Solid-state Twin Timer H3DE-F
Operates in flicker-OFF or flicker-ON start mode
with one Unit.
Independent ON- and OFF-time settings.
Combinations of long ON- or OFF-time and short
OFF- or ON-time setting are possible.
Long
time range from
0.1 s to 12 h for both ON and
OFF time settings.
Ordering Information
Operating
mode Supply voltage
Model
Flicker-OFF/Flicker-ON start
24 to 230 V
AC/VDC H3DE-F
Model Number Legend
H3DE - 1
1. F: Twin
timers
Accessories (Order Separately)
Mounting
T
rack
50 cm (l) x 7.3 mm (t)
PFP-50N
1 m (l) x 7.3 mm (t)
PFP-100N
1 m (l) x 16 mm (t)
PFP-100N2
End Plate
PFP-M
Spacer PFP-S
H3DE-F H3DE-F
15
Specifications
General
Item H3DE-F
Operating
mode
Flicker-OFF/Flicker-ON start
Operating/Reset method
T
ime-limit operation/T
ime-limit reset or self-reset
T
erminal block
Clamps two 2.5 mm
2
max. bar terminals without sleeves
T
erminal screw tightening torque
0.98 N
S
m max. {approx. 10 kgf
S cm max.}
Output type Relay: SPDT
Mounting method DIN track mounting
Attachment Nameplate
Approved standards
UL508, CSA 22.2 No.14
Conforms to EN61812-1 (VDE0435/P2021), IEC60664-1 (VDE01
10) 4 kV/2, VDE0106/P 100
Conforms to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)
Conforms to EN50081-1 and EN50082-2
Time Ranges
Time
scale display
(t1)
T
ime unit display
escaedspay
(see note 1)
sec
10 s
min hrs
x 0.1
0.1 to 1.2 s
1 to 12 s
0.1 to 1.2 min 0.1 to 1.2 h
x 1
1 to 12 s
10 to 120 s
1 to 12 min 1 to 12 h
Note: 1. T
ime scale display is applied commonly for ON and OFF time.
2.
When the main dial is set to “0” for all settings, the output will operate instantaneously
.
Ratings
Rated
supply voltage (see note)
24 to 230 V
AC/VDC (50/60 Hz)
Operating voltage range
85% to 1
10% of rated supply voltage
Power reset
Minimum power-off time: 0.1 s
Reset voltage
2.4 V
AC/DC max.
Power consumption
AC:
Approx. 3.1 V
A (1.8 W) at 230 V
AC
DC:
Approx. 0.8 W at 24 VDC
Control output
Contact output:
5 A at 250 V
AC with resistive load (cosφ
= 1)
5 A at 30 VDC with resistive load (cos
φ
= 1)
Ambient temperature
Operating: –10°
C to 55
°
C (with no icing)
Storage: –25°
C to 65
°
C (with no icing)
Ambient humidity
Operating:
35% to 85%
Note:
DC ripple rate: 20% max.
H3DE-F H3DE-F
16
Characteristics
Accuracy
of operating
time ±
1% max. of FS (
±
1%
±
10 ms max. at 1.2-s range)
Setting error ±
10%
±
0.05 s max. of FS
Influence of voltage
±
0.5% max. of FS (
±
0.5%
±
10 ms max. at 1.2-s range)
Influence of temperature
±
2% max. of FS (
±
2%
±
10 ms max. at 1.2-s range)
Insulation resistance
100 M
min. at 500 VDC
Dielectric strength
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC (50/60
Hz) for 1 min.
Between control output terminals and operating circuit: 2,000 V
AC (50/60 Hz) for 1 min.
Between contacts not located next to each other: 1,000 V
AC (50/60 Hz) for 1 min.
