(0.26")
6.5
(0.44")
11.25
(0.20")
5
(0.06")
1.5
(0.31")
8
(0.63")
16
(0.16")
ˇ4
(1.20")
30.5
(0.91")
23
M20
(0.31")
8
(0.15")
4
(2.44")
62
(0.87")
22
(0.79")
20
(3.94")
100
(1.18")
30
(1.22")
31
0
s
(5.91")
R min. 150
(5.91")
R min. 150
Technical data
Electrical data
Rated insulation voltage Ui max. 250 V AC
Rated operating voltage Ue max. 240 V
Conventional thermal current
(up to) 1
Ithe 10 A
Utilization category
(up to) 1
AC-15, Ue /Ie 240 V / 3 A
Mechanical data
Switching frequency ≤ 30/min.
Mechanical service life Standard
Mechanical service life encreased actuator holding force
1 x 106 switching cycles
1 x 105 switching cycles
B10d
(up to) 1
2 Mill.
Short-circuit protection Fuse 6 A gL/gG
Protection class II, Insulated
Ambient temperature -30 °C to +80 °C
Protection class IP65 conforming to IEC/EN 60529
Type of connection Screw connections
Conductor cross sections
Single-wire 0.5 - 1.5 mm2 or Stran-
ded wire with ferrule 0.5 - 1.5 mm2
Enclosure Thermoplastic,
glass bre-reinforced (UL94-V0)
Cable entry 1 x M20 x 1.5
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
SKI
The SKI is the slimline version of a safety switch with separate
actuator. It is based on the BERNSTEIN I88 family. Its dimensions,
not including the actuating head, correspond to EN 50047.
The actuating head is rotary mounted and has two actuator
openings. The SKI safety switch is predestined for installation on
section structures and in applications with confined installation
conditions. Compared to the SKT, it offers more connection space
for the wiring and variants with up to three switching contacts
are available.
Other advantages of this series include:
z Integrated eject function (FE):
The actuator is ejected if the door is not locked securely.
Consequently, the safety contact is opened, thus preventing
the machine from starting up. In addition, this function makes
it apparent that the door still needs to be locked.
z Actuating force (up to 50 N):
The standard actuating force is 10 N. Depending on the switch
variant, an actuating force of 50 N can also be selected. In many
applications, hatches and doors need to be secured to prevent
them being opened unintentionally. This is achieved by means
of bolts, fasteners or other latching mechanisms. The SKI safety
switch should be selected for applications requiring increased
actuating force.
z Universal radius actuator (MRU):
The MRU actuator is ideally suited for applications where the
installation conditions severely restrict the actuating travel or
radius. It has an adjustable actuating radius in the horizontal
and vertical plane.
Rmin in setting directions 50 mm
Actuating forces FE to FI50
1 Depending on switching system. See Table on Pages 76-79.
81
Technical data
Electrical data
Rated insulation voltage Ui max. 250 V AC
Rated operating voltage Ue max. 240 V
Conventional thermal current
Ithe 5 A
Utilization category AC-15, Ue /Ie 240 V / 1.5 A
Mechanical data
Switching frequency ≤ 30/min.
Mechanical service life 1 x 106 switching cycles
B10d
(
up to
) 1
2 Mill.
Short-circuit protection Fuse 6 A gL/gG
Protection class II, Insulated
Ambient temperature -30 °C ... +80 °C
Protection class IP65 conforming to IEC/EN 60529
Type of connection Screw connections
Conductor cross sections Single-wire 0.5 - 1.5 mm2 or
Stranded wire with ferrule 0.5 - 1.5 mm2
Enclosure
Thermoplastic, glass bre-reinforced (UL94-V0)
Cable entry 3 x M16 x 1.5
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
1 Depending on switching system. See Table on Pages 76-79.
Cap
Rmin 150 mm (5.9")
Actuator: Metal
Safety Switches with Separate Actuator
SKC
In terms of lengths, the SKC safety position switch is the 15 mm
shorter variant of the SK. This makes it the right choice for confined
installation conditions.
The SKC otherwise offers the same advantages as the SK:
Industrial standard with particular emphasis on safety, personal
protection, variable actuator head with two actuator openings.
