IRANSYS MMBTA42 ELECTRONICS NPN SMALL SIGNAL SURFACE MOUNT TRANSISTOR LIMITED Features Epitaxial Planar Die Construction SOT-23 Complementary PNP Type Available | lea Dim | Min | Max (MMBTAQ2) ~ Ideal for Medium Power Amplification and [] O87 | 051 Switching ror VIEW | B 1.19 1.40 ry Cc 2.10 2.50 Mechanical Data [e] le] 4 D 0.89 | 1.05 Case: SOT-23, Molded Plastic E kor E O45 | 0-64 Terminals: Solderable per MIL-STD-202, G 178 | 2.05 Method 208 k+>| H 2.65 | 3.05 Terminal Connections: See Diagram { \ M J 0.013 | 0.15 Marking: K3M YEW + ~*~ fo K | oe9 | 1.10 Weight: 0.008 grams (approx.) emf F L 045 | 064 M 0.076 | 0.178 All Dimensions in mm Maximum Ratings @ Ta= 25 C unless otherwise specified Characteristic Symbol MMBTA42 Unit Collector-Base Voltage VcBo 300 Vv Collector-Emitter Voltage VcEO 300 Vv Emitter-Base Voltage VEBO 6.0 Vv Collector Current (Note 1) (Note 3) Ic 200 mA Power Dissipation (Note 1) Pa 350 mw Thermal Resistance, Junction to Ambient (Note 1) R va 357 K/iW Operating and Storage and Temperature Range Tj, ste -55 to +150 Cc Electrical Characteristics @ Ta = 25 C unless otherwise specified Characteristic symbol | Min | Max | Unit | Test Condition OFF CHARACTERISTICS (Note 2) Collector-Base Breakdown Voltage V(BR)CBO 300 Vv Ic = 100 A, le=0 Collector-Emitter Breakdown Voltage V(BR)CEO 300 V Ic = 1.0mA, IB = 0 Emitter-Base Breakdown Voltage V(BR)EBO 6.0 Vv le =100 A, Ic =0 Collector Cutoff Current IcBo 100 nA Vos = 200V, le=0 Collector Cutoff Current lEBO 100 nA Voce = 6.0V, Ic = 0 ON CHARACTERISTICS (Note 2) 25 Io = 1.0MA, Voce = 10V DC Current Gain hre 40 Ic = 10mA, Vce = 10V 40 Io = 30mA, VceE= 10V Collector-Emitter Saturation Voltage VCE(SAT) 0.5 Vv I = 20mMA, Ip = 2.0MA Base- Emitter Saturation Voltage VBE(SAT) 0.9 Vv I = 20mMA, Ip = 2.0MA SMALL SIGNAL CHARACTERISTICS Output Capacitance Cob 3.0 pF Vos = 20V, f= 1.0MHz, le = 0 Current Gain-Bandwidth Product fr 50 MHz ice South = 10mA, Notes: 1. Valid provided that terminals are kept at ambient temperature. 2. Pulse test: Pulse width 300 s, dutycycle 2%. 3. When operated within safe operating area constraints.