Emergency stop KNA3
-
RS Part number 85100434
"Emergency stop" and "mobile guard monitoring" functions
Control device with one or two channels
3 "N/O" safety contacts with linked contacts-6A / 250 AC
1 "N/C" signalling contact
Level 4 according to NF.EN 954-1
Integrity check on control devices
Separate return loop
Four input circuits
Type
Function
Level of safety
Safety contacts
Supply voltage
Connections
Weight (g)
85
100
036
KNA3
-
XS
Emergency stopMobile guard monitoring
3
3
24 V ACDC
Screw terminals
310
85
100
037
KNA3
-
XS
Emergency stopMobile guard monitoring
3
3
40 - 260 V AC
Screw terminals
310
85
101
036
KNAC3
-
XS
Emergency stopMobile guard monitoring
4
3
24 V ACDC
Spring terminals
310
85
101
037
KNAC3
-
XS
Emergency stopMobile guard monitoring
4
3
40 - 260 V AC
Spring terminals
310
85
100
436
KNA3
-
RS
Emergency stopMobile guard monitoring
4
3
24 V ACDC
Screw terminals
310
85
100
434
KNA3
-
RS
Emergency stopMobile guard monitoring
4
3
115 V AC
Screw terminals
410
85
100
435
KNA3
-
RS
Emergency stopMobile guard monitoring
4
3
230 V AC
Screw terminals
410
85
100
536
KZP3
-
RS
Emergency stopMobile guard monitoring
4
3
24 V ACDC
Screw terminals
410
Supply voltage
On/off indication
1 power supply voltage LED
Type
Breaking capacity (V resistive)
1500 VA
Max. breaking current
6,82 A
Max. breaking voltage
440 V AC
Electrical endurance
105 operations at 1500 VA resistive
5x105 operations at 500 VA resistive
Mechanical life (operations)
107
On/off indication
Operating temperature (°C) IEC 68
-2-14
0→+50
Storage temperature (IEC 68
-2-12) (º
C)
-
20→+70
Internal voltage
24 V DC
fast transients
Drop
-out / short breaks / microbreaks
Un
-30% for 10 ms every 1 s
Un
-60% for 100 ms every 1 s according to IEC 61496-1/97
Un
-100% for 10 ms every 100 ms
Un
-50% for 20 ms every 200 ms
Un
-50% for 500 ms every 5 s
Material
Polycarbonate
Self-extinguishing-UL94 class VO
Protection Housing
IP 40
Degree of terminal protection
IP 20
Connection capacity
2 x 1,5 mm
2 multicore with ferrule
2 x 2,5 mm
2 solid conductor
Spring terminals, 2 terminals per connection point
-
rigid
wire
2,5 mm
2
Spring terminals, 2 terminals per connection point
-
flexible wire
1,5 mm
2
Operating range
Reset time
Maximum response time on emergency stop
< 50 ms
Number of safety circuits
Number of data circuits
1 "NC" AgSnO contacts
Max. absorbed power
Dielectric strength
2,95 kVaccording to CEI 664
-1
Resistance to tracking
Material group III
Radiated electromagnetic field
Electrostatic discharge
8 kV in the air acc. to IEC 1000.4.2
KNA3
-
RS / KZP3
-
RS: 15 kV in the air acc. to IEC 1000.4.2
Shock waves
KNA3
-
XS:
-
Common mode 1 kV acc. to IEC 1000.4.5 KNA3
-
RS / KZP3
-
RS:
-
Level 3 acc. to IEC 1000.4.5
-
Common mode 2kV for 24 V
and 24 V
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
21/03/2012 www.crouzet.com
-
Common mode 4 kV for 230 V
(2 kV residual current mode for KNA3-
RS)
Radio frequencies in common mode
KNA3
-
XS:
-
10 V rms Level 3 according to IEC 1000.4.6
-
150 KhZ TO 80 MHz (ENV 50141) according to IEC 1000.4.11
KNA3
-
RS / KZP3
-
RS:
-
30 Vrms Level X acc. to IEC 1000.4.6
150 kHz to 80 MHz (ENV 50141) according to IEC 1000.4.11
European "Machinery" Directive 89/392/EEC
French decree 92/765-766-768
European "Usage" Directive 89/655/EEC
French decree 93-40 /93-41
IEC 61496
-1
IEC 664
-1
En 50081
-2
EN 50082
-2
EN 60204
-1
EN 292
-1 and 2
Safety category to EN 954-1
Catégorie 4
EN 418
EN 1088
UL 508
UL
C22
-
2N
o
14 M91
(c) UL
GS
-
ET
-20
BG
Dimension Diagram : KNA3
-
RS / KZP3
-
RS
Dimension Diagram : Mounting
-
Removing
:
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
21/03/2012 www.crouzet.com
The KZP3
-RS is used to obtain and maintain a category 4 level of safety for an installation with two control devices.
Depending on the degree of safety required, KNA3-
XS / KNA3
-
RS / KZP3
-RS can receive the following components as inputs:
- pushbutton for start or validation (Y1-Y2)
- emergency stop pushbuttons with one or two contacts (A1-A2)
one or two contacts (A1-A2)
two contacts KNA3-
RS: Y11
-Y12 and Y21-Y22,
two contacts KZP3-
RS: Y11
-Y12 / Y21-Y22 and Y31-Y32 / Y41-Y42
- position sensors (limit switches) with
one or two contacts (A1-A2)
two contacts KNA3-
RS: Y11
-Y12 and Y21-Y22,
two contacts KZP3-
RS: Y11
-Y12 / Y21-Y22 and Y31-Y32 / Y41-Y42
A positive break operation device must be used if a single channel is used.
To increase the degree of safety, one "N/C" auxiliary contact per power contactor is wired in series with the start (or validation) pushbutton, to ensure self-checking in this part of the installation.
The KNA3
-XS has three "N/O" safety contacts (13-14/23-24/33-
34) and one "N/C" signalling contact (41
-42). One or more control devices may be wired up to the breaking capacity of the safety
contacts: 1500 VA. However, to limit internal heating, it is advisable not to exceed 10 A thermal for all three contacts. The signalling contact can be wired on a PLC input or integrated into a fault
signalling system.
The number of contacts can be extended and the breaking capacity thus increased. To do this, use the KZE3-
XS.
: KNA3
-
RS
Lég.
Legend
A1-A2
Power supply
Y11-Y12 / Y21-Y22
Redundant inputs with differentiated voltage for control devices
Y1-Y2
Start/validation
S1
-
S2
Short-circuit protection on start / validation input
X1
-
X2
Return loop
13-14/23-24/33-34
"N/O" safety contacts
41-42
"N/C" signalling contacts
Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected