type Output, see Application Note AN-773.
TL/F/858876
FIGURE 22. WAIT Type Output
28
Obsolete
6.0 Port A Wait State Support (Continued)
6.2 DTACK TYPE OUTPUT
With the R7 address bit asserted during programming, the
user selects the DTACK type output. As long as DTACK is
sampled negated by the CPU, wait states are inserted into
the current access cycle as shown in
Figure 23.
Once
DTACK is sampled asserted, the access cycle is completed
by the CPU. DTACK, which is normally negated, is pro-
grammed to assert a number of positive edges and/or neg-
ative levels from the event that starts RAS for the access.
DTACK can also be programmed to function during page/
burst mode accesses. Once DTACK is asserted and the
ECAS inputs are negated with AREQ asserted, DTACK can
be programmed to negate and assert from the ECAS inputs
toggling to perform a page/burst mode operation. Once
AREQ is negated, ending the access, DTACK will be negat-
ed and stays negated until the next chip selected access.
For more details about DTACK type output see Application
Note AN-773.
6.3 DYNAMICALLY INCREASING THE
NUMBER OF WAIT STATES
The user can increase the number of positive edges of CLK
before DTACK is asserted or WAIT is negated. With the
input WAITIN asserted, the user can delay DTACK asserting
or WAIT negating either one or two more positive edges of
CLK. The number of edges is programmed through address
bit R6. If the user is increasing the number of positive edges
in a delay that contains a negative level, the positive edges
will be met before the negative level. For example if the user
programmed DTACK of (/2T, asserting WAITIN, pro-
grammed as 2T, would increase the number of positive edg-
es resulting in DTACK of 2(/2T as shown in
Figure 24a
. Simi-
larly, WAITIN can increase the number of positive edges in
a page/burst access. WAITIN can be permanently asserted
in systems requiring an increased number of wait states.
WAITIN can also be asserted and negated, depending on
the type of access. As an example, a user could invert the
WRITE line from the CPU and connect the output to
WAITIN. This could be used to perform write accesses with
1 wait state and read accesses with 2 wait states as shown
in
Figure 24b
.
TL/F/858897
FIGURE 23. DTACK Type Output
TL/F/8588C1
FIGURE 24a. WAITIN Example (DTACK is Sampled at the ‘‘T3’’ Falling Clock Edge)
29
Obsolete
6.0 Port A Wait State Support (Continued)
TL/F/8588C2
FIGURE 24b. WAITIN Example (WAIT is Sampled at the End of ‘‘T2’’).
6.4 GUARANTEEING RAS LOW TIME
AND RAS PRECHARGE TIME
The DP8420A/21A/22A will guarantee RAS precharge time
between accesses; between refreshes; and between ac-
cess and refreshes. The programming bits R0 and R1 are
used to program combinations of RAS precharge time and
RAS low time referenced by positive edges of CLK. RAS
low time is programmed for refreshes only. During an ac-
cess, the system designer guarantees the time RAS is as-
serted through the DP8420A/21A/22A wait logic. Since in-
serting wait states into an access increases the length of
the CPU signals which are used to create ADS or ALE and
AREQ, the time that RAS is asserted can be guaranteed.
The precharge time is also guaranteed by the
DP8420A/21A/22A. Each RAS output has a separate posi-
tive edge of CLK counter. AREQ is negated setup to a posi-
tive edge of CLK to terminate the access. That positive
edge is 1T. The next positive edge is 2T. RAS will not be
asserted until the programmed number of positive edges of
CLK have passed as shown in
Figure 25
. Once the pro-
grammed precharge time has been met, RAS will be assert-
ed from the positive edge of CLK. However, since there is a
precharge counter per RAS, an access using another RAS
will not be delayed. Precharge time before a refresh is al-
ways referenced from the access RAS negating before
RAS0 for the refresh asserting. After a refresh, precharge
time is referenced from RAS3 negating, for the refresh, to
the access RAS asserting.
TL/F/8588C3
FIGURE 25. Guaranteeing RAS Precharge (DTACK is Sampled at the ‘‘T2’’ Falling Clock Edge)
30
Obsolete
7.0 RAS and CAS Configuration Modes
The DP8420A/21A/22A allow the user to configure the
DRAM array to contain one, two or four banks of DRAM.
Depending on the functions used, certain considerations
must be used when determining how to set up the DRAM
array. Programming address bits C4, C5 and C6 along with
bank selects, B0 1, and CAS enables, ECAS0 3, deter-
mine which RAS or group of RASs and which CAS or group
of CASs will be asserted during an access. Different memo-
ry schemes are described. The DP8420A/21A/22A is spec-
ified driving a heavy load of 72 DRAMs, representing four
banks of DRAM with 16-bit words and 2 parity bits. The
DP8420A/21A/22A can drive more than 72 DRAMs, but the
AC timing must be increased. Since the RAS and CAS out-
puts are configurable, all RAS and CAS outputs should be
used for the maximum amount of drive.
7.1 BYTE WRITING
By selecting a configuration in which all CAS outputs are
selected during an access, the ECAS inputs enable a single
or group of CAS outputs to select a byte (or bytes) in a word
size of up to 32 bits. In this case, the RAS outputs are used
to select which of up to 4 banks is to be used as shown in
Figures 26a
and
26b
. In systems with a word size of 16 bits,
the byte enables can be gated with a high order address bit
to produce four byte enables which gives an equivalent to 8
banks of 16-bit words as shown in
Figure 26d
. If less memo-
ry is required, each CAS should be used to drive each nibble
in the 16-bit word as shown in
Figure 26c
.
TL/F/8588C9
FIGURE 26a. DRAM Array Setup for 32-Bit System (C6, C5, C4 e1, 1, 0 during Programming)
TL/F/8588D0
FIGURE 26b. DRAM Array Setup for 32-Bit, 1 Bank System (C6, C5, C4 e0, 0, 0 Allowing Error Scrubbing
or C6, C5, C4 e0, 1, 1 No Error Scrubbing during Programming)
31
Obsolete
7.0 RAS and CAS Configuration Modes (Continued)
TL/F/8588D1
FIGURE 26c. DRAM Array Setup for 16-Bit System (C6, C5, C4 e1, 1, 0 during Programming)
TL/F/8588D2
FIGURE 26d. 8 Bank DRAM Array for 16-Bit System (C6, C5, C4 e1, 1, 0 during Programming)
32
Obsolete
7.0 RAS and CAS Configuration Modes (Continued)
7.2 MEMORY INTERLEAVING
Memory interleaving allows the cycle time of DRAMs to be
reduced by having sequential accesses to different memory
banks. Since the DP8420A/21A/22A have separate pre-
charge counters per bank, sequential accesses will not be
delayed if the accessed banks use different RAS outputs.
