https://www.phoenixcontact.com/us/products/2905232 Type 3 surge protection plug - PLT-SEC-T3-24-P - 2905232 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Replacement plug for type 3 device protection from the PLUGTRAB SEC T3 product range. 24 V nominal voltage. The illustration shows version PLTSEC-T3-230-P Why buy this product Varistor-based device protection Can be used without separate backup fuse thanks to integrated overcurrent protection Pluggable Optical status indicator via LED Plugs can be checked with CHECKMASTER 2 Key Commercial Data Packing unit 1 STK Weight per Piece (excluding packing) 40.000 g Custom tariff number 85363030 Country of origin Germany Technical data Environmental Product Compliance China RoHS No hazardous substances above threshold values Dimensions Height 60.9 mm Width 17.5 mm Depth 44.8 mm Horizontal pitch 1 Div. 09/07/2016 Page 1 / 6 https://www.phoenixcontact.com/us/products/2905232 Type 3 surge protection plug - PLT-SEC-T3-24-P - 2905232 Technical data Ambient conditions Degree of protection IP20 Ambient temperature (operation) -40 C ... 80 C Ambient temperature (storage/transport) -40 C ... 80 C Altitude 2000 m (amsl (above mean sea level)) Permissible humidity (operation) 5 % ... 95 % Shock (operation) 30g (half sinus / 11 ms / 3x X, Y, Z) Vibration (operation) 5g (10 ... 150 Hz/20 cycles/axis/X, Y, Z) General IEC test classification III T3 EN type T3 SPD design Combination type Mode of protection L-N L-PE N-PE (L+) - (L-) (L+/L-) - PE Mounting type On base element Color light grey RAL 7035 Housing material PA 6.6-FR 20% GF PA 6.6-FR Degree of pollution 2 Flammability rating according to UL 94 V-0 Type Male Number of positions 2 Surge protection fault message optical Protective circuit Nominal voltage UN 24 V AC (TN-S) Nominal frequency fN 50 Hz (60 Hz) Maximum continuous voltage UC 34 V AC 34 V DC Residual current IPE 5 A Nominal discharge current In (8/20) s 1 kA Standby power consumption PC 30 mVA (at UREF) 50 mVA (at UC) Reference test voltage UREF 27 V AC 09/07/2016 Page 2 / 6 https://www.phoenixcontact.com/us/products/2905232 Type 3 surge protection plug - PLT-SEC-T3-24-P - 2905232 Technical data Protective circuit Combination wave UOC 2 kV Voltage protection level Up (L-N) 0.25 kV Voltage protection level Up (L-PE) 0.65 kV Voltage protection level Up (N-PE) 0.65 kV TOV behavior at UT (L-N) 50 V AC (5 s / withstand mode) 50 V AC (120 min / withstand mode) TOV behavior at UT (L-PE) 50 V AC (5 s / withstand mode) 50 V AC (120 min / withstand mode) Response time tA (L-N) 25 ns Response time tA (L-PE) 100 ns Response time tA (N-PE) 100 ns Short-circuit current rating ISCCR 1.5 kA AC 1 kA DC Connection data Connection method pluggable UL specifications SPD Type 4CA Maximum continuous operating voltage MCOV 34 V AC 34 V DC Nominal voltage 24 V DC Mode of protection L-N L-G N-G (L+) - (L-) (L+) - G (L-) - G Power distribution system 1 Nominal frequency 50/60 Hz Measured limiting voltage MLV (L-N) 290 V Measured limiting voltage MLV (L-G) 560 V Measured limiting voltage MLV (N-G) 560 V Measured limiting voltage MLV (L+) - (L-) 290 V Measured limiting voltage MLV (L+) - G 560 V Measured limiting voltage MLV (L-) - G 560 V Nominal discharge current In 1 kA 09/07/2016 Page 3 / 6 https://www.phoenixcontact.com/us/products/2905232 Type 3 surge protection plug - PLT-SEC-T3-24-P - 2905232 Technical data Standards and Regulations Standards/specifications IEC 61643-11 2011 EN 61643-11 2012 Drawings Circuit diagram Dimensional drawing L N 17,5 51,4 60,9 44,8 PE Classifications eCl@ss eCl@ss 5.1 27130801 eCl@ss 6.0 27130806 eCl@ss 8.0 27130806 eCl@ss 9.0 27130806 ETIM ETIM 5.0 EC000942 Approvals Approvals Approvals KEMA-KEUR / CCA / IECEE CB Scheme / UL Recognized / cUL Recognized / EAC / GL / cULus Recognized Ex Approvals UL Recognized / cUL Recognized / cULus Recognized Approval details 09/07/2016 Page 4 / 6 https://www.phoenixcontact.com/us/products/2905232 Type 3 surge protection plug - PLT-SEC-T3-24-P - 2905232 Approvals KEMA-KEUR http://www.dekra-certification.com 2173868.01 CCA NTR-NL 7399 IECEE CB Scheme UL Recognized cUL Recognized http://www.iecee.org/ NL-35777 http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181 http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 330181 EAC RU C-DE.A*30.B01561 GL http://www.gl-group.com/newbuilding/approvals/index.html 14588-15 HH cULus Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm Accessories Accessories Device marking Label - EML (20XE)R - 0803452 Label, Roll, white, unlabeled, can be labeled with: THERMOMARK ROLL, THERMOMARK ROLL X1, THERMOMARK X, THERMOMARK S1.1, Mounting type: Adhesive, Lettering field: continuous x 20 mm 09/07/2016 Page 5 / 6 https://www.phoenixcontact.com/us/products/2905232 Type 3 surge protection plug - PLT-SEC-T3-24-P - 2905232 Accessories Label - EML (20XE)R YE - 0803453 Label, Roll, yellow, unlabeled, can be labeled with: THERMOMARK ROLL, THERMOMARK ROLL X1, THERMOMARK X, THERMOMARK S1.1, Mounting type: Adhesive, Lettering field: continuous x 20 mm End block End clamp - CLIPFIX 35 - 3022218 Quick mounting end clamp for NS 35/7,5 DIN rail or NS 35/15 DIN rail, with marking option, width: 9.5 mm, color: gray Marker pen Marker pen - X-PEN 0,35 - 0811228 Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm Additional products Type 3 surge protection base element - PLT-SEC-T3-BE - 2905557 Base element for protective plugs from the PLUGTRAB SEC product series with remote indication contact. Phoenix Contact 2016 (c) - all rights reserved http://www.phoenixcontact.com 09/07/2016 Page 6 / 6