LOGO! Logic Modules General data Overview Application The LOGO! logic module is the user-friendly, low-cost solution for simple control tasks. LOGO! is universally applicable, e.g.: * Building installation and wiring (lighting, shutters, awnings, doors, access control, barriers, ventilation systems ...) * Control cabinet installation * Machine and device construction (pumps, small presses, compressors, hydraulic lifts, conveyors ...) * Special controls for conservatories and greenhouses * Signal preprocessing for other controllers The LOGO! Modular logic modules can be expanded easily for each application. Marine approvals * The compact, user-friendly, and low-cost solution for simple control tasks * Compact, user-friendly, can be used universally without accessories. * "All in one": the display and operator panel are integrated * 34 different functions can be linked at a press of a button or with PC software; up to 130 times in total * Functions can be changed simply using buttons; no complicated rewiring American Bureau of Shipping, Bureau Veritas, Det Norske Veritas, Germanischer Lloyd, Lloyds Register of Shipping; Polski Rejestr Statkow Catalog ST 70: Information on LOGO! can also be found in the catalog ST 70: 7 http://www.siemens.com/automation/ simatic/ftp/st70/html_00/st70k1ad.pdf Siemens LV 1 * 2006 7/17 LOGO! Logic Modules LOGO! Modular basic variants Overview * The space-saving basic variants * With interface for connection of expansion modules Selection and ordering data Version DT Order No. Price per PU PU PS* (UNIT, SET, M) PG Weight per PU approx. LOGO! Logic modules 24 Supply voltage 24 V DC, 8 digital inputs 24 V DC, of which 2 can be used as analog inputs (0 to 10 V), 4 digital outputs 24 V DC, 0.3 A; 130 function blocks can be combined, modular expandability A 6ED1 052-1CC00-0BA5 1 1 unit 200 0.191 LOGO! 12/24RC logic modules Supply voltage 12/24 V DC, 8 digital inputs 12/ 24 V DC, of which 2 can be used as analog inputs (0 to 10 V), 4 relay outputs 10 A, Integrated time switch; 130 function blocks can be combined, modular expandability A 6ED1 052-1MD00-0BA5 1 1 unit 200 0.228 LOGO! 24RC logic modules Supply voltage 24 V AC/DC, 8 digital inputs 24 V AC/DC, 4 relay outputs 10 A, Integrated time switch; 130 function blocks can be combined, modular expandability A 6ED1 052-1HB00-0BA5 1 1 unit 200 0.231 LOGO! 230RC logic modules Supply voltage 115/230 V AC/DC, 8 digital inputs 115/230 V AC/DC, 4 relay outputs 10 A, Integrated time switch; 130 function blocks can be combined, modular expandability A 6ED1 052-1FB00-0BA5 1 1 unit 200 0.232 7 kg * You can order this quantity or a multiple thereof. 7/18 Siemens LV 1 * 2006 LOGO! Logic Modules LOGO! Modular basic variants Accessories Version DT Order No. Price per PU PU PS* (UNIT, SET, M) PG Weight per PU approx. kg LOGO! manuals * German * English * French * Spanish * Italian 6ED1 050-1AA00-0AE6 6ED1 050-1AA00-0BE6 6ED1 050-1AA00-0CE6 6ED1 050-1AA00-0DE6 6ED1 050-1AA00-0EE6 1 1 1 1 1 1 unit 1 unit 1 unit 1 unit 1 unit 200 200 200 200 200 0.450 0.401 0.400 0.406 0.402 LOGO! Memory Cards for copying, with know-how protection A 6ED1 056-5CA00-0BA0 1 1 unit 200 0.004 LOGO! Soft Comfort V5.0 for programming on the PC in LAD/FBD; executes under Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM A 6ED1 058-0BA01-0YA0 1 1 unit 200 0.101 LOGO! Soft Comfort Upgrade from V1.0 to V5.0 A 6ED1 058-0CA01-0YE0 1 1 unit 200 0.098 LOGO! PC cables for transferring programs between LOGO! and PC A 6ED1 057-1AA00-0BA0 1 1 unit 200 0.159 LOGO! News Box, 12/24 V contains LOGO! 12/24RC, LOGO! PC cable, LOGO! Soft Comfort, Tips&Tricks manual, screw driver, information material * German * English A A 6ED1 057-3BA00-0AA4 6ED1 057-3BA00-0BA4 1 1 1 unit 1 unit 2Z0 2Z0 2.200 2.200 LOGO! News Box, 230 V contains LOGO! 230RC, LOGO! PC cable, LOGO! Soft Comfort, Tips&Tricks manual, screw driver, information material * German * English A A 6ED1 057-3AA01-0AA0 6ED1 057-3AA01-0BA0 1 1 1 unit 1 unit 2Z0 2Z0 2.200 2.340 7 A A B B B * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/19 LOGO! Logic Modules LOGO! Modular Pure variants Overview * The cost-optimized basic variants * With integrated interface for connection of expansion modules Selection and ordering data Version DT Order No. Price per PU PU PS* (UNIT, SET, M) PG Weight per PU approx. LOGO! Logic modules 24o Supply voltage 24 V DC, 8 digital inputs 24 V DC, of which 2 can be used as analog inputs (0 to 10 V), 4 digital outputs 24 V DC, 0.3 A; without display and keyboard; 130 function blocks can be combined, modular expandability A 6ED1 052-2CC00-0BA5 1 1 unit 200 0.175 LOGO! 12/24RCo logic modules Supply voltage 12/24 V DC, 8 digital inputs 12/ 24 V DC, of which 2 can be used as analog inputs (0 to 10 V), 4 relay outputs 10 A, Integrated time switch; without display and keyboard; 130 function blocks can be combined, modular expandability A 6ED1 052-2MD00-0BA5 1 1 unit 200 0.213 LOGO! 24RCo logic modules Supply voltage 24 V AC/DC, 8 digital inputs 24 V AC/DC, 4 relay outputs 10 A, Integrated time switch; without display and keyboard; 130 function blocks can be combined, modular expandability A 6ED1 052-2HB00-0BA5 1 1 unit 200 0.220 LOGO! 230RCo logic modules Supply voltage 115/230 V AC/DC, 8 digital inputs 115/230 V AC/DC, 4 relay outputs 10 A, Integrated time switch; without display and keyboard; 130 function blocks can be combined, modular expandability A 6ED1 052-2FB00-0BA5 1 1 unit 200 0.217 7 kg * You can order this quantity or a multiple thereof. 7/20 Siemens LV 1 * 2006 LOGO! Logic Modules LOGO! Modular Pure variants Accessories Version DT Order No. Price per PU PU PS* (UNIT, SET, M) PG Weight per PU approx. kg LOGO! manuals * German * English * French * Spanish * Italian 6ED1 050-1AA00-0AE6 6ED1 050-1AA00-0BE6 6ED1 050-1AA00-0CE6 6ED1 050-1AA00-0DE6 6ED1 050-1AA00-0EE6 1 1 1 1 1 1 unit 1 unit 1 unit 1 unit 1 unit 200 200 200 200 200 0.450 0.401 0.400 0.406 0.402 LOGO! Memory Cards for copying, with know-how protection A 6ED1 056-5CA00-0BA0 1 1 unit 200 0.004 LOGO! Soft Comfort V5.0 for programming on the PC in LAD/FBD; executes under Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM A 6ED1 058-0BA01-0YA0 1 1 unit 200 0.101 LOGO! Soft Comfort Upgrade from V1.0 to V5.0 A 6ED1 058-0CA01-0YE0 1 1 unit 200 0.098 LOGO! PC cables for transferring programs between LOGO! and PC A 6ED1 057-1AA00-0BA0 1 1 unit 200 0.159 LOGO! News Box, 12/24 V contains LOGO! 12/24RC, LOGO! PC cable, LOGO! Soft Comfort, Tips&Tricks manual, screw driver, information material * German * English A A 6ED1 057-3BA00-0AA4 6ED1 057-3BA00-0BA4 1 1 1 unit 1 unit 2Z0 2Z0 2.200 2.200 LOGO! News Box, 230 V contains LOGO! 230RC, LOGO! PC cable, LOGO! Soft Comfort, Tips&Tricks manual, screw driver, information material * German * English A A 6ED1 057-3AA01-0AA0 6ED1 057-3AA01-0BA0 1 1 1 unit 1 unit 2Z0 2Z0 2.200 2.340 7 A A B B B * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/21 LOGO! Logic Modules LOGO! Modular extension modules Overview * Expansion modules for connection to LOGO! Modular * With digital inputs and outputs, analog inputs or analog outputs Selection and ordering data Version DT Order No. Price per PU PU PS* (UNIT, SET, M) PG Weight per PU approx. LOGO! DM8 24 Supply voltage 24 V DC, 4 digital inputs 24 V DC, 4 digital outputs 24 V DC, 0.3 A A 6ED1 055-1CB00-0BA0 1 1 unit 200 0.122 LOGO! DM16 24 Supply voltage 24 V DC, 8 digital inputs 24 V DC, 8 digital outputs 24 V DC, 0.3 A A 6ED1 055-1CB10-0BA0 1 1 unit 200 0.122 LOGO! DM8 12/24R Supply voltage 12/24 V DC, 4 digital inputs 12/24 V DC, 4 relay outputs 5 A A 6ED1 055-1MB00-0BA1 1 1 unit 200 0.157 LOGO! DM8 24R Supply voltage 24 V AC/DC, 4 digital inputs 24 V AC/DC, 4 relay outputs 5 A A 6ED1 055-1HB00-0BA0 1 1 unit 200 0.158 LOGO! DM16 24R Supply voltage 24 V DC, 8 digital inputs 24 V DC, 8 relay outputs 5 A A 6ED1 055-1NB10-0BA0 1 1 unit 200 0.159 LOGO! DM8 230R Supply voltage 115/230 V AC/DC, 4 digital inputs 115/230 V AC/DC, 4 relay outputs 5 A A 6ED1 055-1FB00-0BA1 1 1 unit 200 0.159 LOGO! DM16 230R Supply voltage 115/230 V AC/DC, 8 digital inputs 115/230 V AC/DC, 8 relay outputs 5 A A 6ED1 055-1FB10-0BA0 1 1 unit 200 0.159 LOGO! AM2 Supply voltage 12/24 V DC, 2 analog inputs 0 to 10 V or 0 to 20 mA, 10 bit resolution A 6ED1 055-1MA00-0BA0 1 1 unit 200 0.119 LOGO! AM2 PT 100 Supply voltage 12/24 V DC, 2 analog inputs for Pt100, temperature range -50 C to 200 C A 6ED1 055-1MD00-0BA0 1 1 unit 200 0.120 LOGO! AM2 AQ Supply voltage 24 V DC, 2 analog outputs 0 to 10 V A 6ED1 055-1MM00-0BA0 1 1 unit 200 0.120 7 kg * You can order this quantity or a multiple thereof. 7/22 Siemens LV 1 * 2006 LOGO! Logic Modules LOGO! Modular extension modules Accessories Version DT Order No. Price per PU PU PS* (UNIT, SET, M) PG Weight per PU approx. kg LOGO! manuals * German * English * French * Spanish * Italian 6ED1 050-1AA00-0AE6 6ED1 050-1AA00-0BE6 6ED1 050-1AA00-0CE6 6ED1 050-1AA00-0DE6 6ED1 050-1AA00-0EE6 1 1 1 1 1 1 unit 1 unit 1 unit 1 unit 1 unit 200 200 200 200 200 0.450 0.401 0.400 0.406 0.402 LOGO! Memory Cards for copying, with know-how protection A 6ED1 056-5CA00-0BA0 1 1 unit 200 0.004 LOGO! Soft Comfort V5.0 for programming on the PC in LAD/FBD; executes under Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM A 6ED1 058-0BA01-0YA0 1 1 unit 200 0.101 LOGO! Soft Comfort Upgrade from V1.0 to V5.0 A 6ED1 058-0CA01-0YE0 1 1 unit 200 0.098 LOGO! PC cables for transferring programs between LOGO! and PC A 6ED1 057-1AA00-0BA0 1 1 unit 200 0.159 LOGO! News Box, 12/24 V contains LOGO! 12/24RC, LOGO! PC cable, LOGO! Soft Comfort, Tips&Tricks manual, screw driver, information material * German * English A A 6ED1 057-3BA00-0AA4 6ED1 057-3BA00-0BA4 1 1 1 unit 1 unit 2Z0 2Z0 2.200 2.200 LOGO! News Box, 230 V contains LOGO! 230RC, LOGO! PC cable, LOGO! Soft Comfort, Tips&Tricks manual, screw driver, information material * German * English A A 6ED1 057-3AA01-0AA0 6ED1 057-3AA01-0BA0 1 1 1 unit 1 unit 2Z0 2Z0 2.200 2.340 7 A A B B B * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/23 LOGO! Logic Modules LOGO! CM EIB/KNX communications modules Overview * Expansion module for the LOGO! basic variants * For communication between the LOGO! master and external EIB components via EIB. Application The CM EIB/KNX communication module allows communication between the LOGO! master and external EIB components via EIB. The module can be used to integrate LOGO! into an EIB system. Selection and ordering data Version DT Order No. LOGO! CM EIB KNX communications modules for connection to EIB, supply voltage 24 V DC B 6BK1 700-0BA00-0AA1 DT Order No. Price per PU PU PS* (UNIT, SET, M) PG Weight per PU approx. kg 1 1 unit 475 0.107 Accessories Version Price per PU PU PS* (UNIT, SET, M) PG Weight per PU approx. 7 kg LOGO! manuals * German * English * French * Spanish * Italian A A B B B 6ED1 050-1AA00-0AE6 6ED1 050-1AA00-0BE6 6ED1 050-1AA00-0CE6 6ED1 050-1AA00-0DE6 6ED1 050-1AA00-0EE6 1 1 1 1 1 1 unit 1 unit 1 unit 1 unit 1 unit 200 200 200 200 200 0.450 0.401 0.400 0.406 0.402 * You can order this quantity or a multiple thereof. 7/24 Siemens LV 1 * 2006 LOGO! Logic Modules AS-Interface connections for LOGO! Overview Every LOGO! can now be connected to the AS-Interface system Using the AS-Interface connection for LOGO!, an intelligent slave can be integrated in the AS-Interface system. With the modular interface it becomes possible to integrate the different basic devices in the system according to their functionality. Similarly, functionalities can be quickly and easily adapted to new requirements by exchanging the basic device. The interface module provides four inputs and four outputs on the system. These I/Os do not actually exist in hardware terms, however, but are only virtually present through the interface on the bus. Selection and ordering data Version DT Order No. AS-Interface connections for LOGO! A 3RK1 400-0CE10-0AA2 Price per PU PU PS* (UNIT, SET, M) PG Weight per PU approx. kg 1 unit 121 0.107 7 1 * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/25 LOGO! Logic Modules LOGO! Contact Overview * Switching module for switching resistive loads and motors directly Application LOGO! Contact is a switching module for direct switching of resistive loads up (up to 20 A) and motors (up to 4 kW). LOGO! Contact operates hum-free without noise pollution. LOGO! Contact is universally applicable: * Buildings/electrical installations * Industry and commerce Selection and ordering data Version DT Order No. Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg A A 6ED1 057-4CA00-0AA0 6ED1 057-4EA00-0AA0 1 1 1 unit 1 unit 200 200 0.160 0.160 7 LOGO! Contact Switching module for direct switching of resistive loads up to 20 A and motors up to 4 kW * Operating voltage 24 V * Operating voltage 230 V * You can order this quantity or a multiple thereof. 7/26 Siemens LV 1 * 2006 LOGO! Logic Modules LOGO! Software Overview * The user-friendly software for switchgear program generation on the PC * Switchgear program generation for function diagrams (FBD) or contact diagrams (LAD) * Additional testing, simulation, online testing and archiving of the switchgear programs * Professional documentation with the help of various comment and print functions Application LOGO! Soft Comfort is the multilingual software for switchgear program generation with LOGO! on the PC. LOGO! Soft Comfort can be used to program all components of the LOGO! family. Selection and ordering data Version DT Order No. Price per PU PU PS* (UNIT, SET, M) LG Weight per PU approx. LOGO! Soft Comfort V5.0 for programming on the PC in LAD/FBD; runs on Windows 98 SE and higher, Linux, MAC OSX; on CD-ROM A 6ED1 058-0BA01-0YA0 1 1 unit 200 0.101 LOGO! Soft Comfort Upgrade from V1.0 to V5.0 A 6ED1 058-0CA01-0YE0 1 1 unit 200 0.098 7 kg * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/27 3RP, 7PV Timing Relays 3RP15 timing relays in industrial enclosure, 22.5 mm Overview Application Standards The timing relays comply with: * EN 60721-3-3 "Environmental conditions" * EN 61812-1/DIN VDE 0435 Part 2021 "Solid-state relays, timing relays" * EN 61000-6-2 and EN 61000-6-4 "Electromagnetic compatibility" * EN 60947-5-1; (VDE 0660 Part 200) "Low-voltage controlgear, switchgear and systems - Electromechanical controlgear" 3RP15 timing relays, width 22.5 mm LED for indicating "Time relay on voltage" Operating time adjustment LED for indicating "Relay switched" Inspection window for set time range Time setting range selector switch Function switch Decive labeling plate Inspection window for set function NSB0_01423 Accessories Push-in lugs for screw mounting Sealable cap 7 Label set for marking the multifunction relay 7/28 Siemens LV 1 * 2006 Timing relays are used in control, starting, and protective circuits for all switching operations involving time delays. They guarantee a high level of functionality and a high repeat accuracy of timer settings. Enclosure design All timing relays are suitable for snap-on mounting onto 35 mm standard mounting rails according to EN 50022 or for screw fixing. 3RP, 7PV Timing Relays 3RP15 timing relays in industrial enclosure, 22.5 mm Selection and ordering data Solid-state timing relays for general use in control systems and mechanical engineering with: * 1 changeover contact or 2 changeover contacts Version * Single or selectable time setting ranges * Switching position indication by LED * Voltage indication by LED Time setting Rated control supply voltage DT Screw-type connection range t Us adjustable by rotary switch to AC 50/60 Hz DC V V Order No. PU (UNIT, SET, M) PS* PG Weight per PU approx. Price per PU kg 3RP15 05 timing relays, multifunction, 15 time setting ranges The functions can be adjusted by means of rotary switches. Indicator labels can be used to adjust different functions of the 3RP15 05 timing relay clearly and unmistakably. The corresponding labels can be ordered as an accessory. The same potential must be applied to terminals A. and B.1) with LED and 1 CO contact, 8 functions 3RP15 05-1B... 0.05 ... 1 s 0.15 ... 3 s 0.5 ... 10 s 1.5 ... 30 s 2 CO contacts, 0.05 ... 1 min 5 ... 100 s 16 functions 0.15 ... 3 min 0.5 ... 10 min 1.5 ... 30 min 2 CO contacts, 0.05 ... 1 h positively driven 5 ... 100 min and hard gold- 0.15 ... 3 h plated. 0.5 ... 10 h 8 functions4)5) 1.5 ... 30 h 5 ... 100 h 2) -24/100 ... 127 24/200 ... 240 24 ... 2403) 12 24 24 24 ... 2403) A } } } 3RP15 05-1AA40 3RP15 05-1AQ30 3RP15 05-1AP30 3RP15 05-1AW30 1 1 1 1 1 unit 1 unit 1 unit 1 unit 101 101 101 101 0.125 0.140 0.141 0.136 24/100 ... 127 24/200 ... 240 24 ... 2403) 400 ... 440 24 24 24 ... 2403) -- } } } A 3RP15 05-1BQ30 3RP15 05-1BP30 3RP15 05-1BW30 3RP15 05-1BT20 1 1 1 1 1 unit 1 unit 1 unit 1 unit 101 101 101 101 0.162 0.161 0.168 0.169 24 ... 