To ensure different RAS outputs will be used, a mode is
selected where either one or two RAS outputs will be as-
serted during an access. The bank select or selects, B0 and
B1, are then tied to the least significant address bits, caus-
ing a different group of RASs to assert during each sequen-
tial access as shown in
Figure 27
. In this figure there should
be at least one clock period of all RAS’s negated between
different RAS’s being asserted to avoid the condition of a
CAS before RAS refresh cycle.
7.3 ADDRESS PIPELINING
Address pipelining allows several access RASstobeas-
serted at once. Because RASs can overlap, each bank re-
quires either a mode where one RAS and one CAS are used
per bank as shown in
Figure 28a
or where two RASs and
two CASs are used per bank as shown in
Figure 28b
. Byte
writing can be accomplished in a 16-bit word system if two
RASs and two CASs are used per bank. In other systems,
WEs (or external gating on the CAS outputs) must be used
to perform byte writing. If WEs are used separate data in
and data out buffers must be used. If the array is not layed
out this way, a CAS to a bank can be low before RAS, which
will cause a refresh of the DRAM, not an access. To take
full advantage of address pipelining, memory interleaving is
used. To memory interleave, the least significant address
bits should be tied to the bank select inputs to ensure that
all ‘‘back to back’’ sequential accesses are not delayed,
since different memory banks are accessed.
TL/F/8588D3
FIGURE 27. Memory Interleaving (C6, C5, C4 e1, 1, 0 during Programming)
33
Obsolete
7.0 RAS and CAS Configuration Modes (Continued)
TL/F/8588D4
FIGURE 28a. DRAM Array Setup for 4 Banks Using Address Pipelining (C6, C5, C4 e1, 1, 1
or C6, C5, C4 e0, 1, 0 (Also Allowing Error Scrubbing) during Programming)
TL/F/8588D5
FIGURE 28b. DRAM Array Setup for Address Pipelining with 2 Banks (C6, C5, C4 e1, 0, 1
or C6, C5, C4 e0, 0, 1 (Also Allowing Error Scrubbing) during Programming)
7.4 ERROR SCRUBBING
In error scrubbing during refresh, the user selects one, two
or four RAS and CAS outputs per bank. When performing
error detection and correction, memory is always accessed
as words. Since the CAS signals are not used to select
individual bytes, the ECAS inputs can be tied low as shown
in
Figures 29a
and
29b
.
TL/F/8588D6
FIGURE 29a. DRAM Array Setup for 4 Banks Using Error Scrubbing (C6, C5, C4 e0, 1, 0 during Programming)
TL/F/8588D7
FIGURE 29b. DRAM Array Setup for Error Scrubbing with 2 Banks (C6, C5, C4 e0, 0, 1 during Programming)
34
Obsolete
7.0 RAS and CAS Configuration Modes (Continued)
7.5 PAGE/BURST MODE
In a static column, page or burst mode system, the least
significant bits must be tied to the column address in order
to ensure that the page/burst accesses are to sequential
memory addresses, as shown in
Figure 30.
In a nibble
mode system, the least significant bits must be tied to the
highest column and row address bits in order to ensure that
sequential address bits are the ‘‘nibble’’ bits for nibble mode
accesses
(Figure 30)
. The ECAS inputs may then be tog-
gled with the DP8420A/21A/22A’s address latches in fall-
through mode, while AREQ is asserted. The ECAS inputs
can also be used to select individual bytes. When using nib-
ble mode DRAMS, the third and fourth address bits can be
tied to the bank select inputs to perform memory interleav-
ing. In page or static column modes, the two address bits
after the page size can be tied to the bank select inputs to
select a new bank if the page size is exceeded.
TL/F/8588D8
*See table below for row, column & bank address bit map. A0, A1 are used for byte addressing in this example.
Addresses Nibble Mode*Page Mode/Static Column Mode Page Size
256 Bits/Page 512 Bits/Page 1024 Bits/Page 2048 Bits/Page
Column C9,R9 eA2,A3 C07 eA2–9 C0–8 eA2–10 C0–9 eA2–11 C0–10 eA2–12
Address C08 eX C8–10 eX C9,10 eX C10 eX
Row XXX X X
Address
B0 A4 A10 A11 A12 A13
B1 A5 A11 A12 A13 A14
Assume that the least significant address bits are used for byte addressing. Given a 32-bit system A0,A1 would be
used for byte addressing.
XeDON’T CARE, the user can do as he pleases.
*Nibble mode values for R and C assume a system using 1 Mbit DRAMs.
FIGURE 30. Page, Static Column, Nibble Mode System
35
Obsolete
8.0 Test Mode
Staggered refresh in combination with the error scrubbing
mode places the DP8420A/21A/22A in test mode. In this
mode, the 24-bit refresh counter is divided into a 13-bit and
11-bit counter. During refreshes both counters are incre-
mented to reduce test time.
9.0 DRAM Critical Timing
Parameters
The two critical timing parameters, shown in
Figure 31
, that
must be met when controlling the access timing to a DRAM
are the row address hold time, tRAH, and the column ad-
dress setup time, tASC. Since the DP8420A/21A/22A con-
tain a precise internal delay line, the values of these param-
eters can be selected at programming time. These values
will also increase and decrease if DELCLK varies from
2 MHz.
9.1 PROGRAMMABLE VALUES OF tRAH AND tASC
The DP8420A/21A/22A allow the values of tRAH and tASC
to be selected at programming time. For each parameter,
two choices can be selected. tRAH, the row address hold
time, is measured from RAS asserted to the row address
starting to change to the column address. The two choices
for tRAH are 15 ns and 25 ns, programmable through ad-
dress bit C8.
tASC, the column address setup time, is measured from the
column address valid to CAS asserted. The two choices for
tASC are 0 ns and 10 ns, programmable through address bit
C7.
9.2 CALCULATION OF tRAH AND tASC
There are two clock inputs to the DP8420A/21A/22A.
These two clocks, DELCLK and CLK can either be tied to-
gether to the same clock or be tied to different clocks run-
ning asynchronously at different frequencies.
The clock input, DELCLK, controls the internal delay line
and refresh request clock. DELCLK should be a multiple of
2 MHz. If DELCLK is not a multiple of 2 MHz, tRAH and tASC
will change. The new values of tRAH and tASC can be calcu-
lated by the following formulas:
If tRAH was programmed to equal 15 ns then tRAH e
30*(((DELCLK Divisor)*2 MHz/(DELCLK Frequency))b1)
a15 ns.
If tRAH was programmed to equal 25 ns then tRAH e
30*(((DELCLK Divisor)*2 MHz/(DELCLK Frequency))b1)
a25 ns.
If tASC was programmed to equal 0 ns then tASC e15*
((DELCLK Divisor)*2 MHz/(DELCLK Frequency)) b15 ns.
If tASC was programmed to equal 10 ns then tASC e25*
((DELCLK Divisor)*2 MHz/(DELCLK Frequency)) b15 ns.
Since the values of tRAH and tASC are increased or de-
creased, the time to CAS asserted will also increase or de-
crease. These parameters can be adjusted by the following
formula:
Delay to CAS eActual Spec. aActual tRAH b
Programmed tRAH aActual tASC bProgrammed tASC.
