RS-100 100W Single Output Switching Power Supply series Features : *Universal AC input / Full range *Protections: Short circuit / Overload / Over voltage *Cooling by free air convection *LED indicator for power on *100% full load burn-in test *All using 105 long life electrolytic capacitors *Withstand 300VAC surge input for 5 second *High operating temperature up to 70 *Withstand 5G vibration test *High efficiency, long life and high reliability *3 years warranty .. SPECIFICATION MODEL OUTPUT INPUT RS-100-3.3 RS-100-5 RS-100-12 RS-100-15 RS-100-24 RS-100-48 DC VOLTAGE 3.3V 5V 12V 15V 24V 48V RATED CURRENT 20A 16A 8.5A 7A 4.5A 2.3A CURRENT RANGE 0 ~ 20A 0 ~ 16A 0 ~ 8.5A 0 ~ 7A 0 ~ 4.5A 0 ~ 2.3A RATED POWER 66W 80W 102W 105W 108W 110.4W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 2.0% 11.4 ~ 13.2V 1.0% 14.25 ~ 16.5V 1.0% 22.8 ~ 26.4V 1.0% 45.6 ~ 52.8V 1.0% 3.2V ~ 3.5V VOLTAGE TOLERANCE Note.3 3.0% LINE REGULATION Note.4 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION Note.5 2.0% 1.0% 0.5% 0.5% 0.5% 0.5% 84% 84% SETUP, RISE TIME 500ms, 20ms/230VAC HOLD UP TIME (Typ.) 100ms/230VAC VOLTAGE RANGE 88 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 74% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.5A/115VAC 1.5A/230VAC COLD START 40A/230VAC LEAKAGE CURRENT 1200ms, 30ms/115VAC at full load 18ms/115VAC at full load 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 77% 81% 82% <2mA / 240VAC 110 ~ 150% rated output power OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 6) EMC EMISSION OTHERS 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH 0.03%/ (0 ~ 50) 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25J/ 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A 260.8Khrs min. MIL-HDBK-217F (25) 159*97*38mm (L*W*H) 0.6Kg; 24pcs/15.4Kg/0.7CUFT DIMENSION 55.2 ~ 64.8V Protection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to "Derating Curve") MTBF PACKING NOTE Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. File Name:RS-100-SPEC 2012-11-14 RS-100 100W Single Output Switching Power Supply Mechanical Specification Case No. 901C series Unit:mm 3.5 7 152.5 1 3 84.5 8.2 4 5 2-M 6 97 65 9.5 2 3 7 .5 3 4.5 78 24 159 150 Terminal Pin No. Assignment 22 Pin No. 1 2 3 38 M3 3.5 28.5 9 3.5 3- 18 18.5 9 6.5 Assignment AC/L AC/N FG Pin No. 4,5 6,7 Assignment DC OUTPUT -V DC OUTPUT +V 117 Block Diagram fosc : 60KHz RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING DETECTION CIRCUIT FG O.L.P. +V -V CONTROL O.V.P. Derating Curve Static Characteristics 100 100 Others 90 80 80 70 3.3V,5V LOAD (%) LOAD (%) 60 40 20 -25 -25 0 0 10 20 30 40 50 AMBIENT TEMPERATURE () 60 70 (HORIZONTAL) 60 50 40 88 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RS-100-SPEC 2012-11-14