240 24 ... 240 } 3RP15 05-1RW30 1 1 unit 101 0.169 } } } 3RP15 11-1AQ30 3RP15 11-1AP30 1 1 1 unit 1 unit 101 101 0.108 0.108 3RP15 12-1AQ30 3RP15 12-1AP30 1 1 1 unit 1 unit 101 101 0.107 0.104 } 3RP15 13-1AQ30 3RP15 13-1AP30 1 1 1 unit 1 unit 101 101 0.107 0.108 3RP15 1. timing relays, ON-delay, 1 time setting range with LED and 1 CO contact 0.5 ... 10 s 24/100 ... 127 24/200 ... 240 24 24 1.5 ... 30 s 24/100 ... 127 24/200 ... 240 24 24 24/100 ... 127 24/200 ... 240 24 24 5 ... 100 s } } 3RP15 1.-1A... 3RP15 25 timing relays, ON-delay, 15 time setting ranges 2 CO contacts 3RP15 25.1A... 0.05 ... 1 s 0.15 ... 3 s 0.5 ... 10 s 1.5 ... 30 s 0.05 ... 1 min 5 ... 100 s 0.15 ... 3 min 0.5 ... 10 min 1.5 ... 30 min 0.05 ... 1 h 5 ... 100 min 0.15 ... 3 h 0.5 ... 10 h 1.5 ... 30 h 5 ... 100 h 2) 24/100 ... 127 24/200 ... 240 24 24 } } 3RP15 25-1AQ30 3RP15 25-1AP30 1 1 1 unit 1 unit 101 101 0.109 0.104 42 ... 48/60 42 ... 48/ 606) 24 24 24 ... 2403) A 3RP15 25-1BR30 1 1 unit 101 0.152 } } } 3RP15 25-1BQ30 3RP15 25-1BP30 3RP15 25-1BW30 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.152 0.155 0.159 24...666) 90...2403) A } 3RP15 27-1EC30 3RP15 27-1EM30 1 1 1 unit 1 unit 101 101 0.099 0.100 24/100 ... 127 24/200 ... 2406) 24 ... 240 3RP15 27 timing relays, ON-delay, two-wire design, 4 time setting ranges 1 NO contact 0.05 ... 1 s (semiconductor) 0.2 ... 4 s 1.5 ... 30 s 12 ... 240 s 24 ... 66 90 ... 240 3RP15 27-1E... 1) For functions, see 3RP19 01-0. label set. 2) With switch position , no timing. For test purposes (ON/OFF function) on site. Relay is constantly on when activated, or relay remains constantly off when activated. Depending on which function is set. 5) The changeover contacts are actuated simultaneously, as a result of which only 8 functions are selectable (no wye-delta, no instantaneous contact). 6) Operating range 0.8 to 1.1 x Us. 3) Operating range 0.7 to 1.1 x Us. 4) Positively driven: NO and NC are never closed simultaneously; contact gap >= 0.5 mm is ensured, minimum make-break capacity 12 V, 3 mA. * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/29 7 with LED and 1 CO contact 3RP, 7PV Timing Relays 3RP15 timing relays in industrial enclosure, 22.5 mm Solid-state timing relays for general use in control systems and mechanical engineering with: * 1 changeover contact or 2 changeover contacts Version * Single or selectable time setting ranges * Switching position indication by LED * Voltage indication by LED Time setting Rated control supply voltage DT Spring-loaded terminal range t Us adjustable by rotary switch to AC 50/60 Hz DC V V Order No. PU PS* (UNIT, SET, M) PG Weight per PU approx. Price per PU kg 3RP15 05 timing relays, multifunction, 15 time setting ranges The functions can be adjusted by means of rotary switches. Indicator labels can be used to adjust different functions of the 3RP15 05 timing relay clearly and unmistakably. The corresponding labels can be ordered as an accessory. The same potential must be applied to terminals A. and B.1) with LED and 1 CO contact, 8 functions 0.05 ... 1 s 0.15 ... 3 s 0.5 ... 10 s 2 CO contacts, 1.5 ... 30 s 0.05 ... 1 min 16 functions 5 ... 100 s 0.15 ... 3 min 2 CO contacts, 0.5 ... 10 min positively driven 1.5 ... 30 min and hard gold- 0.05 ... 1 h plated. 5 ... 100 min 8 functions4)5) 0.15 ... 3 h 0.5 ... 10 h 1.5 ... 30 h 5 ... 100 h 2) 24/100 ... 127 24/200 ... 240 24 ... 2403) 24 C 24 A 3) 24 ... 240 A 3RP15 05-2AQ30 3RP15 05-2AP30 3RP15 05-2AW30 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.125 0.126 0.132 24/100 ... 127 24/200 ... 240 24 ... 2403) 24 A 24 A 24 ... 2403) A 3RP15 05-2BQ30 3RP15 05-2BP30 3RP15 05-2BW30 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.142 0.137 0.143 24 ... 240 24 ... 240 A 3RP15 05-2RW30 1 1 unit 101 0.143 3RP15 1. timing relays, ON-delay, 1 time setting range with LED and 1 CO contact 0.5 ... 10 s 24/100 ... 127 24/200 ... 240 24 24 C A 3RP15 11-2AQ30 3RP15 11-2AP30 1 1 1 unit 1 unit 101 101 0.092 0.092 1.5 ... 30 s 24/100 ... 127 24/200 ... 240 24 24 C A 3RP15 12-2AQ30 3RP15 12-2AP30 1 unit 1 unit 101 101 0.092 0.097 5 ... 100 s 24/100 ... 127 24/200 ... 240 24 24 C C 3RP15 13-2AQ30 3RP15 13-2AP30 1 1 1 1 1 unit 1 unit 101 101 0.094 0.094 24/100 ... 127 24/200 ... 240 24 24 C A 3RP15 25-2AQ30 3RP15 25-2AP30 1 1 1 unit 1 unit 101 101 0.095 0.093 24/100 ... 127 24/200 ... 240 24 ... 2406) 24 C 24 A 3) 24 ... 240 A 3RP15 25-2BQ30 3RP15 25-2BP30 3RP15 25-2BW30 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.128 0.127 0.134 24...666) 90...240 3) 3RP15 27-2EC30 3RP15 27-2EM30 1 1 1 unit 1 unit 101 101 0.090 0.090 3RP15 25 timing relays, ON-delay, 15 time setting ranges with LED and 1 CO contact 7 2 CO contacts 0.05 ... 1 s 0.15 ... 3 s 0.5 ... 10 s 1.5 ... 30 s 0.05 ... 1 min 5 ... 100 s 0.15 ... 3 min 0.5 ... 10 min 1.5 ... 30 min 0.05 ... 1 h 5 ... 100 min 0.15 ... 3 h 0.5 ... 10 h 1.5 ... 30 h 5 ... 100 h 2) 3RP15 27 timing relays, ON-delay, two-wire design, 4 time setting ranges 1 NO contact 0.05 ... 1 s (semiconductor) 0.2 ... 4 s 1.5 ... 30 s 12 ... 240 s 24 ... 66 90 ... 240 C C 1) For functions, see 3RP19 01-0. label set. 2) With switch position , no timing. For test purposes (ON/OFF function) on site. Relay is constantly on when activated, or relay remains constantly off when activated. Depending on which function is set. 3) Operating range 0.7 to 1.1 x Us. 4) Positively driven: NO and NC are never closed simultaneously; contact gap >= 0.5 mm is ensured, minimum make-break capacity 12 V, 3 mA. 5) The changeover contacts are actuated simultaneously, as a result of which only 8 functions are selectable (no wye-delta, no instantaneous contact). 6) Operating range 0.8 to 1.1 x Us. * You can order this quantity or a multiple thereof. 7/30 Siemens LV 1 * 2006 3RP, 7PV Timing Relays 3RP15 timing relays in industrial enclosure, 22.5 mm Solid-state timing relays for general use in control systems and mechanical engineering with: * 1 changeover contact or 2 changeover contacts Version * Single or selectable time setting ranges * Switching position indication by LED * Voltage indication by LED Time setting Rated control supply voltage Us DT Screw-type connection range t adjustable by rotary switch to AC 50/60 Hz DC V V Order No. PU (UNIT, SET, M) PS* PG Weight per PU approx. Price per PU kg 3RP15 3. timing relays, OFF-delay, with auxiliary voltage, 1 time setting range with LED and 0.5 ... 10 s 1 CO contact The same potential 1.5 ... 30 s must be applied to terminals A and B. 5 ... 100 s 24/100 ... 127 24/200 ... 240 24 24 A } 3RP15 31-1AQ30 3RP15 31-1AP30 1 1 1 unit 1 unit 101 101 0.140 0.140 24/100 ... 127 24/200 ... 240 24 24 A } 3RP15 32-1AQ30 3RP15 32-1AP30 1 1 1 unit 1 unit 101 101 0.138 0.139 24/100 ... 127 24/200 ... 240 24 24 A } 3RP15 33-1AQ30 3RP15 33-1AP30 1 1 1 unit 1 unit 101 101 0.139 0.140 24 100 ... 127 200 ... 240 } 242) 100...1273) } 200...2403) } 3RP15 40-1AB30 3RP15 40-1AJ30 3RP15 40-1AN30 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.116 0.119 0.120 24 100 ... 127 200 ... 240 242) } 100...1273) A 3) } 200...240 3RP15 40-1BB30 3RP15 40-1BJ30 3RP15 40-1BN30 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.159 0.161 0.161 A 3RP15 55-1AR30 1 1 unit 101 0.111 } } 3RP15 55-1AQ30 3RP15 55-1AP30 1 1 1 unit 1 unit 101 101 0.111 0.111 A } 3RP15 60-1SQ30 3RP15 60-1SP30 1 1 1 unit 1 unit 101 101 0.172 0.175 3RP15 3.-1A... 3RP15 40 timing relays, OFF-delay, without auxiliary voltage, 7 time setting ranges1) with LED and 1 CO contact 2 CO contacts 0.05 ... 1 s 0.15 ... 3 s 0.3 ... 6 s 0.5 ... 10 s 1.5 ... 30 s 3 ... 60 s 5 ... 100 s 3RP15 40-1.A... 3RP15 55 timing relays, clock-pulse relay, 15 time setting ranges with LED and 1 CO contact 3RP15 55-1A... 0.05 ... 1 s 0.15 ... 3 s 0.5 ... 10 s 1.5 ... 30 s 0.05 ... 1 min 5 ... 100 s 0.15 ... 3 min 0.5 ... 10 min 1.5 ... 30 min 0.05 ... 1 h 5 ... 100 min 0.15 ... 3 h 0.5 ... 10 h 1.5 ... 30 h 5 ... 100 h 4) 42 ... 48/60 24/100 ... 127 24/200 ... 240 42...48/ 605) 24 24 3 NO contacts3) (common contact root terminal 17) wye-delta 24/100 ... 127 1 ... 20 s, 24/200 ... 240 overtravel time (idling) 30 ... 600 s 24 24 7 3RP15 60 timing relays, wye-delta function, dead interval 50 ms and overtravel time, 1 time setting range 3RP15 60-1S... 3RP15 7. timing relays, wye-delta function6), dead interval 50 ms, 1 time setting range 1 NO contact instantaneous and 1 NO contact delayed (common contact root terminal 17) 1 ... 20 s 24/100 ... 127 24/200 ... 240 200 ... 240/ 380 ...440 24 24 -- } } B 3RP15 74-1NQ30 3RP15 74-1NP30 3RP15 74-1NM20 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.113 0.113 0.113 3 ... 60 s 24/100 ... 127 24/200 ... 240 200 ... 240/ 380 ...440 24 24 -- } } B 3RP15 76-1NQ30 3RP15 76-1NP30 3RP15 76-1NM20 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.112 0.113 0.113 3RP15 7.-1N... 1) Setting of output contacts in as-supplied state not defined (bistable relay). Application of the control voltage once results in contact changeover to the correct setting. 4) With switch position , no timing. For test purposes (ON/OFF function) on site. For dead time "infinite", the relay is always off. For pulse time "infinite", the relay is always on. 2) Operating range 0.7 to 1.25 x Us. 5) Operating range 0.8 to 1.1 x Us. 3) Operating range 0.85 to 1.1 x Us. 6) For typical circuit see Schematics. * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/31 3RP, 7PV Timing Relays 3RP15 timing relays in industrial enclosure, 22.5 mm Solid-state timing relays for general use in control systems and mechanical engineering with * 1 changeover contact or 2 changeover contacts Version * Single or selectable time setting ranges * Switching position indication by LED * Voltage indication by LED Time setting Rated control supply voltage DT Spring-loaded terminal range t Us adjustable by rotary switch to AC 50/60 Hz DC V V Order No. PU (UNIT, SET, M) PS* PG Weight per unit/ set/ meter approx. Price per PU kg 3RP15 3. timing relays, OFF-delay, with auxiliary voltage, 1 time setting range with LED and 0.5 ... 10 s 1 CO contact The same 1.5 ... 30 s potential must be applied to terminals A and 5 ... 100 s B 24/100 ... 127 24/200 ... 240 24 24 C A 3RP15 31-2AQ30 3RP15 31-2AP30 1 1 1 unit 1 unit 101 101 0.124 0.122 24/100 ... 127 24/200 ... 240 24 24 C C 3RP15 32-2AQ30 3RP15 32-2AP30 1 unit 1 unit 101 101 0.125 0.121 24/100 ... 127 24/200 ... 240 24 24 C C 3RP15 33-2AQ30 3RP15 33-2AP30 1 1 1 1 1 unit 1 unit 101 101 0.123 0.125 3RP15 40 timing relays, OFF-delay, without auxiliary voltage, 7 time setting ranges1) with LED and 1 CO contact 2 CO contacts 0.05 ... 1 s 0.15 ... 3 s 0.3 ... 6 s 0.5 ... 10 s 1.5 ... 30 s 3 ... 60 s 5 ... 100 s 24 100 ... 127 200 ... 240 242) 100...1273) 200...2403) A A A 3RP15 40-2AB30 3RP15 40-2AJ30 3RP15 40-2AN30 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.105 0.108 0.110 24 100 ... 127 200 ... 240 242) 100...1273) 200...2403) A C C 3RP15 40-2BB30 3RP15 40-2BJ30 3RP15 40-2BN30 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.136 0.136 0.136 42...48/605) C 24 C 24 A 3RP15 55-2AR30 3RP15 55-2AQ30 3RP15 55-2AP30 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.102 0.100 0.104 C 3RP15 60-2SP30 1 1 unit 101 0.152 3RP15 55 timing relays, clock-pulse relay, 15 time setting ranges with LED and 1 changeover contact 0.05 ... 1 s 0.15 ... 3 s 0.5 ... 10 s 1.5 ... 30 s 0.05 ... 1 min 5 ... 100 s 0.15 ... 3 min 0.5 ... 10 min 1.5 ... 30 min 0.05 ... 1 h 5 ... 100 min 0.15 ... 3 h 0.5 ... 10 h 1.5 ... 30 h 5 ... 100 h 4) 42 ... 48/60 24/100 ... 127 24/200 ... 240 3RP15 60 timing relays, wye-delta function, dead interval 50 ms and overtravel time, 1 time setting range 7 3 NO contacts3) (common contact root terminal 17) wye-delta 24/200 ... 240 1 ... 20 s, overtravel time (idling) 30 ... 600 s 24 3RP15 7. timing relays, wye-delta function6), dead interval 50 ms, 1 time setting range 1 NO contact 1 ... 20 s instantaneous and 1 NO contact delayed (common 3 ... 60 s contact root terminal 17) 24/200 ... 240 200 ... 240/ 380 ...440 24 A B 3RP15 74-2NP30 3RP15 74-2NM20 1 1 1 unit 1 unit 101 101 0.104 0.100 24/100 ... 127 24/200 ... 240 200 ... 240/ 380 ... 440 24 24 C A B 3RP15 76-2NQ30 3RP15 76-2NP30 3RP15 76-2NM20 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.102 0.104 0.100 1) Setting of output contacts in as-supplied state not defined (bistable relay). Application of the control voltage once results in contact changeover to the correct setting. 2) Operating range 0.7 to 1.25 x Us. 3) Operating range 0.85 to 1.1 x Us. 4) With switch position , no timing. For test purposes (ON/OFF function) on site. For dead time "infinite", the relay is always off. For pulse time "infinite", the relay is always on. 5) Operating range 0.8 to 1.1 x Us. 6) For typical circuit see Schematics. * You can order this quantity or a multiple thereof. 7/32 Siemens LV 1 * 2006 3RP, 7PV Timing Relays 3RP15 timing relays in industrial enclosure, 22.5 mm Accessories Version Function Code Appliletter cation DT Order No. Price PU PS* per PU (UNIT, SET, M) PG Weight per PU approx. kg Label sets Accessory for 3RP 15 05 (not included in the scope of supply). The label set offers the possibility of labeling timing relays with the set function in English and German. 1 label set (1 unit) with 8 functions With ON-delay A OFF-delay with auxiliary voltage B ON-delay and OFF-delay with auxiliary voltage C Flashing, starting with interval D Passing make contact E Passing break contact with auxiliary voltage F for } devices with 1 CO contact and 3RP15 05-.RW30 3RP19 01-0A 1 5 units 101 0.003 for } devices with 2 CO contacts 3RP19 01-0B 1 5 units 101 0.006 100 340 units 101 22.000 Pulse-forming with auxiliary voltage G Additive ON-delay with auxiliary voltage 1 label set (1 unit) with 16 functions H With ON-delay A OFF-delay with auxiliary voltage B ON-delay and OFF-delay with auxiliary voltage C Flashing, starting with interval D Passing make contact E Passing break contact with auxiliary voltage F Pulse-forming with auxiliary voltage G Additive ON-delay with auxiliary H* voltage and instantaneous contact ON-delay and instantaneous contact A* OFF-delay with auxiliary voltage and instantaneous contact B* ON-delay and OFF-delay with C* auxiliary voltage and instantaneous contact Flashing, starting with interval, and D* instantaneous contact Passing make contact and instantaneous contact E* 7 Passing break contact with F* auxiliary voltage and instantaneous contact Pulse-forming with auxiliary voltage G* and instantaneous contact Wye-delta function *D Blank labeling plates Blank labeling plates, 20 mm x 7 mm, pastel turquoise1) C 3RT19 00-1SB20 Covering caps and push-in lugs Push-in lugs for screw mounting for devices with 1 or 2 CO contacts } 3RP19 03 1 10 units 101 0.002 Sealable caps for securing against unauthorized adjustment of setting knobs for devices with 1 or 2 CO contacts } 3RP19 02 1 5 units 101 0.004 1) Computer labeling system for individual labeling of device labeling plates available from: murrplastik Systemtechnik GmbH. * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/33 3RP, 7PV Timing Relays 3RP20 timing relays, 45 mm Overview Application Standards The timing relays comply with: * EN 60721-3-3 "Environmental conditions" * EN 61812-1/DIN VDE 0435 Part 2021 "Solid-state relays, timing relays" * EN 61000-6-2 and EN 61000-6-4 "Electromagnetic compatibility" * EN 60947-5-1; (VDE 0660 Part 200) "Low-voltage controlgear, switchgear and systems - Electromechanical controlgear" * EN 61140 "Safe electrical isolation" 3RP20 timing relay, width 45 mm LED for indicating "Time relay excited" (left) LED for indicating "Relay switched" (right) Function switch Time setting range selector switch NSB0_01424 Device labeling plate Accessories Label set for marking the multifunction relay 7 7/34 Siemens LV 1 * 2006 Time setting range adjuster, analog Timing relays are used in control, starting, and protective circuits for all switching operations involving time delays. They guarantee a high level of functionality and a high repeat accuracy of timer settings. 3RP, 7PV Timing Relays 3RP20 timing relays, 45 mm Selection and ordering data Multifunction switches1). The functions can be adjusted by means of rotary Indicator labels can be used to adjust different functions of the 3RP20 05 timing relay clearly and unmistakably. Version Time setting range The corresponding labels can be ordered as an accessory. The same potential must be applied to terminals A. and B.. Rated control supply voltage DT Screw-type connection Us AC 50-60 Hz DC V V Order No. PU (UNIT, SET, M) PS* PG Weight per PU approx. Price per PU kg 3RP20 05 timing relays, multifunction, 15 time setting ranges with LED and 1 CO contact, 8 functions 3RP20 05-1BW30 0.05 ... 