TL/F/8588E3
FIGURE 31. tRAH and tASC
36
Obsolete
10.0 Dual Accessing (DP8422A)
The DP8422A has all the functions previously described. In
addition to those features, the DP8422A also has the capa-
bilities to arbitrate among refresh, Port A and a second port,
Port B. This allows two CPUs to access a common DRAM
array. DRAM refresh has the highest priority followed by the
currently granted port. The ungranted port has the lowest
priority. The last granted port will continue to stay granted
even after the access has terminated, until an access re-
quest is received from the ungranted port (see
Figure 32a
).
The dual access configuration assumes that both Port A
and Port B are synchronous to the system clock. If they are
not synchronous to the system clock they should be exter-
nally synchronized (Ex. By running the access requests
through several Flip-Flops, see
Figure 34a
).
10.1 PORT B ACCESS MODE
Port B accesses are initiated from a single input, AREQB.
When AREQB is asserted, an access request is generated.
If GRANTB is asserted and a refresh is not taking place or
precharge time is not required, RAS will be asserted when
AREQB is asserted. Once AREQB is asserted, it must stay
asserted until the access is over. AREQB negated, negates
RAS as shown in
Figure 32b
. Note that if ECAS0 e1 during
programming the CAS outputs may be held asserted (be-
yond RASn negating) by continuing to assert the appropri-
ate ECASn inputs (the same as Port A accesses). If Port B
is not granted, the access will begin on the first or second
positive edge of CLK after GRANTB is asserted (See R0,
R1 programming bit definitions) as shown in
Figure 32c
, as-
suming that Port A is not accessing the DRAM (CS, ADS/
ALE and AREQ) and RAS precharge for the particular bank
has completed. It is important to note that for GRANTB to
transition to Port B, Port A must not be requesting an ac-
cess at a rising clock edge (or locked) and Port B must be
requesting an access at that rising clock edge. Port A can
request an access through CS and ADS/ALE or CS and
AREQ. Therefore during an interleaved access where CS
and ADS/ALE become asserted before AREQ from the pre-
vious access is negated, Port A will retain GRANTB e0
whether AREQB is asserted or not.
Since there is no chip select for Port B, AREQB must incor-
porate this signal. This mode of accessing is similar to Mode
1 accessing for Port A.
TL/F/8588F9
Explanation of Terms
AREQA eChip Selected access request from Port A
AREQB eChip Selected access request from Port B
LOCK eExternally controlled LOCKing of the Port
that is currently GRANTed.
FIGURE 32a. DP8422A Port A/Port B Arbitration
State Diagram. This arbitration may take place
during the ‘‘ACCESS’’ or ‘‘REFRESH’’
state (see
Figure 13a
).
TL/F/8588E4
FIGURE 32b. Access Request for Port B
TL/F/8588E5
FIGURE 32c. Delayed Port B Access
37
Obsolete
10.0 Dual Accessing (DP8422A) (Continued)
10.2 PORT B WAIT STATE SUPPORT
Advanced transfer acknowledge for Port B, ATACKB,is
used for wait state support for Port B. This output will be
asserted when RAS for the Port B access is asserted, as
shown in
Figures 33a
and
33b
. Once asserted, this output
will stay asserted until AREQB is negated. With external
logic, ATACKB can be made to interface to any CPU’s wait
input as shown in
Figure 33c
.
10.3 COMMON PORT A AND PORT B DUAL PORT
FUNCTIONS
An input, LOCK, and an output, GRANTB, add additional
functionality to the dual port arbitration logic. LOCK allows
Port A or Port B to lock out the other port from the DRAM.
When a Port is locked out of the DRAM, wait states will be
inserted into its access cycle until it is allowed to access
memory. GRANTB is used to multiplex the input control sig-
nals and addresses to the DP8422A.
10.3.1 GRANTB Output
The output GRANTB determines which port has current ac-
cess to the DRAM array. GRANTB asserted signifies Port B
has access. GRANTB negated signifies Port A has access
to the DRAM array.
TL/F/8588E6
FIGURE 33a. Non-Delayed Port B Access
TL/F/8588E7
FIGURE 33b. Delayed Port B Access
TL/F/858830
A. Extend ATACK to (/2T((/2 Clock) after RAS goes low.
TL/F/858831
B. Extend ATACK to 1T after RAS goes low.
TL/F/858832
C. Synchronize ATACKB to CPU B Clock. This is useful if CPU B runs asynchronous to the DP8422.
FIGURE 33c. Modifying Wait Logic for Port B
38
Obsolete
10.0 Dual Accessing (DP8422A) (Continued)
Since the DP8422A has only one set of address inputs, the
signal is used, with the addition of buffers, to allow the cur-
rently granted port’s addresses to reach the DP8422A. The
signals which need to be bufferred are R0 10, C0 10,
B0 1, ECAS0–3, WE, and LOCK. All other inputs are not
common and do not have to be buffered as shown in
Figure
34a.
If a Port, which is not currently granted, tries to access
the DRAM array, the GRANTB output will transition from a
rising clock edge from AREQ or AREQB negating and will
precede the RAS for the access by one or two clock peri-
ods. GRANTB will then stay in this state until the other port
requests an access and the currently granted port is not
accessing the DRAM as shown in
Figure 34b
.
TL/F/858855
*If Port B is synchronous the Request Synchronizing logic will not be required.
FIGURE 34a. Dual Accessing with the DP8422A (System Block Diagram)
39
Obsolete
10.0 Dual Accessing (DP8422A) (Continued)
TL/F/858829
FIGURE 34b. Wait States during a Port B Access
10.3.2 LOCK Input
When the LOCK input is asserted, the currently granted port
can ‘‘lock out’’ the other port through the insertion of wait
states to that port’s access cycle. LOCK does not disable
refreshes, it only keeps GRANTB in the same state even if
the other port requests an access, as shown in
Figure 35a
.
LOCK can be used by either port.
TL/F/8588E8
FIGURE 35. LOCK Function
40
Obsolete
11.0 Absolute Maximum Ratings (Note 1)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales
Office/Distributors for availability and specifications.
Temperature under Bias ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ0§Ctoa
70§C
Storage Temperature ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀb65§Ctoa
150§C
All Input or Output Voltage
with Respect to GNDÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀb0.5V to a7V
Power Dissipation @20 MHzÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ0.5W
ESD Rating to be determined.
