Power Protection and Conditioning MCR Portable Series - Power Line Conditioning with Voltage Regulation The MCR provides excellent noise filtering and surge protection to protect connected equipment from damage, degradation or misoperation. Combined with the excellent voltage regulation inherent to SolaHD's ferroresonant design, they can increase the actual Mean Time Between Failure (MTBF) of protected equipment. These units are a perfect choice where dirty power caused by impulses, swell, sags, brownouts and waveform distortion can lead to costly downtime because of damaged equipment. Applications * Computers/ Printers * Telephone/FAX systems * POS terminals * Security systems * Laboratory equipment * LAN networks Features * 3% output voltage regulation * Noise attenuation - 120 dB common mode - 60 dB transverse mode * Surge protection tested to ANSI/IEEE C62.41 Class A & B waveform (<10 V let-through typical) * Harmonic filtering * Galvanic isolation provides exceptional circuit protection. * Point-of-use protection (cord & plug connected) - Easy & Flexible Installation * 25 year typical MTBF * No maintenance required E47379 LR044950 Certifications and Compliances All Models * RoHS Compliant * Listed - UL 1012 Select Models * Listed (1500VA Units) - UL 1012, CSA C22.2 No. 66 * Certified (70VA-1kVA Units) - CSA C22.2 No. 66 Related Products * DIN Rail AC UPS (SDU) * Off-Line UPS (S1K Mini-Tower) * Line-Interactive UPS (S3K Mini-Tower) Selection Tables: Single Phase Group A - MCR Portable Series, 60 Hz VA Catalog Number Voltage Input/Output Height in (mm) Width in (mm) Depth in (mm) Ship Weight lbs (kg) Receptacle (No.) Type (NEMA) Plug (NEMA) 70 63-13-070-6 120 6.00 (152.4) 7.00 (177.8) 9.00 (228.6) 18.0 (8.16) (4) 5-15R 5-15P 150 63-13-115-6 120 6.00 (152.4) 7.00 (177.8) 9.00 (228.6) 21.0 (9.53) (4) 5-15R 5-15P 250 63-13-125-6 120 6.00 (152.4) 7.00 (177.8) 9.00 (228.6) 26.0 (11.79) (4) 5-15R 5-15P 500 63-13-150-6 120 9.00 (228.6) 9.00 (228.6) 16.00 (406.4) 32.0 (14.51) (4) 5-15R 5-15P 750 63-13-175-6 120 9.00 (228.6) 9.00 (228.6) 16.00 (406.4) 64.0 (29.03) (4) 5-15R 5-15P 1000 63-13-210-6 120 9.00 (228.6) 9.00 (228.6) 16.00 (406.4) 69.0 (31.30) (4) 5-15R 5-15P 1500* 63-13-215-6 120 11.00 (279.4) 11.00 (279.4) 17.00 (431.8) 95.0 (43.09) (6) 5-15R 5-20P 2000 63-13-220-6 120 11.00 (279.4) 11.00 (279.4) 17.00 (431.8) 115.0 (52.16) (4) 5-15R, (1) L5-30R L5-30P 3000* 63-13-230-6 120 11.00 (279.4) 11.00 (279.4) 17.00 (431.8) 143.0 (64.86) (4) 5-15R, (1) L5-30R 5-50P * * 48 Only Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 Power Protection and Conditioning Specifications Parameter Condition Value Input Voltage Current Continuous at full load (lower input voltage possible at lighter load) +10% to -20% of nominal For temporary surge or sags +20% to -35% of nominal Iin (VA/.89)/(Vin x 80%) At Full Load & 80% of nominal input voltage 1 See Operating Characteristics section for details. Frequency 60 Hz depending on model Output 1 Line Regulation 3% for 60 Hz units Vin >80% and <110% of nominal Overload Protection At Nominal Input Voltage Output Harmonic Distortion At full load within input range Current limited at 1.65 times rated current Noise Attenuation -Common Mode -Transverse Mode Let-Through ANSI/IEEE C62.41 Class A & B Waveform 3% total RMS content 120 dB 60 dB <10V typical General Efficiency At Full Load Storage Temperature Humidity <95% non-condensing 92% Typical Operating Temperature Humidity <95% non-condensing Audible Noise Full Resistive Noise -20 to +85C -20 to 40C 35 dBA to 65 dBA 10 + 2 year limited warranty Warranty Notes: 1 - It is recommended that the unit run at a minimum of 40-50% load. Back Panels Plug & Receptacle Reference Chart 5-15P 60 Hz, 70 - 1000 VA, (4) 5-15R Receptacles 5-15R L5-30P 60 Hz, 2000-3000 VA, (4) 5-15R and (1) L5-30R Receptacle Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 49 Power Protection and Conditioning Model Comparison Description VA Ratings Hardwired CVS Hardwired MCR Portable MCR 30 to 7500 VA 120 to 15000 VA 70 to 3000 VA +10/-20% of nominal Input Voltage Range Voltage Regulation 1% for an input line variation of +10/-20%. No loss of output for line loss of 3 msec. Limits output current to 1.65 x rated current at nominal input. Overload Output Harmonic Distortion 3% total RMS content at full load. 40 dB common and normal code. 120 dB common mode and 60 dB normal mode. Up to 6000 Volt surges are suppressed to a let through of less than 1% per ANSI/IEEE C62.41 Class A & B waveforms. ANSI/IEEE C62.41 Class A & B 6000 waveforms are suppressed to a let-through of less than 0.2%. Noise Isolation Surge Protection 3% for an input line variation of +10/-20% (50 Hz hardwired units 5%.) No loss of output for complete line loss of 3 msec. Efficiency Operating Temperature Up to 92% at full load Up to 90% at full load -20oC to 50oC -20oC to 40oC 32 dB to 65 dB Audible Noise 35 dB to 65 dB 34 dB to 49 dB 10 year limited warranty Warranty Note: All values are typical and may vary based on VA ratings of actual units. BTU Output Chart for CVS and MCR Series VA Ratings 120 250 500 750 1000 1500 2000 3000 5000 7500 10000 15000 Total BTUs 136 225 280 444 519 686 1229 1331 2117 2407 3209 4813 Note: Ratings are for a 40oC ambient temperature. 50 Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) January 2017 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Sola/Hevi-Duty: 63-13-125-6 63-13-230-6 63-13-215-6 63-13-150-6 63-13-175-6 63-13-070-6 63-13-210-6 63-13-115-6 63-13220-6