Nominal capacity @ 3 mA, to 2 V 8.5 Ah
Rated voltage 3.6 V
Maximum recommended continuous current 230 mA
Maximum pulse current capability 400 mA
Weight 49.5 g (1.75 oz)
Volume 26 cc
Operating temperature range -55 ºC to +85 ºC
Li metal content approx. 2.5 g
U.L. Component Recognition, MH 12193
SUFFIX- /S STANDARD 15-5920-21500
SUFFIX- /T SOLDER TABS 15-5920-31500
SUFFIX- /P AXIAL PINS 15-5920-41500
TECHNICAL DATA
(Typical values @+ 25ºC for batteries stored for one year or less)
International size reference: C, ER26500
MODEL TL-5920
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
TERMINATIONS & ORDERING NO.
iXtra - Long Term High Performance
ECN 1501879 Rev. B 11/08
Page 1 of 2
DISCHARGE CHARACTERISTICS @ +25ºC
33
~100 mA
(2.2 Ah)
180
~20 mA
(6.8 Ah)
56
~60 mA
(4.0 Ah)
330
~10 mA
(7.9 Ah)
1.2 K
~3 mA
(8.5 Ah)
36 k
~100 µA
(6.9 Ah)
1.0
1.5
2.0
2.5
3.0
3.5
4.0
1 10 100 1000 10000 100000
Hours
Volts
VOLTAGE VS. TEMPERATURE
100 mA
25 mA
10 mA
1 mA
250 µA
25 µA
2.3
2.5
2.7
2.9
3.1
3.3
3.5
3.7
-50-30-101030507090
ºC
Volts CAPACITY VS. CURRENT
-30 °C
0 °C
25 °C
55 °C
72 °C
0.1 1 10 100
2.0
4.0
6.0
8.0
mA
Ah
VOLTAGE RESPONSE
After 1 year
After 2 years
After 5 years
After 8 years
2.7
2.9
3.1
3.3
3.5
0 20 40 60 80 100 120
msec
Volts
VOLTAGE RESPONSE
After 1 year
After 2 years
After 5 years
After 8 years
2.7
2.9
3.1
3.3
3.5
0 20 40 60 80 100 120
msec
Volts
VOLTAGE RESPONSE AFTER STORAGE
After 1 year
After 2 years
After 5 years
After 8 years
After 10 years
2.4
2.6
2.8
3.0
3.2
3.4
0 200 400 600 800 1000 1200
msec
Volts
3.6 V Primary lithium-thionyl chloride (Li-SOCl2)
Fast voltage recovery after long term storage and/or usage
High energy density
Low self discharge rate
Bobbin construction
Hermetic glass-to-metal-sealing
Non-flammable electrolyte
CELL FEATURES
TL-5920
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
iXtra - Long Term High Performance
ECN 1501879 Rev. B 11/08
Page 2 of 2
MAIN APPLICATIONS
Utility meters (elect., water &
gas)
Automatic meter reading
RF systems
Sensors & monitoring systems
Tracking systems
Wireless security systems
Automotive electronics
Industrial electronics
Ultra Low Power
(
ULP
)
Cells should be stored in a
clean & dry (less than 30 %
RH) area
STORAGE CONDITIONS
For updated information please visit
our website www.tadiranbat.com
Pulse applied: 40 mA for 100 msec
Temperature: RT
Background current: 25 µA
Pulse applied: 40 mA for 100 msec
Temperature: RT
Background current: 45 µA
Pulse applied: 40 mA for 1 sec
Storage: RT
Background current: None