Tyco Electronics Identification HX-SCE - High Performance Low Fire Hazard Identification Solution Features and Benefits Low Fire Hazard Properties, Low Smoke, Low Toxicity, Low Flammability:- Meets Industry Standard BS 6853 (1999) Vehicle Category 1a Superb Print Quality to give Crisp Clear Identification Marker Sleeve Excellent Print Permanence when tested in Demanding Industry Related Fluids Choice of Printer Options Sleeve Diameters from 2.4mm to 38.1mm Sleeves are Printable on Both Sides for ease of Identification or Addition of Additional Information to the Marker Sleeve Shrink Ratio of 2:1 Recovers to Half of the Original Diameter Thin wall, zero-halogen, low cables by computer-based make this product ideal for smoke, low toxicity, radiation printing onto sleeves. Ideal use in enclosed spaces cross-linked, UV stabilised for where such as mass transit, marine polyolefin heat-shrinkable limited fire hazard charac- and industrial installations. tubing, assembled as cut teristics are critical. This sleeves organised in a zero ladder format. coupled with low smoke and relief Identification of wires and low toxic fume emissions required. applications halogen The material product is recommended where strain properties Industries featured in: Marine Rail Industrial Literature No. 1773110 Revised 06-05 Dimensions are shown for reference purposes only. Conversion Rate: 25.4mm = 1 inch Dimensions are in inches and millimetres unless otherwise specified. Values in brackets are metric equivalents. Specifications subject to change. not www.tycoelectronics.com are Tyco Electronics Identification HX-SCE - High Performance Low Fire Hazard Identification Solution Ordering Information 1.970 Min (50.0) D d Available Sizes and Formats Ordering Description D (min) d (max) as Supplied after Recovery Recommended Use Range mm inches mm inches mm inches HX-SCE-1K-2.4-50- 2.40 0.094 1.19 0.047 1.27-1.90 0.050-0.075 HX-SCE-1K-3.2-50- 3.20 0.126 1.58 0.060 1.75-2.66 0.069-0.105 HX-SCE-1K-4.8-50- 4.80 0.189 2.36 0.090 2.54-4.06 0.100-0.160 HX-SCE-1K-6.4-50- 6.40 0.250 3.18 0.125 3.81-5.46 0.150-0.215 HX-SCE-1K-9.5-50- 9.50 0.375 4.75 0.187 5.59-8.12 0.220-0.320 HX-SCE-1K-12.7-50- 12.70 0.500 6.35 0.250 6.99-10.79 0.275-0.425 HX-SCE-1K-19.0-50- 19.00 0.730 9.53 0.375 10.16-16.25 0.400-0.640 HX-SCE-1K-25.4-50- 25.40 1.000 12.7 0.500 14.29-21.59 0.563-0.850 HX-SCE-1K-38.1-50- 38.1 1.500 19.05 0.750 20.95-33.02 0.825-1.300 Options Prescoring Package sizes Perforated score to produce multiple marker sleeves from each HX-SCE sleeve Number of prescores: 1 prescore 2 prescores 3 prescores Code: S1 S2 S3 Standard: 1K - 1000 piece packages available for all HX-SCE sizes Non Standard: 250 piece packages available for all HX-SCE sizes 2.5K - 2500 pieces available for 4.8 and 6.4 HX-SCE sizes 5K - 5000 pieces available for 2.4 and 3.2 HX-SCE sizes Colours Standard: Non Standard: Ordering information: Yellow White 4 9 Red Orange Green Blue 2 3 5 6 Reference pack size, product diameter, sleeve length, prescores and colour then reference part numbering system Literature No. 1773110 Revised 06-05 Dimensions are shown for reference purposes only. Conversion Rate: 25.4mm = 1 inch Dimensions are in inches and millimetres unless otherwise specified. Values in brackets are metric equivalents. Specifications subject to change. www.tycoelectronics.com Tyco Electronics Identification HX-SCE - High Performance Low Fire Hazard Identification Solution Industry Standards Standard Title Application BS6853 Code of practice for fire precautions in the design Interior minor use materials of mass 100g to 500g. and construction of passenger carrying trains Vehicle category la Fire Safety Performance of Materials Limited, Dispersed usage (abbreviation RS/EQ/I) NF F 16-101 Railway Rolling Stock Fire behavior choice of materials Rolling Stock Classification A1 DIN 5510-2 Preventive fire protection in railway vehicles - Part 2: Fire Dripping Classification ST2 1 London Underground Limited Standard 2-01001-002 behavior and fire side effects of materials and parts; Classification, Requirements and test methods 2 EN50343 Railway Applications - Rolling Stock - Tests on marking when using heat-shrinkable sleeves Rules for installation of cabling 1 This replaces LUL Engineering Standard E 1042 2 Not including resistance to liquid fuel - not recommended for use in areas where the sleeves may be subject to extended contact from diesel fuel Tyco Electronics D-SCE product range is designed for use in these areas Technical Information Print Method/Ribbon: T312M-PRINTER with 1966-RIBBON or Toxicity (continued): T212M-PRINTER with T200-1966-RIBBON Service Temperature: Toxicity Index = 0.34 (CEI 20-37-7 09-1997 Determination of toxicity index of gases from combustion -30C to +105C (-22F to +221F). of organic material) Minimum Shrink Temperature: 135C (275F). Colours: White or yellow. Dielectric Strength: Other colours available on request. Water Absorbsion: 15kV/mm minimum. 