AC Power Transducer DIN RAIL / PANEL MOUNT, ACTIVE / REACTIVE The CR6200 Series, Power Transducers and Transmitters are designed to provide a controlled output that is proportional to the average power. These devices are specifically targeted to provide an efficient solution to most power sensing needs. Units are designed for operation in systems with sinusoidal voltage and current wave forms. Applications Energy Management Motor Efficiency Multi-point power sensing Remote power sensing over long distances CR6210 CR6211 CR6220 CR6221 Features 35mm DIN Rail or Panel Mount Ranges available for any power sensing need Active and Reactive power sensing 0 - 5 VDC and 4 - 20 mADC outputs Connection diagram printed on case Transducers C Regulatory Agencies Approved to UL3111-1, First Edition, Amendment 2 Approved to CAN/CSA-C22.2, No. 1010.1-92 Meets requirement of IEC 61010-1 and BS EN 61010-1 CR6230 CR6231 CR6240 CR6241 E199795 CR6250 CR6251 CR6260 CR6261 V CR Magnetics has a wide selection of current and potential transformers to extend the range of any part. See Sections G & H for details. I - ACTIVE POWER - REACTIVE POWER POWER TRANSDUCERS CAN BE ORDERED TO MEASURE ACTIVE OR REACTIVE POWER CR Magnetics, Inc. 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com Another HUNTINGTON ELECTRIC Company 46 E-mail: sales@crmagnetics.com AC Power Transducer DIN RAIL / PANEL MOUNT, ACTIVE / REACTIVE Add suffix for input range - PART NUMBERS CR6210 CR6211 CR6220 CR6221 CR6230 CR6231 CR6240 CR6241 CR6250 CR6251 CR6260 CR6261 - - 1 Phase, Active Power with 0 - 5 VDC Output 1 Phase, Reactive Power with 0 - 5 VDC Output 1 Phase, Active Power with 4 - 20 mADC Output 1 Phase, Reactive Power with 4 - 20 mADC Output 3-Phase, 3-Wire, Active Power with 0 - 5 VDC Output 3-Phase, 3-Wire, Reactive Power with 0 - 5 VDC Output 3-Phase, 3-Wire, Active Power with 4 - 20 mADC Output 3-Phase, 3-Wire, Reactive Power with 4 - 20 mADC Output 3-Phase, 4-Wire, Active Power with 0 - 5 VDC Output 3-Phase, 4-Wire, Reactive Power with 0 - 5 VDC Output 150 250 500 0-150 VAC 0-250 VAC 0-500 VAC * - other ranges available * not UL recognized 5 20 50 - 0-5 AAC 0-20 AAC 0-50 AAC 3-Phase, 4-Wire, Active Power with 4 - 20 mADC Output 3-Phase, 4-Wire, Reactive Power with 4 - 20 mADC Output C SPECIFICATIONS Cleaning:................. Water-dampened cloth Relative Humidity:... 80% for temperatures up to 31C and decreasing linearly to 50% at 40C Supply Current: CR6210:......................Typical 35mA Max 45mA CR6220: Typical 75mA Max 110mA CR6230:......................Typical 50mA Max 70mA CR6240: Typical 75mA Max 110mA CR6250:......................Typical 50mA Max 70mA CR6260: Typical 75mA Max 120mA Torque Specs.:................ 3.0 inch lbs. (0.4Nm) Weight:.............................0.5 lbs. 2.874 (73) 1.42 (36) 0.79 1.22 Sp (20) (31) D 0.14 (3.5) 1 2 9 3 8 4 7 1.06 (26.8) 2.99 3.86 Sp (76) (98) 6 5 2.874 (73) 0.79 1.22 ( ) (31) 1.42 0.20 (5.1) 3.268 (83) (36) 1 hole: 0.79(20) Dia. for CR6210, 6211, 6220 & 6221 (shown) 2 holes: 0.26(6.5) Dia. for CR6230, 6231, 6240, & 6241 3 holes: 0.26(6.5) Dia. for CR6250, 6251, 6260 & 6261 OUTLINE DRAWING NOTE: The building installation must have a switch or circuit-breaker that is in close proximity and within easy reach of the operator. The switch or circuit breaker shall be marked as the disconnecting device for the equipment. CR Magnetics, Inc. 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com Another HUNTINGTON ELECTRIC Company 47 E-mail: sales@crmagnetics.com Transducers Basic Accuracy:......................... 0.5% Thermal Drift:............................ 500 PPM/C Operating Temperature:............ 0C to +60C Installation Category:................. CAT II Pollution Degree:........................2 Response Time: ....................... 250 ms max. 0-90% FS Supply Voltage:......................... 12 to 24 VDC MTBF:............................... Greater than 100 K hours Frequency Range:................. 50 Hz - 400 Hz, sine wave Insulation Voltage:................. 2500 VDC Altitude:................................. 2000 meter max. Output Load:............ 4-20 mADC -0 to 300 0-5 VDC - 2K or Greater AC Power Transducer DIN RAIL / PANEL MOUNT, AVERAGE SENSING N L1 N L1 1 2 3 4 7 6 5 + - - + 1 2 3 4 OUTPUT 1 9 8 9 8 OUTPUT 1 7 6 + LOAD Supply LOAD CR6210 CR6211 CR6220 Single element, 0 - 5 VDC Output Transducers C CR6210 CR6211 L1 L2 CR6221 Single element, 4 - 20 mADC Output CR6220 Single element, 0 - 5 VDC Output with external voltage transformers CR6221 Single element, 4 - 20 mADC Output with external voltage transformers L3 L1 L2 1 2 8 7 9 3 4 OUTPUT 1 - + - 5 CR6231 SUPPLY CR6240 3 element - 3 Wire, 0 - 5 VDC Output + 8 7 6 LOAD SUPPLY LOAD CR6230 2 + - 6 5 L3 1 OUTPUT 1 9 3 4 L1 - 5 SUPPLY CR6241 3 element - 3 Wire, 4 - 20 mADC output L3 L2 1 2 3 4 OUTPUT 1 9 8 7 6 5 + - SUPPLY LOAD CR6230 CR6231 CR6240 3 element - 3 Wire, 0 - 5 VDC Output with external voltage and current transformers L1 L2 L3 3 element - 3 Wire, 4 - 20 mADC Output with external current transformer L1 N 1 2 3 4 9 8 7 6 5 L2 L3 N 1 2 3 4 OUTPUT 1 + CR6241 - + 9 8 7 6 5 SUPPLY OUTPUT 1 + - SUPPLY LOAD LOAD CR6250 CR6251 3 element - 4 Wire, 0 - 5 VDC Output shown with external voltage and current transformers CR6260 CR6261 3 element - 4 Wire, 4 - 20 mADC Output shown with external current transformers CONNECTION DIAGRAMS CR Magnetics, Inc. 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com Another HUNTINGTON ELECTRIC Company 48 E-mail: sales@crmagnetics.com