1 s 24/100 ... 127 0.15 ... 3 s 24/200 ... 240 0.5 ... 10 s 1)2) 1.5 ... 30 s with LED and 0.05 ... 1 min 24 ... 2404) 2 CO contacts, 5 ... 100 s 16 functions1) 0.15 ... 3 min 0.5 ... 10 min 1.5 ... 30 min 0.05 ... 1 h 5 ... 100 min 0.15 ... 3 h 0.5 ... 10 h 1.5 ... 30 h 5 ... 100 h 3) } } 3RP20 05-1AQ30 3RP20 05-1AP30 1 1 1 unit 1 unit 101 101 0.118 0.119 24 ... 2405) D 3RP20 05-1BW30 1 1 unit 101 0.128 3RP20 25-1AQ30 3RP20 25-1AP30 1 1 1 unit 1 unit 101 101 0.106 0.106 24 24 3RP20 25 timing relays, ON-delay, 15 time setting ranges 3RP20 25-1AP30 with LED and 0.05 ... 1 s 24/100 ... 127 1 CO contact2) 0.15 ... 3 s 24/200 ... 240 0.5 ... 10 s 1.5 ... 30 s 0.05 ... 1 min 5 ... 100 s 0.15 ... 3 min 0.5 ... 10 min 1.5 ... 30 min 0.05 ... 1 h 5 ... 100 min 0.15 ... 3 h 0.5 ... 10 h 1.5 ... 30 h 5 ... 100 h 3) 24 24 } } 1) For functions, see 3PR19 01-0. label set. 2) Units with safe electrical isolation. 7 3) With switch position , no timing. For test purposes (ON/OFF function) on site. Relay is constantly on when activated, or relay remains constantly off when activated. Depending on which function is set. 4) Operating range 0.8 ... 1.1 x Us. 5) Operating range 0.7 ... 1.1 x Us. * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/35 3RP, 7PV Timing Relays 3RP20 timing relays, 45 mm Selection and ordering data Multifunction The functions can be adjusted by means of rotary switches1). Indicator labels can be used to adjust different functions of the 3RP20 05 timing relay clearly and unmistakably. Version Time setting range t Rated control supply voltage Us AC 50-60 Hz DC V V The corresponding labels can be ordered as an accessory. The same potential must be applied to terminals A. and B.. DT Spring-loaded terminal Order No. PU (UNIT, SET, M) PS* PG Weight per PU approx. Price per PU kg 3RP20 05 timing relays, multifunction, 15 time setting ranges with LED and 1 CO contact, 8 functions1)2) 0.05 ... 1 s 0.15 ... 3 s 0.5 ... 10 s 1.5 ... 30 s with LED and 2 CO contacts, 0.05 ... 1 min 5 ... 100 s 16 functions1) 0.15 ... 3 min 0.5 ... 10 min 1.5 ... 30 min 0.05 ... 1 h 5 ... 100 min 0.15 ... 3 h 0.5 ... 10 h 1.5 ... 30 h 5 ... 100 h 3) 24/ 100 ... 127 24 24/ 200 ... 240 24 24 ... 2404) D } 3RP20 05-2AQ30 3RP20 05-2AP30 1 1 1 unit 1 unit 101 101 0.120 0.121 24 ... 2405) A 3RP20 05-2BW30 1 1 unit 101 0.131 3RP20 25-2AQ30 3RP20 25-2AP30 1 1 1 unit 1 unit 101 101 0.110 0.108 3RP20 25 timing relays, ON-delay, 15 time setting ranges with LED and 1 CO contact2) 0.05 ... 1 s 0.15 ... 3 s 0.5 ... 10 s 1.5 ... 30 s 0.05 ... 1 min 5 ... 100 s 0.15 ... 3 min 0.5 ... 10 min 1.5 ... 30 min 0.05 ... 1 h 5 ... 100 min 0.15 ... 3 h 0.5 ... 10 h 1.5 ... 30 h 5 ... 100 h 3) 24/ 100 ... 127 24 24/ 200 ... 240 24 D A 1) For functions, see 3PR19 01-0. label set. 7 2) Units with safe electrical isolation. 3) With switch position , no timing. For test purposes (ON/OFF function) on site. Relay is constantly on when activated, or relay remains constantly off when activated. Depending on which function is set. 4) Operating range 0.8 to 1.1 x Us. 5) Operating range 0.7 to 1.1 x Us. * You can order this quantity or a multiple thereof. 7/36 Siemens LV 1 * 2006 3RP, 7PV Timing Relays 3RP20 timing relays, 45 mm Accessories Version Function Code Appliletter cation DT Order No. Price PU PS* per PU (UNIT, SET, M) PG Weight per PU approx. kg Label sets Accessory for 3RP 15 05 (not included in the scope of supply). The label set offers the possibility of labeling timing relays with the set function in English and German. 1 label set (1 unit) with 8 functions 1 label set (1 unit) with 16 functions With ON-delay A OFF-delay with auxiliary voltage B ON-delay and OFF-delay with auxiliary voltage C Flashing, starting with interval D Passing make contact E Passing break contact with auxiliary voltage F Pulse-forming with auxiliary voltage G Additive ON-delay with auxiliary voltage H With ON-delay A OFF-delay with auxiliary voltage B ON-delay and OFF-delay with auxiliary voltage C Flashing, starting with interval D Passing make contact E Passing break contact with auxiliary voltage F Pulse-forming with auxiliary voltage G Additive ON-delay with auxiliary voltage and instantaneous contact H* for } devices with 1 CO contact and 3RP15 05-.RW30 3RP19 01-0A 1 5 units 101 0.003 for } devices with 2 CO contacts 3RP19 01-0B 1 5 units 101 0.006 100 340 units 101 22.000 ON-delay and instantaneous contact A* ON-delay and OFF-delay with auxiliary voltage and instantaneous contact C* Flashing, starting with interval, and instantaneous contact D* Passing make contact and instantaneous contact E* Passing break contact with auxiliary voltage and instantaneous contact F* Pulse-forming with auxiliary voltage and instantaneous contact G* Wye-delta function *D 7 OFF-delay with auxiliary voltage and B* instantaneous contact Blank labeling plates Blank labeling plates, 20 mm x 7 mm, pastel turquoise1) C 3RT19 00-1SB20 1) Computer labeling system for individual labeling of device labeling plates available from: murrplastik Systemtechnik GmbH. * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/37 3RP, 7PV Timing Relays 7PV timing relays for panel mounting Selection and ordering data Version Time setting range t Rated control supply DT Order No. voltage Us Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. AC 50 ... 60 Hz DC V V kg 7PV33 48 timing relays, multifunction, digitally adjustable, 11 time setting ranges 7PV33 48-2AX34 with LCD display, 0.01 s ... 9999 h 24/110 ... 240 1 CO contact * ON-delay * OFF-delay with auxiliary voltage1) * Flashing, starting with pulse * Flashing, starting with interval * Passing make contact * Pulse-forming 24 } 1 7PV33 48-2AX34 1 unit 101 0.133 Non-volatile setting parameters; the elapsed time is not saved2) 1) Function is retriggerable, i.e. a new start signal at terminal B after the operating time has started resets the operating time to zero. 2) Possibility of connecting parallel load to terminal B1! Accessories Version Function DT Order No. Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg Sockets Sockets 11-pole socket with rear connection } 7PX9 921 1 1 unit 101 0.049 11-pole socket for DIN rail and mounting } LZX:MT78750 1 1 unit 101 0.063 7 7PX9 921 LZX:MT78750 * You can order this quantity or a multiple thereof. 7/38 Siemens LV 1 * 2006 3RP, 7PV Timing Relays 3RT19 timing relays for mounting to contactors Selection and ordering data For con- Auxiliary contacts tactors Function Timing relay energized Timing relay closed Contact open Type Rated control Time supply voltage setting Us range t V DT Order No. Price PU per PU (UNIT, SET, M) PS* PG s Weight per PU approx. kg for size S001), with screw connection Terminal designations acc. to EN 46199 Part 5 * ON-delay (varistor integrated) 3RT10 1, 1 NO + 1 NC AC/DC 24 3RH11 A1/A2 3RT19 16-2EJ11 3RT19 16-2EJ21 3RT19 16-2EJ31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.085 0.084 0.086 AC 100 ... 127 0.05 ... 1 C 0.5 ... 10 } 5 ... 100 } 3RT19 16-2EC11 3RT19 16-2EC21 3RT19 16-2EC31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.087 0.087 0.086 AC 200 ... 240 0.05 ... 1 D 0.5 ... 10 } 5 ... 100 } 3RT19 16-2ED11 3RT19 16-2ED21 3RT19 16-2ED31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.088 0.089 0.090 * OFF-delay without auxiliary voltage (varistor integrated)2) 1 NO + 1 NC AC/DC 24 0.05 ... 1 } > 200 ms 0.5 ... 10 } 5 ... 100 } A1/A2 3RT19 16-2FJ11 3RT19 16-2FJ21 3RT19 16-2FJ31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.087 0.088 0.089 NSB00933 0.05 ... 1 } 0.5 ... 10 } 5 ... 100 B 27/28 35/36 t NSB00934 3RT19 16-2... 27/28 35/36 t AC 100 ... 127 0.05 ... 1 D 0.5 ... 10 } 5 ... 100 B 3RT19 16-2FK11 3RT19 16-2FK21 3RT19 16-2FK31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.086 0.087 0.088 AC 200 ... 240 0.05 ... 1 D 0.5 ... 10 } 5 ... 100 } 3RT19 16-2FL11 3RT19 16-2FL21 3RT19 16-2FL31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.089 0.089 0.089 0.5 ... 10 B B B 3RT19 16-2LJ21 3RT19 16-2LC21 3RT19 16-2LD21 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.083 0.085 0.085 1.5 ... 30 } D } 3RT19 16-2GJ51 3RT19 16-2GC51 3RT19 16-2GD51 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.086 0.087 0.090 AC/DC 24 0.05 ... 1 D 0.5 ... 10 } 5 ... 100 A 3RT19 26-2EJ11 3RT19 26-2EJ21 3RT19 26-2EJ31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.081 0.081 0.082 AC 100 ... 127 0.05 ... 1 C 0.5 ... 10 } 5 ... 100 D 3RT19 26-2EC11 3RT19 26-2EC21 3RT19 26-2EC31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.083 0.083 0.083 AC 200 ... 240 0.05 ... 1 D 0.5 ... 10 } 5 ... 100 B 3RT19 26-2ED11 3RT19 26-2ED21 3RT19 26-2ED31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.085 0.085 0.085 0.05 ... 1 } 0.5 ... 10 } 5 ... 100 } 3RT19 26-2FJ11 3RT19 26-2FJ21 3RT19 26-2FJ31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.085 0.084 0.085 AC 100 ... 127 0.05 ... 1 D 0.5 ... 10 } 5 ... 100 C 3RT19 26-2FK11 3RT19 26-2FK21 3RT19 26-2FK31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.087 0.086 0.087 AC 200 ... 240 0.05 ... 1 D 0.5 ... 10 A 5 ... 100 A 3RT19 26-2FL11 3RT19 26-2FL21 3RT19 26-2FL31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.086 0.084 0.086 1.5 ... 30 } } } 3RT19 26-2GJ51 3RT19 26-2GC51 3RT19 26-2GD51 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.084 0.085 0.088 * OFF-delay with auxiliary voltage 1 CO contact AC/DC 24 AC 100 ... 127 AC 200 ... 240 * Wye-delta function (varistor integrated) 1 NO, delayed + 1 NO, AC/DC 24 instantaneous, dead time 50 ms AC 100 ... 127 AC 200 ... 240 NSB00935 A1/A2 Y 27/28 D 37/38 50 ms t with screw connection NSB00936 * ON-delay 3RT10 2, 1 NO + 1 NC 3RT10 3, 3RT10 4 A1/A2 -7/-8 -5/-6 t 3RT19 26-2... * OFF-delay without auxiliary voltage2) 1 NO + 1 NC AC/DC 24 > 200 ms NSB00937 A1/A2 -7/-8 -5/-6 t NSB00938 * Wye-delta function 1 NO, delayed + 1 NO, AC/DC 24 instantaneous, dead time 50 ms AC 100 ... 127 AC 200 ... 240 A1/A2 Y -7/-8 D -7/-8 t 50 ms 1) The terminals for the rated control supply voltage are connected to the contactor beneath by the integrated spring-type contacts of the solidstate time-delay auxiliary switch block when mounting. 3) The terminals A1 and A2 for the rated control supply voltage of the solid-state time-delay auxiliary switch block must be connected to the corresponding contactor by connecting leads. 2) Setting of output contacts in as-supplied state not defined (bistable relay). Application of the control voltage once results in contact changeover to the correct setting. * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/39 7 for sizes S0 to S123), 3RP, 7PV Timing Relays 3RT19 timing relays for mounting to contactors For Function contactors Rated control Time supply voltage Us setting range t DT Order No. Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. Timing relay energized Contact closed Contact open Contactor energized Type V s kg for size S00, with semiconductor output and screw connection for mounting onto the front of contactors The electrical connection between the time-relay block and the contactor beneath is established automatically when it is snapped on. * ON-delay, two-wire design (varistor integrated) A1/A2 Timing relay 3RT19 16-2C... NSB00939a 3RT1. 1, 3RH11 t A1/A2 Contactor AC/DC 24 ... 66 0.05 ... 1 0.5 ... 10 5 ... 100 B } B 3RT19 16-2CG11 3RT19 16-2CG21 3RT19 16-2CG31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.051 0.051 0.054 AC/DC 90 ... 240 0.05 ... 1 0.5 ... 10 5 ... 100 D } } 3RT19 16-2CH11 3RT19 16-2CH21 3RT19 16-2CH31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.052 0.052 0.051 * OFF-delay with auxiliary voltage (varistor integrated) NSB00940a A1/A2 Timing relay B1/A2 > 35 ms 3RT19 16-2D... A1/A2 Contactor AC/DC 24 ... 66 0.05 ... 1 0.5 ... 10 5 ... 100 C B B 3RT19 16-2DG11 3RT19 16-2DG21 3RT19 16-2DG31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.057 0.057 0.057 AC/DC 90 ... 240 0.05 ... 1 0.5 ... 10 5 ... 100 D } B 3RT19 16-2DH11 3RT19 16-2DH21 3RT19 16-2DH31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.053 0.060 0.058 t for sizes S0 to S3, with semiconductor output and screw connection for mounting onto coil terminals on top of the contactors The electrical connection between the relay block and the corresponding contactor is established by screwing the two connecting pins of the time-relay block to coil terminals A1/A2 on top of the contactor. * ON-delay, two-wire design (varistor integrated) A1/A2 Timing relay NSB00939a 3RT10 2, 3RT10 3, 3RT10 41) t A1/A2 Contactor AC/DC 24 ... 66 0.05 ... 1 0.5 ... 10 5 ... 100 D B D 3RT19 26-2CG11 3RT19 26-2CG21 3RT19 26-2CG31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.048 0.049 0.048 AC/DC 90 ... 240 0.05 ... 1 0.5 ... 10 5 ... 100 } } } 3RT19 26-2CH11 3RT19 26-2CH21 3RT19 26-2CH31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.048 0.047 0.048 3RT19 26-2C... * OFF-delay with auxiliary voltage (varistor integrated) NSB00940a A1/A2 Timing relay B1/A2 7 > 35 ms 3RT19 26-2D... A1/A2 Contactor AC/DC 24 ... 66 0.05 ... 1 0.5 ... 10 5 ... 100 D D D 3RT19 26-2DG11 3RT19 26-2DG21 3RT19 26-2DG31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.050 0.051 0.051 AC/DC 90 ... 240 0.05 ... 1 0.5 ... 10 5 ... 100 C D C 3RT19 26-2DH11 3RT19 26-2DH21 3RT19 26-2DH31 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.050 0.050 0.050 t 1) Not for 3RT10 4 contactor with 24 to 42 V rated control supply voltage. * You can order this quantity or a multiple thereof. 7/40 Siemens LV 1 * 2006 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Line monitoring Overview Application The relays are used above all for mobile equipment, e.g. air conditioning compressors, refrigerating containers, building site compressors and cranes. Function Application Phase sequence * Direction of rotation of the drive Phase failure * A fuse has tripped * Failure of the control supply voltage * Broken cable Phase unbalance * Overheating of the motor due to asymmetrical voltage * Detection of asymmetrically loaded networks Undervoltage * Increased current on a motor with corresponding overheating * Unintentional resetting of a device Solid-state line monitoring relays provide maximum protection for mobile machines and plants or for unstable networks. Network and voltage faults can be detected early and rectified before far greater damage ensues. * Network collapse, particularly with battery power Overvoltage * Protection of a plant against destruction due to overvoltage Depending on the version, the relays monitor phase sequence, phase failure with and without N conductor monitoring, phase unbalance, undervoltage or overvoltage. With the 3UG46 17 or 3UG46 18 relay, a wrong direction of rotation can also be corrected automatically. Benefits 7 * Can be used without auxiliary voltage in any network from 160 to 690 V AC worldwide thanks to wide voltage range * Variably adjustable to overvoltage, undervoltage or window monitoring * Freely configurable delay times and reset response * Width 22.5 mm * Permanent display of ACTUAL value and network fault type on the digital variants * Automatic correction of the direction of rotation by distinguishing between network faults and wrong phase sequence * All versions with removable terminal * All versions with screw-type connection or alternatively with innovative spring-loaded terminals Siemens LV 1 * 2006 7/41 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Line monitoring Selection and ordering data Hysteresis Undervoltage detection Overvoltage detection ON-delay Tripping delay Auxiliary contacts Version Rated control DT supply voltage Us CO contact V Screw-type connection Order No. PU PS* (UNIT, SET, M) PG Weight per PU approx. Price per PU kg Monitoring of phase sequence Auto-RESET -- No No -- -- 1 AC 160 ... 260 A 3UG45 11-1AN20 1 1 unit 101 0.147 2 A 3UG45 11-1BN20 1 1 unit 101 0.147 1 AC 320 ... 500 A 3UG45 11-1AP20 1 1 unit 101 0.147 2 A 3UG45 11-1BP20 1 1 unit 101 0.147 1 AC 420 ... 690 A 3UG45 11-1AQ20 1 1 unit 101 0.147 2 A 3UG45 11-1BQ20 1 1 unit 101 0.147 1 AC 160 ... 690 A 3UG45 12-1AR20 1 1 unit 101 0.147 2 A 3UG45 12-1BR20 1 1 unit 101 0.147 3UG45 13-1BR20 1 1 unit 101 0.147 3UG46 14-1BR20 1 1 unit 101 0.147 3UG46 15-1CR20 1 1 unit 101 0.147 3UG46 16-1CR20 1 1 unit 101 0.147 3UG46 17-1CR20 1 1 unit 101 0.147 3UG46 18-1CR20 1 1 unit 101 0.147 Monitoring of phase sequence, phase failure and phase unbalance Auto-RESET, closed-circuit principle, unbalance threshold 10 % -- No No -- -- Monitoring of phase sequence, phase failure, phase unbalance and undervoltage Analog adjustable, Auto-RESET, closed-circuit principle, fixed unbalance threshold 20 % 5 % of set value Yes No -- 0.1 ... 