Impulse withstand
voltage
3 kV (between power supply terminals)
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Noise immunity
Square-wave noise generated by noise simulator (pulse width: 100 ns/1
µs, 1-ns rise) ±
1.5 kV
Static immunity
Malfunction: 4 kV
Destruction: 8 kV
V
ibration resistance
Malfunction:
0.5-mm single amplitude at 10 to 55 Hz
Destruction:
0.75-mm single amplitude at 10 to 55 Hz
Shock resistance
Malfunction:
100 m/s
2
(approximately 10G)
Destruction:
1,000 m/s
2
(approximately 100G)
Life expectancy
Mechanical:
10 million operations min. (under no load at 1,800 operations/h)
Electrical:
100,000 operations min. (5 A at 250 V
AC, resistive load at 360 operations/h)
EMC (EMI): EN50081-1
Emission Enclosure: EN55022 class B
Emission AC Mains:
EN55022 class B
Harmonic Current:
EN61000-3-2
V
oltage Fluctuation and Flickering:
EN61000-3-3
(EMS): EN50082-2
Immunity ESD:
EN61000-4-2:
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio W
aves:
ENV50140: 10 V/m (80 MHz and 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio W
aves:
ENV50204: 10 V/m (900
±
5 MHz) (level 3)
Immunity Conducted Disturbance:
ENV50141: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:
EN61000-4-4:
2 kV power line (level 3)
2 kV I/O signal line (level 4)
Enclosure rating
IP30 (IP20 for terminal block)
Weight
Approx. 1
10 g
Note:
For reference:
A maximum current of 0.15 A can be switched at 125 VDC (cos
φ=1).
A maximum current of 0.1 A can be switched if L/R is 7 ms.
In both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).
H3DE-F H3DE-F
17
Nomenclature
Time scale display window
Time scale selector
(select 0.1 or 1)
Output ON indicator (orange)
Output OFF indicator (green)
Nameplate for user use (20 x 5.4 mm white panel)
ON-time unit display window
Time unit selector
(select one from s, 10s, min, or h for output ON)
ON-time setting dial
OFF-time setting dial
OFF-time unit display window
ON/OFF start selector
(default is flicker-OFF start)
OFF-time unit selector
(select one from s, 10s, min, or h)
(Front View)
(Bottom View)
ON/OFF
Start Selector Switch Settings
Setting
Operating mode
Flicker-ON start
Flicker-OFF start
Operation
Block Diagram
AC (DC)
input
Power
supply
circuit
ON
indicator OFF
indicator
Indicator
circuit
ROM RAM Clock
One-chip microcomputer Output
circuit
Time unit
selector
Operation mode
selector
H3DE-F H3DE-F
18
I/O Function
Inputs ---
Outputs Control output
Outputs are turned ON/OFF according to the time set by the ON-and OFF-time setting dial.
Basic Operation
Time Unit Selection
The
time unit display window for output ON is located
on the upper-
right
side of the front panel above the corresponding
time unit selec
-
tor.
The
time unit display window for output OFF is located on the
lower-
right side of the front panel
below
the corresponding time unit selec
-
tor.
According
to the setting of each time unit selector
, “sec” for seconds,
“10s”
for 10 seconds, “min” for minutes, or “hrs” for hours will appear
in
the corresponding time unit display window
.
ON-time unit display window
ON-time unit selector (select
one from s, 10s, min, or h)
OFF-time unit selector (select
one from s, 10s, min, or h)
OFF-time unit display window
Time Scale Selection
The
time scale selector on the upper-left side of the
front panel can
be
set to 0.1 or 1 as a magnification coef
ficient.
Time scale display window
Time scale selector
ON-time setting
dial
OFF-time setting dial
Time Setting
Use
the ON/OFF-time setting dial to set the ON/OFF time.
Timing Charts
Operating
mode Timing
chart
Flicker-OFF
start
tON: ON set time
tOFF: OFF set time
ON
OFF
0.1 s min.
ON
OFF
ON
OFF
ON
OFF
Power (A1 and A2)
Output relay: NO
15 and 18
(ON indicator)
Output relay: NC
15 and 16
OFF indicator
Flicker-ON
start
tON
: ON set time
tOFF: OFF set time
0.1 s min.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Power (A1 and A2)
Output relay: NO
15 and 18
(ON indicator)
Output relay: NC
15 and 16
OFF indicator
Note: 1. The
reset time requires a minimum of 0.1 s.
2. When
power is supplied in flicker-ON start mode, the OFF
indicator lights momentarily
. This, however
, has no ef
fect on the perfor
-
mance
of the T
imer.
H3DE-F H3DE-F
19
Dimensions
H3DE-F
Terminal block (black)
Surface color:
Light gray 5Y7/1
(OMRON)
Terminal block (black)
Installation
Terminal Arrangement
Note: DC
supply voltage does not require the designation of polarity
.
H3DE H3DE
32
Accessories (Order Separately)
Note: The undermentioned is common for all H3DE models.
Note: All
units are in millimeters unless otherwise indicated.
