www.clare.com
LCA100L
Rev. 1
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for an extended period may degrade the device and effect
its reliability.
Absolute Maximum Ratings (@ 25˚ C)
2
Parameter Min Typ Max Units
Input Power Dissipation - - 1501mW
Input Control Current - - 50 mA
Peak (10ms) - - 1 A
Reverse Input Voltage - - 5 V
Total Power Dissipation - - 8002mW
Isolation Voltage
Input to Output 3750 - - VRMS
Operational Temperature -40 - +85 °C
Storage Temperature -40 - +125 °C
Soldering Temperature
(10 Seconds Max.)
DIP Package - - +260 °C
Surface Mount Package - - +220 °C
1Derate Linearly 1.33 mw/˚C
2Derate Linearly 6.67 mw/˚C
Electrical Characteristics
PARAMETER CONDITIONS SYMBOL MIN TYP MAX UNITS
Output Characteristics @ 25°C
Load Voltage (Peak) - VL- - 350 V
Load Current (Continuous)
AC/DC Configuration - IL- - 120 mA
DC Configuration - IL- - 200 mA
Peak Load Current 10ms ILPK --- mA
On-Resistance
AC/DC Configuration IL=120mA RON --25Ω
DC Configuration IL=200mA RON --8 Ω
Off-State Leakage Current VL=35OV ILEAK --1 µA
Switching Speeds
Turn-On IF=5mA, VL=10V TON --5 ms
Turn-Off IF=5mA, VL=10V TOFF --5 ms
Output Capacitance 50V; f=1MHz COUT -35- pF
Load Current Limiting ICL 130 170 210 mA
Input Characteristics @ 25°C
Input Control Current IL=120mA IF5-50mA
Input Dropout Current - IF0.4 0.7 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Voltage - VR--5 V
Reverse Input Current VR=5V IR- - 10 µA
Input to Output Capacitance - CI/O -3- pF
Input to Output Isolation - VI/O 3750 - - VRMS