20 2 AC 160 ... 690 A Digitally adjustable, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, unbalance threshold 5 ... 20 % Adjustable Yes 1 ... 20 V No 0.1 ... 20 0.1 ... 20 2 AC 160 ... 690 A Monitoring of phase sequence, phase failure, overvoltage and undervoltage Digitally adjustable, Auto-RESET or manual RESET, open-circuit or closed-circuit principle 7 Adjustable Yes 1 ... 20 V Yes -- 0.1 ... 201) 21) AC 160 ... 690 A Monitoring of phase sequence, phase and N conductor failure, overvoltage and undervoltage Digitally adjustable, Auto-RESET or manual RESET, open-circuit or closed-circuit principle Adjustable Yes 1 ... 20 V Yes -- 0.1 ... 201) 21) AC 160 ... 690 A Automatic correction of the direction of rotation in case of wrong phase sequence, phase failure, phase unbalance, overvoltage and undervoltage Digitally adjustable, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, unbalance threshold 5 ... 20 % Adjustable Yes 1 ... 20 V Yes -- 0.1 ... 20 22) AC 160 ... 690 A Automatic correction of the direction of rotation in case of wrong phase sequence, phase and N conductor failure, phase unbalance, overvoltage and undervoltage Digitally adjustable, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, unbalance threshold 5 ... 20 % Adjustable Yes 1 ... 20 V Yes -- 0.1 ... 20 22) AC 160 ... 690 A 1) 1 CO contact each and 1 tripping delay time each for Umin and Umax. 2) 1 CO contact each for phase sequence correction. 7/42 Siemens LV 1 * 2006 * You can order this quantity or a multiple thereof. Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Line monitoring Hysteresis Undervoltage detection Overvoltage detection ON-delay Tripping delay Auxiliary contacts Version Rated control DT supply voltage Us CO contact V Spring-loaded terminal Order No. PU PS* (UNIT, SET, M) PG Weight per PU approx. Price per PU kg Monitoring of phase sequence Auto-RESET -- No No -- -- 1 AC 160 ... 260 A 3UG45 11-2AN20 1 1 unit 101 0.147 2 A 3UG45 11-2BN20 1 1 unit 101 0.147 1 AC 320 ... 500 A 3UG45 11-2AP20 1 1 unit 101 0.147 2 A 3UG45 11-2BP20 1 1 unit 101 0.147 1 AC 420 ... 690 A 3UG45 11-2AQ20 1 1 unit 101 0.147 2 A 3UG45 11-2BQ20 1 1 unit 101 0.147 Monitoring of phase sequence, phase failure and phase unbalance Auto-RESET, closed-circuit principle, unbalance threshold 10 % -- No No -- -- 1 AC 160 ... 690 A 3UG45 12-2AR20 1 1 unit 101 0.147 2 A 3UG45 12-2BR20 1 1 unit 101 0.147 AC 160 ... 690 A 3UG45 13-2BR20 1 1 unit 101 0.147 3UG46 14-2BR20 1 1 unit 101 0.147 3UG46 15-2CR20 1 1 unit 101 0.140 3UG46 16-2CR20 1 1 unit 101 0.147 3UG46 17-2CR20 1 1 unit 101 0.147 3UG46 18-2CR20 1 1 unit 101 0.147 Monitoring of phase sequence, phase failure, phase unbalance and undervoltage Analog adjustable, Auto-RESET, closed-circuit principle, unbalance threshold 20 % 5 % of set value Yes No -- 0.1 ... 20 2 Digitally adjustable, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, unbalance threshold 5 ... 20 % Adjustable Yes 1 ... 20 V No 0 ... 20 0.1 ... 20 2 AC 160 ... 690 A Monitoring of phase sequence, phase failure, overvoltage and undervoltage Adjustable Yes 1 ... 20 V Yes -- 0.1 ... 201) 21) AC 160 ... 690 A 7 Digitally adjustable, Auto-RESET or manual RESET, open-circuit or closed-circuit principle Monitoring of phase sequence, phase and N conductor failure, overvoltage and undervoltage Digitally adjustable, Auto-RESET or manual RESET, open-circuit or closed-circuit principle Adjustable Yes 1 ... 20 V Yes -- 0.1 ... 201) 21) AC 160 ... 690 A Automatic correction of the direction of rotation in case of wrong phase sequence, phase failure, phase unbalance, overvoltage and undervoltage Digitally adjustable, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, unbalance threshold 5 ... 20 % Adjustable Yes 1 ... 20 V Yes -- 0.1 ... 20 22) AC 160 ... 690 A Automatic correction of the direction of rotation in case of wrong phase sequence, phase and N conductor failure, phase unbalance, overvoltage and undervoltage Digitally adjustable, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, unbalance threshold 5 ... 20 % Adjustable Yes 1 ... 20 V Yes -- 0.1 ... 20 22) AC 160 ... 690 A 1) 1 CO contact each and 1 tripping delay time each for Umin and Umax. 2) 1 CO contact each for phase sequence correction. * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/43 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Line monitoring Accessories Application Version DT Order No. Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg Blank labeling plates Blank labeling plates, 20 mm x 7 mm, pastel turquoise1) C 3RT19 00-1SB20 100 340 units 101 22,000 for devices Push-in lugs with 1 or 2 CO for screw mounting contacts } 3RP19 03 1 10 units 101 0,002 for devices Sealable caps with 1 or 2 CO for securing against unauthorized contacts adjustment of setting knobs } 3RP19 02 1 5 units 101 0,004 Covering caps and push-in lugs 7 1) Computer labeling system for individual labeling of device labeling plates available from: murrplastik Systemtechnik GmbH. 7/44 Siemens LV 1 * 2006 * You can order this quantity or a multiple thereof. Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Voltage monitoring Overview Application * Protection of a plant against destruction due to overvoltage * Switch-on of a plant at a defined voltage and higher * Protection against overloaded supply voltages, particularly with battery power * Threshold switch for 0.1 to 10 V analog signals The relays monitor single-phase AC and DC voltages against the set threshold for overshoot and undershoot. The products differ with regard to their power supply (internal or external). Benefits 7 * Variants with wide voltage supply range * Variably adjustable to overvoltage, undervoltage or window monitoring * Freely configurable delay times and RESET response * Width 22.5 mm * Display of ACTUAL value and status messages * All versions with removable "terminals" * All versions with screw-type connection or alternatively with innovative spring-loaded terminals Siemens LV 1 * 2006 7/45 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Voltage monitoring Selection and ordering data Measuring range Hysteresis Rated control supply voltage Us DT Screw-type connection Order No. V V PU PS* (UNIT, SET, M) PG Weight per PU approx. Price per PU kg V Internal power supply without auxiliary supply, On delay and tripping delay can be adjusted separately 0.1 ... 20 s Digitally adjustable, LCD display, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, 1 CO contact AC/DC 17 ... 275 0.1...150 AC/DC 17 ... 275 A 3UG46 33-1AL30 1 1 unit 101 0.147 Supplied from an external auxiliary supply, tripping delay adjustable 0.1 ... 20 s Digitally adjustable, LCD display, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, 1 CO contact AC/DC 0.1 ... 60 0.1...30 AC/DC 10 ... 600 0.1...300 AC/DC 24 A A 3UG46 31-1AA30 3UG46 32-1AA30 1 1 1 unit 1 unit 101 101 0.147 0.147 AC/DC 0.1 ... 60 0.1...30 AC/DC 10 ... 600 0.1...300 AC/DC 24 ... 240 A A 3UG46 31-1AW30 3UG46 32-1AW30 1 1 1 unit 1 unit 101 101 0.147 0.147 Measuring range Hysteresis Rated control supply voltage Us DT Spring-loaded terminal Order No. V V PU PS* (UNIT, SET, M) PG Weight per PU approx. Price per PU kg V Internal power supply without auxiliary supply, On delay and tripping delay can be adjusted separately 0.1 ... 20 s Digitally adjustable, LCD display, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, 1 CO contact AC/DC 17 ... 275 0.1 ... 150 AC/DC 17 ... 275 A 3UG46 33-2AL30 1 1 unit 101 0.147 Supplied from an external auxiliary supply, tripping delay adjustable 0.1 ... 20 s 7 Digitally adjustable, LCD display, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, 1 CO contact AC/DC 0.1 ... 60 0.1 ... 30 AC/DC 10 ... 600 0.1 ... 300 AC/DC 24 A A 3UG46 31-2AA30 3UG46 32-2AA30 1 1 1 unit 1 unit 101 101 0.147 0.147 AC/DC 0.1 ... 60 0.1 ... 30 AC/DC 10 ... 600 0.1 ... 300 AC/DC 24 ... 240 A A 3UG46 31-2AW30 3UG46 32-2AW30 1 1 1 unit 1 unit 101 101 0.147 0.147 DT Order No. Accessories Application Version Price per PU PU PS* (UNIT, SET, M) PG Weight per PU approx. kg Blank labeling plates Blank labeling plates, 20 mm x 7 mm, pastel turquoise1) C 3RT19 00-1SB20 100 340 units for devices with Push-in lugs 1 or 2 CO contacts for screw mounting } 3RP19 03 1 for devices with Sealable caps 1 or 2 CO contacts for securing against unauthorized adjustment of setting knobs } 3RP19 02 1 101 22.000 10 units 101 0.002 5 units 101 0.004 Covering caps and push-in lugs 1) Computer labeling system for individual labeling of device labeling plates available from: murrplastik Systemtechnik GmbH. 7/46 Siemens LV 1 * 2006 * You can order this quantity or a multiple thereof. Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Current monitoring Overview Application * * * * Overcurrent and undercurrent monitoring Monitoring the functionality of electrical loads Open-circuit monitoring Threshold switch for 4 signaling elements from 4 to 20 mA The relays monitor single-phase AC and DC currents against the set threshold for overshoot and undershoot. They differ with regard to their measuring ranges and supply voltage types. Benefits 7 * Variants with wide voltage supply range * Variably adjustable to overvoltage, undervoltage or window monitoring * Freely configurable delay times and RESET response * Width 22.5 mm * Display of ACTUAL value and status messages * All versions with removable terminals * All versions with screw-type connection or alternatively with innovative spring-loaded terminals Siemens LV 1 * 2006 7/47 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Current monitoring Selection and ordering data Measuring range Hysteresis Rated control DT supply voltage Us PU PS* (UNIT, SET, M) Screw-type connection Order No. PG Weight per PU approx. Price per PU kg V Monitoring of undercurrent and overcurrent, On delay and tripping delay can be adjusted separately 0.1 ... 20 s Digitally adjustable, LCD display, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, 1 CO contact AC/DC 3 ... 500 mA 0.1 ... 250 mA AC/DC 24 AC/DC 0.05 ... 10 A 0.01 ... 5 A AC/DC 24 A A 3UG46 21-1AA30 3UG46 22-1AA30 1 1 1 unit 1 unit 101 101 0.147 0.147 AC/DC 3 ... 500 mA 0.1 ... 250 mA AC/DC 0.05 ... 10 A 0.01 ... 5 A AC/DC 24 ... 240 AC/DC 24 ... 240 A A 3UG46 21-1AW30 3UG46 22-1AW30 1 1 1 unit 1 unit 101 101 0.147 0.147 Measuring range Rated control DT supply voltage Us Hysteresis Spring-loaded terminal Order No. PU (UNIT, SET, M) PS* PG Weight per PU approx. Price per PU kg V Monitoring of undercurrent and overcurrent, On delay and tripping delay can be adjusted separately 0.1 ... 20 s Digitally adjustable, LCD display, Auto-RESET or manual RESET, open-circuit or closed-circuit principle, 1 CO contact AC/DC 3 ... 500 mA 0.1 ... 250 mA AC/DC 0.05 ... 10 A 0.01 ... 5 A AC/DC 24 A A 3UG46 21-2AA30 3UG46 22-2AA30 1 1 1 unit 1 unit 101 101 0.147 0.147 AC/DC 3 ... 500 mA 0.1 ... 250 mA AC/DC 0.05 ... 10 A 0.01 ... 5 A AC/DC 24 ... 240 A A 3UG46 21-2AW30 3UG46 22-2AW30 1 1 1 unit 1 unit 101 101 0.147 0.147 DT Order No. Accessories Application Version Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg Blank labeling plates 7 Blank labeling plates, 20 mm x 7 mm, pastel turquoise1) C 3RT19 00-1SB20 100 340 units 101 22.000 for devices Push-in lugs with 1 or 2 CO for screw mounting contacts } 3RP19 03 1 10 units 101 0.002 for devices Sealable caps with 1 or 2 CO for securing against unauthorized contacts adjustment of setting knobs } 3RP19 02 1 5 units 101 0.004 Covering caps and push-in lugs 1) Computer labeling system for individual labeling of device labeling plates available from: murrplastik Systemtechnik GmbH. 7/48 Siemens LV 1 * 2006 * You can order this quantity or a multiple thereof. Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Power factor monitoring Overview Application The 3UG30 14 power factor monitoring device enables the load monitoring of motors. * No-load monitoring * Underload monitoring in the low rating range * Simple power factor monitoring in networks for control of compensation equipment * Broken cable between control cabinet and motor Selection and ordering data Mounting onto standard mounting rail and screw fixing Width 45 mm Relay for power factor monitoring, single and three-phase Version * Monitoring of the power factor for undershoot/overshoot for motor underload and overload * Upper and lower threshold value can be adjusted separately * 1 changeover contact each for undershoot/overshoot * 1 yellow LED each for indicating undervoltage or overvoltage * 1 green LED each for indicating the applied control supply voltage * Flashes with 1 Hz during the operating time T1 and T2 * Flashes with 2 Hz if p.f.min p.f.max Measuring range Ue Rated control DT Screw-type connection supply voltage Us AC 50/60 Hz AC 50/60 Hz p.f. V Order No. PU PS* (UNIT, SET, M) PG Weight per PU approx. Price per PU kg Phase conductor voltage 0.1 ... 0.99 3x 230 3x 400 3x 480 3x 575 B } B B 3UG30 14-1BL60 3UG30 14-1BP60 3UG30 14-1BR60 3UG30 14-1BS60 1 1 1 1 1 unit 1 unit 1 unit 1 unit 101 101 101 101 0.311 0.308 0.355 0.350 7 Measuring-circuit voltage = control supply voltage * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/49 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Insulation monitoring for ungrounded AC networks Overview Application Relay for monitoring the insulation resistance between the ungrounded single or three-phase AC supply and a protective ground conductor * Measuring principle with superimposed DC voltage * Two selectable measuring ranges of 1 ... 110 kW * Stepless setting within the measuring range * Selectable: - Auto reset function with fixed hysteresis or - Storage of the tripping operation * Test function with test button and terminal connections on the front * Switching output: 1 CO contact * Insulation fault indication with a red LED * Supply voltage indication with a green LED * Electro-magnetically compatible according to EN 50081 and EN 61000-6-2. The 3UG30 81 monitoring relay is suitable for insulation monitoring of AC systems with one or three phases in ungrounded networks (IT networks). Supply voltage The 3UG30 81-1AK20 has alternative voltage terminals. Only one supply voltage is permitted to be connected to it! Terminals A1 and A2 are used to connect 230 V AC and terminals A1 and B2 are used to connect 115 V AC. The 3UG30 81-1AW30 has a wide-range input of 24 V to 240 V AC/DC on terminals A1 and A2. Selection and ordering data Measuring range Ue Rated control supply voltage Us kW V DT PU PS* (UNIT, SET, M) Screw-type connection Order No. PG Weight per PU approx. Price per PU kg Insulation monitors for ungrounded AC networks 10 ... 110 10 ... 110 AC 115 / 230 AC/DC 24 ... 240 A B 3UG30 81-1AK20 3UG30 81-1AW30 1 1 1 unit 1 unit 101 101 0.327 0.242 D 3UG32 08-1A 1 1 unit 101 0.010 Accessories 7 Sealable, transparent covers * You can order this quantity or a multiple thereof. 7/50 Siemens LV 1 * 2006 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Insulation monitoring for ungrounded DC networks Overview Application Relay for monitoring the insulation resistance between ungrounded purely DC networks and a protective-ground conductor * Measuring principle for differential current measurement * Response threshold can be set continuously from 10 to 110 kW * Selectable - Auto reset function with hysteresis or - Storage of the tripping operation * Front selector switch for open-circuit and closed-circuit principle for the output relay * Test function with test buttons on the front for L+ and Land over terminal connections * Switching output: 1 CO contact * Insulation fault indicator for L+ and L- through two red LEDs * Supply voltage indication with a green LED * Electro-magnetically compatible according to EN 50081 and EN 61000-6-2. The 3UG30 82 monitoring relay has been designed for insulation monitoring in ungrounded, purely DC networks with or without filtering. It is mainly used to monitor ungrounded DC voltage networks as well as to monitor battery-powered systems. Supply voltage Due to the electrical insulation of the supply voltage and the measurement circuit, the relay can be used for DC networks in which the auxiliary voltage is either supplied externally or where the network to be monitored also serves as the power supply. Note: If the monitoring relay is supplied with an AC 230 V voltage, for example, the terminals A1 and L+ as well as A2 and L- must not be connected with each other! Selection and ordering data Measuring range Ue Rated control supply voltage Us kW V DT PU PS* (UNIT, SET, M) Screw-type connection Order No. PG Weight per PU approx. Price per PU kg Insulation monitors for ungrounded DC networks 10 ... 110 AC/DC 24 ... 