12.0 DC Electrical Characteristics TAe0§Ctoa
70§C, VCC e5V g10%, GND e0V
Symbol Parameter Conditions Min Typ Max Units
VIH Logical 1 Input Voltage Tested with a Limited 2.0 VCC a0.5 V
Functional Pattern
VIL Logical 0 Input Voltage Tested with a Limited b0.5 0.8 V
Functional Pattern
VOH1 Q and WE Outputs IOH eb
10 mA VCC b1.0 V
VOL1 Q and WE Outputs IOL e10 mA 0.5 V
VOH2 All Outputs except Qs, WE IOH eb
3mA V
CC b1.0 V
VOL2 All Outputs except Qs, WE IOL e3 mA 0.5 V
IIN Input Leakage Current VIN eVCC or GND b10 10 mA
IIL ML ML Input Current (Low) VIN eGND 200 mA
ICC1 Standby Current CLK at 8 MHz (VIN eVCC or GND) 6 15 mA
ICC1 Standby Current CLK at 20 MHz (VIN eVCC or GND) 8 17 mA
ICC1 Standby Current CLK at 25 MHz (VIN eVCC or GND) 10 20 mA
ICC2 Supply Current CLK at 8 MHz (Inputs Active) 20 40 mA
(ILOAD e0) (VIN eVCC or GND)
ICC2 Supply Current CLK at 20 MHz (Inputs Active) 40 75 mA
(ILOAD e0) (VIN eVCC or GND)
ICC2 Supply Current CLK at 25 MHz (Inputs Active) 50 95 mA
(ILOAD e0) (VIN eVCC or GND)
CIN*Input Capacitance fIN at 1 MHz 10 pF
*CIN is not 100% tested.
41
Obsolete
13.0 AC Timing Parameters
Two speed selections are given, the DP8420A/21A/22A-20
and the DP8420A/21A/22A-25. The differences between
the two parts are the maximum operating frequencies of the
input CLKs and the maximum delay specifications. Low fre-
quency applications may use the ‘‘b25’’ part to gain im-
proved timing.
The AC timing parameters are grouped into sectional num-
bers as shown below. These numbers also refer to the tim-
ing diagrams.
1 36 Common parameters to all modes of operation
50 56 Difference parameters used to calculate;
RAS low time,
RAS precharge time,
CAS high time and
CAS low time
100 121 Common dual access parameters used for Port
B accesses and inputs and outputs used only in
dual accessing
200 212 Refresh parameters
300 315 Mode 0 access parameters used in both single
and dual access applications
400 416 Mode 1 access parameters used in both single
and dual access applications
450 455 Special Mode 1 access parameters which super-
sede the 400 416 parameters when dual ac-
cessing
500 506 Programming parameters
Unless otherwise stated VCC e5.0V g10%, 0 kTAk
70§C, the output load capacitance is typical for 4 banks of
18 DRAMs per bank, including trace capacitance (see Note
2).
Two different loads are specified:
CLe50 pF loads on all outputs except
CLe150 pF loads on Q0 8, 9, 10 and WE;or
C
He50 pF loads on all outputs except
CHe125 pF loads on RAS0 3 and CAS0–3 and
CHe380 pF loads on Q0 8, 9, 10 and WE.
Note 1: ‘‘Absolute Maximum Ratings’’ are the values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the device
should be operated at these limits. The table of ‘‘Electrical Characteristics’’ provides conditions for actual device operation.
Note 2: Input pulse 0V to 3V; tR etF e2.5 ns. Input reference point on AC measurements is 1.5V. Output reference points are 2.4V for High and 0.8V for Low.
Note 3: AC Production testing is done at 50 pF.
TL/F/8588E9
FIGURE 36. Clock, DELCLK Timing
42
Obsolete
13.0 AC Timing Parameters (Continued)
Unless otherwise stated VCC e5.0V g10%, 0§CkTAk70§C, the output load capacitance is typical for 4 banks of 18 DRAMs
per bank, including trace capacitance (Note 2).
Two different loads are specified:
CLe50 pF loads on all outputs except
CLe150 pF loads on Q0 8, 9, 10 and WE;or
C
He50 pF loads on all outputs except
CHe125 pF loads on RAS0 3 and CAS0–3 and
CHe380 pF loads on Q0 8, 9, 10 and WE.
Common Parameter
8420A/21A/22A-20 8420A/21A/22A-25
Number Symbol Description CLCHCLCH
Min Max Min Max Min Max Min Max
1f
CLK CLK Frequency 0 20 0 20 0 25 0 25
2 tCLKP CLK Period 50 50 40 40
3, 4 tCLKPW CLK Pulse Width 15 15 12 12
5 fDCLK DELCLK Frequency 5 20 5 20 5 20 5 20
6 tDCLKP DELCLK Period 50 200 50 200 50 200 50 200
7, 8 tDCLKPW DELCLK Pulse Width 15 15 12 12
9a tPRASCAS0 RAS Asserted to CAS Asserted 30 30 30 30
(tRAH e15 ns, tASC e0 ns)
9b tPRASCAS1 RAS Asserted to CAS Asserted 40 40 40 40
(tRAH e15 ns, tASC e10 ns)
9c tPRASCAS2 (RAS Asserted to CAS Asserted 40 40 40 40
(tRAH e25 ns, tASC e0 ns)
9d tPRASCAS3 (RAS Asserted to CAS Asserted 50 50 50 50
(tRAH e25 ns, tASC e10 ns)
10a tRAH Row Address Hold Time (tRAH e15) 15 15 15 15
10b tRAH Row Address Hold Time (tRAH e25) 25 25 25 25
11a tASC Column Address Setup Time (tASC e0) 0 0 0 0
11b tASC Column Address Setup Time (tASC e10) 10 10 10 10
12 tPCKRAS CLK High to RAS Asserted 27 32 22 26
following Precharge
13 tPARQRAS AREQ Negated to RAS Negated 38 43 31 35
14 tPENCL ECAS03 Asserted to CAS Asserted 23 31 20 27
15 tPENCH ECAS0 3 Negated to CAS Negated 25 33 20 27
16 tPARQCAS AREQ Negated to CAS Negated 60 68 47 54
17 tPCLKWH CLK to WAIT Negated 39 39 31 31
18 tPCLKDL0 CLK to DTACK Asserted
(Programmed as DTACK of 1/2, 1, 1(/2 33 33 28 28
or if WAITIN is Asserted)
19 tPEWL ECAS Negated to WAIT Asserted 44 44 36 36
during a Burst Access
20 tSECK ECAS Asserted Setup to CLK High to
Recognize the Rising Edge of CLK 24 24 19 19
during a Burst Access
43
Obsolete
13.0 AC Timing Parameters (Continued)
Unless otherwise stated VCC e5.0V g10%, 0§CkTAk70§C, the output load capacitance is typical for 4 banks of 18 DRAMs
per bank, including trace capacitance (Note 2).
Two different loads are specified:
CLe50 pF loads on all outputs except
CLe150 pF loads on Q0 8, 9, 10 and WE;or
C
He50 pF loads on all outputs except
CHe125 pF loads on RAS0 3 and CAS0–3 and
CHe380 pF loads on Q0 8, 9, 10 and WE.
