Microwave MLC's AQ Series Available Capacitance/Size/WVDC/T.C. TABLE II: TC: A (030PPM/C) CASE SIZE 11, 12, 13 & 14 DIMENSIONS: inches (millimeters) Case Length Width Thickness Band Width Avail. Term. 11 12 13 14 .055.015 (1.40.381) .055.025 (1.40.635) .110.020 (2.79.508) .110 +0.035 -0.020 (2.79 +.889 -.508) .055.015 (1.40.381) .055.015 (1.40.381) .110.020 (2.79.508) .110.020 (2.79.508) .020/.057 (.508/1.45) .020/.057 (.508/1.45) .030/.102 (.762/2.59) .030/.102 (.762/2.59) .010 +.010 -.005 (.254 +.254 -.127) .010 +.010 -.005 (.254 +.254 -.127) .015.010 (.381.254) .015.010 (.381.254) 1& 7 J 1& 7 J Case: AQ13, AQ14 Case: AQ11, AQ12 Cap. pF Cap. Tol. WVDC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.2 2.4 2.7 3.0 3.3 3.6 3.9 4.3 4.7 5.1 5.6 6.2 6.8 7.5 8.2 9.1 10 11 12 13 15 16 18 20 22 B B B,C B,C B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, J, K, M B, C, J, K, M B, C, J, K, M B, C, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 Cap. pF 24 27 30 33 36 39 43 47 51 56 62 68 75 82 91 100 110 120 130 150 160 180 200 220 240 270 300 330 360 390 430 470 510 560 620 680 750 820 910 1000 Cap. Tol. WVDC Cap. pF Cap. Tol. WVDC Cap. pF Cap. Tol. WVDC F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.2 2.4 2.7 3.0 3.3 3.6 3.9 4.3 4.7 5.1 5.6 6.2 6.8 7.5 8.2 9.1 10 11 12 13 15 16 18 20 22 24 27 30 33 36 39 43 47 B B B,C B,C B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, J, K, M B, C, J, K, M B, C, J, K, M B, C, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 51 56 62 68 75 82 91 100 110 120 130 150 160 180 200 220 240 270 300 330 360 390 430 470 510 560 620 680 750 820 910 1000 1100 1200 1300 1500 1600 1800 2000 2200 2400 2700 3000 3300 3600 3900 4300 4700 5000 5100 F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M 500 500 500 500 500 500 500 500 300 300 300 300 300 300 300 200 200 200 200 200 200 200 200 200 150 150 150 150 150 150 150 150 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 TABLE III: TC: C (15%) CASE SIZE 12 & 14 Case: AQ12 Cap. pF 1000 1200 1500 1800 2000 Cap. Tol. K, M, N K, M, N K, M, N K, M, N K, M, N WVDC 50 50 50 50 50 Cap. pF 2200 2700 3300 3900 4700 Cap. Tol. K, M, N K, M, N K, M, N K, M, N K, M, N WVDC 50 50 50 50 50 Case: AQ14 Cap. pF 5100 5600 6800 8200 10000 Cap. Tol. K, M, N K, M, N K, M, N K, M, N K, M, N WVDC 50 50 50 50 50 Cap. pF 5000 6800 8200 10000 12000 Cap. Tol. K, M, N K, M, N K, M, N K, M, N K, M, N WVDC 50 50 50 50 50 Cap. pF 15000 18000 27000 33000 39000 Cap. Tol. K, M, N K, M, N K, M, N K, M, N K, M, N WVDC 50 50 50 50 50 Cap. pF 47000 68000 82000 100000 Cap. Tol. K, M, N K, M, N K, M, N K, M, N WVDC 50 50 50 50 207 8 Microwave MLC's CDR Series -- MIL-PRF-55681 (RF/Microwave Chips) MILITARY DESIGNATION PER MIL-PRF-55681 L W L W A 0J 47 T 0J 10 T bw bw CDR11/12 CDR13/14 CROSS REFERENCE: AVX/MIL-PRF-55681 Per MIL-C-55681 AVX Style Length (L) Width (W) Thickness (T) Max Min CDR11 AQ11 CDR12 AQ12 CDR13 AQ13 CDR14 AQ14 .055.015 (1.40.381) .055.025 (1.40.635) .110.020 (2.79.508) .110 +.035 -0.020 (2.79 +.889 -.508) .055.015 (1.40.381) .055.015 (1.40.381) .110.020 (2.79.508) .110.020 (2.79.508) .057 (1.45) .057 (1.45) .102 (2.59) .102 (2.59) Termination Band (bw) Max Min .020 (.508) .020 (.508) .030 (.762) .030 (.762) .020 (.508) .020 (.508) .025 (.635) .025 (.635) .005 (.127) .005 (.127) .005 (.127) .005 (.127) HOW TO ORDER CDR12 BG 101 A MIL Style Capacitance CDR11, CDR12, CDR13, CDR14 EIA Capacitance Code in pF. First two digits = significant figures or "R" for decimal place. Third digit = number of zeros or after "R" significant figures. Voltage Temperature Limits BG = +9020 ppm/C with and without rated voltage from -55C to + 125C BP = 030ppm/C with and without rated voltage from -55C to +125C Rated Voltage Code A = 50V B = 100V C = 200V D = 300V E = 500V K U S Capacitance Tolerance Code Failure Rate Level B = .1 pF C = .25 pF D = .5 pF F = 1% G = 2% J = 5% K = 10% M = 20% M = 1.0% P = .1% R = .01% S = .001% PACKAGING Standard Packaging Quanity CDR11-12 = 100 pcs per waffle pack CDR13-14 = 80 pcs per waffle pack TAPE & REEL: All tape and reel specifications are in compliance with EIA RS481 Termination Finish (Military Designations) Code M = Palladium silver N = Silver-nickel-gold S = Solder coated final with a minimum of 4 percent lead T = Silver U = Base metallization-barrier metal-solder coated (tin/lead alloy, with a minimum of 4 percent lead) W = Base metallization-barrier metal-tinned (tin or tin/lead alloy) Y = Base metallization-barrier metal-tin (100 percent) Z = Base metallization-barrier metal-tinned (tin/lead alloy, with a minimum of 4 percent lead) *See MIL-PRF-55681 Specification for more details Not RoHS Compliant (equivalent to IEC 286 part 3). Sizes SQCA through SQCB, CDR11/12 through 13/14. 8 --8mm carrier --7" reel: 0.040" thickness = 2000 pcs 0.075" thickness = 2000 pcs --13" reel: 0.075" thickness = 10,000 pcs 208 LEAD-FREE COMPATIBLE COMPONENT For RoHS compliant products, please select correct termination style. Microwave MLC's CDR Series -- MIL-PRF-55681 (RF/Microwave Chips) TABLE I: STYLES CDR11 AND CDR12 CAPACITOR CHARACTERISTICS Type Designation 1/ Capacitance in pF Capacitance tolerance Rated temperature and V/Temperature WVDC CDR1 -B-0R1AB-CDR1 -B-0R2AB-CDR1 -B-0R3A--CDR1 -B-0R4A--CDR1 -B-0R5A--CDR1 -B-0R6A--CDR1 -B-0R7A--CDR1 -B-0R8A--CDR1 -B-0R9A--CDR1 -B-1R0A--CDR1 -B-1R1A--CDR1 -B-1R2A--CDR1 -B-1R3A--CDR1 -B-1R4A--CDR1 -B-1R5A--CDR1 -B-1R6A--CDR1 -B-1R7A--CDR1 -B-1R8A--CDR1 -B-1R9A--CDR1 -B-2R0A--CDR1 -B-2R1A--CDR1 -B-2R2A--CDR1 -B-2R4A--CDR1 -B-2R7A--CDR1 -B-3R0A--CDR1 -B-3R3A--CDR1 -B-3R6A--CDR1 -B-3R9A--CDR1 -B-4R3A--CDR1 -B-4R7A--CDR1 -B-5R1A--CDR1 -B-5R6A--CDR1 -B-6R2A--CDR1 -B-6R8A--CDR1 -B-7R5A--CDR1 -B-8R2A--CDR1 -B-9R1A--CDR1 -B-100A--CDR1 -B-110A--CDR1 -B-120A--CDR1 -B-130A--CDR1 -B-150A--CDR1 -B-160A--CDR1 -B-180A--CDR1 -B-200A--CDR1 -B-220A--CDR1 -B-240A--CDR1 -B-270A--- 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.4 2.7 3.0 3.3 3.6 3.9 4.3 4.7 5.1 5.6 6.2 6.8 7.5 8.2 9.1 10 11 12 13 15 16 18 20 22 24 27 B B B, C B, C B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, J, K, M B, C, J, K, M B, C, J, K, M B, C, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 Type Designation 1/ CDR1 -B-300A--CDR1 -B-330A--CDR1 -B-360A--CDR1 -B-390A--CDR1 -B-430A--CDR1 -B-470A--CDR1 -B-510A--CDR1 -B-560A--CDR1 -B-620A--CDR1 -B-680A--CDR1 -B-750A--CDR1 -B-820A--CDR1 -B-910A--CDR1 -B-101A--CDR1 -B-111A--CDR1 -B-121A--CDR1 -B-131A--CDR1 -B-151A--CDR1 -B-161A--CDR1 -B-181A--CDR1 -B-201A--CDR1 -B-221A--CDR1 -B-241A--CDR1 -B-271A--CDR1 -B-301A--CDR1 -B-331A--CDR1 -B-361A--CDR1 -B-391A--CDR1 -B-431A--CDR1 -B-471A--CDR1 -B-511A--CDR1 -B-561A--CDR1 -B-621A--CDR1 -B-681A--CDR1 -B-751A--CDR1 -B-821A--CDR1 -B-911A--CDR1 -B-102A--- Capacitance in pF 30 33 36 39 43 47 51 56 62 68 75 82 91 100 110 120 130 150 160 180 200 220 240 270 300 330 360 390 430 470 510 560 620 680 750 820 910 1000 Capacitance tolerance Rated temperature and V/Temperature WVDC F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 1/Complete type designation will include additional symbols to indicate style, voltage-temperature limits, capacitance tolerance (where applicable), termination finish ("M" or "N" for style CDR11, and "S", "U", "W", "Y" or "Z" for style CDR12) and failure rate level. 8 209 Microwave MLC's CDR Series -- MIL-PRF-55681 (RF/Microwave Chips) TABLE II: STYLES CDR13 AND CDR14 CAPACITOR CHARACTERISTICS Type Designation 1/ CDR1 -B-0R1*B-CDR1 -B-0R2*B-CDR1 -B-0R3*--CDR1 -B-0R4*--CDR1 -B-0R5*--CDR1 -B-0R6*--CDR1 -B-0R7*-CDR1 -B-0R8*--CDR1 -B-0R9*--CDR1 -B-1R0*--CDR1 -B-1R1*--CDR1 -B-1R2*--CDR1 -B-1R3*--CDR1 -B-1R4*--CDR1 -B-1R5*--CDR1 -B-1R6*--CDR1 -B-1R7*--CDR1 -B-1R8*--CDR1 -B-1R9*--CDR1 -B-2R0*--CDR1 -B-2R1*--CDR1 -B-2R2*-CDR1 -B-2R4*--CDR1 -B-2R7*--CDR1 -B-3R0*--CDR1 -B-3R3*--CDR1 -B-3R6*--CDR1 -B-3R9*--CDR1 -B-4R3*--CDR1 -B-4R7*--CDR1 -B-5R1*--CDR1 -B-5R6*--CDR1 -B-6R2*--CDR1 -B-6R8*--CDR1 -B-7R5*--CDR1 -B-8R2*--CDR1 -B-9R1*--CDR1 -B-100*--CDR1 -B-110*--CDR1 -B-120*--CDR1 -B-130*--CDR1 -B-150*--CDR1 -B-160*--CDR1 -B-180*--CDR1 -B-200*--CDR1 -B-220*--CDR1 -B-240*--CDR1 -B-270*--CDR1 -B-300*--CDR1 -B-330*--CDR1 -B-360*--CDR1 -B-390*--CDR1 -B-430*--CDR1 -B-470*--CDR1 -B-510*--- Capacitance in pF Capacitance tolerance Rated temperature and V/Temperature WVDC 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.4 2.7 3.0 3.3 3.6 3.9 4.3 4.7 5.1 5.6 6.2 6.8 7.5 8.2 9.1 10 11 12 13 15 16 18 20 22 24 27 30 33 36 39 43 47 51 B B B, C B, C B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, D B, C, J, K, M B, C, J, K, M B, C, J, K, M B, C, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/500 Type Designation 1/ CDR1 -B-560*--CDR1 -B-620*--CDR1 -B-680*--CDR1 -B-750*--CDR1 -B-820*--CDR1 -B-910*--CDR1 -B-101*--CDR1 -B-111--CDR1 -B-121--CDR1 -B-131--CDR1 -B-151--CDR1 -B-161--CDR1 -B-181--CDR1 -B-201--CDR1 -B-221C--CDR1 -B-241C--CDR1 -B-271C--CDR1 -B-301C--CDR1 -B-331C--CDR1 -B-361C--CDR1 -B-391C--CDR1 -B-431C--CDR1 -B-471C--CDR1 -B-511B--CDR1 -B-561B--CDR1 -B-621B--CDR1 -B-681A--CDR1 -B-751A--CDR1 -B-821A--CDR1 -B-911A--CDR1 -B-102A--CDR1 -B-112A--CDR1 -B-122A--CDR1 -B-132A--CDR1 -B-152A--CDR1 -B-162A--CDR1 -B-182A--CDR1 -B-202A--CDR1 -B-222A--CDR1 -B-242A--CDR1 -B-272A--CDR1 -B-302A--CDR1 -B-332A--CDR1 -B-362A--CDR1 -B-392A--CDR1 -B-432A--CDR1 -B-472A--CDR1 -B-502A--CDR1 -B-512A--- 210 56 62 68 75 82 91 100 110 120 130 150 160 180 200 220 240 270 300 330 360 390 430 470 510 560 620 680 750 820 910 1000 1100 1200 1300 1500 1600 1800 2000 2200 2400 2700 3000 3300 3600 3900 4300 4700 5000 5100 Capacitance tolerance Rated temperature and V/Temperature WVDC F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BG, BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP BP 200/500 200/500 200/500 200/500 200/500 200/500 200/500 200/300 200/300 200/300 200/300 200/300 200/300 200/300 200 200 200 200 200 200 200 200 200 100 100 100 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 1/Complete type designation will include additional symbols to indicate style, voltage-temperature limits, capacitance tolerance (where applicable), termination finish ("M" or "N" for style CDR13, and "S", "U", "W", "Y" or "Z" for style CDR14) and failure rate level. *C=200V; E=500V. C=200V; D=300V. 8 Capacitance in pF Microwave MLC's Performance Curves TYPICAL Q vs. FREQUENCY AQ11/12 MIL-PRF-55681E - BG STANDARD - M TYPICAL ESR vs. FREQUENCY AQ11/12 MIL-PRF-55681E - BG STANDARD - M 10000 1 1000 ESR (ohms) 0.1 Q 100 10 0.01 100 1000 100 Frequency (MHz) 1 Picofarad AVX CORPORATION 10 Picofarad 1000 Frequency (MHz) 100 Picofarad 3.3 Picofarad AVX CORPORATION 10 Picofarad 100 Picofarad TYPICAL ESR vs. CAPACITANCE AQ11/12 MIL-PRF-55681E - BG STANDARD - M TYPICAL Q vs. CAPACITANCE AQ11/12 MIL-PRF-55681E - BG STANDARD - M 1 10000 1000 ESR (ohms) 0.1 Q 100 10 1 10 100 0.01 1 250 MHz AVX CORPORATION 500 MHz 10 100 Capacitance (pF) Capacitance (pF) 1000 MHz 250 MHz AVX CORPORATION 500 MHz 1000 MHz 8 211 Microwave MLC's Performance Curves TYPICAL Q vs. FREQUENCY AQ13/14 MIL-PRF-55681E - BG STANDARD - M TYPICAL ESR vs. FREQUENCY AQ13/14 MIL-PRF-55681E - BG STANDARD - M 10000 1 1000 Q ESR (ohms) 0.1 100 10 100 1000 0.01 100 Frequency (MHz) AVX CORPORATION 10 Picofarad 47 Picofarad 1 Picofarad 1000 Frequency (MHz) 330 Picofarad TYPICAL Q vs. CAPACITANCE AQ13/14 MIL-PRF-55681E - BG STANDARD - M 10000 1 Picofarad AVX CORPORATION 15 Picofarad 100 Picofarad TYPICAL ESR vs. CAPACITANCE AQ13/14 MIL-PRF-55681E - BG STANDARD - M 1 1000 ESR (ohms) 0.1 Q 100 10 1 10 100 0.01 1 Capacitance (pF) 250 MHz 8 212 AVX CORPORATION 500 MHz 10 100 Capacitance (pF) 1000 MHz 250 MHz AVX CORPORATION 500 MHz 1000 MHz Microwave MLC's Performance Curves TYPICAL ESR vs. FREQUENCY AQ11/12 MIL-PRF-55681E - BP STANDARD - A TYPICAL Q vs. FREQUENCY AQ11/12 MIL-PRF-55681E - BP STANDARD - A 1 10000 1000 ESR (ohms) 0.1 Q 100 10 0.01 100 1000 100 Frequency (MHz) 1 Picofarad AVX CORPORATION 15 Picofarad 1000 Frequency (MHz) 100 Picofarad TYPICAL Q vs. CAPACITANCE AQ11/12 MIL-PRF-55681E - BP STANDARD - A 10000 1 Picofarad AVX CORPORATION 15 Picofarad 100 Picofarad TYPICAL ESR vs. CAPACITANCE AQ11/12 MIL-PRF-55681E - BP STANDARD - A 1 1000 ESR (ohms) 0.1 Q 100 10 1 10 100 0.01 1 Capacitance (pF) 250 MHz AVX CORPORATION 500 MHz 10 100 Capacitance (pF) 1000 MHz 250 MHz AVX CORPORATION 500 MHz 1000 MHz 8 213 Microwave MLC's Performance Curves TYPICAL ESR vs. FREQUENCY AQ13/14 MIL-PRF-55681E - BP STANDARD - A TYPICAL Q vs. FREQUENCY AQ13/14 MIL-PRF-55681E - BP STANDARD - A 1 10000 1000 ESR (ohms) 0.1 Q 100 10 0.01 100 1000 100 2 Picofarad AVX CORPORATION 15 Picofarad 1000 Frequency (MHz) Frequency (MHz) 100 Picofarad 15 Picofarad TYPICAL Q vs. CAPACITANCE AQ13/14 MIL-PRF-55681E - BP STANDARD - A 10000 AVX CORPORATION 47 Picofarad 100 Picofarad TYPICAL ESR vs. CAPACITANCE AQ13/14 MIL-PRF-55681E - BP STANDARD - A 1 1000 ESR (ohms) 0.1 Q 100 10 1 10 100 0.01 1 Capacitance (pF) 250 MHz 8 214 AVX CORPORATION 500 MHz 10 100 Capacitance (pF) 1000 MHz 250 MHz AVX CORPORATION 500 MHz 1000 MHz Microwave MLC's Performance Curves TYPICAL RESONANT FREQUENCY vs. CAPACITANCE AVX AQ11-14 (CDR11-14) 10 AQ11/12 AQ13/14 Parallel Resonant Frequency Frequency (GHz) AQ11/12 AQ13/14 1.0 Series Resonant Frequency 0.1 1.0 100 10 1000 Capacitance (pF) TYPICAL RESONANT FREQUENCY vs. CAPACITANCE AVX 0603 Frequency (GHz) 10 Parallel Resonant Frequency 1.0 Series Resonant Frequency 0.1 1 100 10 1000 Capacitance (pF) 8 215