R SERIES POWER SUPPLY R100 R R R series: Single-sided PCB Small and light Built-in inrush current, overcurrent and overvoltage protection circuits. UL recognized, TUV approved, CSA certified Three-year warranty ORDERING INFORMATION R100 -5Optional:Ex.with Cover:N Output voltage UL recognized, TUV approved, CSA certified:U Output wattage Series name SPECIFICATIONS R100-3 MODEL INPUT ENVIRONMENT SAFETY AND NOISE REGULATIONS 1 R100-15 47~440Hz or DC 75%typ EFFICIENCY 79%typ 80%typ 82%typ 83%typ R100-24 84%typ 85%typ 0.5mA max (60Hz, by UL, CSA and Dentori) VOLTAGE [V] 3 5 9 12 15 18 24 CURRENT [A] 20 20 11.5 8.5 7 5.6 4.5 LINE REGULATION [mV] 20 max 20 max 36 max 48 max 60 max 72 max 96 max LOAD REGULATION [mV] 40 max 40 max 100 max 100 max 120 max 120 max 150 max RIPPLE 0~+50 : 80 max 80 max 120 max 120 max 120 max 120 max 120 max [mVp-p] -10~0 : 140 max 140 max 160 max 160 max 160 max 160 max 160 max RIPPLE 0~+50 : 120 max 120 max 150 max 150 max 150 max 150 max 150 max NOISE [mVp-p] -10~0 : 160 max 160 max 180 max 180 max 180 max 180 max 180 max TEMPERATURE REGULATION [mV] 0~+50 : 50 max 50 max 90 max 120 max 150 max 180 max 240 max 20 max 20 max 36 max 48 max 60 max 72 max 96 max [mV]1 START-UP TIME [ms] 200max (ACIN 85V, lo =100 %) HOLD-UP TIME [ms] 20typ OUTPUT VOLTAGE ADJUSTMENT RANGE OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION OPERATING INDICATION REMOTE SENSING [V] (ACIN 100V, lo=100 %,0~+50:) 10typ (ACIN 85V, lo =100 %,0~+50:) 2.85~3.6 4.5~5.5 8.1~9.9 10.8~13.2 13.5~16.5 16.2~19.8 21.6~26.4 Works over 105% of rating and recovers automatically 4.00~5.25V Works at 115%~140% of rating LED (Green) Provided INPUT-OUTPUT AC2,000V, 1minute, Cutoff current= 10mA max, DC500V, 50M min.(At Room Temperature) INPUT-FG AC2,000V, 1minute, Cutoff current= 10mA max, DC500V, 50M min.(At Room Temperature) OUTPUT-FG AC OPERATING TEMP. , HUMID. AND ALTITUDE STORAGE TEMP. , HUMID. AND ALTITUDE -10~+60:,20~90%RH (Non condensing)(Refer to DERATING CURVE) , 3,000m (10,000feet)max VIBRATION 10~55Hz, 19.6m/s2(2G), 3 minutes period, 60 minutes each along X, Y and Z axis 500V, 1minute, Cutoff current=100mA max, DC500V, 50M min.(At Room Temperature) -20~+75:,20~90%RH (Non condensing), 9,000m(30,000feet)max IMPACT 196.1m/s2(20G), 11ms, once each X, Y and Z axis AGENCY APPROVALS UL1950, C-UL, EN60950, VDE0160 Complies with DENTORI and IEC60950 CONDUCTED NOISE Complies with FCC-B, VCCI-B Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25, with the input voltage held constant at the rated input/output. Avoid prolonged use under over-load. Parallel operation with other model is not possible. Derating is required when operated with case cover. 134 R100-18 15A typ (ACIN 100V, lo=100%) DRIFT ISOLATION R100-12 FREQUENCY LEAKAGE CURRENT PROTECTION CIRCUIT AND OTHERS R100-9 AC85~132V 1 or DC110~170V / 2.8A typ (ACIN100V, lo=100%) INRUSH CURRENT OUTPUT R100-5 VOLTAGE / CURRENT