LCA100L Single Pole OptoMOS(R) Relay Load Voltage Load Current Max RON LCA100L 350 120 25 Description LCA100 is a 350V, 120mA, 25 1-Form-A relay. It features the lowest on-resistance in an OptoMOS relay with 350V peak load voltage. Current limiting version is also available. ("L" suffix) Units V mA Features * Small 6 Pin DIP Package * Low Drive Power Requirements (TTL/CMOS Compatible) * No Moving Parts * High Reliability * Arc-Free With No Snubbing Circuits * 3750VRMS Input/Output Isolation * FCC Compatible * VDE Compatible * No EMI/RFI Generation * Machine Insertable, Wave Solderable * Current Limiting, Surface Mount and Tape & Reel Versions Available Approvals * UL Recognized: File Number E76270 * CSA Certified: File Number LR 43639-10 * BSI Certified to: * BS EN 60950:1992 (BS7002:1992) Certificate #: 7344 * BS EN 41003:1993 Certificate #: 7344 Ordering Information Applications * Telecommunications * Telecom Switching * Tip/Ring Circuits * Modem Switching (Laptop, Notebook, Pocket Size) * Hookswitch * Dial Pulsing * Ground Start * Ringer Injection * Instrumentation * Multiplexers * Data Acquisition * Electronic Switching * I/O Subsystems * Meters (Watt-Hour, Water, Gas) * Medical Equipment--Patient/Equipment Isolation * Security * Aerospace * Industrial Controls Part # LCA100L LCA100LS LCA100LSTR Description 6 Pin DIP (50/Tube) 6 Pin Surface Mount (50/Tube) 6 Pin Surface Mount (1000/Reel) Pin Configuration LCA100/LCA100L Pinout DC Only Configuration + Control - Control Do Not Use 1 6 2 5 3 4 + Load - Load Switching Characteristics of Normally Open (Form A) Devices 10ms CONTROL LOAD 10%+ DS-LCA100L-R1 www.clare.com +90% 10%+ TON TOFF 1 LCA100L Absolute Maximum Ratings (@ 25 C) Parameter Min Input Power Dissipation - - 1501 mW Input Control Current Peak (10ms) - - 50 1 mA A Reverse Input Voltage - - 5 V - - 8002 mW Total Power Dissipation Isolation Voltage Input to Output 3750 - - VRMS Operational Temperature -40 - +85 C Storage Temperature -40 - +125 C - - +260 +220 C C Soldering Temperature (10 Seconds Max.) DIP Package Surface Mount Package 1 Derate Linearly 1.33 mw/C 2 Derate Linearly 6.67 mw/C Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this data sheet is not implied. Exposure of the device to the absolute maximum ratings for an extended period may degrade the device and effect its reliability. Typ Max Units Electrical Characteristics PARAMETER CONDITIONS SYMBOL MIN TYP MAX UNITS Load Voltage (Peak) - VL - - 350 V Load Current (Continuous) AC/DC Configuration DC Configuration - IL IL - - 120 200 mA mA Output Characteristics @ 25C Peak Load Current 10ms ILPK - - - mA On-Resistance AC/DC Configuration DC Configuration IL=120mA IL=200mA RON RON - - 25 8 Off-State Leakage Current VL=35OV ILEAK - - 1 A Switching Speeds Turn-On Turn-Off IF=5mA, VL=10V IF=5mA, VL=10V TON TOFF - - 5 5 ms ms Output Capacitance 50V; f=1MHz COUT - 35 - pF ICL 130 170 210 mA Load Current Limiting Input Characteristics @ 25C Input Control Current IL=120mA IF 5 - 50 mA Input Dropout Current - IF 0.4 0.7 - mA Input Voltage Drop 2 IF=5mA VF 0.9 1.2 1.4 V Reverse Input Voltage - VR - - 5 V Reverse Input Current VR=5V IR - - 10 A Input to Output Capacitance - CI/O - 3 - pF Input to Output Isolation - VI/O 3750 - - VRMS www.clare.com Rev. 1 LCA100L PERFORMANCE DATA* Device Count (N) 25 20 15 10 5 35 35 30 30 25 20 15 10 5 0 1.19 1.21 1.23 10 369.8 374.6 379.4 384.1 388.9 393.7 398.4 On-Resistance () Blocking Voltage (V) LCA100L Typical Turn-On Time (N=50 Ambient Temperature = 25C) (Load Current = 120mADC; IF = 5mADC) LCA100L Typical IF for Switch Dropout (N=50 Ambient Temperature = 25C) (Load Current = 120mADC) 25 25 20 20 20 15 10 5 0 Device Count (N) 25 Device Count (N) Device Count (N) 15 13.93 14.05 14.17 14.29 14.41 14.54 14.66 LCA100L Typical IF for Switch Operation (N=50 Ambient Temperature = 25C) (Load Current = 120mADC) 15 10 5 0 0.85 0.90 0.95 1.00 1.05 1.10 0.85 Load Current (mA) 20 15 10 5 0.90 0.95 1.00 1.05 1.10 1.15 1.72 0 0.15 180 0.016 160 0.014 140 0.012 120 100 20mA 10mA 5mA 80 60 0.17 0.19 -20 0 20 40 60 80 100 385 375 -20 0 20 40 60 Temperature (C) 80 100 0 20 40 60 80 LCA100L Typical Turn-On vs. Temperature (Load Current = 120mADC) LCA100L Typical Turn-Off vs. Temperature (Load Current = 100mADC) 5mA 2.000 1.500 10mA 20mA 1.000 0 -40 -20 Temperature (C) 0.500 380 0.006 -40 -20 0 20 40 60 80 100 120 Temperature (C) Turn-Off (ms) Turn-On (ms) 390 0.008 Temperature (C) 2.500 395 2.61 0.010 120 3.000 400 2.46 0 LCA100L Typical Blocking Voltage vs. Temperature 405 2.32 0.002 -40 410 2.17 0.004 40 Turn-Off (ms) -40 2.02 LCA100L Typical Leakage vs. Temperature (Measured across Pins 4 & 6) 0 0.13 1.87 Turn-On (ms) 20 0.10 5 LCA100L Typical Load Current vs. Temperature 25 0.08 10 LED Current (mA) LCA100L Typical Turn-Off Time (N=50 Ambient Temperature = 25C) (Load Current = 120mADC; IF = 5mADC) 0.06 15 0 1.15 LED Current (mA) Device Count (N) 20 0 1.25 LED Forward Voltage Drop (V) Blocking Voltage (VRMS) 25 5 0 1.17 Leakage (A) Device Count (N) 30 LCA100L Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25C) Device Count (N) 35 LCA100L Typical On-Resistance Distribution (N=50 Ambient Temperature = 25C) (Load Current = 120mADC) LCA100L Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25C) IF = 5mADC 100 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 -40 -20 0 20 40 60 80 100 120 Temperature (C) The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. Rev. 1 www.clare.com 3 LCA100L PERFORMANCE DATA* LCA100L Typical Turn-On vs. LED Forward Current (Load Current = 120mADC) 0.30 2.5 0.25 1.4 50mA 30mA 20mA 10mA 5mA 1.2 2.0 1.5 1.0 1.0 0.5 0.8 0 -20 0 20 40 60 80 100 Turn-Off (ms) 3.0 1.6 -40 120 5 10 20 25 30 35 40 45 50 0 20 15 10 5.0 4.0 4.0 2.0 1.0 0 80 100 120 -40 LCA100L Typical Load Current vs. Load Voltage (Ambient Temperature = 25C) IF = 5mADC 150 Load Current (A) 100 50 0 -50 -100 -150 -3 -2 -1 0 1 Load Voltage (V) 2 3 -20 0 20 25 30 35 40 45 50 3.0 2.0 1.0 20 40 60 80 -40 100 120 -20 0 20 40 60 80 100 120 Temperature (C) Temperature (C) LCA100L Energy Rating Curve LCA120L Typical Current Limiting vs. Temperature IF = 2mADC 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 10s 100s 1ms 10ms 100ms 300.00 250.00 Current (mA) 60 Temperature (C) 15 0 0 40 10 LCA100L Typical IF for Switch Dropout vs. Temperature (Load Current = 120mADC) 5.0 3.0 5 20 5 LED Forward Current (mA) LED Current (mA) LED Current (mA) On-Resistance () 15 LCA100L Typical IF for Switch Operation vs. Temperature (Load Current = 120mADC) 25 0 0.10 LED Forward Current (mA) 30 -20 0.15 0 0 LCA100L Typical On-Resistance vs. Temperature (Load Current = 120mADC; IF = 5mADC) -40 0.20 0.05 Temperature (C) Load Current (mA) LCA100L Typical Turn-Off vs. LED Forward Current (Load Current = 120mADC) 1.8 Turn-On (ms) LED Forward Voltage Drop (V) LCA100L Typical LED Forward Voltage Drop vs. Temperature 200.00 150.00 100.00 50.00 0 1s Time 10s 100s -40 -20 0 20 40 60 80 100 Temperature (C) *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application department. 4 www.clare.com Rev. 1 LCA100L Mechanical Dimensions 8.382 .635 (.330 .025) 6 Pin DIP Through Hole (Standard) 2.540 .127 (.100 .005) 7.620 .254 (.300 .010) 7.239 TYP. (.285) 3.302 (.130) 6.350 .127 (.250 .005) 9.144 .508 (.360 .020) 7.620 .127 (.300 .005) 5.080 .127 (.200 .005) PC Board Pattern (Top View) 2.540 .127 2.540 .127 (.100 .005) (.100 .005) 9.525 .254 (.375 .010) 6.350 .127 (.250 .005) 3.302 (.130) 2.540 .127 (.100 .005) 6.350 .127 (.250 .005) 9.144 (.360) 8.382 .635 (.330 .025) 7.620 .254 (.300 .010) .635 TYP. (.025) 6-.800 DIA. (6-.031 DIA.) .457 .076 (.018 .003) 6 Pin DIP Surface Mount ("S" Suffix) 4.445 .127 (.175 .005) PC Board Pattern (Top View) 8.305 .127 (.327 .005) 1.905 .127 (.075 .005) .254 TYP. (.010) .457 .076 (.018 .003) 1.499 .127 (.059 .005) Tape and Reel Packaging for 6 Pin Surface Mount Package 330.2 DIA. (13.00) Top Cover Tape Thickness .102 MAX. (.004) 6.731 MAX. 1.753 .102 (.265) (.069 .004) .406 MAX. (.016) 2.007 .102 1.498 .102 3.987 .102 (.079 .004) (.059 .004) (.157 .004) 7.493 .102 (.295 .004) 1 6 12.090 (.476) 10.100 (.398) 4.877 (.192) Top Cover Tape Embossed Carrier 16.002 .305 (.630 .012) .050R TYP. 11.989 .102 (.472 .004) 10.100 .102 (.398 .004) 1.549 .102 (.061 .004) User Direction of Feed Embossment Dimensions mm (inches) Rev. 1 www.clare.com 5 For additional information please visit our website at: www.clare.com Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare's Standard Terms and Conditions of Sale, Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of Clare's product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice. Specification: DS-LCA100L-R1.0 (c)Copyright 2002, Clare, Inc. All rights reserved. Printed in USA. 6/25/02