Dimensions
Mounting Track
PFP-100N, PFP-50N PFP-100N2
L:
Length
1 m
PFP-100N
50 cm
PFP-50N
1 m
PFP-100N2
End Plate
PFP-M Spacer
PFP-S
4.5
15 25 25 25 25 *
10 10
L
7.3±0.15
35±0.3 27±0.15
1
4.5
15 25 25 25 25 15
10 10
L
35±0.3 27 24
16
29.2
1 1.5
50
11.5 M4
x 8
pan head
screw
10
6.2 1.8
135.5 35.3
1.8
1.3
4.8
516
12
44.3
16.5
10
34.8
H3DE H3DE
33
Precautions
Note: The undermentioned is common for all H3DE models.
Changing of Setting
NOTICE:
Do not change the time unit, time scale, operating mode,
or
output
type selector switch while the T
imer is in opera
-
tion
or malfunction could result.
Mounting and Dismounting
The
H3DE should be mounted as horizontally as possible.
When
mounting the H3DE on a socket mounting track, hook portion
(A)
of the T
imer to an edge of the track first, and then depress the
T
imer in the direction of (B).
(A)
(B)
When dismounting the H3DE, pull out portion (C) with a flat-blade
screwdriver and remove the T
imer from the mounting track.
(C)
30 mm min.
Rail stopper
The
H3DE can be mounted and dismounted with ease if a distance
of 30 mm or more is kept between the
H3DE
and the top surface of
other
equipment located below the H3DE.
Power Supplies
The
H3DE Series is provided
with a transformerless power supply
system. An electric shock may be received if the input terminal or
the
output type selector switch is touched
while power is being sup
-
plied.
Use
the bar terminal for wiring the H3DE. Using a stranded-wire ter
-
minal
may cause a short-circuit due to a stray wire entering into the
Timer.
Both AC and DC power supplies can be connected to the power
in
-
put
terminals without regarding polarity
.
With
the H3DE only, a DC power supply must be connected to
the
power
input terminals as
designated according to the polarity of the
terminals.
A DC power supply can be connected if its ripple factor is 20% or
less and the mean voltage is within the rated operating voltage
range
of the T
imer.
Connect
the power supply voltage through a relay or switch in such
a way that the voltage reaches a fixed value at once or the Timer
may
not be reset or a timer error could result.
For
the power supply of an input device, use an isolating
transform
-
er, of which the primary and secondary windings are mutually iso-
lated and the secondary winding is not grounded.
H3DE Power supply
Circuit
Isolation transformer is required.
Rectifier circuit
Start
input
B1
A1
A2
The H3DE-H has a large inrush current; provide sufficient power
supply
capacity
. If the power
supply capacity is too small, there may
be
delays in turning ON the output.
Installation
If
the load current is continuously being supplied to the
T
imer for a
long period of time, be sure to provide the mounting clearance as
shown in the figure below. If used under the conditions other than
those
specified below
, the life of internal components may be short
-
ened
due to an excessive rise in the internal temperature.
tt
DIN track
t: Mounting clearance (mm)
H3DE H3DE H3DE
H3DE H3DE
34
Switching Current vs. Ambient T
emperature
(When Mounting T
wo or More H3DE Units Side-by-Side)
Ambient temperature ( C)
(Measurement Condition: Input voltage of 230 V
AC)
01 2 34 5
70
60
50
40
30
20
Load current (A)
Mounting
clearance:
0 mm
Mounting
clearance: 5 mm
Mounting
clearance: 10 mm
Maximum range of
operating ambient
temperature
°
Mounting clearance:
50 mm min.
Input/Output
Relationship between Input and Power Supply
Circuits
Input circuit Power supply
circuit
AC/DC
power
supply
A1B1
A2
Since the input circuit and the power supply circuit are configured
independently,
the input circuit can be turned on or of
f irrespective of
the
on/of
f state of the power supply
.
It
must be noted that a voltage equivalent to the power supply volt
-
age
is applied to the input circuit.
When
connecting a relay or a transistor as an external signal input
device,
pay attention to the following points to prevent short-circuit
-
ing
due to a sneak current to the transformerless power supply
.
If
a relay or transistor is connected to two or more T
imers, the input
terminals
of those T
imers must be wired properly so that they will not
be different in phase or the terminals will be short-circuited to one
another
(refer to the figures below).
Incorrect
Contact
or transistor for
external input signal
Correct
H3DE Power supply
B1
A1
A2
H3DE
B1
A1
A2
Short-circuit
current
Contact or transistor for
external input signal
H3DE Power supply
B1
A1
A2
H3DE
B1
A1
A2
Short-circuit
current
The
H3DE Series is provided
with a transformerless power supply
system.