240 B 3UG30 82-1AW30 1 1 unit 101 0.233 D 3UG32 08-1A 1 1 unit 101 0.010 Accessories 7 Sealable, transparent covers * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/51 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Level monitoring Overview Application The 3UG35 01 level monitoring relay is used together with the 2- or 3-pole sensors to monitor the levels of conductive liquids. Selection and ordering data Standard mounting rail fixing Width 22.5 mm Level monitoring relay for conductive liquids Version Sensitivity Rated control supply voltage Us AC 50/60 Hz AC 50/60 Hz kW V Single-point and two-point level monitoring Overflow protection Dry running protection Leak monitoring * * * * * Inlet or outlet monitoring adjustable Sensitivity adjustment by potentiometer 1 yellow LED for indicating the relay state 1 green LED for indicating the applied control supply voltage 1 CO contact DT Order No. 24 120 230 } } } PU PS* (UNIT, SET, M) Screw-type connection PG Weight per PU approx. Price per PU 3UG35 01-1AC20 3UG35 01-1AG20 3UG35 01-1AL20 kg 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.143 0.142 0.139 7 Inlet or outlet 5 ... 100 monitoring (UNDER/OVER function) with switch, adjustable * * * * * You can order this quantity or a multiple thereof. 7/52 Siemens LV 1 * 2006 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Level monitoring Sensors for level monitoring Version Assignment Application DT Order No. Cable Electrode Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg Three-pole wire brown center electrode, elec500 mm long, with trode PTFE insulation white not screw-in green assigngland width A/F 22, able 3/8 inch thread, PVC connecting lead, 3 x 0.5 mm2, 2 m long, max. operating temperature 90 C, max. operating pressure 10 bar The electrodes can } be cut or bent to the required length before or after installation. The PTFE insulation must be removed over a length of approx. 5 mm. Application: For 2-point liquid level control in an insulating tank. One electrode each for the min. and max. value and a common reference electrode. 3UG32 07-3A 1 1 unit 101 0.254 Two-pole wire brown not electrode, 500 mm white assignlong, with PTFE able insulation, screw-in gland width A/F 22, 3/8 inch thread, PVC connecting lead, 3 x 0.5 mm2, 2 m long, max. operating temperature 90 C, max. operating pressure 10 bar For installation see 3UG32 07-3A } 3UG32 07-2A 1 1 unit 101 0.230 Two-pole bow brown gland electrode, 500 mm white not long, with PTFE green assiginsulation, nable screw-in gland width A/F 22, 3/8 inch thread, PVC connecting lead, 3 x 0.5 mm2, 2 m long, max. operating temperature 90 C, max. operating pressure 10 bar Thanks to the small } space requirements due to lateral fitting, ideal for use in small containers and pipes, as a leak monitor and level monitor or for warning of water entering an enclosure. 3UG32 07-2B 1 1 unit 101 0.128 Single-pole bow brown gland electrode for lateral white elecfitting, screw-in trode gland width A/F 22, 3/8 inch thread, PVC connecting lead, 3 x 0.5 mm2, 2 m long, max. operating temperature 90 C, max. operating pressure 10 bar As a max. value } electrode for lateral fitting or for alarm indication in conductive tanks or pipes. 3UG32 07-1B 1 1 unit 101 0.122 Single-pole bow brown gland electrode for lateral white elecfitting, 500 mm long, trode with PTFE insulation (PTFE), screw-in gland width A/F 22, 3/8 inch thread, PVC connecting lead, 3 x 0.5 mm2, 2 m long, max. operating temperature 90 C, max. operating pressure 10 bar For high flow C velocities or for alarm indication in conductive tanks or pipes. 3UG32 07-1C 1 1 unit 101 0.144 7 Application: For alarm indication in the event of overflow or low level and for 2-step liquid-level control, when the conductive tank is used as the reference electrode. * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/53 Monitoring Relays 3UG Monitoring Relays for Electrical and Additional Measurements Speed monitoring Overview Application The 3UG30 51 monitoring relay is used together with a sensor to monitor drives for underspeeding. * Slip or tear of a belt drive * Standstill monitoring (no protection of persons) * Transport monitoring for completeness Selection and ordering data Mounting onto standard mounting rail and screw fixing Width 45 mm Underspeed monitoring relay Version Measuring range * 4 measuring ranges adjustable on front panel * 1 green LED for indicating the applied control supply voltage * 1 yellow LED for indicating the relay state, flashes during the operating time T * 1 CO contact Rated control supply DT voltage Us Screw-type connection AC 50/60 Hz DC Revolutions min-1 Measuring range with or without memory, start-up override 0.3 ... 30 s, electrical isolation AC: Yes DC: No 0.1 ... 600 (4 ranges) Order No. ---241) } } } } PS* PG Weight per PU approx. Price per PU V 24 120 230 -- PU (UNIT, SET, M) 3UG30 51-1AC20 3UG30 51-1AG20 3UG30 51-1AL20 3UG30 51-1AC40 kg 1 1 1 1 1 unit 1 unit 1 unit 1 unit 101 101 101 101 0.273 0.274 0.272 0.161 7 1) The rated control supply voltage and the measuring circuit are not electrically isolated * You can order this quantity or a multiple thereof. 7/54 Siemens LV 1 * 2006 Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, analog adjustable The 3RS10/3RS11 analog temperature monitoring relays can be used for measuring temperatures in solid, liquid and gas media. The temperature is sensed by the sensors in the medium, evaluated by the device and monitored for overshoot or undershoot. When the threshold values are reached, the output relay switches on or off depending on the setting. Benefits * All devices are available alternatively with spring-loaded terminals * All devices except for 24 V AC/DC feature electrical isolation * Extremely easy operation using a rotary potentiometer * Variable hysteresis * Adjustable working principle for devices with 2 thresholds. Application The analog adjustable 3RS10 and 3RS11 SIMIREL temperature monitoring relays can be used in almost any application in which temperature overshoot or undershoot is not permitted, e.g. in the monitoring of set temperature limits and the output of alarm messages for: * Motor and plant protection * Switchgear cabinet temperature monitoring * Freeze monitoring * Temperature limits for process variables, e.g. in the packaging industry or electroplating * Controlling equipment and machines such as heating, climate and ventilation systems, solar collectors, heat pumps or warm water supplies * Bearing and gear oil monitoring * Monitoring of coolants 7 Overview Siemens LV 1 * 2006 7/55 Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, analog adjustable Selection and ordering data Analog adjustable evaluation units with one and two threshold values For analog adjustable units, the threshold values and the hysteresis of 2 to 20 % are set using a rotary potentiometer. For units with 2 threshold values, the adjustable hysteresis only Sensor Function Measuring range Rated control supply voltage Us AC 50-60 Hz applies to threshold value 1. For the second threshold value, a fixed hysteresis of 5 % applies. The product range has been developed for applications where a setting accuracy of 5 % is sufficient. DT Screw-type connection Order No. C PU (UNIT, SET, M) PS* PG Weight per PU approx. Price per PU kg V Analog adjustable, 1 threshold value, width 22.5 mm; closed-circuit principle; without memory; 1 NO + 1 NC PT100 (resistance sensor) AC/DC 24 AC 110 / 230 B B 3RS10 00-1CD00 3RS10 00-1CK00 1 1 1 unit 1 unit 101 101 0.150 0.190 0 ... + 100 AC/DC 24 AC 110 / 230 B A 3RS10 00-1CD10 3RS10 00-1CK10 1 1 1 unit 1 unit 101 101 0.145 0.189 0 ... + 200 AC/DC 24 AC 110 / 230 B A 3RS10 00-1CD20 3RS10 00-1CK20 1 1 1 unit 1 unit 101 101 0.145 0.186 - 50 ... + 50 AC/DC 24 AC 110 / 230 B B 3RS10 10-1CD00 3RS10 10-1CK00 1 1 1 unit 1 unit 101 101 0.150 0.186 0 ... + 100 AC/DC 24 AC 110 / 230 B B 3RS10 10-1CD10 3RS10 10-1CK10 1 1 1 unit 1 unit 101 101 0.150 0.190 0 ... + 200 AC/DC 24 AC 110 / 230 B B 3RS10 10-1CD20 3RS10 10-1CK20 1 1 1 unit 1 unit 101 101 0.150 0.191 Type J Overshoot 0 ... + 200 (thermocouple) 0 ... + 600 AC/DC 24 AC 110 / 230 B B 3RS11 00-1CD20 3RS11 00-1CK20 1 1 1 unit 1 unit 101 101 0.150 0.190 AC/DC 24 AC 110 / 230 B B 3RS11 00-1CD30 3RS11 00-1CK30 1 1 1 unit 1 unit 101 101 0.149 0.190 Type K Overshoot 0 ... + 200 (thermocouple) 0 ... + 600 AC/DC 24 AC 110 / 230 B B 3RS11 01-1CD20 3RS11 01-1CK20 1 1 1 unit 1 unit 101 101 0.150 0.190 AC/DC 24 AC 110 / 230 B B 3RS11 01-1CD30 3RS11 01-1CK30 1 1 1 unit 1 unit 101 101 0.150 0.190 AC/DC 24 AC 110 / 230 B B 3RS11 01-1CD40 3RS11 01-1CK40 1 1 1 unit 1 unit 101 101 0.150 0.190 AC/DC 24 AC/DC 24 ... 240 B B 3RS10 20-1DD00 3RS10 20-1DW00 1 1 1 unit 1 unit 101 101 0.166 0.175 0 ... + 100 AC/DC 24 AC/DC 24 ... 240 B B 3RS10 20-1DD10 3RS10 20-1DW10 1 1 1 unit 1 unit 101 101 0.164 0.175 0 ... + 200 AC/DC 24 AC/DC 24 ... 240 B B 3RS10 20-1DD20 3RS10 20-1DW20 1 1 1 unit 1 unit 101 101 0.166 0.175 -50 ... + 50 AC/DC 24 AC//DC 24 ... 240 B B 3RS10 30-1DD00 3RS10 30-1DW00 1 1 1 unit 1 unit 101 101 0.165 0.174 0 ... + 100 AC/DC 24 AC/DC 24 ... 240 B B 3RS10 30-1DD10 3RS10 30-1DW10 1 1 1 unit 1 unit 101 101 0.166 0.175 0 ... + 200 AC/DC 24 AC/DC 24 ... 240 B B 3RS10 30-1DD20 3RS10 30-1DW20 1 1 1 unit 1 unit 101 101 0.163 0.173 Type J Overshoot 0 ... + 200 (thermocouple) 0 ... + 600 AC/DC 24 AC/DC 24 ... 240 B B 3RS11 20-1DD20 3RS11 20-1DW20 1 1 1 unit 1 unit 101 101 0.165 0.175 AC/DC 24 AC/DC 24 ... 240 B B 3RS11 20-1DD30 3RS11 20-1DW30 1 1 1 unit 1 unit 101 101 0.167 0.175 Overshoot - 50 ... + 50 Undershoot 3RS10 00-1CD10 + 500 ... + 1.000 Analog adjustable for warning and tripping (2 threshold values), width 22.5 mm; open/closed-circuit principle switchable; without memory; 1 NO + 1 CO 7 PT100 (resistance sensor) Overshoot - 50 ... + 50 Undershoot 3RS11 21-1DD40 Type K Overshoot 0 ... + 200 (thermo0 ... + 600 couple) + 500 ... + 1.000 AC/DC 24 ... 240 B 3RS11 21-1DW20 1 1 unit 101 0.179 AC/DC 24 ... 240 B 3RS11 21-1DW30 1 1 unit 101 0.176 AC/DC 24 B 3RS11 21-1DD40 1 1 unit 101 0.167 * You can order this quantity or a multiple thereof. 7/56 Siemens LV 1 * 2006 Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, analog adjustable Analog adjustable evaluation units with one and two threshold values For analog adjustable units, the threshold values and the hysteresis of 2 to 20 % are set using a rotary potentiometer. For units with 2 threshold values, the adjustable hysteresis only applies to threshold value 1. Sensor Function Measuring range For the second threshold value, a fixed hysteresis of 5 % applies. The product range has been developed for applications where a setting accuracy of 5 % is sufficient. Rated control supply DT voltage Us AC 50-60 Hz Spring-loaded terminal Order No. C PU (UNIT, SET, M) PS* PG Weight per PU approx. Price per PU kg V Analog adjustable, 1 threshold value, width 22.5 mm; closed-circuit principle; without memory; 1 NO + 1 NC PT100 (resistance sensor) Type J (thermocouple) Overshoot Overshoot - 50 ... + 50 AC/DC 24 AC 110 / 230 B B 3RS10 00-2CD00 3RS10 00-2CK00 1 1 1 unit 1 unit 101 101 0.125 0.163 0 ... + 100 AC/DC 24 AC 110 / 230 B B 3RS10 00-2CD10 3RS10 00-2CK10 1 1 1 unit 1 unit 101 101 0.125 0.165 0 ... + 200 AC/DC 24 AC 110 / 230 B B 3RS10 00-2CD20 3RS10 00-2CK20 1 1 1 unit 1 unit 101 101 0.121 0.165 0 ... + 200 AC/DC 24 B 3RS11 00-2CD20 1 1 unit 101 0.125 Analog adjustable for warning and tripping (2 threshold values), width 22.5 mm; open/closed-circuit principle switchable; without memory; 1 NO + 1 CO PT100 (resistance sensor) Type J (thermocouple) AC/DC 24 ... 240 B 3RS10 20-2DW20 1 1 unit 101 0.153 Undershoot 0 ... + 200 AC/DC 24 B 3RS10 30-2DD20 1 1 unit 101 0.145 Overshoot AC/DC 24 B 3RS11 20-2DD20 1 1 unit 101 0.140 Overshoot 0 ... + 200 0 ... + 200 Accessories Version DT Order No. Blank labeling plates, 20 mm x 7 mm, pastel turquoise1) C Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg 3RT19 00-1SB20 100 340 units 101 22.000 Matching sensors can be found at http://www.siemens.com/temperature 7 1) Computer labeling system for individual labeling of device labeling plates available from: murrplastik Systemtechnik GmbH. * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/57 Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, digitally adjustable to DIN 3440 Overview The short-circuit and open-circuit detection as well as the measuring range is limited, depending on the sensor type. The 3RS10/3RS11 temperature monitoring relays can be used for measuring temperatures in solid, liquid and gas media. The temperature is sensed by the sensor in the medium, evaluated by the device and monitored for overshoot or undershoot or for staying within an operating range (window function). The 3RS10 40, 3RS20 40, 3RS11 40 and 3RS21 40 relays comply with the requirements of DIN 3440 as temperature monitors; the 3RS10 42 and 3RS11 42 relays comply with the requirements of DIN 3440 as temperature limiters. The relays are also an excellent alternative to temperature controls in the low-end performance range (2 or 3-point closed-loop control). Benefits * Very simple operation without complicated menu selections * Certification to DIN 3440 * All devices are available alternatively with spring-loaded terminals * 2 or 3-point closed-loop control can be configured quickly Application 7 The 3RS10 40, 3RS10 42, 3RS11 40, 3RS11 42, 3RS20 40 and 3RS21 40 temperature monitoring relays can be used in almost any application in which temperature overshoot or undershoot is not permitted, e.g. in the monitoring of set temperature limits and the output of alarm messages for: * Plant and environment protection * Temperature limits for process variables e.g. in the packaging industry or electroplating * Temperature limits for district heating plants * Exhaust temperature monitoring * Controlling equipment and machines such as heating, climate and ventilation systems, solar collectors, heat pumps or warm water supplies * Motor, bearing and gear oil monitoring * Monitoring of coolants 7/58 Siemens LV 1 * 2006 Measuring range in C for thermocouples Sensor type Short-circuit Wire break 3RS11 40 3RS11 42 Measuring range Measuring range in C in C J -- x -99 ... +999 -99 ... +1200 K -- x -99 ... +999 -99 ... +1350 T -- x -99 ... +400 -99 ... +400 E -- x -99 ... +999 -99 ... +999 N -- x -99 ... +999 -99 ... +999 S -- x -- R -- x -- 0 ... 1750 B -- x -- 400 ... 1800 0 ... 1750 Measuring range in C for resistance sensors Sensor type Short-circuit Wire break 3RS10 40/41 3RS10 42 Measuring range Measuring range in C in C PT100 x x -50 ... +500 -50 ... +750 PT1000 x x -50 ... +500 -50 ... +500 KTY 83-110 x x -50 ... +175 -50 ... +175 KTY 84 x x -40 ... +300 -40 ... +300 NTC1) x -- 80 ... 160 80 ... 160 1) Not for NTC B57227-K333-A1 (100 C: 1.8 kW; 25 C: 32.762 kW). Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, digitally adjustable to DIN 3440 Selection and ordering data Digitally adjustable evaluation units according to DIN 3440 Temperature monitoring relays are very easy to operate. The three-digit LED display always shows the current temperature. A separate relay with an NO contact is included for sensor monitoring. The relay is switched off in parameterization mode. The following parameters can be adjusted: * Sensor type * 2 threshold values, J1, J2 * 1 hysteresis; applies to both thresholds (0 ... 99 K) * 1 delay time; applies to both thresholds (0 ... 999 s) * Open/closed-circuit principle switchable * Manual/remote RESET * Function: Overshoot or undershoot or window monitoring Wide-range voltage versions are electrically isolated. The temperature ranges depend on the sensor type. Sensor Measuring range Rated control DT (measuring range supply voltage Us limit depends on AC 50-60 Hz the sensor) PU PS* (UNIT, SET, M) Screw-type connection Order No. PG Weight per PU approx. Price per PU kg V "Temperature monitors" according to DIN 3440, digitally adjustable, 2 threshold values, width 45 mm; 1 CO + 1 CO + 1 NO, memory function possible with external jumper. Device parameters are non-volatile PT100/1000; KTY83/84; NTC (resistance sensors)1) TYPE J, K, T, E, N (thermocouple) - 50 ... + 500 C AC/DC 24 A AC/DC 24 ... 240 A 3RS10 40-1GD50 3RS10 40-1GW50 1 1 1 unit 1 unit 101 101 0.317 0.329 - 50 ... + 932 F AC/DC 24 B AC/DC 24 ... 240 B 3RS20 40-1GD50 3RS20 40-1GW50 1 1 1 unit 1 unit 101 101 0.189 0.186 - 99 ... + 999 C AC/DC 24 A AC/DC 24 ... 240 B 3RS11 40-1GD60 3RS11 40-1GW60 1 1 1 unit 1 unit 101 101 0.318 0.329 - 99 ... + 1830 F AC/DC 24 B AC/DC 24 ... 