Common Parameter
8420A/21A/22A-20 8420A/21A/22A-25
Number Symbol Description CLCHCLCH
Min Max Min Max Min Max Min Max
21 tPEDL ECAS Asserted to DTACK
Asserted during a Burst Access 48 48 38 38
(Programmed as DTACK0)
22 tPEDH ECAS Negated to DTACK 49 49 38 38
Negated during a Burst Access
23 tSWCK WAITIN Asserted Setup to CLK 5 5 5 5
24 tPWINWEH WIN Asserted to WE Asserted 34 44 27 37
25 tPWINWEL WIN Negated to WE Negated 34 44 27 37
26 tPAQ Row, Column Address Valid to 29 38 26 35
Q0 8, 9, 10 Valid
27 tPCINCQ COLINC Asserted to Q08, 9, 10 34 43 30 39
Incremented
28 tSCINEN COLINC Asserted Setup to ECAS 18 19 17 19
Asserted to Ensure tASC e0ns
29a tSARQCK1 AREQ, AREQB Negated Setup to CLK 46 46 37 37
High with 1 Period of Precharge
29b tSARQCK2 AREQ, AREQB Negated Setup to CLK High 19 19 15 15
with l1 Period of Precharge Programmed
30 tPAREQDH AREQ Negated to DTACK Negated 34 34 27 27
31 tPCKCAS CLK High to CAS Asserted 31 39 25 32
when Delayed by WIN
32 tSCADEN Column Address Setup to ECAS 14 15 14 16
Asserted to Guarantee tASC e0
33 tWCINC COLINC Pulse Width 20 20 20 20
34a tPCKCL0 CLK High to CAS Asserted following 81 89 72 79
Precharge (tRAH e15 ns, tASC e0 ns)
34b tPCKCL1 CLK High to CAS Asserted following 91 99 82 89
Precharge (tRAH e15 ns, tASC e10 ns)
34c tPCKCL2 CLK High to CAS Asserted following 91 99 82 89
Precharge (tRAH e25 ns, tASC e0 ns)
34d tPCKCL3 CLK High to CAS Asserted following 101 109 92 99
Precharge (tRAH e25 ns, tASC e10 ns)
35 tCAH Column Address Hold Time 32 32 32 32
(Interleave Mode Only)
36 tPCQR CAS Asserted to Row Address 90 90 90 90
Valid (Interleave Mode Only)
44
Obsolete
13.0 AC Timing Parameters (Continued)
Unless otherwise stated VCC e5.0V g10%, 0§CkTAk70§C, the output load capacitance is typical for 4 banks of 18 DRAMs
per bank, including trace capacitance (Note 2).
Two different loads are specified:
CLe50 pF loads on all outputs except
CLe150 pF loads on Q0 8, 9, 10 and WE;or
C
He50 pF loads on all outputs except
CHe125 pF loads on RAS0 3 and CAS0–3 and
CHe380 pF loads on Q0 8, 9, 10 and WE.
Difference
8420A/21A/22A-20 8420A/21A/22A-25
Number Symbol Parameter Description CLCHCLCH
Min Max Min Max Min Max Min Max
50 tD1 (AREQ or AREQB Negated to RAS
Negated) Minus (CLK High to RAS 16 16 14 14
Asserted)
51 tD2 (CLK High to Refresh RAS Negated) 13 13 11 11
Minus (CLK High to RAS Asserted)
52 tD3a (ADS Asserted to RAS Asserted
(Mode 1)) Minus (AREQ Negated 4 4 4 4
to RAS Negated)
53 tD3b (CLK High to RAS Asserted (Mode 0)) 4444
Minus (AREQ Negated to RAS Negated)
54 tD4 (ECAS Asserted to CAS Asserted) b77b
77b
77b
77
Minus (ECAS Negated to CAS Negated)
55 tD5 (CLK to Refresh RAS Asserted) Minus 6666
(CLK to Refresh RAS Negated)
56 tD6 (AREQ Negated to RAS Negated)
Minus (ADS Asserted to RAS 12 12 10 10
Asserted (Mode 1))
45
Obsolete
13.0 AC Timing Parameters (Continued)
Unless otherwise stated VCC e5.0V g10%, 0§CkTAk70§C, the output load capacitance is typical for 4 banks of 18 DRAMs
per bank, including trace capacitance (Note 2).
Two different loads are specified:
CLe50 pF loads on all outputs except
CLe150 pF loads on Q0 8, 9, 10 and WE;or
C
He50 pF loads on all outputs except
CHe125 pF loads on RAS0 3 and CAS0–3 and
CHe380 pF loads on Q0 8, 9, 10 and WE.
Common Dual Access
8420A/21A/22A-20 8420A/21A/22A-25
Number Symbol Parameter Description CLCHCLCH
Min Max Min Max Min Max Min Max
100 tHCKARQB AREQB Negated Held from CLK High 3 3 3 3
101 tSARQBCK AREQB Asserted Setup to CLK High 8 8 7 7
102 tPAQBRASL AREQB Asserted to RAS Asserted 43 48 37 41
103 tPAQBRASH AREQB Negated to RAS Negated 41 46 32 36
105 tPCKRASG CLK High to RAS Asserted for 55 60 44 48
Pending Port B Access
106 tPAQBATKBL AREQB Asserted to ATACKB Asserted 57 57 45 45
107 tPCKATKB CLK High to ATACKB Asserted 67 67 51 51
for Pending Access
108 tPCKGH CLK High to GRANTB Asserted 40 40 32 32
109 tPCKGL CLK High to GRANTB Negated 35 35 29 29
110 tSADDCKG Row Address Setup to CLK High That
Asserts RAS following a GRANTB 11 15 11 16
Change to Ensure tASR e0 ns for Port B
111 tSLOCKCK LOCK Asserted Setup to CLK Low 5555
to Lock Current Port
112 tPAQATKBH AREQ Negated to ATACKB Negated 26 26 21 21
113 tPAQBCASH AREQB Negated to CAS Negated 59 67 47 54
114 tSADAQB Address Valid Setup to 711712
AREQB Asserted
116 tHCKARQG AREQ Negated Held from CLK High 5 5 5 5
117 tWAQB AREQB High Pulse Width 31 35 26 31
to Guarantee tASR e0ns
118a tPAQBCAS0 AREQB Asserted to CAS Asserted 103 111 87 94
(tRAH e15 ns, tASC e0 ns)
118b tPAQBCAS1 AREQB Asserted to CAS Asserted 113 121 97 104
(tRAH e15 ns, tASC e10 ns)
118c tPAQBCAS2 AREQB Asserted to CAS Asserted 113 121 97 104
(tRAH e25 ns, tASC e0 ns)
118d tPAQBCAS3 AREQB Asserted to CAS Asserted 123 131 107 114
(tRAH e25 ns, tASC e10 ns)
120a tPCKCASG0 CLK High to CAS Asserted
for Pending Port B Access 113 121 96 103
(tRAH e15 ns, tASC e0 ns)
120b tPCKCASG1 CLK High to CAS Asserted
for Pending Port B Access 123 131 106 113
(tRAH e15 ns, tASC e10 ns)
120c tPCKCASG2 CLK High to CAS Asserted
for Pending Port B Access 123 131 106 113
(tRAH e25 ns, tASC e0 ns)
120d tPCKCASG3 CLK High to CAS Asserted
for Pending Port B Access 133 141 116 123
(tRAH e25 ns, tASC e10 ns)
121 tSBADDCKG Bank Address Valid Setup to CLK
High That Starts RAS 10 10 10 10
for Pending Port B Access
46
Obsolete
13.0 AC Timing Parameters (Continued)
TL/F/8588F0
FIGURE 37. 100: Dual Access Port B
TL/F/8588F1
FIGURE 38. 100: Port A and Port B Dual Access
47
Obsolete
13.0 AC Timing Parameters (Continued)
Unless otherwise stated VCC e5.0V g10%, 0§CkTAk70§C, the output load capacitance is typical for 4 banks of 18 DRAMs
per bank, including trace capacitance (Note 2).
