© by SEMIKRON 030217 B 1 – 91
I:\Marketin\FRAMEDAT\datbl\B01-Semipack\SKET330-400.fm
1) See the assembly instructions
2) The screws must be lubricated
VRSM VRRM (dv/dt)cr ITRMS (maximum values for continuous operation)
VDRM 600 A 700 A
ITAV (sin. 180; Tcase = . . .)
VVV/µs 380 (68 °C) 440 A (78 °C)
900
1300
1500
1700
1900
2100
2300
800
1200
1400
1600
1800
2000
2200
500
1000
1000
1000
1000
1000
1000
SKET 330/08 D
SKET 330/12 E
SKET 330/14 E
SKET 330/16 E
SKET 330/18 E
SKET 330/20 E
SKET 330/22 E
SKET 400/08 D
SKET 400/12 E
SKET 400/14 E
SKET 400/16 E
SKET 400/18 E
Symbol Conditions SKET 330 SKET 400 Units
ITAV
ID
IRMS
sin. 180; (Tcase = . . .)
B2/B6 Tamb = 35 °C; P 16/300 F
W1/W3 Tamb = 35 °C; P 16/400 F
330
(78)
530 / 665
685 / 3 x 550
400
(84)
700 / 880
905 / 3 x 720
A
°C
A
A
ITSM
i2t
Tvj = 25 °C; 10 ms
Tvj = 130 °C; 10 ms
Tvj = 25 °C; 8,3 ... 10 ms
Tvj = 130 °C; 8,3 ... 10 ms
9 000
8 000
405 000
320 000
14 000
12 000
980 000
720 000
A
A
A2s
A2s
tgd
tgr
Tvj = 25 °C IG = 1 A
diG/dt = 1 A/µs
VD = 0,67 . VDRM
1
2
µs
µs
(di/dt)cr
tq
IH
IL
Tvj = 130 °C
Tvj = 130 °C
Tvj = 25 °C
Tvj = 25 °C; RG = 33 ; typ./max.
125
typ. 150 . . . 200
150 / 500
0,5 / 2
A/µs
µs
mA
A
VT
VT(TO)
rT
IDD; IRD
Tvj = 25 °C; (IT = . . .); max.
Tvj = 130 °C
Tvj = 130 °C
Tvj = 130 °C; V = VDRM / VRRM
2,05
(1500)
1,2
0,55
120
1,7
(2400)
0,92
0,3
80
V
A
V
m
mA
VGT
IGT
VGD
IGD
Tvj = 25 °C; d.c.
Tvj = 25 °C; d.c.
Tvj = 130 °C; d.c.
Tvj = 130 °C; d.c.
3
200
0,25
10
V
mA
V
mA
Rthjc
Rthch
Tvj; Tstg
cont.
sin. 180
rec. 120
0,09
0,095
0,11
0,02
– 40 ... + 130
°C/W
°C/W
°C/W
°C/W
°C
Visol
M1
M2
a
w
a. c. 50 Hz; r.m.s; 1 s/1 min
to heatsink
to terminals
approx.
3600 / 3000
5 (44 lb. in.) ± 15 %1)
17 (150 lb. in.) ± 15 %2)
5 . 9,81
940
V~
Nm
Nm
m/s2
g
Case page B 1 – 94 A 36
SEMIPACK® 4
Thyristor Modules
SKET 330
SKET 400
Features
Heat transfer through aluminium
nitride ceramic isolated metal
baseplate
Precious metal pressure
contacts for high reliability
With amplifying gate
UL recognized, file no. E 63 532
Typical Applications
DC motor control (e. g. for
machine tools)
Temperature control (e. g. for
ovens, chemical processes)
Professional light dimming
(studios, theaters)
SKET
SI (US) units
© by SEMIKRONB 1 – 92
Fig. 1 a Power dissipation vs. on-state current and ambient temperature
Fi
g
. 5 Recovered cha r
g
e vs. current decrease Fi
g
. 6 Transient thermal impendance vs. time
Fig. 1 b Power dissipation vs. on-state current and ambient temperature
0898
© by SEMIKRON B 1 – 930597
© by SEMIKRONB 1 – 94 0597