Other decisive advantages include:
z Different actuating forces:
Corresponding to your specific application, in addition to
the standard 10 N, you can also choose an actuating force
of 5, 20, 30 or 50 N.
Actuating forces from 30 to 100 N can be realised with the
aid of additional components that are mounted on the out-
side of the switch.
z Anti-tamper facility:
The switching system is protected by multiple coding to ensure
enhanced safety of your application.
z Outstanding handling:
With the two slots you can easily adjust the SKC safety switch
and lock it in position by means of the two holes accessible
from the top or the two holes accessible from the front. The
switch can be wired from three different sides. A transparent
cover prevents foreign particles from entering the contact
space while connecting the power supply cable.
82
SK
Technical data
Electrical data
Rated insulation voltage
(
up to
) 1
Ui max. 400 V AC
Rated operating voltage Ue max. 240 V
Conventional thermal current (
up to
) 1
Ithe 10 A
Utilization category AC-15, Ue /Ie 240 V / 1.5 A
Mechanical data
Switching frequency ≤ 30/min
Mechanical service life 1 x 106 switching cycles
B10d
(bis zu) 1
2 Mill.
Short-circuit protection
(
up to
) 1
Fuse 10 A gL/gG
Protection class II, Insulated
Ambient temperature -30 °C ... +80 °C
Protection class IP65 conforming to IEC/EN 60529
Type of connection Screw connections
Conductor cross sections Single-wire 0.5 - 1.5 mm2 or
Stranded wire with ferrule 0.5 - 1.5 mm2
Enclosure
Thermoplastic, glass bre-reinforced (UL94-V0)
Cable entry 3 x M20 x 1.5
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
50 mm to direction
of adjustment
Actuator: metal
The SK safety position switch is an industry standard and can
be used in virtually any application.
Thanks to design safety features conforming to VDE 0660 T200,
IEC 60947-5-1 and the test regulations GS-ET 15, the SK is parti-
cularly suitable for personal protection applications. Its versatility
is enhanced by the variable actuator head and two actuator
openings.
Other decisive advantages include:
z Different actuating forces:
Corresponding to your specific application, in addition to
the standard 10 N, you can also choose an actuating force
of 5, 20 or 30 N.
Actuating forces from 30 to 100 N can be realised with the
aid of additional components that are mounted on the out-
side of the switch.
z Anti-tamper facility:
The switching system is protected by multiple coding to
ensure enhanced safety of your application.
z Outstanding handling:
With the two slots you can easily adjust the SK safety switch
and lock it in position by means of the two holes accessible from
the top or the two holes accessible from the front. The switch
can be wired from three different sides. A transparent cover
prevents foreign particles from entering the contact space while
connecting the power supply cable.
1 Depending on switching system. See Table on Pages 76-79.
83
1 NC contacts
Switching operation
2 NC contacts
1 NC / 1 NO contact
Overlapping
1 NC / 1 NO contact
Approvals
SKT SKI
Standard High actuating force
Radius actuation
Standard High actuating force
Radius actuation
6016869056
SKI-A2Z M3
6016869122
SKI-A2Z MRU
6016469066
SKT-A2Z M3
6016419059
SKT-U1Z M3
6016819052
SKI-U1Z M3
6016819139
SKI-U1Z FI50 M3
6016819123
SKI-U1Z MRU
6016869058
SKI-UV15Z M3
6016869145
SKI-UV15Z FI50 M3
6016869131
SKI-UV15Z MRU
U
Special features/variants
(on request)
zReplacement actuator for:
3112850340
Special features/variants
(on request)
zReplacement actuator for:
Standard 3112850340
High actuating force 3112850340
Radius actuation 3911452058
Safety Switches with Separate Actuator
84
6016169086
SK-UV15Z MRU
6016169085
SK-A2Z MRU
6016119084
SK-U1Z MRU
Radius actuation
6016169061
SK-UV15Z F30 M
6016169053
SK-A2Z F30 M
6116119109
SK-U1Z F30 M
High actuating force
Special features/variants
(on request)
z100 N actuating force on request
zReplacement actuator for:
Standard 3911452116
High actuating force 3911451914
Radius actuation 3911452058
U
6016169026
SK-UV15Z M
6016169036
SK-A2Z M
6016119016
SK-U1Z M
Standard
8
(0.31")
30
(1.18")
33.5
(1.32")
Ø5.1
(0.20")
7
(0.28")
90
(3.54")
52
(2.05")
5.5
(0.22")
40
(1.57")
8
(0.31")
29
(1.15")
18.1
(0.71")
40
(1.57")
52
(2.05")
27
(1.07")
7.9
(0.31")
M20x1.5
29
(1.14")
SK
6016169087
SKC-A1Z MRU
Radius actuation
6116169016
SKC-A1Z F30 M
High actuating force
Special features/variants
(on request)
z50 N and 100 N actuating force
on request
zReplacement actuator for:
Standard 3911452116
High actuating force 3911451914
Radius actuation 3911452058
U
6016169039
SKC-A1Z M
Standard
8
(0.32")
30
33
(1.30")
Ø5.1
(0.20")
7
(0.28")
75
(2.95")
52
(2.05")
5.5
(0.22")
40
(1.57")
8
(0.31")
18.1
(0.71")
29.1
(01.15")
40
(1.57")
52
(2.05")
7.9
(0.31")
27
(1.06")
M16x1.5
29
(1.14")
(01.18")
SKC
85
max. 0.5 Nm
1.