240 B 3RS21 40-1GD60 3RS21 40-1GW60 1 1 1 unit 1 unit 101 101 0.317 0.317 3RS10 40-1GD50 "Temperature limiters" and "Temperature monitors" according to DIN 3440, digitally adjustable, 2 threshold values, width 45 mm; 1 CO + 1 CO + 1 NO, tripping state and device parameters are non-volatile PT100/1000; KTY83/84; NTC (resistance sensors)1) - 50 ... + 750 C AC/DC 24 B AC/DC 24 ... 240 B 3RS10 42-1GD70 3RS10 42-1GW70 1 1 1 unit 1 unit 101 101 0.317 0.331 TYPE J, K, T, E, N, R, S, B (thermocouple) - 99 ... +1.800 C AC/DC 24 B AC/DC 24 ... 240 B 3RS11 42-1GD80 3RS11 42-1GW80 1 1 1 unit 1 unit 101 101 0.318 0.329 7 1) NTC type: B57227-K333-A1 (100 C: 1.8 kW; 25 C: 32.762 kW). * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/59 Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, digitally adjustable to DIN 3440 Digitally adjustable evaluation units according to DIN 3440 Temperature monitoring relays are very easy to operate. The three-digit LED display always shows the current temperature. A separate relay with an NO contact is included for sensor monitoring. The relay is switched off in parameterization mode. The following parameters can be adjusted: * Sensor type * 2 threshold values, J1, J2 * 1 hysteresis; applies to both thresholds (0 ... 99 K) * 1 delay time; applies to both thresholds (0 ... 99 s) * Open/closed-circuit principle switchable * Manual/remote RESET * Function: Overshoot or undershoot or window monitoring Wide-range voltage versions are electrically isolated. The temperature ranges depend on the sensor type. . Sensor Measuring range Rated control (measuring range supply voltage Us limit depends on AC 50-60 Hz the sensor) DT PU PS* (UNIT, SET, M) Spring-loaded terminal Order No. PG Weight per PU approx. Price per PU kg V "Temperature monitors" acc. to DIN 3440, digitally adjustable, 2 threshold values, width 45 mm; 1 CO + 1 CO + 1 NO, memory function possible with external jumper. Device parameters are non-volatile PT100/1000; KTY83/84; - 50 ... + 500 C NTC (resistance sensors)1) - 50 ... + 932 F AC/DC 24 AC/DC 24 ... 240 B B 3RS10 40-2GD50 3RS10 40-2GW50 1 1 1 unit 1 unit 101 101 0.267 0.281 AC/DC 24 AC/DC 24 ... 240 C C 3RS20 40-2GD50 3RS20 40-2GW50 1 1 1 unit 1 unit 101 101 0.100 0.100 TYPE J, K, T, E, N (thermocouple) - 99 ... + 999 C AC/DC 24 AC/DC 24 ... 240 B B 3RS11 40-2GD60 3RS11 40-2GW60 1 1 1 unit 1 unit 101 101 0.269 0.300 - 99 ... + 1830 F AC/DC 24 AC/DC 24 ... 240 C C 3RS21 40-2GD60 3RS21 40-2GW60 1 1 1 unit 1 unit 101 101 0.100 0.100 "Temperature limiters" and "Temperature monitors" acc. to DIN 3440, digitally adjustable, 2 threshold values, width 45 mm; 1 CO + 1 CO + 1 NO, tripping state and device parameters are non-volatile PT100/1000; KTY83/84; -50 ... +750 C NTC (resistance sensors)1) AC/DC 24 AC/DC 24 ... 240 C C 3RS10 42-2GD70 3RS10 42-2GW70 1 1 1 unit 1 unit 101 101 0.267 0.281 TYPE J, K, T, E, N, R, S, B (thermocouple) AC/DC 24 AC/DC 24 ... 240 C C 3RS11 42-2GD80 3RS11 42-2GW80 1 1 1 unit 1 unit 101 101 0.269 0.300 -99 ... +1.800 C 1) NTC type: B57227-K333-A1 (100 C: 1.8 kW; 25 C: 32.762 kW). Accessories Language used for labels DT Order No. Price per PU 7 Design PU PS* (UNIT, SET, M) PG Weight per PU approx. kg Push-in lugs for screw mounting for each thermistor motor 3RN1 protection device, 2 units are required. 1 package contains 10 units for 5 devices } 3RP19 03 1 10 units 101 0.002 B B 3RS19 01-1A 3RS19 01-1C 1 1 5 units 5 units 101 101 0.005 0.005 C 3RT19 00-1SB20 100 340 units 101 22.000 Replaceable cover labels for digital devices Devices acc. to DIN 3440 German Matching sensors can be found English on the Internet at www.siemens.com/temperature Blank labeling plates 20 mm x 7 mm, pastel turquoise1) Matching sensors can be found at http://www.siemens.com/temperature 1) Computer labeling system for individual labeling of device labeling plates available from: murrplastik Systemtechnik GmbH. * You can order this quantity or a multiple thereof. 7/60 Siemens LV 1 * 2006 Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, digitally adjustable for up to 3 sensors The 3RS10 41 temperature monitoring relays can be used for measuring temperatures in solid, liquid and gas media. The temperature is sensed by the sensor in the medium, evaluated by the device and monitored for overshoot or undershoot or for staying within an operating range (window function). The signal evaluator can evaluate up to 3 resistance sensors at the same time and is specially designed for monitoring motor windings and bearings. Benefits * Very simple operation without complicated menu selections * Space-saving with 45 mm width * All devices are available alternatively with spring-loaded terminals * 2 or 3-point closed-loop control can be configured quickly Application The 3RS10 41 temperature monitoring relays can be used in almost any application in which several temperatures have to be monitored simultaneously for overshoot or undershoot or within a range. Monitoring of set temperature limits and output of alarm messages for: * Plant and environment protection * Temperature limits for process variables e.g. in the packaging industry or electroplating * Controlling equipment and machines such as heating, climate and ventilation systems, solar collectors, heat pumps or warm water supplies * Motor, bearing and gear oil monitoring * Monitoring of coolants The short-circuit and open-circuit detection as well as the measuring range is limited, depending on the sensor type. Measuring range in C for resistance sensors Sensor type Open-circuit Short-circuit Measuring range in C PT100 x x -50 ... +500 PT1000 x x -50 ... +500 KTY 83-110 x x -50 ... +175 KTY 84 x x -40 ... +300 NTC -- x +80 ... +160 7 Overview Siemens LV 1 * 2006 7/61 Monitoring Relays 3RS10, 3RS11 Temperature Monitoring Relays Relays, digitally adjustable for up to 3 sensors Selection and ordering data Digitally adjustable signal evaluators The digitally adjustable temperature monitoring relays are very simple to operate. The three-digit LED display always shows the current temperature. A separate relay with an NO contact is included for sensor monitoring. The relay is switched off in parameterization mode. The following parameters can be adjusted: * Sensor type * 2 threshold values, J1, J2 * 1 hysteresis; applies to both thresholds (0 ... 99 K) * 1 delay time; applies to both thresholds (0 ... 999 s) * Open/closed-circuit principle * Function: Overshoot or undershoot or window monitoring Wide-range voltage versions are electrically isolated. The temperature ranges depend on the sensor type. Sensor Number of sensors Measuring range Rated control supply voltage Us DT Order No. C PU PS* (UNIT, SET, M) Screw-type connection PG Weight per PU approx. Price per PU kg V Motor monitoring relays, digitally adjustable for up to 3 sensors, width 45 mm; 1 CO + 1 CO + 1 NO PT100/1000; 1 to 3 sensors KTY83/84; NTC (resistance sensors)1) -50 ... +500 AC/DC 24 ...240 V A 3RS10 41-1GW50 1 DT Spring-loaded terminal 1 unit 101 0.333 3RS10 41-1GW50 1) NTC type: B57227-K333-A1 (100 C: 1.8 kW; 25 C: 32.762 kW). Sensor Number of sensors Measuring range Rated control supply voltage Us Order No. C PU PS* (UNIT, SET, M) PG Weight per PU approx. Price per PU kg V Motor monitoring relays, digitally adjustable for up to 3 sensors, width 45 mm; 1 CO + 1 CO + 1 NO 7 PT100/1000; 1 to 3 KTY83/84; sensors NTC (resistance sensors)1) -50 ... +500 AC/DC 24 ...240 V B 3RS10 41-2GW50 DT Order No. 1 1 unit 101 0.283 1) NTC type: B57227-K333-A1 (100 C: 1.8 kW; 25 C: 32.762 kW). Accessories Design Language used for labels Price per PU PU PS* (UNIT, SET, M) PG Weight per PU approx. kg Push-in lugs for screw mounting for each thermistor motor protection device, 2 units are required. 1 package contains 10 units for 5 devices 3RN1 } 3RP19 03 1 10 units 101 0.002 German English B B 3RS19 01-1B 3RS19 01-1D 1 1 5 units 5 units 101 101 0.005 0.001 C 3RT19 00-1SB20 100 340 units 101 22.000 Replaceable cover labels for digital devices Devices acc. to DIN 3440 Blank labeling plates 20 mm x 7 mm, pastel turquoise1) 1) Computer labeling system for individual labeling of device labeling plates available from: murrplastik Systemtechnik GmbH. * You can order this quantity or a multiple thereof. 7/62 Siemens LV 1 * 2006 Monitoring Relays 3RN1 Thermistor Motor Protection For PTC sensors Thermistor motor protection devices are used for direct monitoring of the motor winding temperature. For this purpose, the motors are equipped with temperature-dependent resistors (PTC) that are directly installed in the motor winding and abruptly change their resistance at their limit temperature. Benefits * Thanks to direct motor protection, overdimensioning of the motors is not necessary. * No additional overload protection equipment is necessary. * No settings on the device are necessary. * Electronically optimized output thanks to variants with goldplated contacts. * Rapid error diagnosis thanks to variants that indicate openand short-circuit in the sensor circuit. * Screw-type or spring-loaded terminals. Application Direct motor protection through temperature monitoring of the motor winding offers 100 % motor protection even under the most difficult ambient conditions, without the need to make adjustments on the device. Versions with gold-plated contacts ensure, in addition, a high switching reliability that is even higher than an electronic control: * At increased ambient temperatures * For high switching cycle frequency * For long start-up and braking procedures * Used together with frequency converters (low speeds) 7 Overview Siemens LV 1 * 2006 7/63 Monitoring Relays 3RN1 Thermistor Motor Protection For PTC sensors Selection and ordering data Thermistor motor protection relays for PTC thermistors (Type A PTCs) * Monostable version with closed-circuit principle, triggers in the event of control supply voltage failure RESET Contacts Rated control supply voltage Us 50/60 Hz * PTB01 ATEX approval, see Catalog LV 1 T. * 3RN10 13-.BW01: bistable version, does not trigger in the event of control supply voltage failure * All units except for 24 V AC/DC feature electrical isolation DT Screw-type connection Order No. PU (UNIT, SET, M) PS* PG Weight per PU approx. Price per PU kg V Compact signal evaluation units, width 22.5 mm, 1 LED Terminal A1 is jumpered with the root of the changeover contact Auto 1 CO AC/DC 24 AC 110 AC 230 A A A 3RN10 00-1AB00 3RN10 00-1AG00 3RN10 00-1AM00 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.114 0.157 0.156 Standard evaluation units, width 22.5 mm, 2 LEDs Auto 3RN10 13-1BB00 1 NO + 1 NC AC/DC 24 AC 110 AC 230 AC/DC 24 ... 240 A A A A 3RN10 10-1CB00 3RN10 10-1CG00 3RN10 10-1CM00 3RN10 10-1CW00 1 1 1 1 1 unit 1 unit 1 unit 1 unit 101 101 101 101 0.134 0.174 0.175 0.146 2 CO AC/DC 24 AC 110 DC 230 A A A 3RN10 10-1BB00 3RN10 10-1BG00 3RN10 10-1BM00 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.162 0.213 0.213 2 CO, gold-plated AC/DC 24 B 3RN10 10-1GB00 1 1 unit 101 0.154 1 NO + 1 NC AC/DC 24 AC 110 / 230 } } 3RN10 11-1CB00 3RN10 11-1CK00 1 1 unit 101 0.147 1 1 unit 101 0.188 Short-circuit detection for sensor circuit Manual/ 2 CO AC/DC 24 remote1) AC 110 AC 230 A B A 3RN10 11-1BB00 3RN10 11-1BG00 3RN10 11-1BM00 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.163 0.214 0.212 2 CO, gold-plated AC/DC 24 B 3RN10 11-1GB00 1 1 unit 101 0.165 AC/DC 24 AC 110 / 230 } } 3RN10 12-1CB00 3RN10 12-1CK00 1 1 1 unit 1 unit 101 101 0.148 0.188 B B A 3RN10 12-1BB00 3RN10 12-1BG00 3RN10 12-1BM00 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.164 0.214 0.216 B 3RN10 12-1GB00 1 1 unit 101 0.155 } } 3RN10 13-1BB00 3RN10 13-1BW10 1 1 1 unit 1 unit 101 101 0.160 0.172 B 3RN10 13-1GW10 1 1 unit 101 0.168 } 3RN10 22-1DW00 1 1 unit 101 0.173 } 3RN10 62-1CW00 1 1 unit 101 0.296 A 3RN10 13-1BW01 1 1 unit 101 0.169 Manual/ remote1) Non-volatile2) 3RN10 13-1BW01 Manual/ 1 NO + 1 NC Auto/ Remote Non-volatile2), short-circuit detection in sensor circuit Manual/ 2 CO AC/DC 24 Auto/ AC 110 Remote AC 230 2 CO, gold-plated AC/DC 24 7 Non-volatile2); short-circuit and open-circuit detection and indication in sensor circuit; wide-range voltage with screw connection with safe isolation Manual/ 2 CO AC/DC 24 Auto/ AC/DC 24 ... 240 Remote 2 CO, gold-plated AC/DC 24 ... 240 Evaluation units for 2 sensor circuits, warning and switching off, width 22.5 mm, 3 LEDs Test/RESET button, non-volatile2) Manual/ 1 NO + 1 CO AC/DC 24 ... 240 Auto/ Remote Evaluation units for 6 sensor circuits, multiple motor protection, width 45 mm, 8 LEDs Test/RESET button, non-volatile2) Manual/ 1 NO + 1 NC AC/DC 24 ... 240 Auto/ Remote Bistable evaluation units, width 22.5 mm Test/ RESET button, non-volatile2) Short-circuit and open-circuit detection and indication in sensor circuit Manual/ 2 CO AC/DC 24 ... 240 Auto/ Remote 1) The unit can be reset with the RESET button or by disconnecting the control supply voltage. 2) For more information on protection against voltage failure, see Catalog LV 1 T. * You can order this quantity or a multiple thereof. 7/64 Siemens LV 1 * 2006 Monitoring Relays 3RN1 Thermistor Motor Protection For PTC sensors Thermistor motor protection relays for PTC thermistors (Type A PTCs) * Monostable version with closed-circuit principle, triggers in the event of control supply voltage failure RESET Contacts Rated control supply voltage Us 50/60 Hz * PTB01 ATEX approval, see Catalog LV 1 T. * 3RN10 13-.BW01: bistable version, does not trigger in the event of control supply voltage failure * All units except for 24 V AC/DC feature electrical isolation DT Spring-loaded terminal Order No. PU PS* (UNIT, SET, M) PG Weight per PU approx. Price per PU kg V Compact signal evaluation units, width 22.5 mm, 1 LED Terminal A1 is jumpered with the root of the changeover contact Auto 1 CO AC/DC 24 AC 110 AC 230 A B B 3RN10 00-2AB00 3RN10 00-2AG00 3RN10 00-2AM00 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.104 0.153 0.153 Auto 3RN10 12-2CK00 1) Manual/remote 1 NO + 1 NC AC/DC 24 AC 110 AC 230 AC/DC 24 ... 240 A B A A 3RN10 10-2CB00 3RN10 10-2CG00 3RN10 10-2CM00 3RN10 10-2CW00 1 1 1 1 1 unit 1 unit 1 unit 1 unit 101 101 101 101 0.116 0.153 0.159 0.127 2 CO AC/DC 24 AC 110 ... AC 230 C C C 3RN10 10-2BB00 3RN10 10-2BG00 3RN10 10-2BM00 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.137 0.139 0.190 2 CO, gold-plated AC/DC 24 C 3RN10 10-2GB00 1 1 unit 101 0.139 1 NO + 1 NC AC/DC 24 AC 110 / 230 } A 3RN10 11-2CB00 3RN10 11-2CK00 1 1 1 unit 1 unit 101 101 0.125 0.164 C C B 3RN10 11-2BB00 3RN10 11-2BG00 3RN10 11-2BM00 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.138 0.190 0.192 Short-circuit detection for sensor circuit Manual/remote1) 2 CO AC/DC 24 AC 110 AC 230 Non-volatile2) Manual/Auto/ Remote Non-volatile2), Manual/Auto/ Remote 2 CO, gold-plated AC/DC 24 C 3RN10 11-2GB00 1 1 unit 101 0.154 1 NO + 1 NC AC/DC 24 AC 110 / 230 A B 3RN10 12-2CB00 3RN10 12-2CK00 1 1 1 unit 1 unit 101 101 0.125 0.161 C C C 3RN10 12-2BB00 3RN10 12-2BG00 3RN10 12-2BM00 1 1 1 1 unit 1 unit 1 unit 101 101 101 0.130 0.130 0.181 C 3RN10 12-2GB00 1 1 unit 101 0.140 A } 3RN10 13-2BB00 3RN10 13-2BW00 1 1 1 unit 1 unit 101 101 0.140 0.151 C 3RN10 13-2GW00 1 1 unit 101 0.143 B 3RN10 22-2DW00 1 1 unit 101 0.147 B 3RN10 62-2CW00 1 1 unit 101 0.251 B 3RN10 13-2BW01 1 1 unit 101 0.139 short-circuit detection in sensor circuit 2 CO AC/DC 24 AC 110 AC 230 2 CO, gold-plated AC/DC 24 Non-volatile2); short-circuit and open-circuit detection and indication in sensor circuit; wide-range voltage with screw connection with safe isolation Manual/Auto/ 2 CO AC/DC 24 Remote AC/DC 24 ... 240 2 CO, gold-plated AC/DC 24 ... 240 Evaluation units for 2 sensor circuits, warning and switching off, width 22.5 mm, 3 LEDs Test/RESET button, non-volatile2) Manual/Auto/ 1 NO + 1 CO Remote AC/DC 24 ... 240 Evaluation units for 6 sensor circuits, multiple motor protection, width 45 mm, 8 LEDs Test/RESET button, non-volatile2) Manual/Auto/ 1 NO + 1 NC Remote AC/DC 24 ... 240 Bistable evaluation units, width 22.5 mm Test/ RESET button, non-volatile2) Short-circuit and open-circuit detection and indication in sensor circuit Manual/Auto/ 2 CO AC/DC 24 ... 240 Remote 1) The unit can be reset with the RESET button or by disconnecting the control supply voltage. 2) For more information on protection against voltage failure, see Catalog LV 1 T. * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/65 7 Standard evaluation units, width 22.5 mm, 2 LEDs Monitoring Relays 3RN1 Thermistor Motor Protection For PTC sensors Accessories Version For type DT Order No. Price per PU PU PS* (UNIT, SET, M) PG Weight per PU approx. kg Push-in lugs for screw mounting For each thermistor motor protection 3RN1 device, 2 units are required. 