Features 2:1 Wide Input Voltage Range 20 Watts Output Power 1.6kVDC Isolation UL Certified Fixed Operating Frequency Six-Sided Continuous Shield Standard 50.8 x25.4x10.2mm Package Efficiency to 89% Description The RP20-F series DC/DC converters are certified to UL 60950-1 and to cUL 60950-1. This makes them ideal for all telecom and industrial applications where approved safety standards are required. The industry standard 2" x 1" package meets military standards for thermal shock and vibration tolerance. Selection Guide 12V, 24V and 48V Input Types RP20-F Part Number Input Range VDC Output Voltage VDC Output Current mA POWERLINE DC/DC-Converter 20 Watt 2" x 1" Single & Dual Output Input(4) Efficiency(5) Capacitive(6) Current Load max. mA % RP20-123.3SF 9-18 3.3 5000 1719 84 13000F RP20-1205SF 9-18 5 4000 2008 87 6800F RP20-1212SF 9-18 12 1670 2062 85 2200F RP20-1215SF 9-18 15 1330 2052 85 755F RP20-243.3SF 18-36 3.3 5000 838 86 13000F RP20-2405SF 18-36 5 4000 980 89 6800F RP20-2412SF 18-36 12 1670 1006 87 2200F RP20-2415SF 18-36 15 1330 1002 87 755F RP20-483.3SF 36-75 3.3 5000 414 87 13000F RP20-4805SF 36-75 5 4000 490 89 6800F RP20-4812SF 36-75 12 1670 497 88 2200F RP20-4815SF 36-75 15 1330 500 87 755F RP20-1212DF 9-18 12 833 2032 86 680F RP20-1215DF 9-18 15 667 2034 86 450F RP20-2412DF 18-36 12 833 1004 87 680F RP20-2415DF 18-36 15 667 1005 87 450F RP20-4812DF 36-75 12 833 496 88 680F RP20-4815DF 36-75 15 667 502 87 450F UL-60950-1 Certified E196683 RP20-F * no suffix for CTRL function with Positive Logic (1=ON, 0=OFF), this is standard * add /N for CTRL function with Negative Logic (0=ON, 1=OFF) * add suffix -HC for premounted heatsink and clips Ordering Examples RP20-2405SF = 24V Input, 5V Output, Positive Logic CTRL pin fitted RP20-4812DF/N-HC = 48V Input, 12V Output, Negative Logic CTRL pin fitted, Heatsink fitted Please Read Application Notes P-46 REV: 0/2009 www.recom-electronic.com RP20-S_DF Series POWERLINE DC/DC-Converter Derating Graph (Ambient Temperature) RP20-1205SF With Heat Sink RP20-1205SF 125 125 100 100 75 Natural Convection 50 Output Power (%) Output Power (%) 75 25 0 -40 -25 -10 0 50 60 70 Ambient Temperature Range (C) Natural Convection 50 25 0 -40 -25 -10 0 50 60 70 80 90 100 Ambient Temperature Range (C) 80 90 100 65C Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact our technical support service at info@recom-development.at RP20-481.5SF Efficiency VS Input Voltage Efficiency VS Output Load Efficiency (%) 83 82 81 80 79 78 77 76 75 74 73 72 RP20-481.5SF 36 40 45 50 55 60 65 70 75 Input Voltage (V) 82 81 80 79 78 77 76 74 72 70 65 60 1 2 3 4 5 RP20-F Efficiency (%) Typical Characteristics 6 Output Load (A) Specifications (typical at nominal input and 25C unless otherwise noted) Input Voltage Range 12V nominal input 24V nominal input 48V nominal input Input Filter (see Note 9) L-C Type Input Voltage Variation dv/dt (Complies with ETS300 132 part 4.4) Input Surge Voltage (100 ms max.) 12V Input 24V Input 48V Input Input Reflected Ripple (nominal Vin and full load) (see Note 3) Start Up Time (nominal Vin and constant resistor load) Remote ON/OFF (see Note 7) Remote OFF input current 9-18VDC 18-36VDC 36-75VDC 5V/ms max 36VDC 50VDC 100VDC 20mAp-p DC-DC ON DC-DC OFF Nominal input Output Power 10ms typ. Open or 3.0V < Vr < 12V Short or 0V < Vr < 1.2V 2.5mA 20W max. Output Voltage Accuracy (full Load and nominal Vin) 1% Voltage Adjustability 10% continued on next page www.recom-international.com REV:0/2009 P-47 RP20-S_DF Series POWERLINE DC/DC-Converter