2. 3.
1.
Switch with VTW, VTU, VT actuator
Variable VTU head
These position switches of the tried-and-tested switch
families I88, ENK, ENM2 and GC correspond to Type 2.
This means that you can use Type 1 and Type 2 position
switches corresponding to your applications while using
one family of switches.
ENM-VTW ENK-VTU
This results in many advantages:
z Standardisation:
Switches of one family have the same mounting dimensions
and the same electrical properties.
z Reduced costs:
II88, ENK, ENM2 and GC are used in large quantities. This not
only reflects the quality of the products but also means lower
prices compared to special designs used in small quantities.
Repositioning the actuator head either in horizontal or
vertical direction results in 8 approach actuator directions.
One-way screw
Safety Switches with Separate Actuator
86
0
S
0
S
40
30
40
2
60
16
31
32-37
46
116.5
ø5.2
75
6.5
130.5
32
M20x1.5
29
15
9
20
8
ø4.5
83
37.1
Technical data I88 ENK ENM2 GC
Electrical data
Rated insulation voltage Ui250 V AC 400 V AC 400 V AC 400 V AC
Conventional thermal
current (up to) 1Ithe 10 A 10 A 10 A 10 A
Rated operating voltage Ue240 V 240 V 240 V 240 V
Utilization category
(up to) 1
AC-15, Ue /Ie 240 V / 3 A AC-15, Ue /Ie 240 V / 3 A AC-15, Ue/Ie 240 V / 3 A AC-15, Ue /Ie 240 V / 3 A
Forced disconnection pconforming to IEC/EN 60947-5-1,
Addendum K conforming to IEC/EN 60947-5-1,
Addendum K conforming to IEC/EN 60947-5-1,
Addendum K conforming to IEC/EN 60947-5-1,
Addendum K
Short-circuit protection
(up to) 1
Fuse 10 A gL/gG Fuse 10 A gL/gG Fuse 10 A gL/gG Fuse 10 A gL/gG
Protection class II, Insulated II, Insulated I I
Mechanical data
Enclosure Thermoplastic,
glass bre-reinforced (UL 94-V0)
Thermoplastic,
glass bre-reinforced Aluminium pressure die-casting Aluminium pressure die-casting
Cover Thermoplastic,
glass bre-reinforced
(UL 94-V0)
Thermoplastic,
glass bre-reinforced Sheet aluminium Sheet aluminium
Actuation Separate actuator,
Thermoplastic
Separate actuator, (St/PA),
Actuator (PA6 GV/Zn-GD) Separate actuator,(St / PA) Separate actuator
Ambient temperature -30°C to +80°C -30°C to +80°C -30°C to +80°C -30°C to +80°C
Mechanical service life 1 x 106 switching cycles 1 x 106 switching cycles 1 x 106 switching cycles 1 x 106 switching cycles
B10d 2 mill. 2 mill. 2 mill. 2 mill.
Switching frequency ≤ 50/min. max. 30/min. ≤ 50/min. ≤ 10/min.
