MODEL TL-5920 International size reference: C, ER26500 TECHNICAL DATA (Typical values @+ 25C for batteries stored for one year or less) Nominal capacity @ 3 mA, to 2 V 8.5 Ah Rated voltage 3.6 V Maximum recommended continuous current 230 mA Maximum pulse current capability 400 mA Weight 49.5 g (1.75 oz) Volume 26 cc Operating temperature range -55 C to +85 C Li metal content approx. 2.5 g U.L. Component Recognition, MH 12193 Volts DISCHARGE CHARACTERISTICS @ +25C 4.0 3.5 3.0 2.5 2.0 180 ~20 mA (6.8 Ah) 33 56 ~100 mA ~60 mA (2.2 Ah) (4.0 Ah) 1.5 330 ~10 mA (7.9 Ah) 1.2 K ~3 mA (8.5 Ah) 36 k ~100 A (6.9 Ah) TERMINATIONS & ORDERING NO. 1.0 1 10 100 1000 10000 VOLTAGE VS. TEMPERATURE Volts SUFFIX- /S STANDARD 15-5920-21500 SUFFIX- /T SOLDER TABS 15-5920-31500 SUFFIX- /P AXIAL PINS 15-5920-41500 100000 Hours CAPACITY VS. CURRENT Ah 3.7 8.0 3.5 250 A 3.3 25 C 1 mA 6.0 3.1 55 C 10 mA 2.9 25 mA 4.0 2.7 2.5 0 C -30 C 25 A 72 C 100 mA 2.3 2.0 -50 -30 -10 10 30 50 70 90 C 0.1 1 10 100 mA iXtra - Long Term High Performance Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. ECN 1501879 Rev. B 11/08 Page 1 of 2 TL-5920 CELL FEATURES 3.6 V Primary lithium-thionyl chloride (Li-SOCl2) Fast voltage recovery after long term storage and/or usage High energy density Low self discharge rate Bobbin construction Hermetic glass-to-metal-sealing Non-flammable electrolyte Volts MAIN APPLICATIONS VOLTAGE RESPONSE AFTER STORAGE After 2 years 3.4 After 1 year After 5 years 3.2 Utility meters (elect., water & gas) Automatic meter reading RF systems Sensors & monitoring systems Tracking systems Wireless security systems Automotive electronics Industrial electronics Ultra Low Power (ULP) After 8 years STORAGE CONDITIONS 3.0 After 10 years 2.8 Pulse applied: 40 mA for 1 sec Storage: RT Background current: None 2.6 2.4 0 200 400 600 800 1000 VOLTAGE RESPONSE Volts 3.5 Cells should be stored in a clean & dry (less than 30 % RH) area For updated information please visit our website www.tadiranbat.com 1200 msec VOLTAGE RESPONSE Volts After 1 year After 2 years 3.5 After 1 year After 2 years After 5 years 3.3 3.3 After 5 years 3.1 3.1 Pulse applied: 40 mA for 100 msec Temperature: RT Background current: 25 A 2.9 Pulse applied: 40 mA for 100 msec Temperature: RT Background current: 45 A 2.9 After 8 years After 8 years 2.7 2.7 0 20 40 60 80 100 120 msec 0 20 40 60 80 100 120 msec iXtra - Long Term High Performance Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. ECN 1501879 Rev. B 11/08 Page 2 of 2