Engine Temperature Sensor (ETS)
GE-1711/GE-1797
Features
High accuracy and long term stability
Fast response time
Pigtail connector
Existing eld proven design
Alternate RvT curves possible
Different connection systems to meet package
requirements
180°C max operating temperature
Both brass and stainless steel congurations
available depending on media/interface/
environment
Other resistance and beta values possible
RoHS compliant
Applications
Engine coolant temperature
Engine oil temperature
Engine fuel temperature
Amphenol
Advanced Sensors
These temperature sensors monitor the temperature of the coolant, oil, or fuel being used in an engine.
These sensors’ purpose is to provide a signal output that is proportional to engine temperature. This signal
can be used as an input to a temperature gauge, provide input to an ECU (Engine Control Unit) or control a
cooling fan circuit.
2
GE-1711 / GE-1797 Specifications
Operating Temperature Range:
-40°C to 180°C
Storage Temperature Range:
-40 to 150 °C
R @ 25°C :
10,000 Ohms ± 5.00%
Beta (25/85)°C:
3977K
Response time:
4 seconds from water to water
Housing Material:
GE-1711: C34500 Brass
GE-1797: 316 Stainless Steel
Weight:
~28 grams
Available Connectors:
Delphi Metri-pack 150
Amphenol Sine ATM series
Mating Connector:
Delphi: 12052641
Amphenol Sine: ATM06-2S
Thermistor Material System:
Material 1
R vs. T
Temp.
(°C)
Resistance
(Ω)
Resistance
Tolerance
(±%)
Tolerance
(±°C)
-40 333562 7.80 1.18
-25 129925 7.04 1.18
0 32639 5.94 1.16
25 10000 5.00 1.14
85 1070 6.77 2.15
100 678.1 7.14 2.44
180 96.07 8.72 4.29
Part
Number Connector Type Housing
Material
GE-1711 Delphi Metri-Pack 150 CA345 Brass
GE-1797 Delphi Metri-Pack 150 316 Stainless
Steel
GE-1711ATM Amphenol Sine ATM
Series CA345 Brass
GE-1797ATM Amphenol Sine ATM
Series
316 Stainless
Steel
Recommended Mounting Interface
3
GE-1711 / GE-1797 Dimensions
GE-1711 / GE-1797
GE-1711ATM / GE-1797ATM
AAS-920-672C - 02/2019
www.amphenol-sensors.com
© 2019 Amphenol Corporation. All Rights Reserved. Specications are subject to change without notice.
Other company names and product names used in this document are the registered trademarks or
trademarks of their respective owners.
Amphenol
Advanced Sensors
Test Passing Criteria
High Potential Test Apply potential difference of 300 VDC between the sensor leads & housing,
max allowable leakage current is 40 μA
Four Temperature
Parametric Verify resistance at -40, 25, 125, and 180°C
Thermal Time Constant Must take less than 4 seconds for thermistor to reach 63.2% of the
temperature difference between 25°C and 65°C in water
Wire Pull Force Leads are pulled with 20lbs of force, must meet standard performance
requirements
Static Thermal Cycle Part is put through 120 cycles from -40°C to 175°C, must meet standard
performance requirements. Outside of brass not required to pass
Mechanical Drop Fall from 1 meter onto concrete, repeated for each of three axes. No cracks,
deformations, or irregularities that would render part unusable in the field
Fluids Compatibility Immerse for 24 hours in unleaded gasoline, 2 cycle oil, fuel, and sour gas. No
cracks, voids, or changes in fit, form, or function
Vibration & Thermal
Cycling
Vibration of 0 to 53.1G for 500 hours and thermal cycled. Must meet standard
performance requirements
Salt Spray
5% salt water sprayed for 10 minutes, room temperature air for 20 minutes,
then heated to 130°F for 30 minutes. Repeat cycle 5 days for 5 weeks. After
the test, sample must be torn down. No water entry permissible, must meet
standard performance requirements
Salt Fog
5% salt solution at 95°F for 500 hours. Dry for 1 week. After the test,
sample must be torn down. No water entry permissible, must meet standard
performance requirements
Water Immersion
Stabilize part at 190°F. Immediately immerse in 32°F solution of paint and
water for 35 minutes. Rotate part 180° after 10 minutes and 90° after an
additional 10 minutes. Remove part and put in 20°F chamber for 1 hour. After
the test, sample must be torn down. No water entry permissible, must meet
standard performance requirements
GE-1711 / GE-1797 Specifications
Formal validation report available upon request.