Ledex® Solenoids www.ledex.com 1.937.454.2345 Fax: 1.937.898.8624
H25
LINEAR Open Frame
All specifications subject to change without notice.
All catalog products manufactured after
April 1, 2006 are RoHS Compliant
Force values for reference only.
Ledex® C Frame Size C5 — DC Operation
Specifications
Operation Pull
Dieletectric Strength 500 VRMS for one second
Continuous Duty Cycle 100% At 20°C ambient temperature
Intermittent Duty Cycle See below
Coil Insulation Class “B”: 130°C max. temperature
standard. Other temperature classes
are available
Coil Termination 0.025" square pin terminals
Plunger Pole Face 60° conical
Plunger Weight 0.08 oz. (2.2 g)
Total Weight 0.42 oz. (11.9 g)
Dimensions See page H44
Maximum Duty Cycle 100% 50% 25% 10%
Maximum ON Time (sec) ∞ 145 47 14
Watts (@ 20°C) 3 6 12 30
Ampere Turns (@ 20°C) 422 564 844 1268
Coil Data
Resistance Ref # VDC VDC VDC VDC
Part Number (@20°C) Turns (Nom) (Nom) (Nom) (Nom)
C5-273-B-1 2.88 406 3 4 6 9
C5-272-B-1 11.52 795 6 8 12 19
C5-271-B-1 25.77 1222 9 12 18 28
C5-270-B-1 48.65 1642 12 17 24 38
C5-269-B-1 72.84 1968 15 21 30 47
C5-268-B-1 152.20 2860 21 30 43 68
C5-267-B-1 191.73 3202 24 34 48 76
Part Number: C5 - XXX - B- 1
Select from performance chart below
How to Order
Select the part number from the table provided. (For
example, to order a 25% duty cycle unit rated at 48 VDC,
specify C5-267-B-1.
Please see www.ledex.com (click on Stock Products
tab) for our list of stock products available through our
North American distributors.
Performance
Force (Gross, Without Spring)
NOTES:
1. All data is typical.
2. Force testing is done with the solenoid in the
horizontal position.
3. All data reflects operation with no heatsink.
4. Other coil terminations available.
5. Pull versions standard; push versions available.
Stroke - in (mm)
Force - lbs (N)
0 0.02
(0.51)
0.04
(1.02)
0.06
(1.52)
0.08
(2.03)
0.10
(2.54)
0.12
(3.05)
0.14
(3.56)
0.16
(4.06)
0.18
(4.57)
0.20
(5.08)
0
0.2
(0.89)
0.4
(1.78)
0.6
(2.67)
0.8
(3.56)
1.0
(4.45)
1.2
(5.34)
1.4
(6.23)
10% Duty Cycle
25% Duty Cycle
50% Duty Cycle
100% Duty Cycle
Well-suited
for battery
operation.
See the "Battery Operated
Solenoids" section for
complete information.