1 pack contains 10 units for 5 devices } 3RP19 03 Blank labeling plates, 20 mm x 7 mm, pastel turquoise1) C 3RT19 00-1SB20 1 10 units 101 0.002 100 340 units 101 22.000 Blank labeling plates 7 1) Computer labeling system for individual labeling of device labeling plates available from: murrplastik Systemtechnik GmbH. * You can order this quantity or a multiple thereof. 7/66 Siemens LV 1 * 2006 3TK28 Safety Relays General data Application Classification of a machine in categories acc. to EN 954-1 The 98/37/EG machinery directive stipulates that every machine must comply with the applicable guidelines and standards. Measures must be taken to keep the risk to persons as small as possible. The first step is for the project engineer to perform a risk evaluation according to EN 1050 "Guidelines for risk assessment". The ambient conditions of the machine have to be considered, for example. Then any overall risk must be evaluated. Risk evaluation must be performed in such a manner that the procedure and conclusions can be retraced. The dangers and possible technical measures for reducing risk must also be specified. After risk assessment, the category according to which the safety circuits will be designed and implemented is specified with the aid of EN 954-1. This category defines the technical requirements for the configuration of the safety equipment. There are five categories (B, 1, 2, 3 and 4), whereby B (for Basic category) is the category of the lowest risk and the one which defines the minimum demands made on the control system. Possible selection of the categories acc. to EN 954-1 Starting point for risk assessment of the safety related part of the control B Category 1 2 3 S Severity of the injury 4 S1 P1 F Frequency and/or duration of the exposure to danger P Possibility to avoid the danger S1 Minor (usually reversible) injury F1 From rarely to often and/or short duration of exposure P1 Possible under certain conditions S2 Serious (normally irreversible) injury including death F2 From frequently to constantly and/or long duration of exposure P2 Hardly possible F1 P2 P1 F2 P2 NSC0_00302 S2 Selection of the category B, 1 to 4: Categories for parts of controllers with relevance for safety Preferred categories for reference points Possible categories which demand additional measures Measures that may be excessive with respect to the particular risk Summary of the requirements for categories acc. to EN 954-1 Summary of requirements System response Principles for achieving safety B The safety related parts of controllers and/or their protective devices as well as their components must be designed, constructed, selected, assembled and combined in accordance with the applicable standards in such a way that they can resist the expected external influences. The occurrence of a fault can result in loss of the safety function. Mainly characterized by the selection of components 1 The requirements of B must be met. The occurrence of a fault can result in loss of the safety function but the probability of it occurring is less than for Category B. Well-proven components and well-proven safety principles must be implemented. 2 3 The requirements of B must be met and well-proven safety principles must be implemented. The safety functions must be tested at regular intervals by the machine control. The occurrence of a fault can result in loss of the safety function between tests. The requirements of B must be met and well-proven safety principles must be implemented. When the single fault occurs, the safety function is always maintained. Parts with relevance for safety must be implemented such that a single fault in any of these components does not result in loss of the safety function, and whenever reasonably possible, the individual fault is detected. 4 7 Category (not to be applied in any specific hierarchy) Mainly characterized by the structure The loss of the safety function will be detected by the test. Some but not all faults are detected. An accumulation of undetected faults may lead to loss of the safety function. The requirements of B must be met and well-proven safety principles must be implemented. When faults occur, the safety function is always maintained. Parts with relevance for safety must be implemented such that a single fault in any of these components does not result in loss of the safety function, and the individual fault is detected during or before the next activation of the safety function or, if this is not possible, an accumulation of faults will not result in loss of the safety function. The faults are detected early to prevent loss of the safety function. Siemens LV 1 * 2006 7/67 3TK28 Safety Relays General data Standards for "Safety of machines" 7 EN 60204-1 "Electrical equipment of industrial machines" 7 EN 418 "EMERGENCY-STOP equipment, functional aspects, basic design principles" 7 EN 574 "Two-hand switching" 7 EN 954-1 "Safety-related parts of controls" 7 EN 1050 "Guidelines for risk assessment" 7 EN 1088 "Locking facilities in combination with isolating protective devices" 7 IEC 61508 "Functional safety of electrical/programmable solid-state safety related systems" Stop categories Potential dangers posed by a machine must be eliminated as quickly as possible. As a rule, the "danger-free status" is standstill with respect to hazardous motions. All SIRIUS safety relays are de-energized in the event of danger or a fault, i.e. the machine drives are switched to standstill. The EN 60204 standard requires that every machine must be equipped with the Stop function of Category 0. Stop functions of Categories 1 and/or 2 must be implemented when this is necessary for the safety and/or functional requirements of the machine. There are 3 categories of Stop functions: Stop category 0: Shutdown by immediate switch-off of the energy infeed to the machine drives. 7 Stop category 1: Controlled shutdown, whereby the energy infeed to the machine drives is maintained during shutdown and is only switched off when standstill has been achieved. 7 Stop category 2: Controlled shutdown, whereby the energy infeed to the machine drives is maintained. 7 The devices support autostart or monitored start depending on their versions. Autostart/Manual start 7 Autostart: The device switches on the enabling circuits automatically as soon as the switch-on conditions (sensor and feedback circuits closed) are satisfied. Manual start: If an ON pushbutton is installed in the feedback circuit, a manual start can be provided with the autostart function. Caution: Not permissible for EMERGENCY-STOP Category 4! Monitored start To switch on the enabling circuits the switch-on conditions (sensor and feedback circuits closed) must be satisfied. In addition the device must be started with an ON pushbutton. The device responds in this case to the negative edge of the ON signal. 7/68 Siemens LV 1 * 2006 Crossover protection Crossover protection is the ability of the safety relay to detect faults (e.g. through cable compression or ground faults) in the safety chain to be monitored and to suppress the enabling of the enabling circuits until the external fault has been rectified. EMERGENCY-STOP EMERGENCY-STOP devices must have priority over all other functions. The energy infeed to the machine drives that can cause dangerous situations must be switched off as quickly as possible without causing any further danger. Resetting of the drives must not result in restarting of the equipment. EMERGENCY-STOP must either function as a Stop of Category 0 or Category 1. Resetting of the command device must only be possible as a result of a manual action on the command device. Resetting of the command device must not initiate a restart command. Restarting of the machine must not be possible until all actuated operator controls have been reset deliberately and individually by hand (EN 418). The basic units of the SIRIUS safety relays can be used for EMERGENCY-STOP applications up to Category 4 of EN 954-1. Category 3 or 4 of EN 954-1 or SIL 2/3 (Safety Integrity Level) acc. to IEC 61508 must be achieved depending on the external circuit and routing of the sensor leads. Protective door monitoring EN 1088 distinguishes between interlocked, isolating protection devices and interlocked, isolating protective devices with tumbler. SIRIUS safety relays are also used in this case for EMERGENCYSTOP applications. Control systems for up to Category 4 of EN 954-1 or SIL 2/3 of IEC 61508 are possible. Presses and punches The two-hand control unit is a device that requires both hands of the operator to be used simultaneously as a means of protecting the operator from danger. The devices are suitable for installation in control systems for eccentric, hydraulic and screw presses. They can be used up to Category 4 of EN 954-1. Type III C according to EN 574 is possible specifically for presses. 3TK28 Safety Relays with electronic enabling circuits Overview The SIRIUS safety pilot guides you quickly to the right device Type Connection 1-channel Crossover protection Solid-state sensors Cascade input Safety mats B 1 2 3 4 3TK28 40 basic unit -- -- -- -- 3TK28 41 standard unit 1 3TK28 42 standard unit tv 1 3TK28 45 multi-function unit 1 Type 2-channel Category acc. to EN 954-1 EMERGENCY- Protective STOP door Enabling circuit, Enabling floating circuit, solid-state STOP category 0 Signal- Autostart Monitored ing start circuit Stop Stop Stop catecate- category 1 gory 0 gory 1 24 V DC Switching capacity Rated operational Rated control voltage supply voltage AC -15 DC -13 DC AC AC DC at at 24 V 230 V 600 V 24 V U = 230 V U = 24 V Control inputs AC AC DC 115 V 230 V 24 V 3TK28 40 basic unit -- -- 21) -- -- -- 0.5 A -- -- -- -- -- 3TK28 41 standard unit -- -- 2 -- -- -- 1.5 A -- -- -- -- -- 3TK28 42 standard unit tv -- -- 1 1 -- -- 1.5 A -- -- -- -- -- 3TK28 45 multi-function unit 1 1 1 1 1 HL 2A 1.5 A -- -- -- -- 2 -- 2 -- 1 HL = available -- = not available 7 1) The outputs are only safe when an external contactor is used. Siemens LV 1 * 2006 7/69 3TK28 Safety Relays with electronic enabling circuits Selection and ordering data Rated control supply voltages Us 24 V DC and AC 50/60 Hz, 115, 230 V Enabling circuit, floating Enabling circuit, solid-state Signal- Achievable Rated control DT category supply ing voltage Us circuit acc. to EN 954-1 Order No. Stop Stop Stop Stop cate- cate- cate- category 0 gory 1 gory 0 gory 1 PU PS* (UNIT, SET, M) With screw terminals PG Weight per unit approx. Price per PU kg V Safety relays, solid-state, for EMERGENCY-STOP and protective doors Basic units -- -- 21) -- --4) 3 DC 24 A 3TK28 40-1BB40 1 1 unit 102 0.180 -- --4) 4 DC 24 A 3TK28 41-1BB40 1 1 unit 102 0.166 1, A3) -- 4 DC 24 Standard devices -- -- 22) Standard devices tv -- -- 1 A 3TK28 42-1BB41 1 1 unit 102 0.168 1, B3) A 3TK28 42-1BB42 1 1 unit 102 0.166 1, C3) A 3TK28 42-1BB44 1 1 unit 102 0.166 Multi-function units 1 1 1 1, A3) A 3TK28 45-1BB41 1 1 unit 102 0.400 1 1 1 1, B3) A 3TK28 45-1BB42 1 1 unit 102 0.400 2 -- 2 -- A 3TK28 45-1BB40 1 1 unit 102 0.415 1HL 4 DC 24 1) The outputs are only safe in conjunction with external actuators with positively-driven contacts. 2) Suitable for solid-state sensor input. 3) tv = Off-delay A = 0.05 ... 3 s, B = 0.5 ... 30 s, C = 5 ... 300 s. 4) An enabling circuit can be used as a signaling circuit. Rated control supply voltages Us 24 V DC and AC 50/60 Hz, 115, 230 V Enabling circuit, floating Enabling circuit, solid-state Signal- Achievable Rated control DT category supply ing voltage Us circuit acc. to EN 954-1 7 Stop Stop Stop Stop cate- cate- cate- category 0 gory 1 gory 0 gory 1 With spring-loaded terminals Order No. PU PS* (UNIT, SET, M) PG Weight per PU approx. Price per PU V kg Safety relays, solid-state, for EMERGENCY-STOP and protective doors Basic units -- -- 21) -- --2) 3 DC 24 B 3TK28 40-2BB40 1 1 unit 102 0.150 -- --2) 4 DC 24 A 3TK28 41-2BB40 1 1 unit 102 0.143 1, A3) -- 4 DC 24 Standard devices -- -- 2 Standard devices tv -- -- 1 B 3TK28 42-2BB41 1 1 unit 102 0.143 1, B3) A 3TK28 42-2BB42 1 1 unit 102 0.146 1, C3) B 3TK28 42-2BB44 1 1 unit 102 0.149 Multi-function units 1 1 1 1, A3) B 3TK28 45-2BB41 1 1 unit 102 0.360 1 1 1 1, B3) B 3TK28 45-2BB42 1 1 unit 102 0.360 2 -- 2 -- B 3TK28 45-2BB40 1 1 unit 102 0.361 1HL 4 DC 24 1) The outputs are only safe in conjunction with external actuators with positively-driven contacts. 2) An enabling circuit can be used as a signaling circuit. 3) tv = Off-delay A = 0.05 ... 3 s, B = 0.5 ... 30 s, C = 5 ... 300 s. * You can order this quantity or a multiple thereof. 7/70 Siemens LV 1 * 2006 3TK28 Safety Relays with relay enabling circuits Overview The SIRIUS safety pilot guides you quickly to the right device Type 1-channel connection 2-channel connection Crossover protection Category acc. to EN 954-1 B 1 2 3 EMERGENCYSTOP Protective door Enabling contacts Signaling Autostart contacts Monitored start 4 Basic units 3TK28 21 -- 3 NO 1 NC -- 3TK28 22 -- 2) 2 NO -- -- 3TK28 23 -- -- 2 NO -- -- 3TK28 24 -- 2 NO -- -- 3TK28 25 3 NO 2 NC 3TK28 27 1) -- 2 NO + 2 NC, delayed 1 NC -- 3TK28 28 1) 2 NO + 2 NC, delayed 1 NC -- -- -- 4 NO -- -- -- Expansion devices (category as for basic unit) 3TK28 30 -- -- Press control devices according acc. to EN 574 3TK28 34 -- -- -- 2 NO +2 NC -- -- -- 3TK28 35 -- -- -- -- -- 3 NO + 1 NC -- -- -- = available -- = not available = corresponds to basic unit 7 1) Only possible for instantaneous enabling contacts. 2) The ON button is not monitored. Siemens LV 1 * 2006 7/71 3TK28 Safety Relays with relay enabling circuits Selection and ordering data Rated control supply voltages Us 24 V DC and AC 50/60 Hz, 24 115, 230 V Enabling contacts Signaling contacts Achievable category acc. to EN 954-1 Rated control DT supply voltage Us PU PS* (UNIT, SET, M) With screw terminals Order No. PG Weight per PU approx. Price per PU kg V Basic units for EMERGENCY-STOP and protective doors Autostart 3 NO 1 NC B, 1, 2, 3 AC/DC 24 } 3TK28 21-1CB30 1 1 unit 102 0.276 2 NO -- B, 1, 2, 3, 4 AC/DC 24 } 3TK28 22-1CB30 1 1 unit 102 0.271 -- B, 1, 2, 3, 4 AC/DC 24 } 3TK28 23-1CB30 1 1 unit 102 0.271 -- B, 1, 2, 3 AC/DC 24 } 3TK28 24-1CB30 1 1 unit 102 0.254 DC 24 } 3TK28 24-1BB40 1 1 unit 102 0.249 AC 115 A 3TK28 24-1AJ20 1 1 unit 102 0.294 AC 230 } 3TK28 24-1AL20 1 1 unit 102 0.288 Monitored start 2 NO Autostart 3TK28 21 to 3TK28 24 with screw-type connection 2 NO Autostart / monitored start 3 NO 2 NC DC 24 } 3TK28 25-1BB40 1 1 unit 102 0.423 AC 24 } 3TK28 25-1AB20 1 1 unit 102 0.421 AC 115 } 3TK28 25-1AJ20 1 1 unit 102 0.519 AC 230 } 3TK28 25-1AL20 1 1 unit 102 0.516 B, 1, 2, 3, 41) DC 24 } 3TK28 27-1BB40 1 1 unit 102 0.497 AC 24 } 3TK28 27-1AB20 1 1 unit 102 0.496 AC 115 } 3TK28 27-1AJ20 1 1 unit 102 0.650 AC 230 } 3TK28 27-1AL20 1 1 unit 102 0.650 B, 1, 2, 3, 41) DC 24 } 3TK28 27-1BB41 1 1 unit 102 0.495 AC 24 B 3TK28 27-1AB21 1 1 unit 102 0.499 AC 115 B 3TK28 27-1AJ21 1 1 unit 102 0.650 AC 230 A 3TK28 27-1AL21 1 1 unit 102 0.650 B, 1, 2, 3, 41) DC 24 } 3TK28 28-1BB40 1 1 unit 102 0.496 AC 24 B 3TK28 28-1AB20 1 1 unit 102 0.500 AC 115 A 3TK28 28-1AJ20 1 1 unit 102 0.650 AC 230 A 3TK28 28-1AL20 1 1 unit 102 0.650 B, 1, 2, 3, 41) DC 24 } 3TK28 28-1BB41 1 1 unit 102 0.499 AC 24 B 3TK28 28-1AB21 1 1 unit 102 0.501 AC 115 B 3TK28 28-1AJ21 1 1 unit 102 0.657 AC 230 A 3TK28 28-1AL21 1 1 unit 102 0.650 B, 1, 2, 3, 4 Monitored start 3TK28 25 with screw-type connection OFF-delay, tv = 0.5 ... 30 s 2 NO + 2 NO 1 NC Monitored start OFF-delay, tv = 0.05 ... 3 s 2 NO + 2 NO 7 3TK28 27 and 3TK28 28 with screw-type connection 1 NC Autostart OFF-delay, tv = 0.5 ... 30 s 2 NO + 2 NO 1 NC Autostart OFF-delay, tv = 0.05 ... 3 s 2 NO + 2 NO 1 NC For multi-unit/reusable packaging, see Appendix. 1) Only applicable to the instantaneous enabling contacts. * You can order this quantity or a multiple thereof. 7/72 Siemens LV 1 * 2006 3TK28 Safety Relays with relay enabling circuits Rated control supply voltages Us 24 V DC and AC 50/60 Hz, 24 ... 115, 230 V Enabling contacts Signal- Achievable Rated control DT ing category acc. supply contacts to EN 954-1 voltage Us With spring-loaded terminals Order No. PU PS* (UNIT, SET, M) PG Weight per PU approx. Price per PU kg V Basic units for EMERGENCY-STOP and protective doors Autostart 3 NO 1 NC B, 1, 2, 3 AC/DC 24 } 3TK28 21-2CB30 1 1 unit 102 0.246 2 NO -- B, 1, 2, 3, 4 AC/DC 24 A 3TK28 22-2CB30 1 1 unit 102 0.250 -- B, 1, 2, 3, 4 AC/DC 24 A 3TK28 23-2CB30 1 1 unit 102 0.247 -- B, 1, 2, 3 Monitored start 2 NO Autostart 2 NO AC/DC 24 A 3TK28 24-2CB30 1 1 unit 102 0.230 DC 24 } 3TK28 24-2BB40 1 1 unit 102 0.228 AC 115 B 3TK28 24-2AJ20 1 1 unit 102 0.265 AC 230 B 3TK28 24-2AL20 1 1 unit 102 0.270 Autostart / monitored start 3 NO 2 NC B, 1, 2, 3, 4 DC 24 } 3TK28 25-2BB40 1 1 unit 102 0.374 AC 24 B 3TK28 25-2AB20 1 1 unit 102 0.375 AC 115 B 3TK28 25-2AJ20 1 1 unit 102 0.472 AC 230 B 3TK28 25-2AL20 1 1 unit 102 0.475 Monitored start OFF-delay, tv = 0.5 ... 