Input Wires
The
input wires
must be as short as possible. If the floating capacity
of
wires exceeds 2,000 pF (approx. 17 m for cables with 120 pF/m),
the
operation will be af
fected. Pay particular
attention when using
shielded
cables.
Wiring (H3DE-H)
The
H3DE has a high impedance circuit. Therefore, the H3DE
may
not
be reset if the H3DE is influenced by inductive voltage. In order
to
eliminate any influence of inductive voltage, the wires connected
to the H3DE must be as short as possible and should not be
installed
alongside power lines.
If the H3DE is influenced by induc
-
tive
voltage that is 30% or more of the rated voltage, connect a CR
filter
with a capacitance of approximately 0.1
µ
F and a resistance
of
approximately
120
or a bleeder resistor between the power sup
-
ply
terminals. If there is any residual voltage due
to current leakage,
connect
a bleeder resistor between the power supply terminals.
H3DE H3DE
35
Operation (H3DE-H)
An
interval of 3 s minimum is required to turn on the H3DE after the
H3DE is turned of
f. If the H3DE is turned on and of
f repeatedly with
an interval of shorter than 3 s, the internal parts of the H3DE may
deteriorate
and the H3DE may malfunction.
Power
Output
state
1
3 s min.
Output
state 2
If
it is required that the output be turned
on repeatedly with an inter
-
val
of shorter than 3 s, consider use of
the H3DE-M2/-M1 in mode D
(signal OFF-delay).
Precautions for VDE Conformance
The
H3DE as a built-in timer conforms to VDE 0435/P2021 provided
that
the following conditions are satisfied:
The
output section of the H3DE is provided only with basic isolation.
To
ensure reinforced
isolation required by the VDE standards, pro
-
vide supplementary basic isolation on the load side connected to
the
output.
The H3DE itself is designed according to the following:
Overvoltage category III
Pollution degree 2
On the above basis:
Operation parts on the front and bottom: Reinforced isolation
With clearance of 5.5 mm and creepage distance of 5.5 mm at
230 V
AC
Output:
Basic isolation
With clearance of 3 mm and creepage distance of 3 mm at
230 V
AC
Environment
When
using the
T
imer in an area with excess electronic noise, sepa
-
rate
the T
imer
, wiring, and the equipment which generates the input
signals
as far as
possible from the noise sources. It is also recom
-
mended
to shield the input signal wiring to prevent electronic inter
-
ference.
Organic solvents (such as paint thinner), as well as very acidic or
basic
solutions can damage the outer casing of the T
imer.
Do
not use the T
imer in places where it is exposed to dust, corrosive
gas,
or direct sunlight.
When storing the Timer, make sure that the ambient temperature
and
humidity are within the rated values. Leave the
T
imer at room
temperature
for at least three hours before using the T
imer if it
has
been
stored at an ambient temperature of –10
°
C or below
.
Others
If
the T
imer is mounted on a control board, dismount the T
imer
from
the control board or short-circuit the circuitry of the power board be
-
fore carrying out a voltage withstand test between the electric cir-
cuitry and non current-carrying metal part of the Timer, in order to
prevent
the internal circuitry of the T
imer from damage.
It must be noted that although the electrical life expectancy of the
H3DE
T
imer shown in the catalog is the same as the H3DR T
imer
shown in the catalog, the actual performance varies because the
built-in
relays are different as follows:
Built-in relay for the H3DR:
G2R; 100,000 operations min.
(10 A for SPDT and 5 A for DPDT at
250 VAC, resistive load at
1,800 operations/h.)
Built-in
relay for the H3DE:
G6RN; 50,000 operations min.
(8 A at 250 VAC, resistive load at
360 operations/h.)
H3DE H3DE
36
OMRON Corporation
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To
convert millimeters into inches, multiply by 0.03937. T
o convert grams into ounces, multiply by 0.03527.
Cat. No. L092-E1-3D In the interest of product improvement, specifications are subject to change without notice.
Printed
in Japan
1
199-2M
a
Industrial Automation Company
Measuring and Supervisory Controls Division
28th Fl., Crystal T
ower Bldg.,
1-2-27, Shiromi, Chuo-ku,
Osaka 540-6028 Japan
T
el: (81)6-6949-6035 Fax: (81)6-6949-6069