- 440 - REV.1 Oct.-2003
W005M THRU W10M
Single Phase 1.5 AMPS. Silicon Bridge Rectifiers
Voltage Range
50 to 1000 Volts
Current
1.5 Amperes
F
eatures
UL Recognized File # E-96005
Surge overload ratings to 40 amperes peak
Ideal for printed circuit board
Reliable low cost construction technique
results in inexpensive product
High temperature soldering guaranteed:
260/ 10 seconds / 0.375” ( 9.5mm )
lead length at 5 lbs. ( 2.3 Kg ) tension
M
echanical Data
Case: Molded plastic
Lead: Solder plated
Polarity: As marked
Weight: 1.10 grams
WOB
Dimensions in inches and (millimeters)
M
aximum Ratings and Electrical Characteristics
Rating at 25ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Type Number Symbol W005M W01M W02M W04M W06M W08M W10M Unit
s
Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 V
Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 V
Maximum DC Blocking Voltage VDC 50 100 200 400 600 800 1000 V
Maximum Average Forward Rectified Current
@TA=50I(AV) 1.5 A
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method ) IFSM 40 A
Maximum Instantaneous Forward Voltage
@1.0A VF1.0 V
Maximum DC Reverse Current @ TA=25
at Rated DC Blocking Voltage @ TA=100IR10
500 uA
uA
Typical thermal Resistance (Note) RθJA
RθJL 36
13 /W
Operating Temperature Range TJ-55to+125
Storage Temperature Range TSTG -55to+150
Note: Thermal Resistance from Juncton to Ambient and from Junction to Lead Mounted on P.C.B.
At 0.375” (9.5mm) Lead Lengths with 0.47 x 0.47” (12 x 12mm) Copper Pads.
- 441 -
RATINGS AND CHARACTERISTIC CURVES (W005M THRU W10M)
FIG.1- MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT PER BRIDGE ELEMENT
PEAK FORWARD SURGE CURRENT. (A)
12 10 20 10040 60
0
10
40
30
20
50
NUMBER OF CYCLES AT 60Hz
FIG.2- MAXIMUM FORWARD CURRENT DERATING
CURVE
AVERAGE FORWARD CURRENT. (A)
20 40 60 80 100 120 140
0
.2
.4
.6
.8
1.0
1.2
1.4
1.6
AMBIENT TEMPERATURE. ( C)
o
FIG.3- TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER BRIDGE ELEMENT
INSTANTANEOUS FORWARD CURRENT. (A)
00.2 0.4 0.6 0.8 1.0 1.2 1.4
0.01
0.1
1.0
20
10
FORWARD VOLTAGE. (V)
Tj=25 C
Pulse Width=300 s
1% Duty Cycle
o
FIG.4- TYPICAL REVERSE CHARACTERISTICS
PER BRIDGE ELEMENT
INSTANTANEOUS REVERSE CURRENT.( A)
020 40 60 80 100 120 140
.01
.10
1.0
10
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
Tj=100 C
0
Tj=25 C
0