Two different loads are specified:
CLe50 pF loads on all outputs except
CLe150 pF loads on Q0 8, 9, 10 and WE;or
C
He50 pF loads on all outputs except
CHe125 pF loads on RAS0 3 and CAS0–3 and
CHe380 pF loads on Q0 8, 9, 10 and WE.
Refresh Parameter
8420A/21A/22A-20 8420A/21A/22A-25
Number Symbol Description CLCHCLCH
Min Max Min Max Min Max Min Max
200 tSRFCK RFSH Asserted Setup to CLK High 27 27 22 22
201 tSDRFCK DISRFSH Asserted Setup to CLK High 28 28 22 22
202 tSXRFCK EXTENDRF Setup to CLK High 15 15 12 12
204 tPCKRFL CLK High to RFIP Asserted 39 39 31 31
205 tPARQRF AREQ Negated to RFIP Asserted 62 62 50 50
206 tPCKRFH CLK High to RFIP Negated 65 65 51 51
207 tPCKRFRASH CLK High to Refresh RAS Negated 35 40 29 33
208 tPCKRFRASL CLK High to Refresh RAS Asserted 28 33 23 27
209a tPCKCL0 CLK High to CAS Asserted
during Error Scrubbing 82 90 73 80
(tRAH e15 ns, tASC e0 ns)
209b tPCKCL1 CLK High to CAS Asserted
during Error Scrubbing 92 100 83 90
(tRAH e15 ns, tASC e10 ns)
209c tPCKCL2 CLK High to CAS Asserted
during Error Scrubbing 92 100 83 90
(tRAH e25 ns, tASC e0 ns)
209d tPCKCL3 CLK High to CAS Asserted
during Error Scrubbing 102 110 93 100
(tRAH e25 ns, tASC e10 ns)
210 tWRFSH RFSH Pulse Width 15 15 15 15
211 tPCKRQL CLK High to RFRQ Asserted 46 46 40 40
212 tPCKRQH CLK High to RFRQ Negated 50 50 40 40
TL/F/8588F2
FIGURE 39. 200: Refresh Timing
48
Obsolete
13.0 AC Timing Parameters (Continued)
Unless otherwise stated VCC e5.0V g10%, 0§CkTAk70§C, the output load capacitance is typical for 4 banks of 18 DRAMs
per bank, including trace capacitance (Note 2).
Two different loads are specified:
CLe50 pF loads on all outputs except
CLe150 pF loads on Q0 8, 9, 10 and WE;or
C
He50 pF loads on all outputs except
CHe125 pF loads on RAS0 3 and CAS0–3 and
CHe380 pF loads on Q0 8, 9, 10 and WE.
Mode 0 Access
8420A/21A/22A-20 8420A/21A/22A-25
Number Symbol Parameter Description CLCHCLCH
Min Max Min Max Min Max Min Max
300 tSCSCK CS Asserted to CLK High 14 14 13 13
301a tSALECKNL ALE Asserted Setup to CLK High
Not Using On-Chip Latches or 16 16 15 15
if Using On-Chip Latches and
B0, B1, Are Constant, Only 1 Bank
301b tSALECKL ALE Asserted Setup to CLK High,
if Using On-Chip Latches if B0, B1 29 29 29 29
Can Change, More Than One Bank
302 tWALE ALE Pulse Width 18 18 13 13
303 tSBADDCK Bank Address Valid Setup to CLK High 20 20 18 18
304 tSADDCK Row, Column Valid Setup to
CLK High to Guarantee 11 15 11 16
tASR e0ns
305 tHASRCB Row, Column, Bank Address
Held from ALE Negated 10 10 8 8
(Using On-Chip Latches)
306 tSRCBAS Row, Column, Bank Address
Setup to ALE Negated 3 3 2 2
(Using On-Chip Latches)
307 tPCKRL CLK High to RAS Asserted 27 32 22 26
308a tPCKCL0 CLK High to CAS Asserted 81 89 72 79
(tRAH e15 ns, tASC e0 ns)
308b tPCKCL1 CLK High to CAS Asserted 91 99 82 89
(tRAH e15 ns, tASC e10 ns)
308c tPCKCL2 CLK High to CAS Asserted 91 99 82 89
(tRAH e25 ns, tASC e0 ns)
308d tPCKCL3 CLK High to CAS Asserted 101 109 92 99
(tRAH e25 ns, tASC e10 ns)
309 tHCKALE ALE Negated Hold from CLK High 0 0 0 0
310 tSWINCK WIN Asserted Setup to CLK High b21 b21 b16 b16
to Guarantee CAS is Delayed
311 tPCSWL CS Asserted to WAIT Asserted 26 26 22 22
312 tPCSWH CS Negated to WAIT Negated 30 30 25 25
313 tPCLKDL1 CLK High to DTACK Asserted 40 40 32 32
(Programmed as DTACK0)
314 tPALEWL ALE Asserted to WAIT Asserted 35 35 29 29
(CS is Already Asserted)
315 AREQ Negated to CLK High That Starts
Access RAS to Guarantee tASR e0ns41453439
(Non-Interleaved Mode Only)
316 tPCKCV0 CLK High to Column
Address Valid 78 87 66 75
(tRAH e15 ns, tASC e0 ns)
49
Obsolete
13.0 AC Timing Parameters (Continued)
TL/F/8588F3
FIGURE 40. 300: Mode 0 Timing
50
Obsolete
13.0 AC Timing Parameters (Continued)
TL/F/8588F4
(Programmed as C4 e1, C5 e1, C6 e1)
FIGURE 41. 300: Mode 0 Interleaving
51
Obsolete
13.0 AC Timing Parameters (Continued)
Unless otherwise stated VCC e5.0V g10%, 0§CkTAk70§C, the output load capacitance is typical for 4 banks of 18 DRAMs
per bank, including trace capacitance (Note 2).
Two different loads are specified:
CLe50 pF loads on all outputs except
CLe150 pF loads on Q0 8, 9, 10 and WE;or
C
He50 pF loads on all outputs except
CHe125 pF loads on RAS0 3 and CAS0–3 and
CHe380 pF loads on Q0 8, 9, 10 and WE.
