T9
Circuit breakers
www.schurter.com/pg17_18_19
Description
Thermal circuit breaker
Supplementary protector for general industrial use
Cycling trip-free release
Reset type
Single pole
Mounting style: T9-211: Threaded neck with nut PA 66
T9-311: Threaded neck with nut nickel plated
T9-611: Snap-in front side
T9-711: Snap-in rear side
Standards
IEC 60934 (4 16 A)
UL 1077 (316 A)
CSA C22.2 235 (316 A)
GB 17701 (4 16 A)
Applications
Power supplies
UPS
Power tools
Household appliances
Industrial appliances
Medical diagnostic appliances
HVAC
Weblinks
Approvals: http://www.schurter.com/approvals
RoHS: http://www.schurter.com/rohs
T9-211: Threaded neck
with nut PA 66
Resettable Thermal Circuit Breaker, Single Pole, 3 16 A
Technical Data
Rated voltage AC 240 V, 50/60 Hz
(see approvals) DC 48/32 V
Rated current 3 –16 A
Conditional short circuit capacitiy IEC: Inc, PC1, AC 240 V 2 kA
UL / CSA: SC, AC 240 V / DC 48/32 V 2 kA, C1
Overload rating UL / CSA OL0 240 VAC
OL0 48 VDC and 32 VDC
Degree of protection Accessible range IP 40
Termination range IP 00
Endurance minimum IEC: 200% In, cos phi 0.6 min. 50 cycles
Endurance typical 3 8 A: 150% In, cos phi 0.9 2500 cycles
1016 A: 150% In, cos phi 0.9 6000 cycles
Dielectric strength AC 1500 V
Insulation resistance DC 500 V > 1000 MΩ
Ambient temperature 5–16 A -30 °C to 60 °C
4 A -30 °C to 50 °C
3 A -5 °C to 60 °C
Type of actuation Reset Type (manual) R
Type of tripping Cycling trip-free
Weight 9 – 13 g
Rated current Internal resistance
(mΩ)
Rated current Internal resistance
(mΩ)
3 A 65.0 10 A 7.3
4 A 21.6 12 A 7.0
5 A 23.6 14 A 4.8
6 A 16.3 15 A 4.3
7 A 15.3 16 A 3.9
8 A 12.9
Typical internal resistance
1
circuit breakers
T9-311: Threaded neck
with nut nickel plated
T9-611: Snap-in from front side T9-711: Snap-in from back side
Tripping Characteristics
2 3 4 51 6 7 8 1 0
Trip Time
[min] [sec]
Multiple of Rated Current [ x In ]
10'000
1'000
100
1
0.1
10
30
20
10
5
3
1
60
T9
Rated Current
Reference Temperature + 23˚C
5 A -16 A (TC-1)
Type
4 A (TC-2)
1.05
1.35
1.45
Effect of ambient temperature
The units are calibrated for an ambient temperature of +23°C. To
determine the rated current for a lower or higher ambient temperature,
use a correction factor (typical value) from the table below:
Ambient temperature (°C) Correction factor
-5 0,85
+10 0,95
+23 1,00
+40 1,08
+60 1,21
Example
Rated current at +23°C 10,0 A
Ambient temperature +60°C
Correction factor 1,21
Chosen rated current at +60°C
ambient temperature 10,0 A x 1,21 = 12,1 A
Approvals
Rated currents Rated voltage AC Rated voltage DC
UL UL 1077 3–12 A 240 V 48 V
14–16 A 240 V 32 V
UL CSA C22.2 235 3–12 A 240 V 48 V
14–16 A 240 V 32 V
VDE IEC 60934 4–12 A + 3 A pending 240 V 48 V
14–16 A 240 V 32 V
The specifications, descriptions and illustrations indicated in this document are based
on current information. All content is subject to modifications and amendments.
T9 Circuit breakers
www.schurter.com/pg17_18_19
2
2 3 4 51 6 7 8 1 0
Trip Time
[min] [sec]
Multiple of Rated Current
[ x In ]
10'000
1'000
100
1
0.1
10
30
20
10
5
3
1
60
+ 23˚C
T9
Rated Current
Reference Temperature
3 A (TC-2)
Type
1.05
1.5
Order Code
Basic type
T9 single pole, thermal overload switch, cycling trip-free
Mounting style
2 Threaded neck type with nut PA 66
3 Threaded neck type with nut nickel-plated
6 Snap-in type from front side (0.8…2.0 mm)
7 Snap-in type from rear side (0.5…3.0 mm)
Actuation type
1 Reset Type (R-type)
Terminal type
1 6.3 x 0.8 mm quick connect terminals IEC 61210
Front printing
C rated current not marked
P rated current printed on front (T9-611 only)
Rated current
3 A 10 A
4 A 12 A
5 A 14 A
6 A 15 A
7 A 16 A
8 A
T9 - 6 1 1 P - 10A
Accessories
Protection cover TZZ31 for IP 65 for type T9-211/311:
13.6
17
Order number Type description
4404.0039 TZZ31 Protection cover for IP 65
4400.0420 TZZ11 Knurled nut nickel-plated
4400.0559 TZZ11-414 Knurled nut black
4400.0425 TZZ12 Additional hexagonal nut nickel-plated
4404.0072 TZZ51 Additional hexagonal nut PA 66
3/8"-27UNS 2.5
SW 14
Hexagonal nut TZZ12 / TZZ51:
T9
Circuit breakers
www.schurter.com/pg17_18_19
3
circuit breakers
Dimensions
T9-211/311
T9-611
T9-711
36.110.4ø 15.4 10 19
58 3/8"-27UNS6.3x0.8
±0.3
±0.4
13.6
8.6
SW14
19
±0.3 ±0.6 ±0.3 ±0.2
±0.2
max. torque 0.6 Nm
8.99.6
9.6
+0.1
0
343.4ø 15.4 10 19
58 6.3x0.8
±0.3
±0.4
13.6
19
±0.3 ±0.5 ±0.3 ±0.2
±0.2
16
15
+0.15
0 16+0.15
0 16+0.15
0
+0.15
0
14+0.15
0
43.13.4ø 15.4 10 25
58 6.3x0.8
±0.3
±0.4
13.6
11
ø 15.5
±0.2 ±0.7 ±0.3 ±0.5
±0.3
13.9
15.9
0
-0.1
0
-0.1
Panel thickness S = 0.8–5.5 mm
Panel thickness S = 0.8–2.0 mm Recommended panel thickness: 0.8/1.2/1.6/2.0 mm
Panel thickness S = 0.5–3.0 mm
circuit breakers
T9 Circuit breakers
www.schurter.com/pg17_18_19
4