30 s 2 NO+2 NO 1 NC B, 1, 2, 3, 41) DC 24 } 3TK28 27-2BB40 1 1 unit 102 0.455 AC 24 B 3TK28 27-2AB20 1 1 unit 102 0.454 AC 115 B 3TK28 27-2AJ20 1 1 unit 102 0.606 AC 230 B 3TK28 27-2AL20 1 1 unit 102 0.604 Monitored start OFF-delay, tv = 0.05 ... 3 s 2 NO+2 NO 1 NC B, 1, 2, 3, 41) DC 24 A 3TK28 27-2BB41 1 1 unit 102 0.454 AC 24 B 3TK28 27-2AB21 1 1 unit 102 0.454 AC 115 B 3TK28 27-2AJ21 1 1 unit 102 0.240 AC 230 B 3TK28 27-2AL21 1 1 unit 102 0.605 Autostart OFF-delay, tv = 0.5 ... 30 s 1 NC B, 1, 2, 3, 41) DC 24 } 3TK28 28-2BB40 1 1 unit 102 0.457 AC 24 B 3TK28 28-2AB20 1 1 unit 102 0.468 AC 115 B 3TK28 28-2AJ20 1 1 unit 102 0.609 AC 230 B 3TK28 28-2AL20 1 1 unit 102 0.612 7 2 NO+2 NO Autostart OFF-delay, tv = 0.05 ... 3 s 2 NO+2 NO 1 NC B, 1, 2, 3, 41) DC 24 A 3TK28 28-2BB41 1 1 unit 102 0.450 AC 24 C 3TK28 28-2AB21 1 1 unit 102 0.454 AC 115 B 3TK28 28-2AJ21 1 1 unit 102 0.240 AC 230 B 3TK28 28-2AL21 1 1 unit 102 0.608 For multi-unit/reusable packaging, see Appendix. 1) Only applicable to the instantaneous enabling contacts. * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/73 3TK28 Safety Relays with relay enabling circuits Rated control supply voltages Us 24 V DC and AC 50/60 Hz, 24, 115, 230 V Enabling contacts Signal- Achievable Rated control DT ing category acc. supply contacts to EN 954-1 voltage Us PU PS* (UNIT, SET, M) With screw terminals Order No. PG Weight per PU approx. Price per PU V kg Expansion units for expansion of the contacts for the safety relays (1 enabling contact of the basic unit is required for connecting to the basic unit) 4 NO -corresponds AC/DC 24 } to basic unit AC 115 A AC 230 A 3TK28 30-1CB30 3TK28 30-1AJ20 3TK28 30-1AL20 1 1 1 1 unit 1 unit 1 unit 102 102 102 0.267 0.306 0.306 for use in presses and punches Two-hand control unit, two-channel 2 NO 2 NC 4 DC 24 AC 24 AC 115 AC 230 } } } } 3TK28 34-1BB40 3TK28 34-1AB20 3TK28 34-1AJ20 3TK28 34-1AL20 1 1 1 1 1 unit 1 unit 1 unit 1 unit 102 102 102 102 0.432 0.424 0.519 0.519 Slowing down test apparatus 3 NO 1 NC B 3TK28 35-1BB40 1 1 unit 102 0.495 3TK28 30 Press control devices DC 24 3TK28 34 and 3TK28 35 For multi-unit/reusable packaging, see Appendix. Rated control supply voltages Us 24 V DC and AC 50/60 Hz, 24, 115, 230 V Enabling Signaling Achievable Rated control DT contacts contacts category acc. supply to EN 954-1 voltage Us With spring-loaded terminals Order No. PU PS* (UNIT, SET, M) PG Weight per PU approx. Price per PU V kg Expansion units for expansion of the contacts for the safety relays (1 enabling contact of the basic unit is required for connecting to the basic unit) 4 NO -corresponds AC/DC 24 } to basic unit AC 115 B AC 230 B 3TK28 30-2CB30 3TK28 30-2AJ20 3TK28 30-2AL20 1 1 1 1 unit 1 unit 1 unit 102 102 102 0.244 0.276 0.276 for use in presses and punches Two-hand control unit, two-channel 2 NO 2 NC 4 DC 24 AC 24 AC 115 AC 230 A B B B 3TK28 34-2BB40 3TK28 34-2AB20 3TK28 34-2AJ20 3TK28 34-2AL20 1 1 1 1 1 unit 1 unit 1 unit 1 unit 102 102 102 102 0.383 0.376 0.472 0.472 Slowing down test apparatus 3 NO 1 NC B 3TK28 35-2AB20 1 1 unit 102 0.454 Version DT Order No. Sealable caps to secure against unauthorized adjustment, for 3TK28 27 and 3TK28 28 devices } 3RP19 02 1 5 units 101 0.004 Push-in lugs for screw mounting for 3TK28 21 to 3TK28 35 devices (1 set = 2 units) } 3RP19 03 1 10 units 101 0.002 7 Press control devices AC 24 For multi-unit/reusable packaging, see Appendix. Accessories Price per PU PU PS* (UNIT, SET, M) PG Weight per PU approx. kg * You can order this quantity or a multiple thereof. 7/74 Siemens LV 1 * 2006 3TK28 Safety Relays with contactor relay enabling circuits Overview The SIRIUS safety pilot guides you quickly to the right device Type Connection Crossover protection 1-channel 2-channel Category acc. to EN 954-1 EMERGENCY- Protective STOP door B 1 2 3 Solid-state sensors 4 Cascade input Safety mats 24 V DC with contactor relays mounted on the front 3TK28 50 basic unit -- -- -- -- 3TK28 51 basic unit -- -- -- -- 3TK28 52 basic unit -- -- -- -- 3TK28 53 basic unit 1 3TK28 56 expansion unit -- -- -- -- -- 1 -- 3TK28 57 expansion unit tv -- -- -- -- -- 1 -- Type Enabling Enabling circuit, Signal- Autostart Monicircuit, floating solid-state ing tored circuit start Switching capacity Stop Stop Stop Stop cate- cate- cate- category 0 gory 1 gory 0 gory 1 AC -15 Rated operational voltage Rated control supply Control voltage inputs DC -13 DC AC AC DC 24 V 230 V 600 V 24 V at at U = 230 V U = 24 V AC AC DC 115 V 230 V 24 V with contactor relays mounted on the front 3TK28 50 basic unit 3 -- -- -- -- 6A 10 A 3TK28 51 basic unit 2 -- -- -- 1 NC 6A 10 A -- 3TK28 52 basic unit 6 -- -- -- 1 NC 6A 10 A -- -- 3TK28 53 basic unit 3 -- 1 -- -- 6A 10 A -- -- 1 3TK28 56 expansion unit 6 -- 1 -- 1 NC -- -- 6A 10 A -- -- 1 3TK28 57 expansion unit tv -- 3 1 -- -- -- -- 6A 10 A -- -- 1 = available 7 -- = not available = corresponds to basic unit Siemens LV 1 * 2006 7/75 3TK28 Safety Relays with contactor relay enabling circuits Selection and ordering data Rated control supply voltages Us 24 V DC and AC 50/60 Hz, 115, 230 V Enabling circuit, floating Enabling circuit, solid-state Signaling circuit Achievable category acc. to EN 954-1 Stop Stop Stop Stop cate- cate- cate- category 0 gory 1 gory 0 gory 1 Rated control DT supply voltage Us PU PS* (UNIT, SET, M) With screw terminals Order No. PG Weight per PU approx. Price per PU V kg Safety relays, solid-state, with contactor relays, for EMERGENCY-STOP and protective doors Basic units 3 -- -- -- -- 3 DC 24 A 3TK28 50-1BB40 1 1 unit 102 0.819 AC 115 B 3TK28 50-1AJ20 1 1 unit 102 0.765 AC 230 B 3TK28 50-1AL20 1 1 unit 102 0.770 Basic units 2 -- -- -- 1 NC 3 DC 24 B 3TK28 51-1BB40 1 1 unit 102 0.821 AC 115 B 3TK28 51-1AJ20 1 1 unit 102 0.770 AC 230 B 3TK28 51-1AL20 1 1 unit 102 0.767 Basic units 6 -- -- -- 1 NC 3 DC 24 A 3TK28 52-1BB40 1 1 unit 102 0.919 AC 230 B 3TK28 52-1AL20 1 1 unit 102 0.870 Basic units 3 -- 11) -- -- 4 DC 24 A 3TK28 53-1BB40 1 1 unit 102 0.714 -- 1 NC corresponds DC 24 to basic unit B 3TK28 56-1BB40 1 1 unit 102 0.785 -- -- corresponds DC 24 basic unit B 3TK28 57-1BB41 1 1 unit 102 0.682 B 3TK28 57-1BB42 1 1 unit 102 0.679 B 3TK28 57-1BB44 1 1 unit 102 0.650 Expansion units2) 6 -- 1 Expansion units tv2) -- 3, A 1 3, B 3, C 1) Suitable for solid-state sensor input. 7 2) For expansion of the contacts for the 3TK28 41, 3TK28 42, 3TK28 45, 3TK28 50, 3TK28 51, 3TK28 52, 3TK28 53 standard and basic units. * You can order this quantity or a multiple thereof. 7/76 Siemens LV 1 * 2006 3TK28 Safety Relays with contactor relay enabling circuits Rated control supply voltages Us 24 V DC and AC 50/60 Hz, 115, 230 V Enabling circuit, floating Enabling circuit, solid-state Signal- Achievable category ing circuit acc. to EN 954-1 Stop Stop Stop Stop cate- cate- cate- category 0 gory 1 gory 0 gory 1 Rated control DT With spring-loaded terminals PU (UNIT, supply SET, M) voltage Us Order No. PS* PG Weight per PU approx. Price per PU kg V Safety relays, solid-state, with contactor relays, for EMERGENCY-STOP and protective doors Basic units 3 -- -- -- -- 3 DC 24 B 3TK28 50-2BB40 1 1 unit 102 0.820 AC 115 B 3TK28 50-2AJ20 1 1 unit 102 0.650 AC 230 B 3TK28 50-2AL20 1 1 unit 102 0.761 Basic units 2 -- -- -- 1 NC 3 DC 24 B 3TK28 51-2BB40 1 1 unit 102 0.650 AC 115 B 3TK28 51-2AJ20 1 1 unit 102 0.650 AC 230 B 3TK28 51-2AL20 1 1 unit 102 0.768 Basic units 6 -- -- -- 1 NC 3 DC 24 B 3TK28 52-2BB40 1 1 unit 102 0.935 AC 230 B 3TK28 52-2AL20 1 1 unit 102 0.878 Basic units 3 -- 11) -- -- 4 DC 24 B 3TK28 53-2BB40 1 1 unit 102 0.705 -- 1 NC corresponds DC 24 to basic unit B 3TK28 56-2BB40 1 1 unit 102 0.750 -- -- corresponds DC 24 to basic unit Expansion units2) 6 -- 1 2) Expansion units tv -- 3, A 1 3, B 3, C B 3TK28 57-2BB41 1 1 unit 102 0.650 B 3TK28 57-2BB42 1 1 unit 102 0.677 C 3TK28 57-2BB44 1 1 unit 102 0.650 1) Suitable for solid-state sensor input. 7 2) For expansion of the contacts for the 3TK28 41, 3TK28 42, 3TK28 45, 3TK28 50, 3TK28 51, 3TK28 52, 3TK28 53 standard and basic units. * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/77 Interface Converters 3RS17 interface converters Overview Application Interface converters perform the coupling function for analog signals on both the input side and the output side. They are indispensable when processing analog values with electronic controls. Under harsh industrial conditions in particular, it is often necessary to transmit analog signals over long distances. This means that electrical isolation is essential due to the different supply systems. The resistance of the wiring causes potential differences and losses which must be prevented. Electromagnetic disturbance and overvoltages can affect the signals on the input side in particular or even destroy the analog modules. All terminals of the 3RS17 interface converters are safe up to a voltage of 30 V DC and protected against switching poles. Short-circuit protection is an especially important function for the outputs. The devices are EMC-tested according to * EN 50081 (basic technical standard for emitted interference), * EN 61000-6-2 (basic technical standard for immunity to interference). The analog signals comply with * IEC 60381-1/2. Converters are used in analog signal processing for * Electrical isolation * Conversion of normalized and non-normalized signals * Matching of gain and impedances * Conversion to a frequency for processing by a digital input * Overvoltage and EMC protection * Short-circuit protection of the outputs * Potential duplication Application example: Interface converter in analog signal evaluation Sensor/ analog value sensor 0...10 V 0/4...20 mA 0...10 V 0/4...20 mA 0...10 kHz U, I U, I, F Converter 3RS17 Electronic control Input 0...10 V 0/4...20 mA Output NSB01311b 0...10 V 0/4...20 mA U, I U, I, Converter 3RS17 Actuator with analog input 3RS17 25 manual/automatic converter For special applications in which analog signals have to be simulated, or during plant commissioning when the actual process value is not yet available, the 3RS17 25 devices feature an adjustable potentiometer for entering setpoints manually and a manual/automatic switch. The adjustable potentiometer for the 3RS17 25 devices is used to simulate analog output signals when the changeover switch is set to "Manual" and the control supply voltage is applied, without the need for an analog input signal; the scale ranges from 0 % ... 100 %. 7 Example: When it is set for an output of 4 mA ... 20 mA, the 0 % scale value on the potentiometer represents an output current of 4 mA and the 100 % scale value represents an output current of 20 mA. In the "Auto" switch position, the output signal follows the input signal proportionally regardless of the potentiometer setting. 7/78 Siemens LV 1 * 2006 Interface Converters 3RS17 interface converters Selection and ordering data All converters except the passive single interface converters have a yellow LED for indicating "Power on". Input Output Width Rated control supply voltage Us Electrical DT isolation Screw-type connection Order No. PU PS* (UNIT, SET, M) PG Price per PU Weight per PU approx. kg mm V 0 ... 10 V 6.2 AC/DC 24 2 paths A 3RS17 00-1AD00 1 1 unit 101 0.053 0 ... 20 mA 6.2 AC/DC 24 2 paths A 3RS17 00-1CD00 1 1 unit 101 0.052 4 ... 20 mA 6.2 AC/DC 24 2 paths A 3RS17 00-1DD00 1 1 unit 101 0.052 0 ... 10 V 6.2 AC/DC 24 2 paths A 3RS17 02-1AD00 1 1 unit 101 0.052 0 ... 20 mA 6.2 AC/DC 24 2 paths A 3RS17 02-1CD00 1 1 unit 101 0.052 4 ... 20 mA 6.2 AC/DC 24 2 paths A 3RS17 02-1DD00 1 1 unit 101 0.052 0 ... 10 V 6.2 AC/DC 24 2 paths A 3RS17 03-1AD00 1 1 unit 101 0.052 0 ... 20 mA 6.2 AC/DC 24 2 paths A 3RS17 03-1CD00 1 1 unit 101 0.052 4 ... 20 mA 6.2 AC/DC 24 2 paths A 3RS17 03-1DD00 1 1 unit 101 0.053 6.2 AC/DC 24 2 paths A 3RS17 05-1FD00 1 1 unit 101 0.053 17.5 AC/DC 24 ... 240 3 paths A 3RS17 05-1FW00 1 1 unit 101 0.090 AC/DC 24 2 paths A 3RS17 05-1KD00 1 1 unit 101 0.053 AC/DC 24 ... 240 3 paths A 3RS17 05-1KW00 1 1 unit 101 0.099 Single interface converters, active 0 ... 10 V 0 ... 20 mA 4 ... 20 mA Switchable multi-range converters, active 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA, switchable 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA, switchable 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA, switchable 0 ... 50 Hz, 6.2 0 ... 100 Hz, 17.5 0 ... 1 kHz, 0 ... 10 kHz, switchable Switchable universal converters, active, with 16 input ranges and 3 output ranges 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA, switchable 17.5 2 paths A 3RS17 06-1FD00 1 1 unit 101 0.082 3 paths A 3RS17 06-1FE00 1 1 unit 101 0.082 AC/DC 24 ... 240 3 paths A 3RS17 06-1FW00 1 1 unit 101 0.090 AC/DC 24 7 0 ... 60 mV, 0 ... 100 mV, 0 ... 300 mV, 0 ... 500 mV, 0 ... 1 V, 0 ... 2 V, 0 ... 5 V, 0 ... 10 V, 0 ... 20 V, 2 ... 10 V, 0 ... 5 mA, 0 ... 10 mA, 0 ... 20 mA, 4 ... 20 mA, +/-5 mA, +/-20 mA, switchable Switchable multi-range converters, active, with manual/automatic switch and single potentiometer as manual analog signal transmitter 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA, switchable 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA, switchable 17.5 2 paths A 3RS17 25-1FD00 1 1 unit 101 0.085 AC/DC 24 ... 240 3 paths A 3RS17 25-1FW00 1 1 unit 101 0.102 Input Output Width Number Channels AC/DC 24 Electrical DT isolation Screw-type connection Order No. mm PU PS* (UNIT, SET, M) PG Price per PU Weight per PU approx. kg Single interface converters, passive 0/4 ... 20 mA 0/4 ... 20 mA 6.2 12.5 1 2 paths A 3RS17 20-1ET00 1 1 unit 101 0.049 1 2 paths A 3RS17 21-1ET00 1 1 unit 101 0.059 2 2 paths A 3RS17 22-1ET00 1 1 unit 101 0.070 * You can order this quantity or a multiple thereof. Siemens LV 1 * 2006 7/79 Interface Converters 3RS17 interface converters All converters except the passive single interface converters have a yellow LED for indicating "Power on". Input Output Width Rated control Electrical DT supply voltage Us isolation Spring-loaded terminal Order No. PU PS* (UNIT, SET, M) PG Price per PU Weight per PU approx. kg mm V 0 ... 10 V 6.2 AC/DC 24 2 paths A 3RS17 00-2AD00 1 1 unit 101 0.047 0 ... 20 mA 6.2 AC/DC 24 2 paths A 3RS17 00-2CD00 1 1 unit 101 0.047 4 ... 20 mA 6.2 AC/DC 24 2 paths A 3RS17 00-2DD00 1 1 unit 101 0.047 0 ... 10 V 6.2 AC/DC 24 2 paths C 3RS17 02-2AD00 1 1 unit 101 0.047 0 ... 20 mA 6.2 AC/DC 24 2 paths A 3RS17 02-2CD00 1 1 unit 101 0.045 4 ... 20 mA 6.2 AC/DC 24 2 paths A 3RS17 02-2DD00 1 1 unit 101 0.048 0 ... 10 V 6.2 AC/DC 24 2 paths A 3RS17 03-2AD00 1 1 unit 101 0.047 0 ... 20 mA 6.2 AC/DC 24 2 paths C 3RS17 03-2CD00 1 1 unit 101 0.049 4 ... 20 mA 6.2 AC/DC 24 2 paths A 3RS17 03-2DD00 1 1 unit 101 0.047 Single interface converters, active 0 ... 10 V 0 ... 20 mA 4 ... 20 mA Switchable multi-range converters, active 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA, switchable 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA, switchable 6.2 AC/DC 24 2 paths A 3RS17 05-2FD00 1 1 unit 101 0.048 17.5 AC/DC 24 ... 240 3 paths A 3RS17 05-2FW00 1 1 unit 101 0.092 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA, switchable 0 ... 50 Hz, 6.2 0 ... 100 Hz, 17.5 0 ... 1 kHz, 0 ... 10 kHz, switchable AC/DC 24 2 paths C 3RS17 05-2KD00 1 1 unit 101 0.047 AC/DC 24 ... 240 3 paths A 3RS17 05-2KW00 1 1 unit 101 0.092 0.078 Switchable universal converters, active, with 16 input ranges and 3 output ranges 0 ... 60 mV, 0 ... 100 mV, 0 ... 300 mV, 0 ... 500 mV, 0 ... 1 V, 0 ... 2 V, 0 ... 5 V, 0 ... 10 V, 0 ... 20 V, 2 ... 10 V, 0 ... 5 mA, 0 ... 10 mA, 0 ... 20 mA, 4 ... 20 mA, +/-5 mA, +/-20 mA, switchable 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA, switchable 17.5 AC/DC 24 AC/DC 24 ... 240 2 paths A 3RS17 06-2FD00 1 1 unit 101 3 paths A 3RS17 06-2FE00 1 1 unit 101 0.077 3 paths A 3RS17 06-2FW00 1 1 unit 101 0.094 7 Switchable multi-range converters, active, with manual/automatic switch and single potentiometer as manual analog signal transmitter 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA, switchable 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA, switchable 17.5 AC/DC 24 2 paths A 3RS17 25-2FD00 1 1 unit 101 0.078 AC/DC 24 ... 240 3 paths A 3RS17 25-2FW00 1 1 unit 101 0.095 Input Output Width Number Channels Electrical DT isolation Spring-loaded terminal Order No. PU PS* (UNIT, SET, M) PG Price per PU mm Weight per PU approx. kg Single interface converters, passive 0/4 ... 20 mA 0/4 ... 20 mA 6.2 12.5 1 2 paths A 3RS17 20-2ET00 1 1 unit 101 0.044 1 2 paths A 3RS17 21-2ET00 1 1 unit 101 0.057 2 2 paths A 3RS17 22-2ET00 1 1 unit 101 0.066 7 * You can order this quantity or a multiple thereof. 7/80 Siemens LV 1 * 2006