RS010285
\QR0405 REV.:1.3
SUNPOWER TECHNOLOGY CORP.
SPECIFICATIONS OF SWITCHING POWER SUPPLY
MODEL NO.: SDS-030B3.3 REV.:1.3
SDS-030B05
SDS-030B12
SDS-030B24
SDS-030B48
(UL/cUL/TUV STANDARD)
STAMP APPROVED CHECK PREPARE
MODEL NO.: SDS-030B SER. REV.: 1.3 UL/cUL/TUV STANDARD RS010285
2/3 2001/09/27
1. DC INPUT :
1-1.VOLTAGE :
18V (MIN.) - - - 36V (MAX.)
1-2. CURRENT :
2.6A MAX. AT 19V INPUT, FULL LOAD CONDITION.
2. DC OUTPUT :
MODEL NO.: SDS-030B3.3 SDS-030B05
VOLTAGE +3.3 V +5 V
MAX. LOAD 7 A 6 A
REGULATION ±
±±
±3% ±
±±
±2%
OVP +3.8V~+4.6V +5.8V~+7.0V
RIPPLE & NOISE (MAX.) 40mV 50mV
EFFICIENCY (MIN.) 68% 70%
MODEL NO.: SDS-030B12 SDS-030B24 SDS-030B48
VOLTAGE +12 V +24 V +48 V
MAX. LOAD 2 .5A 1.3 A 0.65 A
REGULATION ±
±±
±1% ±
±±
±1% ±
±±
±1%
OVP +13.8V~+17.5V +27.6V~+33.6V +55.2V~+67.2V
RIPPLE & NOISE (MAX.) 100mV 200mV 250mV
EFFICIENCY (MIN.) 74% 76% 78%
3. ELECTRONIC CHARACTERISTICS :
3-1. RISE TIME :
20mS MAX.
3-2. SHORT CIRCUIT PROTECTION :
WHEN OUTPUT SHORT TO GROUND, THE POWER SUPPLY WILL SHUTDOWN,
AND AUTO RECOVERY WHEN SHORT CIRCUIT BE REMOVE.
5. MECHANICAL DATA :
OUTLINE DIMENSION : W82 ×L99 ×H35 mm
4. COOLING:
NATURAL COOLING.
MODEL NO.: SDS-030B SER. REV.: 1.3 UL/cUL/TUV STANDARD RS010285
3/3 2001/09/27
6. SAFETY :
THIS PRODUCT IS DESIGN TO COMPLY WITH THE FOLLOWING STANDARDS :
6-1. UL 60950 3rd EDITION (2000) STANDARD.
6-2. CSA C22.2 NO.60950 3rd EDITION (2000) STANDARD.
6-3. TUV EN 60950 3rd EDITION (2000) STANDARD.
6-4. IEC 60950 3rd EDITION (1999) STANDARD.
6-5. EMKO-TSE (74-SEC) 207/94 STANDARD.
7. EMC :
THIS PRODUCT IS DESIGN TO COMPLY WITH THE FOLLOWING STANDARDS :
7-1. EMI
(1) . FCC CFR 47 PART 15 SUBPART J , CLASS B LIMIT
(2) . EN 50081-1:1997 EMISSION STANDARD
EN 55022: 1997 CLASS B LIMIT
(3) . CNS 13438 CLASS B.
7-2. EMS
(1) . EN 50082-1 (1997) IMMUNITY STANDARD:
EN 61000-4-2 : 1995 ELECTROSTATIC DISCHARGE STANDARD.
EN 61000-4-3 : 1996 RADIATED RF STANDARD.
EN 61000-4-4 : 1995 FAST TRANSIENT/BURST STANDARD.
EN 61000-4-5 : 1995 LIGHTNING SURGE STANDARD.
EN 61000-4-6 : 1996 CONDUCTED RF STANDARD.
EN 61000-4-8 : 1993 POWER FREQ. MAG. FILELD STANDARD.
8. PHYSICAL ENVIRONMENT (AMBIENT) :
8-1. TEMPERATURE RANGE :
OPERATING TEMPERATURE RANGE : 0 ~ 70
DERATING FACTOR 50~ 70 : 2.5%/℃
STORAGE -10 TO +75
8-2. HUMIDITY :
OPERATION 20% TO 85% RH. (NON CONDENSING)
STORAGE AND SHIPPING 10% TO 95% RH. (NON CONDENSING)
9.M.T.B.F.:
417K HOURS APPROXIMATELY, ACCORDING TO MIL-HDBK-217F AT 25
ENVIRONMENT.