Mounting 2 x M4 4 x M5 4 x M5 2 x M4
Type of connection Screw connections Screw connections Screw connections Screw connections
Conductor cross sections
Single-wire 0.5 - 1.5 mm2 or Stran-
ded wire with ferrule 0.5 - 1.5 mm2Single-wire 0.5 - 1.5 mm2 or Stran-
ded wire with ferrule 0.5 - 1.5 mm2Single-wire 0.5 - 1.5 mm2 or Stran-
ded wire with ferrule 0.5 - 1.5 mm2Single-wire 0.5 - 1.5 mm2 or Stran-
ded wire with ferrule 0.5 - 1.5 mm2
Cable entry 1 x M20 x 1.5 1 x M20 x 1.5 1 x M20 x 1.5 1 x M20 x 1.5
Weight ≈ 0.09 kg ≈ 0.23 kg ≈ 0.33 kg ≈ 0.32 kg
Installation position Any Any Any Any
Protection class
IP65
conforming to
EN 60529
IP65
conforming to
EN 60529
IP65 conforming to EN 60529 IP65 conforming to EN 60529
Standards
VDE 0660 T100, DIN EN 60947-1, IEC 60947-1
VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1
GC-VT
1 Depending on switching system. See Table on Pages 76-79. 87
I88 VTW ENK VTU
Standard High actuating force
Radius actuation
Standard High actuating force
Radius actuation
6016669133
ENK-A2Z VTU
6016819018
I88-U1Z VTW
6016619132
ENK-U1Z VTU
6016669154
ENK-UV15Z VTU
Replacement actuator: 3911702100
Special features/variants
(on request)
zAll actuators specied under „Safety
Switches with Separate Actuator and
Latching Device (SLK/SLM)“ can be
used for these switches
Replacement actuator: 3911702100
Special features/variants
(on request)
zAll actuators specied under „Safety
Switches with Separate Actuator and
Latching Device (SLK/SLM)“ can be
used for these switches
Switching operation
2 NC contacts
1 NC / 1 NO contact
Overlapping
1 NC / 1 NO contact
Approvals
Safety Switches with Separate Actuator
88
High actuating force
Replacement actuator: 3912001275
Special features/variants
(on request)
6116769064
GC-A2Z VT 90GR
6121100555
GC-U1Z VT 90GR
Standard
Sackloch für Passstift
Ø4 ; 5 ,5 tief
Blind hole for tted pin
Ø4 ; 5.5 deep
GC VT
Radius actuation
High actuating force
Replacement actuator: 3911702100
Special features/variants
(on request)
zAll actuators specied under „Safety
Switches with Separate Actuator and
Latching Device (SLK/SLM)“ can be
used for these switches
U
6016269104
ENM2-UV15Z VTW
6016269105
ENM2-A2Z VTW
6016219100
ENM2-U1Z VTW
Standard
ENM2 VTW
89
SLK
Safety Switches with Separate Actuator and Interlock
Machines that continue running after being
switched off are often part of automated
production processes. Safety guards pre-
vent operator access and must therefore
be kept closed until the hazards posed by
machine movement have ceased.
Safety position switches with interlock
function ensure that safety gates, safety
doors and other protective guards remain
closed for as long as a hazardous situation
exists.
In production processes safety position
switches have three main tasks:
z Enabling the machine/process when the
safety guard is closed and interlocked
z Disabling the machine/process when
the safety guard is opened
z Position monitoring of the safety guard
and interlock
The SLK/SLM safety position switches with
separate actuators and interlock enable the
user to realise locking systems conforming
to EN 1088, EN ISO 12100-1, 12100-2 and
since 29.12.2009 to the compulsory Machi-
nery Directive 2006/42/EC.
System description
SLK/SLM safety position switches with inter-
lock function are available in versions with
spring force locking action and magnetic
force locking action. The separate actuator
is connected form-fit with the safety guard.
It transfers the locking force to the safety
guard and monitors its position. Thanks to
its triple coding, the separate actuator ensures
a high degree of anti-tamper security. The
interlock facility in association with the SLK/
SLM safety position switches is integrated
in the switch enclosure. To lock the actuator
in connection with a switching mechanism,
the required interlock is achieved by means
of a spring mechanism in the spring-force
locked version and by an electromagnet in
the magnetic-force locked version.