Mode 1 Access
8420A/21A/22A-20 8420A/21A/22A-25
Number Symbol Parameter Description CLCHCLCH
Min Max Min Max Min Max Min Max
400a tSADSCK1 ADS Asserted Setup to CLK High 15 15 13 13
400b tSADSCKW ADS Asserted Setup to CLK
(to Guarantee Correct WAIT 31 31 25 25
or DTACK Output; Doesn’t Apply for DTACK0)
401 tSCSADS CS Setup to ADS Asserted 6 6 5 5
402 tPADSRL ADS Asserted to RAS Asserted 30 35 25 29
403a tPADSCL0 ADS Asserted to CAS Asserted 86 94 75 82
(tRAH e15 ns, tASC e0 ns)
403b tPADSCL1 ADS Asserted to CAS Asserted 96 104 85 92
(tRAH e15 ns, tASC e10 ns)
403c tPADSCL2 ADS Asserted to CAS Asserted 96 104 85 92
(tRAH e25 ns, tASC e0 ns)
403d tPADSCL3 ADS Asserted to CAS Asserted 106 114 95 102
(tRAH e25 ns, tASC e10 ns)
404 tSADDADS Row Address Valid Setup to ADS 913914
Asserted to Guarantee tASR e0ns
405 tHCKADS ADS Negated Held from CLK High 0 0 0 0
406 tSWADS WAITIN Asserted Setup to ADS
Asserted to Guarantee DTACK0 0000
Is Delayed
407 tSBADAS Bank Address Setup to ADS Asserted 11 11 11 11
408 tHASRCB Row, Column, Bank Address Held from 10 10 10 10
ADS Asserted (Using On-Chip Latches)
409 tSRCBAS Row, Column, Bank Address Setup to 3322
ADS Asserted (Using On-Chip Latches)
410 tWADSH ADS Negated Pulse Width 12 16 12 17
411 tPADSD ADS Asserted to DTACK Asserted 43 43 35 35
(Programmed as DTACK0)
412 tSWINADS WIN Asserted Setup to ADS Asserted
(to Guarantee CAS Delayed during b10 b10 b10 b10
Writes Accesses)
413 tPADSWL0 ADS Asserted to WAIT Asserted 35 35 29 29
(Programmed as WAIT0, Delayed Access)
414 tPADSWL1 ADS Asserted to WAIT Asserted 35 35 29 29
(Programmed WAIT 1/2 or 1)
415 tPCLKDL1 CLK High to DTACK Asserted
(Programmed as DTACK0, 40 40 32 32
Delayed Access)
416 AREQ Negated to ADS Asserted
to Guarantee tASR e0ns 38423136
(Non Interleaved Mode Only)
417 tPADSCV0 ADS Asserted to Column
Address Valid 83 92 69 78
(tRAH e15 ns, tASC e0 ns)
52
Obsolete
13.0 AC Timing Parameters (Continued)
TL/F/8588F5
FIGURE 42. 400: Mode 1 Timing
53
Obsolete
13.0 AC Timing Parameters (Continued)
TL/F/8588F6
FIGURE 43. 400: COLINC Page/Static Column Access Timing
54
Obsolete
13.0 AC Timing Parameters (Continued)
Unless otherwise stated VCC e5.0V g10%, 0§CkTAk70§C, the output load capacitance is typical for 4 banks of 18 DRAMs
per bank, including trace capacitance (Note 2).
Two different loads are specified:
CLe50 pF loads on all outputs except
CLe150 pF loads on Q0 8, 9, 10 and WE;or
C
He50 pF loads on all outputs except
CHe125 pF loads on RAS0 3 and CAS0–3 and
CHe380 pF loads on Q0 8, 9, 10 and WE.
Mode 1 Dual Access
8420A/21A/22A-20 8420A/21A/22A-25
Number Symbol Parameter Description CLCHCLCH
Min Max Min Max Min Max Min Max
450 tSADDCKG Row Address Setup to CLK High That
Asserts RAS following a GRANTB 11 15 11 16
Port Change to Ensure tASR e0ns
451 tPCKRASG CLK High to RAS Asserted 48 53 38 42
for Pending Access
452 tPCLKDL2 CLK to DTACK Asserted for Delayed 53 53 43 43
Accesses (Programmed as DTACK0)
453a tPCKCASG0 CLK High to CAS Asserted
for Pending Access 101 109 86 93
(tRAH e15 ns, tASC e0 ns)
453b tPCKCASG1 CLK High to CAS Asserted
for Pending Access 111 119 96 103
(tRAH e15 ns, tASC e10 ns)
453c tPCKCASG2 CLK High to CAS Asserted
for Pending Access 111 119 96 103
(tRAH e25 ns, tASC e0 ns)
453d tPCKCASG3 CLK High to CAS Asserted
for Pending Access 121 129 106 113
(tRAH e25 ns, tASC e10 ns)
454 tSBADDCKG Bank Address Valid Setup to CLK High 5544
that Asserts RAS for Pending Access
455 tSADSCK0 ADS Asserted Setup to CLK High 12 12 11 11
55
Obsolete
13.0 AC Timing Parameters (Continued)
Unless otherwise stated VCC e5.0V g10%, 0§CkTAk70§C, the output load capacitance is typical for 4 banks of 18
DRAMs per bank, including trace capacitance (Note 2).
Two different loads are specified:
CLe50 pF loads on all outputs except
CLe150 pF loads on Q0 8, 9, 10 and WE;or
C
He50 pF loads on all outputs except
CHe125 pF loads on RAS0 3 and CAS0–3 and
CHe380 pF loads on Q0 8, 9, 10 and WE.
Programming
8420A/21A/22A-20 8420A/21A/22A-25
Number Symbol Parameter Description CLCHCLCH
Min Max Min Max Min Max Min Max
500 tHMLADD Mode Address Held from ML Negated 8 8 7 7
501 tSADDML Mode Address Setup to ML Negated 6 6 6 6
502 tWML ML Pulse Width 15 15 15 15
503 tSADAQML Mode Address Setup to AREQ Asserted 0 0 0 0
504 tHADAQML Mode Address Held from AREQ Asserted 51 51 38 38
505 tSCSARQ CS Asserted Setup to 6666
AREQ Asserted
506 tSMLARQ ML Asserted Setup to AREQ Asserted 10 10 10 10
TL/F/8588F7
FIGURE 44. 500: Programming
56
Obsolete
14.0 Functional Differences
between the DP8420A/21A/22A
and the DP8420/21/22
1. Extending the Column Address Strobe (CAS) after
AREQ Transitions High
The DP8420A/21A/22A allows CAS to be asserted for
an indefinite period of time beyond AREQ (or AREQB,
DP8422A only. Scrubbing refreshes are not affected.) be-
ing negated by continuing to assert the appropriate ECAS
inputs. This feature is allowed as long as the ECAS0 input
was negated during programming. The DP8420/21/22
does not allow this feature.