Specifications (typical at nominal input and 25C unless otherwise noted) Minimum Load (see Note 1) Single Dual Line Regulation (low line, high line at full load) 0.2% Load Regulation (25% to 100% full load) 0.5% Cross Regulation (asymmetrical 25% <>100% load) Ripple and Noise (20MHz bandwith) (Measured with a 1004pF/50V MLCC) Dual Single 1.5, 1.8, 2.5, 3.3V Single 5, 12, 15V Dual 5, 12, 15V Temperature Coefficient Over Voltage Protection Zener diode clamp (only single) 5% 60mVp-p 75mVp-p 100mVp-p 0.02%/C max. Transient Response (25% load step change) 500s 1.5, 1.8, 2.5, 3.3V 5V 12V 15V Over Load Protection (% of full load at nominal Vin) 3.9V 6.2V 15V 18V 150% typ Undervoltage Lockout none Short Circuit Protection Hiccup, automatic recovery Efficiency Isolation Voltage see Selection Guide" table 1600VDC min. 1600VDC min. Input to Output Input (Output) to case Isolation Resistance RP20-F 0% 10% of full load 1 G min. Isolation Capacitance 1000pF max. Operating Frequency 500kHz typ. Operating Temperature Range -40C to +85C(with derating) Maximum Case Temperature +100C Storage Temperature Range Thermal Impedance (see Note 8) -55C to +125C Natural convection Natural convection with Heat Sink Thermal Shock 12C/Watt 10C/Watt MIL-STD-810D Vibration 10-55Hz, 10G, 30 Min. along X, Y and Z Relative Humidity 5% to 95% RH Case Material Nickel plated copper Base Material Non-conductive black plastic Potting Material Conducted Emissions (see Note 10) Radiated Emissions ESD Radiated Immunity Fast Transient Surge Conducted Immunity Epoxy (UL94-V0) EN55022 EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 Weight 27g Dimensions 50.8 x 25.4 x 10.2mm 1791 x 103 hours MTBF (see Note 2) P-48 Class A Class A Perf. Criteria B Perf. Criteria B Perf. Criteria B Perf. Criteria B Perf. Criteria B REV: 0/2009 www.recom-electronic.com RP20-S_DF Series POWERLINE DC/DC-Converter Notes : 1. The RP20-S_DF series requires a minimum of 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specification. 2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40C (Ground fixed and controlled environment). 3. Simulated source impedance of 12H. 12H inductor in series with +Vin. 4. Maximum value at nominal input voltage and full load of standard type. 5. Typical value at nominal input voltage and full load. 6. Test by minimum Vin and constant resistor load. 7. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input. Positive logic ON/OFF is standard, no suffix (Ex. RP20-2405SF) Negative logic ON/OFF is marked with suffix-N (Ex. RP20-2405SF/N). 8. Heat sink is optional and P/N: 7G-0020C. Powerline DC/DC Converters can be ordered with pre-mounted heatsinks including antivibration fixing clips (add suffix -HC). See Application Notes for heatsink details. 9. An external filter capacitor is required for normal operation. The capacitor should be capable of handling 1A ripple current for 48V/24V models. RECOM suggest: Nippon chemi-con KY series, 220F/100V, ESR 90m . 10.See application notes for Class B common mode filter suggestion. Package Style and Pinning (mm) 3rd angle projection 50.80 25.40 10.20 dia. 1.0 5.6 RP20-F 2.50 5.10 20.30 15.20 Pin Connections Pin # 1 2 3 4 5 6 3 1 2 6 Bottom View 10.20 4 10.20 5 12.70 5 Output can be externally trimmed by using the method shown below. See Application Notes for details. Trim Up 4 Trim Down RD RU 4 REV:0/2009 Dual +Vin -Vin +Vout Com -Vout CTRL Pin Pitch Tolerance 0.35 mm External Output Trimming www.recom-international.com Single +Vin -Vin +Vout Trim -Vout CTRL 3 P-49