Locking principle
Spring force (closed-circuit current)
The safety guard is locked automatically
when the actuator is inserted to its end
position. It is unlocked by energising the
electromagnet, allowing the safety guard
to be opened.
Magnetic force (working current)
The lock (interlock) is deactivated when
the electromagnet is de-energised, in the
event of fault in actuation or power failure.
The safety guard can be opened.
90
Product advantages
z Two independent safety circuits ensure
reliable integration
zWith two contacts, circuit
1 monitors the actuator
zWith two contacts, circuit
2 monitors the interlock
The contact configuration is
variable and may deviate from
the selection table if required.
z Two different operating voltages
for universal integration::
z24 V AC / DC
z110 V / 230 V AC
z Rotary actuating head (4x 90°) as well
as horizontal and vertical actuation
ensure complete flexibility in use
z Compact design with short overall size
of only 170 mm
z Innovative installation with
spring-loaded terminals
z Function conforming to GS ET 19,
EN 60 204-1, EN 60 947-1 and
EN 60 947-5-1
Safe operation
The stainless steel actuator ensures safe
and reliable operation. Its coding prevents
tampering and bypassing the system
„in an easier way“. The radius actuator is
ideal for monitoring smaller safety gates.
It can be preset horizontally or vertically
and is also made from stainless steel.
Innovative installation
The SLK is electrically connected safely
and reliably by means of terminals. Spring-
loaded terminals are used, into which the
wires with ferrules can be inserted with-
out the need for tools. The fact that the
connection compartment is separate from
the functional parts contributes to ensuring
secure and reliable connection. The connec-
tion compartment conforms to protection
class IP67.
Flexible in use
The SLK safety switch can be actuated
in horizontal and vertical direction. Prior
to installation it is preset by simply repo-
sitioning the head section.This flexibility
in installation is achieved by positioning
the actuator head in steps of 4 x 90°.
IMPORTANT: The actuator for the SLK must be ordered separately. You will find a corresponding overview on Pages 96-97.
The actuator is not included and must be ordered separately.
91
Product selection
Article number Designation Locking action Contacts Supply voltage Additional function
Actuator Interlock
6018119045 SLK-F-UC-55-R1-A0-L0-0 Spring 1NC / 1NO 1NC / 1NO 24 Volt AC / DC Auxiliary release
6018119066 SLK-F-UC-55-R1-A0-L1-0 Spring 1NC / 1NO 1NC / 1NO 24 Volt AC / DC Auxiliary release, LED
6018169054 SLK-F-UC-22-R1-A0-L0-0 Spring 2 NC 2 NC 24 Volt AC / DC Auxiliary release
6018169050 SLK-F-UC-25-R1-A0-L0-0 Spring 2 NC 1NC / 1NO 24 Volt AC / DC Auxiliary release
6018169068 SLK-F-UC-25-R1-A0-L1-0 Spring 2 NC 1NC / 1NO 24 Volt AC / DC Auxiliary release, LED
6018119061 SLK-F-UC-55-R2-A0-L0-0 Spring 1NC / 1NO 1NC / 1NO 24 Volt AC / DC Emergency release
6018169055 SLK-F-NC-22-R1-A0-L0-0 Spring 2 NC 2 NC 110 / 230 AC Auxiliary release
6018119046 SLK-F-NC-55-R1-A0-L0-0 Spring 1NC / 1NO 1NC / 1NO 110 / 230 AC Auxiliary release
6018119067 SLK-F-NC-55-R1-A0-L1-0 Spring 1NC / 1NO 1NC / 1NO 110 / 230 AC Auxiliary release, LED