2. Dual Accessing
The DP8420A/21A/22A asserts RAS either one or two
clock periods after GRANTB has been asserted or negat-
ed depending upon how the R0 bit was programmed dur-
ing the mode load operation. The DP8420/21/22 will al-
ways start RAS one clock period after GRANTB is assert-
ed or negated. The above statements assume that RAS
precharge has been completed by the time GRANTB is
asserted or negated.
3. Refresh Request Output (RFRQ)
The DP8420A/21A/22A allows RFRQ (refresh request)
to be output on the WE output pin given that ECAS0 was
negated during programming or the controller was pro-
grammed to function in the address pipelining (memory
interleaving) mode. The DP8420/21/22 only allows
RFRQ to be output during the address pipelining mode.
4. Clearing the Refresh Request Clock Counter
The DP8420A/21A/22A allows the internal refresh re-
quest clock counter to be cleared by negating DISRFSH
and asserting RFSH for at least 500 ns. The
DP8420/21/22 clears the internal refresh request clock
counter if DISRFSH remains low for at least 500 ns. Once
the internal refresh request clock counter is cleared the
user is guaranteed that an internally generated RFRQ will
not be generated for at least 13 ms–15 ms (depending
upon how programming bits C0, 1, 2, 3 were pro-
grammed).
15.0 DP8420A/21A/22A User Hints
1. All inputs to the DP8420A/21A/22A should be tied high,
low or the output of some other device.
Note: One signal is active high. COLINC (EXTNDRF) should be tied low
to disable.
2. Each ground on the DP8420A/21A/22A must be decou-
pled to the closest on-chip supply (VCC) with 0.1 mF ce-
ramic capacitor. This is necessary because these
grounds are kept separate inside the
DP8420A/21A/22A. The decoupling capacitors should
be placed as close as possible with short leads to the
ground and supply pins of the DP8420A/21A/22A.
3. The output called ‘‘CAP’’ should have a 0.1 mF capacitor
to ground.
4. The DP8420A/21A/22A has 20Xseries damping resis-
tors built into the output drivers of RAS, CAS, address
and WE/RFRQ. Space should be provided for external
damping resistors on the printed circuit board (or wire-
wrap board) because they may be needed. The value of
these damping resistors (if needed) will vary depending
upon the output, the capacitance of the load, and the
characteristics of the trace as well as the routing of the
trace. The value of the damping resistor also may vary
between the wire-wrap board and the printed circuit
board. To determine the value of the series damping re-
sistor it is recommended to use an oscilloscope and look
at the furthest DRAM from the DP8420A/21A/22A. The
undershoot of RAS, CAS,WEand the addresses should
be kept to less than 0.5V below ground by varying the
value of the damping resistor. The damping resistors
should be placed as close as possible with short leads to
the driver outputs of the DP8420A/21A/22A.
5. The circuit board must have a good VCC and ground
plane connection. If the board is wire-wrapped, the VCC
and ground pins of the DP8420A/21A/22A, the DRAM
associated logic and buffer circuitry must be soldered to
the VCC and ground planes.
6. The traces from the DP8420A/21A/22A to the DRAM
should be as short as possible.
7. ECAS0 should be held low during programming if the user
wishes that the DP8420A/21A/22A be compatible with a
DP8420/21/22 design.
8. Parameter Changes due to Loading
All A.C. parameters are specified with the equivalent load
capacitances, including traces, of 64 DRAMs organized
as 4 banks of 18 DRAMs each. Maximums are based on
worst-case conditions. If an output load changes then the
A.C. timing parameters associated with that particular
output must be changed. For example, if we changed our
output load to
Ce250 pF loads on RAS0 3 and CAS0–3
Ce760 pF loads on Q0 9 and WE
we would have to modify some parameters (not all calcu-
lated here)
$308a clock to CAS asserted
(tRAH e15 ns, tASC e0 ns)
A ratio can be used to figure out the timing change per
change in capacitance for a particular parameter by using
the specifications and capacitances from heavy and light
load timing.
Ratio e$308a w/Heavy Load b$308a w/Light Load
CH(CAS) bCL(CAS)
e79 ns b72 ns
125 pF b50 pF e7ns
75 pF
$308a (actual) e(capacitance difference c
ratio) a$308a (specified)
e(250 pF b125 pF) 7ns
75 pF a79 ns
e11.7 ns a79 ns
e90.7 ns @250 pF load
9. It is required that the user perform a hardware reset of
the DP8420A/21A/22A before programming and using
the chip. A hardware reset consists of asserting both ML
and DISRFSH for a minimum of 16 positive edges of CLK,
see Section 3.1.
57
Obsolete
DP8420A/21A/22A microCMOS Programmable 256k/1M/4M Dynamic RAM Controller/Drivers
Physical Dimensions inches (millimeters) Lit. Ý103064
Plastic Chip Carrier (V)
Order Number DP8420AV-20, DP8420AV-25, DP8421AV-20 or DP8421AV-25
NS Package Number V68A
Plastic Chip Carrier (V)
Order Number DP8422AV-20 or DP8422AV-25
NS Package Number V84A
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL
SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or 2. A critical component is any component of a life
systems which, (a) are intended for surgical implant support device or system whose failure to perform can
into the body, or (b) support or sustain life, and whose be reasonably expected to cause the failure of the life
failure to perform, when properly used in accordance support device or system, or to affect its safety or
with instructions for use provided in the labeling, can effectiveness.
be reasonably expected to result in a significant injury
to the user.
National Semiconductor National Semiconductor National Semiconductor National Semiconductor
Corporation Europe Hong Kong Ltd. Japan Ltd.
1111 West Bardin Road Fax: (
a
49) 0-180-530 85 86 13th Floor, Straight Block, Tel: 81-043-299-2309
Arlington, TX 76017 Email: cnjwge
@
tevm2.nsc.com Ocean Centre, 5 Canton Rd. Fax: 81-043-299-2408
Tel: 1(800) 272-9959 Deutsch Tel: (
a
49) 0-180-530 85 85 Tsimshatsui, Kowloon
Fax: 1(800) 737-7018 English Tel: (
a
49) 0-180-532 78 32 Hong Kong
Fran3ais Tel: (
a
49) 0-180-532 93 58 Tel: (852) 2737-1600
Italiano Tel: (
a
49) 0-180-534 16 80 Fax: (852) 2736-9960
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.
Obsolete
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TIs terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TIs standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic."Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products Applications
Audio www.ti.com/audio Communications and Telecom www.ti.com/communications
Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers
Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps
DLP®Products www.dlp.com Energy and Lighting www.ti.com/energy
DSP dsp.ti.com Industrial www.ti.com/industrial
Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical
Interface interface.ti.com Security www.ti.com/security
Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense
Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive
Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video
RFID www.ti-rfid.com
OMAP Mobile Processors www.ti.com/omap
Wireless Connectivity www.ti.com/wirelessconnectivity
TI E2E Community Home Page e2e.ti.com