1% maximum after 24 hours at 23C (73F). Flammability: Self-extinguishing Copper Mirror Corrosion: (ASTM D2671 Procedure B). 8% maximum after 16 hours at 150C (302F). Oxygen Index (BS6853: Pass 34% Min.) Longitudinal Change: +5% to -10%. Tensile Strength: 7MPa minimum. Ultimate Elongation: 80% minimum. Secant Modulas: 200MPa maximum at 2% elongation. Smoke Index Determination (IF) UV Resistance: Tensile strength > 90% & Ultimate Maximum 20, Smoke Class F1 - (base polymer) (BS EN ISO 4589-2 [1999]). (AFNOR NF F 16-101 Class I2). Dripping Classification ST2 - (DIN 5510-2) Smoke: A0=0.017 Max. - (BS 6853 [1999] Annex D [D.8.3]) Small scale test (AFNOR NF F 16-101-1988 Smoke Index) Toxicity: dry cycle]; UVB [8 hours dry/4 hours R < 1 - (BS 6853 [1999] Annex B - wet cycle]). AFNOR NF X 70-100 Determination of weighted summation of toxic fume, mass elongation > 40% of original value after 1000 hours (ASTM G53: UVA [100% Print Permanence: ADHERENCE - Meets the requirements based method) of SAE AS81531 4.6.2 (50 rubs). LUL Toxic Fume: No Halogens, No P, S FLUID RESISTANCE - Meets the or N sources above trace level - requirements of MIL-STD-202F method (LUL E1042: A6 [2002]). 215J. (London Underground Standard 2-01001-002, section 5.2.3. Chemical composition / toxicity) Literature No. 1773110 Revised 06-05 Dimensions are shown for reference purposes only. Conversion Rate: 25.4mm = 1 inch Dimensions are in inches and millimetres unless otherwise specified. Values in brackets are metric equivalents. Specifications subject to change. www.tycoelectronics.com Tyco Electronics Identification HX-SCE - High Performance Low Fire Hazard Identification Solution Fluid Resistance Threat Test Effect Xylene/butylacetate/cyclohexanone mix (Paint stripper) 10 wipes dry tissue Print Contrast >/8 Locomotive diesel 10 wipes dry tissue Print Contrast >/8 Tunnel dust/white spirits LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8 Water LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8 Tunnel Dust and Oil (50% / 50%) LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8 Tunnel Dust and Water (50% / 50%) LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8 White Spirits LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8 Diesel LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8 Grease LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8 Glycol rail de-icer (50% glycol / 50% water) LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8 Cleaning solvent LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8 Surface Cleaner (PGP500) LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8 Multi-Purpose Graffiti remover gel LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8 CGR gel (Chewing gum remover) LUL C3349 (72 hours, 20 strokes dry tissue) Print Contrast >/8 IRM 902 oil EN50343 (70 hours at 50C(122F) 10 wipes) Print Contrast >/8 Hydrochloric acid 5% solution EN50343 (1 minute at 23C(73F) 10 wipes) Print Contrast >/8 Sodium Hydroxide 5% solution EN50343 (1 minute at 23C(73F) 10 wipes) Print Contrast >/8 Heat aging EN50343 (240 hours at 120C (248F) 10 wipes) Print Contrast >/8 Wash cycle test 25 cycles at 75C (167F) 25 wipes Print Contrast >/8 Aircraft fuel (ISO 1817 Liquid B) 24 hours at 40C (104F) then 25 strokes dry tissue; Print Contrast >/8; IEC 60684-2 4MPa TS & 90% UE retained 24 hours at 50C (122F) then 25 strokes dry tissue; Print Contrast >/8; IEC 60684-2 4MPa TS & 90% UE retained 24 hours at 23C (73F) then 25 strokes dry tissue; Print Contrast >/8; IEC 60684-2 4MPa TS & 90% UE retained 24 hours at 23C (73F) then 25 strokes dry tissue; Print Contrast >/8; IEC 60684-2 4MPa TS & 90% UE retained 24 hours at 23C (73F) then 25 strokes dry tissue; Print Contrast >/8; IEC 60684-2 4MPa TS & 90% UE retained Silicone fluid (S1714) Propan-2-ol De-icing fluid (50% ethylene glycol) Sullage fluid (formaldehyde/cresol) Part Numbering System HX-SCE- 1K-4.8-50-S1- 4 Product Large Packaging (optional) Size Sleeve Length (mm) Scoring Colour All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale. Tyco is a trademark. Other respected brands include Agastat, Alcoswitch, AMP, AMP Netconnect, Buchanan, CII, CoEv, Critchley, Elcon, Elo TouchSystems, M/A-COM, Madison Cable, OEG, Potter & Brumfield, Raychem, Schrack, Simel and TDI Batteries. Literature No. 1773110 Revised 06-05 Dimensions are shown for reference purposes only. Conversion Rate: 25.4mm = 1 inch Dimensions are in inches and millimetres unless otherwise specified. Values in brackets are metric equivalents. Specifications subject to change. www.tycoelectronics.com