6018169051 SLK-F-NC-25-R1-A0-L0-0 Spring 2 NC 1NC / 1NO 110 / 230 AC Auxiliary release
6018169069 SLK-F-NC-25-R1-A0-L1-0 Spring 2 NC 1NC / 1NO 110 / 230 AC Auxiliary release, LED
6018119047 SLK-M-UC-55-R0-A0-L0-0 Magnet 1NC / 1NO 1NC / 1NO 24 Volt AC / DC
6018169052 SLK-M-UC-25-R0-A0-L0-0 Magnet 2 NC 1NC / 1NO 24 Volt AC / DC
6018169056 SLK-M-UC-22-R0-A0-L0-0 Magnet 2 NC 2 NC 24 Volt AC / DC
6018119048 SLK-M-NC-55-R0-A0-L0-0 Magnet 1NC / 1NO 1NC / 1NO 110 / 230 AC
6018169053 SLK-M-NC-25-R0-A0-L0-0 Magnet 2 NC 1NC / 1NO 110 / 230 AC
6018169057 SLK-M-NC-22-R0-A0-L0-0 Magnet 2 NC 2 NC 110 / 230 AC
Technical data Spring
24 Volt AC / DC Spring
110 / 230 AC Magnet
24 Volt AC / DC Magnet
110 / 230 AC
Electrical data
Rated insulation voltage Ui250 V 250 V 250 V 250 V
Utilization category AC-15, Ue /Ie 230 V / 2.5 A AC-15, Ue /Ie 230 V / 2.5 A AC-15, Ue /Ie 230 V / 2.5 A AC-15, Ue /Ie 230 V / 2.5 A
Conventional thermal current
Ithe 5 A 5 A 5 A 5 A
Short-circuit protection 4 A gL 4 A gL 4 A gL 4 A gL
Protection class II, Insulated II, Insulated II, Insulated II, Insulated
Electromagnet
Duty factor 100 % ED (an E1; E2) 100 % ED (an E1; E2) 100 % ED (an E1; E2) 100 % ED (an E1; E2)
Thermal class F (155 °C) F (155 °C) F (155 °C) F (155 °C)
Switch-on power 12 VA (0.2 s) 65 VA (0.1 s) 12 VA (0.2 s) 12 VA (0.2 s)
Continuous power 4.4 VA 8 VA 4.4 VA 4.4 VA
Mechanical data
Enclosure Thermoplastic GV (UL94-V0) Thermoplastic GV (UL94-V0) Thermoplastic GV (UL94-V0) Thermoplastic GV (UL94-V0)
Cover Thermoplastic GV (UL94-V0) Thermoplastic GV (UL94-V0) Thermoplastic GV (UL94-V0) Thermoplastic GV (UL94-V0)
Actuator Thermoplastic GV / Zn-GD Thermoplastic GV / Zn-GD Thermoplastic GV / Zn-GD Thermoplastic GV / Zn-GD
Ambient temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °C
Switching function 2 NC contacts, 2 NO contacts 2 NC contacts, 2 NO contacts 4 NC contacts 2 NC contacts, 2 NO contacts
Switching principle 4 Slow-action contacts 4 Slow-action contacts 4 Slow-action contacts 4 Slow-action contacts
Mechanical service life 1 x 106 switching cycles
(max. 600 switching cycles / h)
1 x 106 switching cycles
(max. 600 switching cycles / h)
1 x 106 switching cycles
(max. 600 switching cycles / h)
1 x 106 switching cycles
(max. 600 switching cycles / h)
B10d 2 mill. 2 mill. 2 mill. 2 mill.
Minimum actuating radius Rmin See datasheet, actuator See datasheet, actuator See datasheet, actuator See datasheet, actuator
Approach speed Vmax 0.5 m/s0.5 m/s0.5 m/s0.5 m/s
Mounting 4 x M5 4 x M5 4 x M5 4 x M5
Cross sections 0.5 - 1.5 mm20.5 - 1.5 mm20.5 - 1.5 mm20.5 - 1.5 mm2
Type of connection Cage clamp terminal Cage clamp terminal Cage clamp terminal Cage clamp terminal
Cable entry 3 x M20 x 1.5 3 x M20 x 1.5 3 x M20 x 1.5 3 x M20 x 1.5
Weight ≈ 0.34 kg ≈ 0.30 kg ≈ 0.30 kg ≈ 0.35 kg
Protection class
IP67 conforming to IEC/EN 60529 IP67 conforming to IEC/EN 60529 IP67 conforming to IEC/EN 60529 IP67 conforming to IEC/EN 60529
Installation position Any Any Any Any
Locking principle Spring force Spring force Magnetic force Magnetic force
Latching force FZh ≤ 1500 N to GS-ET-19 ≤ 1500 N to GS-ET-19 ≤ 1500 N to GS-ET-19 ≤ 1500 N to GS-ET-19
SLK
Safety Switches with Separate Actuator and Interlock
92